Open battery ageing data · FreeTwinEV 1S4P module
FreeTwinEV module data: four Molicel P45B cells in parallel, 14 runs
The FreeTwinEV module measurements (Plzák, Berta, Ürge and Baťa, Slovak University of Technology in Bratislava, for the EU project FreeTwinEV, 2026) tested one laboratory module of four Molicel INR-21700-P45B cells in parallel (1S4P) on a liquid-cooled plate. This is a module, not a single cell: the current, capacity and energy are the module’s, and only the surface temperatures are measured per cell. Each of the 14 runs started from a full charge and discharged the module at a constant 20 to 120 A, to 2.5 V or until a cell surface reached 70 °C, with the coolant at 5, 15 or 25 °C and 0.1 to 1.5 L/min. The 11 discharges to 2.5 V delivered 16.17 to 16.90 Ah; the three at 120 A stopped near 70 °C, above 2.5 V. These are runs at different settings, not ageing, so nothing is drawn. Lemonergy computed one row per run from the published files.
Download every run (CSV, 6 kB)Manifest (JSON): files, hashes, unitsChart and Excel downloadOriginal dataset
Free to download, no account needed. Or read it straight into Python:
import pandas as pd
cycles = pd.read_csv("https://lemonergy.com/data/ageing/freetwinev-p45b-1s4p-2026/cycles.csv")- Cells
- 1 module of 4 cells in parallel (1S4P), 21700; maker: Molicel
- Chemistry
- not stated
- Nominal capacity
- not stated
- Runs
- 14, one row each
- Test programmes
- 13
- Published by
- Slovak University of Technology in Bratislava, for the EU project FreeTwinEV
- Licence
- CC BY 4.0
- Files retrieved
- 2026-11-12
Source: Electro-thermal measurements of a 1s4p Molicel INR21700-P45B battery module (14 runs, one row per run), Slovak University of Technology in Bratislava, for the EU project FreeTwinEV, doi:10.5281/zenodo.18405243. Licence: CC BY 4.0.
Cite: Plzák, M., Berta, Š., Ürge, A., Baťa, M. P45B 1s4p Battery Module Measurement (README title: Electro-Thermal Measurements of a 1s4p Molicel INR21700-P45B Battery Module). Zenodo (2026). doi:10.5281/zenodo.18405243
Licence and how to cite · Data quality · Every source file, by SHA-256
Capacity fade: not drawn
These runs have no ageing axis, so the chart draws nothing. The reason is below; every run is in the CSV.
Not drawn: the 14 rows are runs of one module, each a single discharge at its own current, coolant temperature and flow, not ageing cycles, so there is no ageing axis to draw capacity fade against. The 11 discharges to 2.5 V delivered 16.17 to 16.90 Ah; the three at 120 A stopped near the 70 °C cell-surface limit, above 2.5 V, at 12.20 to 14.21 Ah. Every run is in the CSV.
Point at or touch a chart to read every cell’s value at that cycle. Drag across it with a mouse to zoom in. Click a line, or a cell’s name in the legend or table, to show that cell on its own; the others turn grey.Touch a chart to read the values at a cycle. Tap a cell’s name in the legend or the table to show it on its own; the others turn grey.
| Cell | Runs | Points drawn | First (Ah) | Last (Ah) | Last / first |
|---|
Every cell
The one module; nothing is drawn. Every row of every cell, with all its values, is in the CSV (6 kB).
| Programme | Cell | Runs | Points drawn | First (Ah) | Last (Ah) | Last / first |
|---|---|---|---|---|---|---|
| all 13 programmes | FreeTwinEV_1s4p | 14 | not drawn | – | – | – |
Test programmes
- discharge -20 A, coolant 25 °C, flow 1.5 l/min. Test_Matrix: discharge current -20 A, charge current 15 A, coolant 25 °C, flow 1.5 l/min; run(s) ID01.
- discharge -40 A, coolant 25 °C, flow 1.5 l/min. Test_Matrix: discharge current -40 A, charge current 15 A, coolant 25 °C, flow 1.5 l/min; run(s) ID02.
