lemonergy/ data Sign in

Open battery ageing data · CMU eVTOL

CMU eVTOL battery data: 22 VTC6 cells under aircraft missions

Carnegie Mellon University (Bills et al., Scientific Data 2023) put 22 Sony-Murata VTC6 18650 cells of 3.0 Ah through electric-aircraft missions: take-off, cruise and landing at constant power, then a CC-CV charge. A C/5 capacity test ran at the start and after each 50 missions. Each cell had one changed condition: cruise length, power, charge current, end-of-charge voltage or chamber temperature. Lemonergy computed one row per mission or test from the published files. Only the capacity tests measure capacity, so only they are drawn.

Free to download, no account needed. Or read it straight into Python:

import pandas as pd
cycles = pd.read_csv("https://lemonergy.com/data/ageing/cmu-evtol-2023/cycles.csv")
Cells
22 cells, 18650; maker: Sony-Murata, as the article and README name it; the library files the US18650VTC6 under Murata (cell/murata/us18650vtc6)
Chemistry
not stated by the dataset
Nominal capacity
3 Ah, 3.6 V
Rows
23,146, one row each
Test programmes
13
Published by
Carnegie Mellon University
Licence
CC BY 4.0
Files retrieved
2026-11-12

Source: CMU eVTOL battery dataset (22 x Sony-Murata VTC-6 under eVTOL mission cycles), Carnegie Mellon University, doi:10.1184/R1/14226830.v3. Licence: CC BY 4.0.

Cite: Bills, A., Sripad, S., Fredericks, L., Guttenberg, M., Charles, D., Frank, E., Viswanathan, V. A battery dataset for electric vertical takeoff and landing aircraft. Scientific Data 10, 344 (2023). doi:10.1038/s41597-023-02180-5. Data: Bills, A. et al. eVTOL Battery Dataset, Carnegie Mellon University, KiltHub, doi:10.1184/R1/14226830.v3

Licence and how to cite · Data quality · Every source file, by SHA-256

Capacity fade, cycle by cycle

Discharge capacity of each C/5 capacity test, from the tester’s own counter, one coloured line per cell. Missions are partial discharges and are not drawn. Point at a chart to read the values; download them as Excel.

The chart needs JavaScript; every cell’s values are in the table below and in the CSV.

Every cell

First and last discharge capacity of the rows the chart draws, for all 22 cells. Every row of every cell, with all its values, is in the CSV (3.0 MB).

ProgrammeCellRows recordedPoints drawnFirst (Ah)Last (Ah)Last / first
BaselineVAH01847183.0892.51781.5 %
BaselineVAH171,002213.1122.43678.3 %
BaselineVAH27586133.1212.58482.8 %
Cruise 1000 sVAH02625143.1052.55482.3 %
Cruise 1000 sVAH15554113.1252.63984.4 %
Cruise 1000 sVAH22922113.1262.63484.3 %
Cruise 600 sVAH131,041213.0452.35877.4 %
Cruise 600 sVAH261,162243.0532.37277.7 %
Cruise 400 sVAH122,349473.0612.23673.0 %
Power -10 %VAH052,017303.0332.34077.1 %
Power -10 %VAH281,180253.0202.44180.8 %
Power -20 %VAH112,248443.0502.19672.0 %
Charge C/2VAH061,295203.0402.45580.8 %
Charge C/2VAH24801173.0502.46880.9 %
Charge 1.5CVAH16559113.1382.67085.1 %
Charge 1.5CVAH20611133.1402.57682.0 %
End of charge 4.0 VVAH0757863.0342.81392.7 %
End of charge 4.1 VVAH23697153.0212.59986.0 %
Chamber 20 CVAH091,168233.0362.41479.5 %
Chamber 20 CVAH25554133.0272.53083.6 %
Chamber 30 CVAH101,431293.0862.31375.0 %
Chamber 35 CVAH30919193.1382.48379.1 %

Test programmes

The programmes are grouped as the publisher’s page groups them (read 2026-11-12), in our words.

