lemonergy/ data Sign in

Open battery ageing data · FreeTwinEV 1S4P module

FreeTwinEV module data: four Molicel P45B cells in parallel, 14 runs

The FreeTwinEV module measurements (Plzák, Berta, Ürge and Baťa, Slovak University of Technology in Bratislava, for the EU project FreeTwinEV, 2026) tested one laboratory module of four Molicel INR-21700-P45B cells in parallel (1S4P) on a liquid-cooled plate. This is a module, not a single cell: the current, capacity and energy are the module’s, and only the surface temperatures are measured per cell. Each of the 14 runs started from a full charge and discharged the module at a constant 20 to 120 A, to 2.5 V or until a cell surface reached 70 °C, with the coolant at 5, 15 or 25 °C and 0.1 to 1.5 L/min. The 11 discharges to 2.5 V delivered 16.17 to 16.90 Ah; the three at 120 A stopped near 70 °C, above 2.5 V. These are runs at different settings, not ageing, so nothing is drawn. Lemonergy computed one row per run from the published files.

Free to download, no account needed. Or read it straight into Python:

import pandas as pd
cycles = pd.read_csv("https://lemonergy.com/data/ageing/freetwinev-p45b-1s4p-2026/cycles.csv")
Cells
1 module of 4 cells in parallel (1S4P), 21700; maker: Molicel
Chemistry
not stated
Nominal capacity
not stated
Runs
14, one row each
Test programmes
13
Published by
Slovak University of Technology in Bratislava, for the EU project FreeTwinEV
Licence
CC BY 4.0
Files retrieved
2026-11-12

Source: Electro-thermal measurements of a 1s4p Molicel INR21700-P45B battery module (14 runs, one row per run), Slovak University of Technology in Bratislava, for the EU project FreeTwinEV, doi:10.5281/zenodo.18405243. Licence: CC BY 4.0.

Cite: Plzák, M., Berta, Š., Ürge, A., Baťa, M. P45B 1s4p Battery Module Measurement (README title: Electro-Thermal Measurements of a 1s4p Molicel INR21700-P45B Battery Module). Zenodo (2026). doi:10.5281/zenodo.18405243

Licence and how to cite · Data quality · Every source file, by SHA-256

Capacity fade: not drawn

These runs have no ageing axis, so the chart draws nothing. The reason is below; every run is in the CSV.

Not drawn: the 14 rows are runs of one module, each a single discharge at its own current, coolant temperature and flow, not ageing cycles, so there is no ageing axis to draw capacity fade against. The 11 discharges to 2.5 V delivered 16.17 to 16.90 Ah; the three at 120 A stopped near the 70 °C cell-surface limit, above 2.5 V, at 12.20 to 14.21 Ah. Every run is in the CSV.

Every cell

The one module; nothing is drawn. Every row of every cell, with all its values, is in the CSV (6 kB).

ProgrammeCellRunsPoints drawnFirst (Ah)Last (Ah)Last / first
all 13 programmesFreeTwinEV_1s4p14not drawn–––

Test programmes

Columns of the CSV

Read with battery-data tools/convert_freetwinev_1s4p.py from the zip, without unpacking: the 14 AllData/<ID>/FreeTwinEV_1s4p_ID_<nn>.csv files (the identical .xlsx copies are not read) and the Test_Matrix sheet of Measurement_Protocol.xlsx. A source entry is one run's CSV (path, bytes, SHA-256 of the file in the zip); its `cycle` is the row it gives. Steps are found in the logged module current: the discharge is the run of rows below -1 A, a charge a run of rows above +0.02 A. Ah and Wh are the trapezoid of current and of current times voltage on the timestamp, from the row before the step to the row after it; an interval longer than 10 s would not be integrated across. Temperatures are converted from kelvin (T - 273.15).

