Open battery ageing data · CMU eVTOL
CMU eVTOL battery data: 22 VTC6 cells under aircraft missions
Carnegie Mellon University (Bills et al., Scientific Data 2023) put 22 Sony-Murata VTC6 18650 cells of 3.0 Ah through electric-aircraft missions: take-off, cruise and landing at constant power, then a CC-CV charge. A C/5 capacity test ran at the start and after each 50 missions. Each cell had one changed condition: cruise length, power, charge current, end-of-charge voltage or chamber temperature. Lemonergy computed one row per mission or test from the published files. Only the capacity tests measure capacity, so only they are drawn.
Download every row (CSV, 3.0 MB)Manifest (JSON): files, hashes, unitsChart and Excel downloadOriginal dataset
Free to download, no account needed. Or read it straight into Python:
import pandas as pd
cycles = pd.read_csv("https://lemonergy.com/data/ageing/cmu-evtol-2023/cycles.csv")- Cells
- 22 cells, 18650; maker: Sony-Murata, as the article and README name it; the library files the US18650VTC6 under Murata (cell/murata/us18650vtc6)
- Chemistry
- not stated by the dataset
- Nominal capacity
- 3 Ah, 3.6 V
- Rows
- 23,146, one row each
- Test programmes
- 13
- Published by
- Carnegie Mellon University
- Licence
- CC BY 4.0
- Files retrieved
- 2026-11-12
Source: CMU eVTOL battery dataset (22 x Sony-Murata VTC-6 under eVTOL mission cycles), Carnegie Mellon University, doi:10.1184/R1/14226830.v3. Licence: CC BY 4.0.
Cite: Bills, A., Sripad, S., Fredericks, L., Guttenberg, M., Charles, D., Frank, E., Viswanathan, V. A battery dataset for electric vertical takeoff and landing aircraft. Scientific Data 10, 344 (2023). doi:10.1038/s41597-023-02180-5. Data: Bills, A. et al. eVTOL Battery Dataset, Carnegie Mellon University, KiltHub, doi:10.1184/R1/14226830.v3
Licence and how to cite · Data quality · Every source file, by SHA-256
Capacity fade, cycle by cycle
Discharge capacity of each C/5 capacity test, from the tester’s own counter, one coloured line per cell. Missions are partial discharges and are not drawn. Point at a chart to read the values; download them as Excel.
The chart needs JavaScript; every cell’s values are in the table below and in the CSV.
Point at or touch a chart to read every cell’s value at that cycle. Drag across it with a mouse to zoom in. Click a line, or a cell’s name in the legend or table, to show that cell on its own; the others turn grey.Touch a chart to read the values at a cycle. Tap a cell’s name in the legend or the table to show it on its own; the others turn grey.
| Cell | Rows recorded | Points drawn | First (Ah) | Last (Ah) | Last / first |
|---|
Every cell
First and last discharge capacity of the rows the chart draws, for all 22 cells. Every row of every cell, with all its values, is in the CSV (3.0 MB).