- discharge -40 A, coolant 15 °C, flow 1.5 l/min. Test_Matrix: discharge current -40 A, charge current 15 A, coolant 15 °C, flow 1.5 l/min; run(s) ID11, ID20.
- discharge -80 A, coolant 15 °C, flow 1.5 l/min. Test_Matrix: discharge current -80 A, charge current 15 A, coolant 15 °C, flow 1.5 l/min; run(s) ID12.
- discharge -120 A, coolant 15 °C, flow 1.5 l/min. Test_Matrix: discharge current -120 A, charge current 15 A, coolant 15 °C, flow 1.5 l/min; run(s) ID13.
- discharge -40 A, coolant 15 °C, flow 0.5 l/min. Test_Matrix: discharge current -40 A, charge current 15 A, coolant 15 °C, flow 0.5 l/min; run(s) ID14.
- discharge -80 A, coolant 15 °C, flow 0.5 l/min. Test_Matrix: discharge current -80 A, charge current 15 A, coolant 15 °C, flow 0.5 l/min; run(s) ID15.
- discharge -120 A, coolant 15 °C, flow 0.5 l/min. Test_Matrix: discharge current -120 A, charge current 15 A, coolant 15 °C, flow 0.5 l/min; run(s) ID16.
- discharge -40 A, coolant 15 °C, flow 0.1 l/min. Test_Matrix: discharge current -40 A, charge current 15 A, coolant 15 °C, flow 0.1 l/min; run(s) ID17.
- discharge -80 A, coolant 15 °C, flow 0.1 l/min. Test_Matrix: discharge current -80 A, charge current 15 A, coolant 15 °C, flow 0.1 l/min; run(s) ID18.
- discharge -120 A, coolant 15 °C, flow 0.1 l/min. Test_Matrix: discharge current -120 A, charge current 15 A, coolant 15 °C, flow 0.1 l/min; run(s) ID19.
- discharge -40 A, coolant 5 °C, flow 1.5 l/min. Test_Matrix: discharge current -40 A, charge current 15 A, coolant 5 °C, flow 1.5 l/min; run(s) ID21.
- discharge -80 A, coolant 5 °C, flow 1.5 l/min. Test_Matrix: discharge current -80 A, charge current 15 A, coolant 5 °C, flow 1.5 l/min; run(s) ID22.
Columns of the CSV
Read with battery-data tools/convert_freetwinev_1s4p.py from the zip, without unpacking: the 14 AllData/<ID>/FreeTwinEV_1s4p_ID_<nn>.csv files (the identical .xlsx copies are not read) and the Test_Matrix sheet of Measurement_Protocol.xlsx. A source entry is one run's CSV (path, bytes, SHA-256 of the file in the zip); its `cycle` is the row it gives. Steps are found in the logged module current: the discharge is the run of rows below -1 A, a charge a run of rows above +0.02 A. Ah and Wh are the trapezoid of current and of current times voltage on the timestamp, from the row before the step to the row after it; an interval longer than 10 s would not be integrated across. Temperatures are converted from kelvin (T - 273.15).