Columns of the CSV

Each VAH##.csv read with battery-data tools/convert_cmu_evtol.py, which maps it to BDF names (current mA to A, QCharge_mA_h and QDischarge_mA_h to Ah, cycleNumber as the tester's cycle count) and computes one row per cycle with tools/dataset_cycles.py: the conventions and cycle summary of tools/cyclers.py (current sign detected from the capacity columns; a cycle is one charge followed by one discharge; capacity integrated from current with cyclers' step_aware_min_boundary rule (docs/36): the trapezoid between two samples of the same tester step (Ns), the smaller of the two currents across a change of Ns, so an interval with a rest on either side carries nothing, and the interval before a cycle's first sample at that sample's current; nothing integrated across a recording gap longer than an hour). Cycles are numbered 1..n per cell; this matches the article's own cycle numbers (its errata and the impedance files put capacity tests at 1, 52, 103, ...). The tester's cycleNumber restarts with each tester file joined into the published file, so it is kept in the label only. Each cycle is labelled from its discharge: 'capacity test [test capacity]' when it discharges only at 0.3-1.0 A (C/5 is 0.6 A) for at least 30 min, never above 5 A, and reaches 2.52 V or below; 'capacity test, stopped above 2.52 V' if it does not reach the cut-off; 'mission [partial]' when it discharges above 5 A and less than 10 min at 0.3-1.0 A; 'other' for anything else; 'overlapping recordings [not a cycle]' when it touches a stretch where two recordings are interleaved sample by sample (more than two sign flips of current above 0.05 A between neighbouring samples, or falls of cycleNumber, with less than an hour between them). The reported capacities are the tester's counters: the largest QCharge_mA_h over the cycle's charging samples and the largest QDischarge_mA_h over its discharging samples. Every file was downloaded from the version 3 record and matched the MD5 the record lists. Values are rounded as printed: Ah to 5 decimals, efficiency and volts to 4, seconds to 0.1.

ColumnUnitMeaning
batch–the cell's test condition, as Table 2 of the article states it (see batches)
cell–cell file name without .csv (VAH##)
cycle–cycle number, 1-based, counted by battery-data (one charge then one discharge); the article's numbering
label–kind of cycle from its discharge (see method), with the tester's own cycleNumber
charge_ahAhcharge integrated from current (cyclers rule; see caveats)
discharge_ahAhdischarge integrated from current (cyclers rule; see caveats)
charge_ah_reportedAhlargest QCharge_mA_h of the cycle's charging samples, in Ah
discharge_ah_reportedAhlargest QDischarge_mA_h of the cycle's discharging samples, in Ah
coulombic_efficiency–discharge_ah / charge_ah (blank when charge_ah is zero)
v_maxVhighest voltage in the cycle
v_minVlowest voltage in the cycle
duration_sslength of the cycle
start_test_time_ssstart of the cycle on the file's time_s axis

Data quality

Overall: All 22 cells are usable for capacity fade from the capacity tests and the tester's counters; none is unusable. 6 cells are usable as they are and 16 usable with caveats: 5 hold stretches of two interleaved recordings (labelled, not cycles), and 11 have publisher errata or a last mission that stops short of the stated end criterion. Integrated with step_aware_min_boundary (docs/36), discharge_ah matches the tester's counter to 0.04 mAh (median) on capacity tests and 3.54 mAh on missions (it was 1.75 and 109.96 mAh with the right-rectangle rule); the *_reported columns remain the tester's own figures.

22 cells checked: 6 usable, 16 usable with caveats, 0 not usable.