| Programme | Cell | Rows recorded | Points drawn | First (Ah) | Last (Ah) | Last / first |
|---|---|---|---|---|---|---|
| Baseline | VAH01 | 847 | 18 | 3.089 | 2.517 | 81.5 % |
| Baseline | VAH17 | 1,002 | 21 | 3.112 | 2.436 | 78.3 % |
| Baseline | VAH27 | 586 | 13 | 3.121 | 2.584 | 82.8 % |
| Cruise 1000 s | VAH02 | 625 | 14 | 3.105 | 2.554 | 82.3 % |
| Cruise 1000 s | VAH15 | 554 | 11 | 3.125 | 2.639 | 84.4 % |
| Cruise 1000 s | VAH22 | 922 | 11 | 3.126 | 2.634 | 84.3 % |
| Cruise 600 s | VAH13 | 1,041 | 21 | 3.045 | 2.358 | 77.4 % |
| Cruise 600 s | VAH26 | 1,162 | 24 | 3.053 | 2.372 | 77.7 % |
| Cruise 400 s | VAH12 | 2,349 | 47 | 3.061 | 2.236 | 73.0 % |
| Power -10 % | VAH05 | 2,017 | 30 | 3.033 | 2.340 | 77.1 % |
| Power -10 % | VAH28 | 1,180 | 25 | 3.020 | 2.441 | 80.8 % |
| Power -20 % | VAH11 | 2,248 | 44 | 3.050 | 2.196 | 72.0 % |
| Charge C/2 | VAH06 | 1,295 | 20 | 3.040 | 2.455 | 80.8 % |
| Charge C/2 | VAH24 | 801 | 17 | 3.050 | 2.468 | 80.9 % |
| Charge 1.5C | VAH16 | 559 | 11 | 3.138 | 2.670 | 85.1 % |
| Charge 1.5C | VAH20 | 611 | 13 | 3.140 | 2.576 | 82.0 % |
| End of charge 4.0 V | VAH07 | 578 | 6 | 3.034 | 2.813 | 92.7 % |
| End of charge 4.1 V | VAH23 | 697 | 15 | 3.021 | 2.599 | 86.0 % |
| Chamber 20 C | VAH09 | 1,168 | 23 | 3.036 | 2.414 | 79.5 % |
| Chamber 20 C | VAH25 | 554 | 13 | 3.027 | 2.530 | 83.6 % |
| Chamber 30 C | VAH10 | 1,431 | 29 | 3.086 | 2.313 | 75.0 % |
| Chamber 35 C | VAH30 | 919 | 19 | 3.138 | 2.483 | 79.1 % |
Test programmes
- Baseline. VAH01, VAH17, VAH27: baseline mission (Table 2: 'Baseline mission'). Table 1: take-off 54 W for 75 s, cruise 16 W for 800 s, landing 54 W for 105 s, rest until below 27 C, CC charge at 1C to 4.2 V, CV at 4.2 V until the current falls below C/30, rest until below 35 C. Drawn: C/5 capacity tests (0.6 A, 4.2 V to 2.5 V).
- Cruise 1000 s. VAH02, VAH15, VAH22: cruise time 1000 s; otherwise baseline. Drawn: C/5 capacity tests (0.6 A, 4.2 V to 2.5 V).
- Cruise 600 s. VAH13, VAH26: cruise time 600 s; otherwise baseline. Drawn: C/5 capacity tests (0.6 A, 4.2 V to 2.5 V).
- Cruise 400 s. VAH12: cruise time 400 s; otherwise baseline. Drawn: C/5 capacity tests (0.6 A, 4.2 V to 2.5 V).
- Power -10 %. VAH05, VAH28: power reduced by 10 percent for take-off, cruise and landing; otherwise baseline. Drawn: C/5 capacity tests (0.6 A, 4.2 V to 2.5 V).
- Power -20 %. VAH11: power reduced by 20 % for take-off, cruise and landing; otherwise baseline. Drawn: C/5 capacity tests (0.6 A, 4.2 V to 2.5 V).
- Charge C/2. VAH06, VAH24: CC-CV charge at C/2 CC, C/30 CV cut-off; otherwise baseline. Drawn: C/5 capacity tests (0.6 A, 4.2 V to 2.5 V).
- Charge 1.5C. VAH16, VAH20: CC-CV charge at 1.5C CC, C/30 CV cut-off; otherwise baseline. (The README says 'reduced to 1.5C'; the baseline is 1C, and the files charge at 4.49 A, so 1.5C is an increase.). Drawn: C/5 capacity tests (0.6 A, 4.2 V to 2.5 V).
- End of charge 4.0 V. VAH07: end of charge voltage 4.0 V; otherwise baseline. Drawn: C/5 capacity tests (0.6 A, 4.2 V to 2.5 V).
- End of charge 4.1 V. VAH23: end of charge voltage 4.1 V; otherwise baseline. Drawn: C/5 capacity tests (0.6 A, 4.2 V to 2.5 V).
- Chamber 20 C. VAH09, VAH25: thermal chamber at 20 C; otherwise baseline. Drawn: C/5 capacity tests (0.6 A, 4.2 V to 2.5 V).
- Chamber 30 C. VAH10: thermal chamber at 30 C; otherwise baseline. Drawn: C/5 capacity tests (0.6 A, 4.2 V to 2.5 V).
