TEMPEST ageing data: a 280 Ah LFP cell over 700 cycles at 1C

The TEMPEST cell dataset (Gray and Vagg, University of Bath, for the EU project TEMPEST, 2026) tested a 280 Ah prismatic LFP cell that the record calls the “LIC” cell. The record does not name its maker or its model. It holds two test series: five capacity tests at 15 to 35 °C, and an ageing test of 700 cycles at 1C (280 A) in blocks of 50. Before the first block and after each, a reference test measured the capacity at 0.1C and took 10 s pulses at 50 % state of charge. The record does not say whether one physical cell ran both series. Lemonergy computed one row per cycle or test from the published files. Only the reference tests are drawn: the 1C cycles are logged every 10 s, too coarse to read capacity fade from.

Free to download, no account needed. Or read it straight into Python:

import pandas as pd
cycles = pd.read_csv("https://lemonergy.com/data/ageing/tempest-lic-280ah-2026/cycles.csv")
Cells
1 cell type in 2 test series, prismatic (the record: '280 Ah prismatic LFP cell'); maker not stated
Chemistry
LFP (as the record names the cell)
Nominal capacity
280 Ah
Rows
720, one row each
Test programmes
2
Published by
University of Bath, for the EU project TEMPEST
Licence
CC BY 4.0
Files retrieved
2026-11-14

Source: 280 Ah prismatic LFP cell: characterisation and aging data (TEMPEST 'LIC' cell; capacity tests, 1C ageing cycles and reference tests), University of Bath, for the EU project TEMPEST, doi:10.5281/zenodo.20813753. Licence: CC BY 4.0.

Cite: Gray, R., Vagg, C. 280 Ah prismatic LFP cell: characterisation and aging data. Zenodo (2026). doi:10.5281/zenodo.20813753

Licence and how to cite · Data quality · Every source file, by SHA-256

Capacity fade, reference test by reference test

Discharge capacity of each 0.1C reference test, against the 1C cycles run before it. The 1C ageing cycles and the five capacity tests at 15 to 35 °C are in the CSV, not drawn. Point at a chart to read the values; download them as Excel.

The chart needs JavaScript; every cell’s values are in the table below and in the CSV.

Every cell

First and last discharge capacity of the rows the chart draws, for both test series. Every row of every cell, with all its values, is in the CSV (129 kB).

ProgrammeCellRows (cycles and tests)Points drawnFirst (Ah)Last (Ah)Last / first
ageingLIC-ageing71515301.578280.25992.9 %
characterisationLIC-characterisation5not drawn–––

Test programmes

Columns of the CSV

Read with battery-data tools/convert_tempest_lic.py from the two zips, without unpacking. A step is a run of samples of one kind: charge (current above +0.5 A), discharge (below -0.5 A) or rest. Charge and discharge are integrated per step as each sample's current over the interval since the sample before it, the step's first sample included (the tools/cyclers.py rule right_rectangle_boundary, applied per step); this rule reproduces 19 of the 20 capacities the publishers list to 5e-06 Ah or better (the other is under gates.differ and in the caveats). A row is a charge step followed by the next discharge step of the same kind: a 1C charge with a 1C discharge (ageing cycle), or a full 0.1C charge to 3.65 V with a 0.1C discharge to 2.5 V (capacity test). The six 10 s pulses before each capacity test of the ageing file belong to its reference-test row. Other steps are counted, not made into rows (unpaired_steps under source_files). Values rounded: Ah to 5 decimals, volts and efficiency to 4 and 5, mOhm to 4, degC to 2.