ColumnUnitMeaning
batch–the run's settings from Test_Matrix: set discharge current (negative, as printed), coolant temperature and flow rate
cell–the module, named as the record's files name it (FreeTwinEV_1s4p); not a cell
cycle–run number 1..14 in the order of the record's experiment IDs (run_id)
run_id–Experiment ID in Test_Matrix and in the run's folder name (ID01 ... ID22)
daq_timestamp–DAQ timestamp of the run as Test_Matrix and the folder name print it (yyyymmdd_hhmmssmmm)
label–the steps found in the logged current, in order, with their measured currents and end points
set_discharge_current_aAthe module's set discharge current, Test_Matrix Discharge_current [A] as printed (negative = discharge)
set_charge_current_aAthe module's set charge current, Test_Matrix Charge_current [A] as printed
set_coolant_temp_c°CTest_Matrix Coolant Temp [°C], the setpoint
set_flow_l_minL/minTest_Matrix Flow Rate [l/min], the setpoint
duration_ssfirst to last timestamp of the run's file
discharge_duration_ssfirst to last row of the discharge step (module current below -1 A)
discharge_current_mean_aAmean logged module current over the discharge step (negative = discharge, as logged)
discharge_ahAhmodule charge delivered in the discharge step: logged module current integrated over the timestamp (trapezoid), including the interval on each side of the step
discharge_whWhmodule energy delivered in the discharge step: logged module current times module voltage, integrated as discharge_ah
discharge_v_endVmodule voltage at the last row of the discharge step
cell_max_at_discharge_end_c°Chighest of the 12 cell-surface sensors at the last row of the discharge step (converted from K)
charge_duration_ssfirst to last row of the first charge step after the discharge (module current above +0.02 A); empty if no charge is logged
charge_ahAhmodule charge taken in that charge step, integrated as discharge_ah; empty if none (see label for a partial charge)
charge_whWhmodule energy taken in that charge step, integrated as discharge_wh
charge_end_current_aAmodule current at the last row of that charge step
charge_end_vVmodule voltage at the last row of that charge step
v_startVmodule voltage at the first row of the run
v_endVmodule voltage at the last row of the run
v_minVlowest module voltage in the run
v_maxVhighest module voltage in the run
soc_start_pct%the logger's SOC column at the first row (the record does not say how it is computed)
soc_discharge_end_pct%the logger's SOC column at the last row of the discharge step
flow_mean_l_minL/minmean logged coolant flow over the discharge step
ambient_mean_c°Cmean ambient temperature over the discharge step (converted from K)
inlet_mean_c°Cmean coolant inlet temperature over the discharge step (converted from K)
outlet_mean_c°Cmean coolant outlet temperature over the discharge step (converted from K)
coolant_out_minus_in_mean_kKmean of coolant outlet minus inlet temperature over the discharge step
coolant_out_minus_in_max_kKlargest coolant outlet minus inlet temperature from the start of the discharge to the start of the next charge (or the end of the file)
cell_start_mean_c°Cmean of the 12 cell-surface sensors at the first row of the discharge step (converted from K)
cell1_max_c°Chighest reading of cell 1's three sensors (TH20-TH22) from the start of the discharge to the start of the next charge or the end of the file (converted from K)
cell2_max_c°Cas cell1_max_c, cell 2 (TH17-TH19)
cell3_max_c°Cas cell1_max_c, cell 3 (TH14-TH16)
cell4_max_c°Cas cell1_max_c, cell 4 (TH11-TH13)
cell_max_c°Chighest of cell1_max_c to cell4_max_c
cell_rise_max_kKlargest rise of any cell-surface sensor, over the same span, above its own reading at the first row of the discharge
plate_max_c°Chighest cooling-plate reading (TH1-TH10) over the same span (converted from K)

Data quality

No per-cell quality verdict was recorded for this dataset. Read the caveats below before comparing cells.

Before comparing cells

Licence and how to cite

The values are published under CC BY 4.0, as the source is. Credit it as follows.

Cite: Plzák, M., Berta, Š., Ürge, A., Baťa, M. P45B 1s4p Battery Module Measurement (README title: Electro-Thermal Measurements of a 1s4p Molicel INR21700-P45B Battery Module). Zenodo (2026). doi:10.5281/zenodo.18405243

Credit: Data: Plzák, Berta, Ürge, Baťa (Slovak University of Technology in Bratislava), EU project FreeTwinEV (Horizon Europe grant 101159989), doi:10.5281/zenodo.18405243, CC BY 4.0. Per-run values computed by Lemonergy (battery-data); the time series are not reproduced.

Values pinned to battery-data revision e85dd43. The manifest names every source file by its SHA-256; the CSV’s own SHA-256 is 380143cf7f9d03a7a4cfca510288f774693f8939f8ace39bb4d91e1502c67940.