- Chamber 35 C. VAH30: thermal chamber at 35 C; otherwise baseline. Drawn: C/5 capacity tests (0.6 A, 4.2 V to 2.5 V).
The programmes are grouped as the publisher’s page groups them (read 2026-11-12), in our words.
Columns of the CSV
Each VAH##.csv read with battery-data tools/convert_cmu_evtol.py, which maps it to BDF names (current mA to A, QCharge_mA_h and QDischarge_mA_h to Ah, cycleNumber as the tester's cycle count) and computes one row per cycle with tools/dataset_cycles.py: the conventions and cycle summary of tools/cyclers.py (current sign detected from the capacity columns; a cycle is one charge followed by one discharge; capacity integrated from current with cyclers' step_aware_min_boundary rule (docs/36): the trapezoid between two samples of the same tester step (Ns), the smaller of the two currents across a change of Ns, so an interval with a rest on either side carries nothing, and the interval before a cycle's first sample at that sample's current; nothing integrated across a recording gap longer than an hour). Cycles are numbered 1..n per cell; this matches the article's own cycle numbers (its errata and the impedance files put capacity tests at 1, 52, 103, ...). The tester's cycleNumber restarts with each tester file joined into the published file, so it is kept in the label only. Each cycle is labelled from its discharge: 'capacity test [test capacity]' when it discharges only at 0.3-1.0 A (C/5 is 0.6 A) for at least 30 min, never above 5 A, and reaches 2.52 V or below; 'capacity test, stopped above 2.52 V' if it does not reach the cut-off; 'mission [partial]' when it discharges above 5 A and less than 10 min at 0.3-1.0 A; 'other' for anything else; 'overlapping recordings [not a cycle]' when it touches a stretch where two recordings are interleaved sample by sample (more than two sign flips of current above 0.05 A between neighbouring samples, or falls of cycleNumber, with less than an hour between them). The reported capacities are the tester's counters: the largest QCharge_mA_h over the cycle's charging samples and the largest QDischarge_mA_h over its discharging samples. Every file was downloaded from the version 3 record and matched the MD5 the record lists. Values are rounded as printed: Ah to 5 decimals, efficiency and volts to 4, seconds to 0.1.
| Column | Unit | Meaning |
|---|---|---|
batch | – | the cell's test condition, as Table 2 of the article states it (see batches) |
cell | – | cell file name without .csv (VAH##) |
cycle | – | cycle number, 1-based, counted by battery-data (one charge then one discharge); the article's numbering |
label | – | kind of cycle from its discharge (see method), with the tester's own cycleNumber |
charge_ah | Ah | charge integrated from current (cyclers rule; see caveats) |
discharge_ah | Ah | discharge integrated from current (cyclers rule; see caveats) |
charge_ah_reported | Ah | largest QCharge_mA_h of the cycle's charging samples, in Ah |
discharge_ah_reported | Ah | largest QDischarge_mA_h of the cycle's discharging samples, in Ah |
coulombic_efficiency | – | discharge_ah / charge_ah (blank when charge_ah is zero) |
v_max | V | highest voltage in the cycle |
v_min | V | lowest voltage in the cycle |
duration_s | s | length of the cycle |
start_test_time_s | s | start of the cycle on the file's time_s axis |
Data quality
Overall: All 22 cells are usable for capacity fade from the capacity tests and the tester's counters; none is unusable. 6 cells are usable as they are and 16 usable with caveats: 5 hold stretches of two interleaved recordings (labelled, not cycles), and 11 have publisher errata or a last mission that stops short of the stated end criterion. Integrated with step_aware_min_boundary (docs/36), discharge_ah matches the tester's counter to 0.04 mAh (median) on capacity tests and 3.54 mAh on missions (it was 1.75 and 109.96 mAh with the right-rectangle rule); the *_reported columns remain the tester's own figures.