ColumnUnitMeaning
batch–'characterisation' (the five capacity tests at 15-35 °C, capacity_hppc_entropy.zip) or 'ageing' (aging.zip)
cell–the test series: 'LIC-characterisation' or 'LIC-ageing'. The record does not say whether both used the same physical cell
cycle–row number within the cell, 1-based, in time order (characterisation: one per temperature, 15 to 35 °C)
label–what the row is (capacity test at a temperature, ageing cycle at 1C, or the capacity test of a reference test), with each step's C-rate (of 280 Ah), current, CC or CC-CV and end voltage as the data show
cycles_1c_before–ageing rows: 1C cycles completed before this row; for a reference test this is the publishers' Total_cycles (0, 50, ... 700)
temperature_cdegCcharacterisation rows: the test temperature, as the file name and readme state ('XXC_capacity ... where XX is the temperature in degC'); blank for ageing rows, whose test temperature the record does not state
charge_ahAhcharge step integrated from current: each sample's current over the interval since the sample before it, the step's first sample included
discharge_ahAhdischarge step integrated the same way
discharge_ah_reportedAhthe publishers' capacity for this test: LIC_capacity_analysis.csv (characterisation) or LIC_aging_analysed.csv Capacity_Ah (reference tests); blank for 1C ageing cycles
coulombic_efficiency–discharge_ah / charge_ah
v_maxVhighest voltage in the charge and discharge steps
v_minVlowest voltage in the charge and discharge steps
duration_ssfrom the first sample of the charge step to the last sample of the discharge step
start_test_time_ssfirst sample of the charge step, on the file's own clock (each characterisation file starts its own)
surface_temp_min_cdegClowest cell-surface temperature during the charge and discharge steps: the middle of the largest face (ageing: midT; characterisation: Temperature_K converted)
surface_temp_max_cdegChighest cell-surface temperature during the charge and discharge steps, same sensor
edge_temp_max_cdegCageing rows: highest temperature at the edge sensor (largest face, 10 % of the distance from the top; edgeT); blank for characterisation rows, whose files have one sensor
dcir_dis_02c_10s_mohmmOhmreference tests: 10 s discharge pulse at 0.2C (56 A) at 50 % SoC: |voltage at the pulse's last sample - voltage of the last rest sample before it| / mean pulse current; computed by Lemonergy
dcir_cha_02c_10s_mohmmOhmreference tests: 10 s charge pulse at 0.2C (56 A) at 50 % SoC: |voltage at the pulse's last sample - voltage of the last rest sample before it| / mean pulse current; computed by Lemonergy
dcir_dis_05c_10s_mohmmOhmreference tests: 10 s discharge pulse at 0.5C (140 A) at 50 % SoC: |voltage at the pulse's last sample - voltage of the last rest sample before it| / mean pulse current; computed by Lemonergy
dcir_cha_05c_10s_mohmmOhmreference tests: 10 s charge pulse at 0.5C (140 A) at 50 % SoC: |voltage at the pulse's last sample - voltage of the last rest sample before it| / mean pulse current; computed by Lemonergy
dcir_dis_1c_10s_mohmmOhmreference tests: 10 s discharge pulse at 1.0C (280 A) at 50 % SoC: |voltage at the pulse's last sample - voltage of the last rest sample before it| / mean pulse current; computed by Lemonergy
dcir_cha_1c_10s_mohmmOhmreference tests: 10 s charge pulse at 1.0C (280 A) at 50 % SoC: |voltage at the pulse's last sample - voltage of the last rest sample before it| / mean pulse current; computed by Lemonergy
ohmic_resistance_mohm_reportedmOhmreference tests: the publishers' Ohmic_res_Ohm (LIC_aging_analysed.csv, 'calculated from reference pulse test between blocks (1C discharge pulse)'), in mOhm; the record does not say at what time after the pulse start it is read

Data quality

No per-cell quality verdict was recorded for this dataset. Read the caveats below before comparing cells.

Before comparing cells

Licence and how to cite

The values are published under CC BY 4.0, as the source is. Credit it as follows.

Cite: Gray, R., Vagg, C. 280 Ah prismatic LFP cell: characterisation and aging data. Zenodo (2026). doi:10.5281/zenodo.20813753

Credit: Data: Gray, R., Vagg, C. (University of Bath), EU project TEMPEST (Horizon Europe grant 101103681; UKRI 10075481), doi:10.5281/zenodo.20813753, CC BY 4.0. Per-cycle values computed by Lemonergy (battery-data).

Values pinned to battery-data revision e85dd43. The manifest names every source file by its SHA-256; the CSV’s own SHA-256 is ba25d6bdcb1f0e04d5c5d021304555125057e8a569331dde66eeeaf24fe80ca4.