CellVerdictWhy
VAH01usablecomplete; protocol, limits and temperatures as stated; no publisher errata; no overlap or gap
VAH02usablecomplete; protocol, limits and temperatures as stated; no publisher errata; no overlap or gap
VAH05usable with caveats473 of 2017 rows are fragments of two interleaved recordings (1 stretch(es), 4.9 h in total); publisher's errata at cycle(s) 1000
VAH06usable with caveats334 of 1295 rows are fragments of two interleaved recordings (1 stretch(es), 92.9 h in total)
VAH07usable with caveats306 of 578 rows are fragments of two interleaved recordings (1 stretch(es), 6.1 h in total)
VAH09usable with caveats361 of 1168 rows are fragments of two interleaved recordings (2 stretch(es), 88.0 h in total); publisher's errata at cycle(s) 64, 92, 154, 691; 1 capacity test stopped above the cut-off
VAH10usable with caveatspublisher's errata at cycle(s) 249, 631, 735, 1151
VAH11usable with caveatspublisher's errata at cycle(s) 817, 1898; 1 capacity test stopped above the cut-off
VAH12usable with caveatslast mission (cycle 2348) ends at 2.861 V and 59.11 C, short of the stated end criterion (2.5 V or 70 C)
VAH13usable with caveatspublisher's errata at cycle(s) 816, 817
VAH15usable with caveatslast mission (cycle 553) ends at 2.6539 V and 61.28 C, short of the stated end criterion (2.5 V or 70 C)
VAH16usable with caveatslast mission (cycle 559) ends at 3.7703 V and 38.03 C, short of the stated end criterion (2.5 V or 70 C)
VAH17usablecomplete; protocol, limits and temperatures as stated; no publisher errata; no overlap or gap
VAH20usablecomplete; protocol, limits and temperatures as stated; no publisher errata; no overlap or gap
VAH22usable with caveats372 of 922 rows are fragments of two interleaved recordings (1 stretch(es), 5.1 h in total)
VAH23usablecomplete; protocol, limits and temperatures as stated; no publisher errata; no overlap or gap
VAH24usablecomplete; protocol, limits and temperatures as stated; no publisher errata; no overlap or gap
VAH25usable with caveatspublisher's errata at cycle(s) 461, 462
VAH26usable with caveatspublisher's errata at cycle(s) 872, 873
VAH27usable with caveatspublisher's errata at cycle(s) 20, 585, 256, 257; cycle 20 holds the unphysical voltage spike the publisher lists (v_max 7.18 V)
VAH28usable with caveatspublisher's errata at cycle(s) 256, 257, 619, 620, 1066, 1067; last mission (cycle 1179) ends at 2.8609 V and 44.53 C, short of the stated end criterion (2.5 V or 70 C); cycle 1066 reaches 4.233 V, at the CV-charge interruption the publisher lists
VAH30usable with caveatslast mission (cycle 918) ends at 2.8321 V and 67.16 C, short of the stated end criterion (2.5 V or 70 C)

Before comparing cells

Licence and how to cite

The values are published under CC BY 4.0, as the source is. Credit it as follows.

Licence history: version 1 of the record (2021) carried CC BY-NC-SA 4.0; versions 2 and 3 (2023) carry CC BY 4.0. These values were computed from the version 3 files, obtained under CC BY 4.0. The cycling files are byte-identical in all three versions.

Version used: version 3 of the record (doi:10.1184/R1/14226830.v3, 2023-04-21). Its cycling files and README are byte-identical (same MD5) to version 2, which the article describes; version 3 adds the impedance files.

Cite: Bills, A., Sripad, S., Fredericks, L., Guttenberg, M., Charles, D., Frank, E., Viswanathan, V. A battery dataset for electric vertical takeoff and landing aircraft. Scientific Data 10, 344 (2023). doi:10.1038/s41597-023-02180-5. Data: Bills, A. et al. eVTOL Battery Dataset, Carnegie Mellon University, KiltHub, doi:10.1184/R1/14226830.v3

Credit: Data: Bills, A., Sripad, S., Fredericks, L., Guttenberg, M., Charles, D., Frank, E., Viswanathan, V., Carnegie Mellon University, eVTOL Battery Dataset, doi:10.1184/R1/14226830.v3, CC BY 4.0; described in Scientific Data 10, 344 (2023). Per-cycle values computed by Lemonergy (battery-data).

Values pinned to battery-data revision e85dd43. The manifest names every source file by its SHA-256; the CSV’s own SHA-256 is 27d44762acdde0708e0d831c6300e7407f90474034cf23fb8f8a4000ca3af165.