| Column | Unit | Meaning |
|---|---|---|
batch | – | the run's settings from Test_Matrix: set discharge current (negative, as printed), coolant temperature and flow rate |
cell | – | the module, named as the record's files name it (FreeTwinEV_1s4p); not a cell |
cycle | – | run number 1..14 in the order of the record's experiment IDs (run_id) |
run_id | – | Experiment ID in Test_Matrix and in the run's folder name (ID01 ... ID22) |
daq_timestamp | – | DAQ timestamp of the run as Test_Matrix and the folder name print it (yyyymmdd_hhmmssmmm) |
label | – | the steps found in the logged current, in order, with their measured currents and end points |
set_discharge_current_a | A | the module's set discharge current, Test_Matrix Discharge_current [A] as printed (negative = discharge) |
set_charge_current_a | A | the module's set charge current, Test_Matrix Charge_current [A] as printed |
set_coolant_temp_c | °C | Test_Matrix Coolant Temp [°C], the setpoint |
set_flow_l_min | L/min | Test_Matrix Flow Rate [l/min], the setpoint |
duration_s | s | first to last timestamp of the run's file |
discharge_duration_s | s | first to last row of the discharge step (module current below -1 A) |
discharge_current_mean_a | A | mean logged module current over the discharge step (negative = discharge, as logged) |
discharge_ah | Ah | module charge delivered in the discharge step: logged module current integrated over the timestamp (trapezoid), including the interval on each side of the step |
discharge_wh | Wh | module energy delivered in the discharge step: logged module current times module voltage, integrated as discharge_ah |
discharge_v_end | V | module voltage at the last row of the discharge step |
cell_max_at_discharge_end_c | °C | highest of the 12 cell-surface sensors at the last row of the discharge step (converted from K) |
charge_duration_s | s | first to last row of the first charge step after the discharge (module current above +0.02 A); empty if no charge is logged |
charge_ah | Ah | module charge taken in that charge step, integrated as discharge_ah; empty if none (see label for a partial charge) |
charge_wh | Wh | module energy taken in that charge step, integrated as discharge_wh |
charge_end_current_a | A | module current at the last row of that charge step |
charge_end_v | V | module voltage at the last row of that charge step |
v_start | V | module voltage at the first row of the run |
v_end | V | module voltage at the last row of the run |
v_min | V | lowest module voltage in the run |
v_max | V | highest module voltage in the run |
soc_start_pct | % | the logger's SOC column at the first row (the record does not say how it is computed) |
soc_discharge_end_pct | % | the logger's SOC column at the last row of the discharge step |
flow_mean_l_min | L/min | mean logged coolant flow over the discharge step |
ambient_mean_c | °C | mean ambient temperature over the discharge step (converted from K) |
inlet_mean_c | °C | mean coolant inlet temperature over the discharge step (converted from K) |
outlet_mean_c | °C | mean coolant outlet temperature over the discharge step (converted from K) |
coolant_out_minus_in_mean_k | K | mean of coolant outlet minus inlet temperature over the discharge step |
coolant_out_minus_in_max_k | K | largest coolant outlet minus inlet temperature from the start of the discharge to the start of the next charge (or the end of the file) |
cell_start_mean_c | °C | mean of the 12 cell-surface sensors at the first row of the discharge step (converted from K) |
cell1_max_c | °C | highest reading of cell 1's three sensors (TH20-TH22) from the start of the discharge to the start of the next charge or the end of the file (converted from K) |
cell2_max_c | °C | as cell1_max_c, cell 2 (TH17-TH19) |
cell3_max_c | °C | as cell1_max_c, cell 3 (TH14-TH16) |
cell4_max_c | °C | as cell1_max_c, cell 4 (TH11-TH13) |
cell_max_c | °C | highest of cell1_max_c to cell4_max_c |
cell_rise_max_k | K | largest rise of any cell-surface sensor, over the same span, above its own reading at the first row of the discharge |
plate_max_c | °C | highest cooling-plate reading (TH1-TH10) over the same span (converted from K) |
Data quality
No per-cell quality verdict was recorded for this dataset. Read the caveats below before comparing cells.
Before comparing cells
- The current is the module's. The record does not measure each cell's current, and nothing here divides the module's values among the four cells; only the surface temperatures are per cell.
- Temperatures in the files are in kelvin; here they are degrees Celsius (T - 273.15), and differences (cell_rise_max_k, coolant_out_minus_in_*) are in kelvin.
- SOC is the logger's own column; the record does not say how it is computed. Over each discharge that ends above 0 % it falls by 100 % per 16.898 to 16.900 Ah of integrated discharge.
- Sampling is about every 5 s (median 5.000 s; the longest interval is 7.413 s, in ID21). No run has an interval longer than 10 s, so nothing is left out of the integration.
- 11 discharges ended at 2.5 V (the last logged row reads 2.518 to 2.553 V) and delivered 16.17 to 16.90 Ah. The 3 discharges at 120 A (ID13, ID16, ID19) ended above it, at 2.825 to 2.963 V, with the hottest cell sensor reading 69.4 to 72.6 °C at the last logged row; the protocol ends a discharge at 2.5 V or at a cell temperature of 70 °C (step 5: 'V_cutoff=2.5V, T_cell≥70') and the record does not say which ended each run. Their 12.20 to 14.21 Ah are not discharges to 2.5 V and do not compare with the others.