22 cells checked: 6 usable, 16 usable with caveats, 0 not usable.
| Cell | Verdict | Why |
|---|---|---|
| VAH01 | usable | complete; protocol, limits and temperatures as stated; no publisher errata; no overlap or gap |
| VAH02 | usable | complete; protocol, limits and temperatures as stated; no publisher errata; no overlap or gap |
| VAH05 | usable with caveats | 473 of 2017 rows are fragments of two interleaved recordings (1 stretch(es), 4.9 h in total); publisher's errata at cycle(s) 1000 |
| VAH06 | usable with caveats | 334 of 1295 rows are fragments of two interleaved recordings (1 stretch(es), 92.9 h in total) |
| VAH07 | usable with caveats | 306 of 578 rows are fragments of two interleaved recordings (1 stretch(es), 6.1 h in total) |
| VAH09 | usable with caveats | 361 of 1168 rows are fragments of two interleaved recordings (2 stretch(es), 88.0 h in total); publisher's errata at cycle(s) 64, 92, 154, 691; 1 capacity test stopped above the cut-off |
| VAH10 | usable with caveats | publisher's errata at cycle(s) 249, 631, 735, 1151 |
| VAH11 | usable with caveats | publisher's errata at cycle(s) 817, 1898; 1 capacity test stopped above the cut-off |
| VAH12 | usable with caveats | last mission (cycle 2348) ends at 2.861 V and 59.11 C, short of the stated end criterion (2.5 V or 70 C) |
| VAH13 | usable with caveats | publisher's errata at cycle(s) 816, 817 |
| VAH15 | usable with caveats | last mission (cycle 553) ends at 2.6539 V and 61.28 C, short of the stated end criterion (2.5 V or 70 C) |
| VAH16 | usable with caveats | last mission (cycle 559) ends at 3.7703 V and 38.03 C, short of the stated end criterion (2.5 V or 70 C) |
| VAH17 | usable | complete; protocol, limits and temperatures as stated; no publisher errata; no overlap or gap |
| VAH20 | usable | complete; protocol, limits and temperatures as stated; no publisher errata; no overlap or gap |
| VAH22 | usable with caveats | 372 of 922 rows are fragments of two interleaved recordings (1 stretch(es), 5.1 h in total) |
| VAH23 | usable | complete; protocol, limits and temperatures as stated; no publisher errata; no overlap or gap |
| VAH24 | usable | complete; protocol, limits and temperatures as stated; no publisher errata; no overlap or gap |
| VAH25 | usable with caveats | publisher's errata at cycle(s) 461, 462 |
| VAH26 | usable with caveats | publisher's errata at cycle(s) 872, 873 |
| VAH27 | usable with caveats | publisher's errata at cycle(s) 20, 585, 256, 257; cycle 20 holds the unphysical voltage spike the publisher lists (v_max 7.18 V) |
| VAH28 | usable with caveats | publisher's errata at cycle(s) 256, 257, 619, 620, 1066, 1067; last mission (cycle 1179) ends at 2.8609 V and 44.53 C, short of the stated end criterion (2.5 V or 70 C); cycle 1066 reaches 4.233 V, at the CV-charge interruption the publisher lists |
| VAH30 | usable with caveats | last mission (cycle 918) ends at 2.8321 V and 67.16 C, short of the stated end criterion (2.5 V or 70 C) |
Before comparing cells
- charge_ah and discharge_ah are integrated with tools/cyclers.py's step_aware_min_boundary rule (regenerated 17 November 2026, docs/36; first published with the right-rectangle rule). Against the tester's counters (charge_ah_reported, discharge_ah_reported): capacity tests discharge median 0.04 mAh (95th percentile 0.1 mAh, 444 of 445 within 1 mAh), missions discharge median 3.54 mAh under the counter (95th percentile 4.89 mAh), mission charge median 0.77 mAh (95th percentile 1.49 mAh), capacity-test charge median 4.21 mAh over the counter (95th percentile 12.35 mAh). Before, the right-rectangle rule credited the first take-off sample with the 30 s rest interval before it at about 15 A, so mission discharge_ah was 109.96 mAh above the counter (median) and mission charge 36.76 mAh below it; capacity tests were 1.75 mAh (discharge) and 2.12 mAh (charge) off. What is left: each mission step starts with a sample 2 ms in, caught while the current is still settling, and the trapezoid from it to the next sample misses part of the step change; where missions are logged every second that costs 0.30 mAh (median, 642 missions), where they are logged every 10 s 3.57 mAh (20,209 missions). On charge, 98 % of mission charges log their first sample 30 s into the charge, so the interval before it belongs to the charge and the rule takes it in; capacity-test charges (99.6 %) log it at the start, with the counter at zero, and the same interval adds charge that did not flow: about 4 mAh (median) where the capacity-test charge is logged every 10 s, about 12 mAh in the nine cells where it is logged every 30 s (VAH11, VAH12, VAH15, VAH16, VAH17, VAH20, VAH22, VAH27, VAH30). The rule is one per folder, so this is the trade-off: the coulombic efficiency of capacity tests is not meaningful anyway (see below). For a capacity, the tester's discharge_ah_reported remains the reference; discharge_ah of capacity tests agrees with it to 0.1 mAh. The overlap fragments are not cycles under any rule.