- A CC-CV charge is logged in 4 runs (ID01, ID13, ID16, ID19); each ends when the module current has fallen to 0.19 to 0.21 A, not at the protocol's 'I_cutoff=50mA' (step 7). The documents do not say whether 50 mA is per cell or for the module; the values are kept as logged.
- In ID02 the log ends during the charge (Test_Matrix leaves 'DAQ Scan ON @STEP 7' blank for it): the charge columns hold only the part logged, as the label says.
- In ID13 a second, short charge at 4.2 V follows the CC-CV charge after a rest; the record does not say why. It is described in the label and in source_files (charge_steps) and is not in the charge columns.
- Measured coolant flow over each discharge is within 25 % of the Test_Matrix setpoint.
- ID11 and ID20 have the same Test_Matrix settings and are one batch.
- Not imported: the time series themselves (current, voltage, SOC, flow and the 25 temperatures every 5 s), the .xlsx copies of the runs, the photographs, the annotated 3D model, the sensor layout drawing and the material properties of Measurement_Protocol.xlsx, and the .docx note. They are in the record.
- This is a module of four Molicel INR-21700-P45B cells in parallel (1S4P), built in the laboratory, not a single cell. The current, capacity and energy are the module's: the record does not measure each cell's current, and nothing here divides the module's values among the cells. Only the surface temperatures are per cell. The record states no capacity for the module, so none is shown as nominal.
Licence and how to cite
The values are published under CC BY 4.0, as the source is. Credit it as follows.
Cite: Plzák, M., Berta, Š., Ürge, A., Baťa, M. P45B 1s4p Battery Module Measurement (README title: Electro-Thermal Measurements of a 1s4p Molicel INR21700-P45B Battery Module). Zenodo (2026). doi:10.5281/zenodo.18405243
Credit: Data: Plzák, Berta, Ürge, Baťa (Slovak University of Technology in Bratislava), EU project FreeTwinEV (Horizon Europe grant 101159989), doi:10.5281/zenodo.18405243, CC BY 4.0. Per-run values computed by Lemonergy (battery-data); the time series are not reproduced.
Values pinned to battery-data revision e85dd43. The manifest names every source file by its SHA-256; the CSV’s own SHA-256 is 380143cf7f9d03a7a4cfca510288f774693f8939f8ace39bb4d91e1502c67940.
Related
- XJTU battery ageing data: 55 Lishen 18650 cells, cycle by cycle
- CALCE CS2 battery ageing data: 15 LiCoO2 cells, cycle by cycle
- Tongji/KIT NCA ageing data: 66 18650 cells, cycle by cycle
- Tongji/KIT NCM ageing data: 55 18650 cells, cycle by cycle
- Tongji/KIT NCM+NCA ageing data: 9 18650 cells at three discharge rates
- Michigan VTC6 data: 194 characterisations of 70 aged 18650 cells
- CMU eVTOL battery data: 22 VTC6 cells under aircraft missions
- NASA PCoE battery ageing data: 34 18650 cells, cycle by cycle
- Oxford battery degradation data: 8 Kokam pouch cells, test by test
- UConn LFP ageing data: 64 18650 cells under 11 cycling conditions
- HYDRA ageing data: 32 LG MJ1 18650 cells under ship-like cycling
- REBELION ageing data: 160 Samsung 50E cells, four cycling strategies
- TEMPEST ageing data: a 280 Ah LFP cell over 700 cycles at 1C
- LiBforSecUse ageing data: 34 18650 NMC811 cells, 13 life-cycle tests
- VERSAPRINT cycle data: one Lishen 51 Ah cell, nine cycles
- EVERLASTING ageing data: 28 Samsung 35E cells under drive cycles
- All open battery ageing data on Lemonergy
- How these datasets were imported and checked
- Find and compare battery cells