- Licence history: version 1 of the record (2021) carried CC BY-NC-SA 4.0; versions 2 and 3 (2023) carry CC BY 4.0. These values were computed from the version 3 files, obtained under CC BY 4.0. The cycling files are byte-identical in all three versions.
- Only rows labelled 'capacity test [test capacity]' measure capacity (C/5 from 4.2 V to 2.5 V). A 'mission [partial]' is a constant-power partial discharge (take-off, cruise, landing), and its discharge is a mission's charge throughput, not a capacity. Each capacity test's charge is the CC-CV charge before it, which refills the previous mission, so its coulombic efficiency is not meaningful; nor is the efficiency of the mission that follows a capacity test.
- Two recordings are interleaved sample by sample in 5 cells (VAH05, VAH06, VAH07, VAH09, VAH22): current alternates between a charge and a discharge from one sample to the next, and the tester's cycleNumber jumps back and forth. One cell cannot do both, so one of the two recordings is not this cell's, or its clock is shifted; the file does not say which. Nothing is dropped or re-ordered. The cycles that touch such a stretch are fragments and are labelled 'overlapping recordings [not a cycle]' (1846 rows); their values are not cycle values. The stretches, in seconds of test time, are under overlap_windows_s of each source file. The publisher does not list them.
- The publisher's errata (article and README) are found at the cycle numbers they give, in this numbering: VAH09 154 and VAH11 817 are capacity tests stopped above the cut-off; VAH25 461/462 and VAH28 256/257 are two capacity tests in a row; VAH27 cycle 20 holds the 7.18 V spike; VAH28 cycle 1066 reaches 4.233 V; VAH10's data stop is at cycle 248, as the README says (the article says 249). Each is listed per cell under quality.cells.<cell>.errata. They are kept as recorded.
- The last mission of most cells ends at 2.5 V and is shorter than the others; its discharge is not comparable with the rest. In VAH12, VAH15, VAH16, VAH28 and VAH30 the last mission ends above 2.52 V and below 70 C, so the file stops before the stated end criterion; VAH15 then ends with a charge (its last row, labelled other).
- The 2 cycles labelled 'other': VAH06 cycle 767 runs into the start of that cell's overlapping recordings (a capacity test and the start of a mission with no charge between); VAH15 cycle 554 is a final charge with no discharge.
- Capacity tests charge to 4.2 V in every cell, also in VAH07 (4.0 V missions) and VAH23 (4.1 V missions), so v_max of those rows is 4.2 V by design.
- Counts: 23146 rows; 20851 missions, 445 capacity tests, 2 capacity tests stopped early, 2 other, 1846 overlap fragments. Without the fragments, 21300 cycles; the article states 21,392 (difference -92). VAH12's last mission is cycle 2,348, the cycle life the article gives; VAH07, whose cycle life the article gives as 275, has 272 cycles outside its overlap stretch.
- Article inconsistencies, reported and not acted on: its text gives VAH12 'a power reduction of 20%', but Table 2 and the files give VAH12 a 400 s cruise at full power (missions at 53.6 W), and VAH11 the 20 % reduction (42.9 W); its column list says QCharge_mA_h is 'during discharge in watt-hours' (the README: charge supplied during charge, in mAh); the README says the charge current of VAH16 and VAH20 is 'reduced to 1.5C', which is an increase from the 1C baseline; the article says the internal resistance was calculated 'for each cell', but the record holds 21 impedance files (none for VAH26).
- Not stated by the dataset, so not filed: the cell chemistry, the ambient temperature of cells without a chamber setting, and the charge rate of the capacity tests (the files show 1.49 A, C/2).
- Capacity here is the tester's own counter (discharge_ah_reported), as before. The library recomputed its integrated columns on 17 November 2026 with a rule chosen to match how this tester logs a change of step: the integrated discharge of a capacity test now agrees with the counter to a median 0.04 mAh, and a mission's to a median 3.5 mAh (it was about 110 mAh), so a mission's coulombic efficiency reads about 1.00, not 1.09. The same rule counts the interval before a cycle's first sample, which is charge in a mission but rest before a capacity test, so a capacity test's charge is now a median 4.2 mAh over the counter (it was 2.1 mAh under); that efficiency was never meaningful, as the charge refills the previous mission. VAH09 cycle 1040, a capacity test next to two interleaved recordings, is wrong under any rule; use its counter. The chart draws the counter, so its values did not change.
Licence and how to cite
The values are published under CC BY 4.0, as the source is. Credit it as follows.
Licence history: version 1 of the record (2021) carried CC BY-NC-SA 4.0; versions 2 and 3 (2023) carry CC BY 4.0. These values were computed from the version 3 files, obtained under CC BY 4.0. The cycling files are byte-identical in all three versions.
Version used: version 3 of the record (doi:10.1184/R1/14226830.v3, 2023-04-21). Its cycling files and README are byte-identical (same MD5) to version 2, which the article describes; version 3 adds the impedance files.
Cite: Bills, A., Sripad, S., Fredericks, L., Guttenberg, M., Charles, D., Frank, E., Viswanathan, V. A battery dataset for electric vertical takeoff and landing aircraft. Scientific Data 10, 344 (2023). doi:10.1038/s41597-023-02180-5. Data: Bills, A. et al. eVTOL Battery Dataset, Carnegie Mellon University, KiltHub, doi:10.1184/R1/14226830.v3
Credit: Data: Bills, A., Sripad, S., Fredericks, L., Guttenberg, M., Charles, D., Frank, E., Viswanathan, V., Carnegie Mellon University, eVTOL Battery Dataset, doi:10.1184/R1/14226830.v3, CC BY 4.0; described in Scientific Data 10, 344 (2023). Per-cycle values computed by Lemonergy (battery-data).
Values pinned to battery-data revision e85dd43. The manifest names every source file by its SHA-256; the CSV’s own SHA-256 is 27d44762acdde0708e0d831c6300e7407f90474034cf23fb8f8a4000ca3af165.
Related
- XJTU battery ageing data: 55 Lishen 18650 cells, cycle by cycle
- CALCE CS2 battery ageing data: 15 LiCoO2 cells, cycle by cycle
- Tongji/KIT NCA ageing data: 66 18650 cells, cycle by cycle
- Tongji/KIT NCM ageing data: 55 18650 cells, cycle by cycle
- Tongji/KIT NCM+NCA ageing data: 9 18650 cells at three discharge rates
- Michigan VTC6 data: 194 characterisations of 70 aged 18650 cells
- NASA PCoE battery ageing data: 34 18650 cells, cycle by cycle
- Oxford battery degradation data: 8 Kokam pouch cells, test by test
- UConn LFP ageing data: 64 18650 cells under 11 cycling conditions
- HYDRA ageing data: 32 LG MJ1 18650 cells under ship-like cycling
- REBELION ageing data: 160 Samsung 50E cells, four cycling strategies
- TEMPEST ageing data: a 280 Ah LFP cell over 700 cycles at 1C
- LiBforSecUse ageing data: 34 18650 NMC811 cells, 13 life-cycle tests
- VERSAPRINT cycle data: one Lishen 51 Ah cell, nine cycles
- EVERLASTING ageing data: 28 Samsung 35E cells under drive cycles
- FreeTwinEV module data: four Molicel P45B cells in parallel, 14 runs
- All open battery ageing data on Lemonergy
- How these datasets were imported and checked
- Find and compare battery cells