Open battery ageing data · LiBforSecUse 18650
LiBforSecUse ageing data: 34 18650 NMC811 cells, 13 life-cycle tests
The LiBforSecUse data release (Chan et al., for the EMPIR project LiBforSecUse, 17IND10, 2022) holds life-cycle tests of 34 commercial 18650 cells of 3 Ah, with an NMC811 cathode and a silicon-graphite anode. Six laboratories ran them: PTB, NPL, KIT, Aalto University, the National Institute of Chemistry (Slovenia) and JRC. All cells came from one supplier and batch; the release does not name the maker or the model. Thirteen tests cycled them at 5 to 45 °C over 30 to 100 % of their charge. At each check-up the record gives the capacity at 1.25 A and 23 °C, and impedance spectra at several states of charge. Lemonergy filed one row per check-up from the published file.
Download every check-up (CSV, 223 kB)Manifest (JSON): files, hashes, unitsChart and Excel downloadOriginal dataset
Free to download, no account needed. Or read it straight into Python:
import pandas as pd
cycles = pd.read_csv("https://lemonergy.com/data/ageing/libforsecuse-18650-2022/cycles.csv")- Cells
- 34 cells, 18650 (the release: 'cylindrical 18650 format'); maker not stated
- Chemistry
- NMC811 / silicon-graphite (the release: 'NMC811-silicon/graphite chemistry (NMC811 = LiNi0.8Co0.1Mn0.1O2)')
- Nominal capacity
- 3 Ah
- Check-ups
- 966, one row each
- Test programmes
- 13
- Published by
- PTB, NPL, KIT, Aalto University, National Institute of Chemistry (Slovenia) and JRC, for the EMPIR project LiBforSecUse (17IND10)
- Licence
- CC BY 4.0
- Files retrieved
- 2026-11-14
Source: LiBforSecUse Data Release: life-cycle tests of commercial 18650 cells (check-ups: capacity and EIS), PTB, NPL, KIT, Aalto University, National Institute of Chemistry (Slovenia) and JRC, for the EMPIR project LiBforSecUse (17IND10), doi:10.5281/zenodo.6418665. Licence: CC BY 4.0.
Cite: Chan, H. S., Dickinson, E., Fedorovskaya, E., Gaberšček, M., Heins, T. P., Meddings, N., Lee, Y. Y., Moškon, J., Park, J., Ruiz, V., Seitz, S. LiBforSecUse Data Release - Impedance spectra of life cycle tests of commercial 18650 cells, V2. Zenodo (2022). doi:10.5281/zenodo.6418665
Licence and how to cite · Data quality · Every source file, by SHA-256
Capacity fade, check-up by check-up
Capacity at each check-up (1.25 A at 23 °C), against the cycles run before it, one coloured line per cell, one test at a time. Point at a chart to read the values; download them as Excel.
The chart needs JavaScript; every cell’s values are in the table below and in the CSV.
Point at or touch a chart to read every cell’s value at that cycle. Drag across it with a mouse to zoom in. Click a line, or a cell’s name in the legend or table, to show that cell on its own; the others turn grey.Touch a chart to read the values at a cycle. Tap a cell’s name in the legend or the table to show it on its own; the others turn grey.
| Cell | Check-ups | Points drawn | First (Ah) | Last (Ah) | Last / first |
|---|
Every cell
First and last discharge capacity of the check-ups the chart draws, for all 34 cells. Every row of every cell, with all its values, is in the CSV (223 kB).
| Programme | Cell | Check-ups | Points drawn | First (Ah) | Last (Ah) | Last / first |
|---|---|---|---|---|---|---|
| LCT 1_01: 45 °C, SOC 0-100 % (DOD 100 %), 4 A | Inst5-15 | 27 | 26 | 2.665 | 2.054 | 77.1 % |
| LCT 1_01: 45 °C, SOC 0-100 % (DOD 100 %), 4 A | Inst5-16 | 27 | 26 | 2.712 | 2.055 | 75.8 % |
| LCT 1_01: 45 °C, SOC 0-100 % (DOD 100 %), 4 A | Inst5-17 | 27 | 26 | 2.664 | 1.544 | 58.0 % |
| LCT 1_01: 45 °C, SOC 0-100 % (DOD 100 %), 4 A | Inst5-18 | 27 | 26 | 2.701 | 2.009 | 74.4 % |
| LCT 1_02: 45 °C, SOC 0-100 % (DOD 100 %), 4 A | Inst1-04 | 25 | 25 | 2.696 | 2.160 | 80.1 % |
| LCT 1_02: 45 °C, SOC 0-100 % (DOD 100 %), 4 A | Inst1-05 | 46 | 46 | 2.696 | 0.824 | 30.6 % |
| LCT 1_02: 45 °C, SOC 0-100 % (DOD 100 %), 4 A | Inst1-06 | 43 | 42 | 2.688 | 1.347 | 50.1 % |
| LCT 1_03: 45 °C, SOC 0-100 % (DOD 100 %), 4 A | Inst6-11 | 17 | 17 | 2.524 | 1.994 | 79.0 % |
| LCT 1_03: 45 °C, SOC 0-100 % (DOD 100 %), 4 A | Inst6-12 | 12 | 12 | 2.511 | 2.027 | 80.7 % |
| LCT 1_04: 45 °C, SOC 0-100 % (DOD 100 %), 4 A | Inst2-06 | 34 | 34 | 2.760 | 1.476 | 53.5 % |
| LCT 1_04: 45 °C, SOC 0-100 % (DOD 100 %), 4 A | Inst2-07 | 34 | 34 | 2.759 | 1.536 | 55.7 % |
| LCT 1_05: 45 °C, SOC 0-100 % (DOD 100 %), 4 A | Inst3-01 | 21 | 21 | 2.734 | 1.061 | 38.8 % |
| LCT 1_05: 45 °C, SOC 0-100 % (DOD 100 %), 4 A | Inst3-02 | 16 | 16 | 2.745 | 1.100 | 40.1 % |
| LCT 1_06: 45 °C, SOC 0-100 % (DOD 100 %), 4 A | Inst4-03 | 10 | 10 | 2.703 | 2.202 | 81.5 % |
| LCT 1_06: 45 °C, SOC 0-100 % (DOD 100 %), 4 A | Inst4-04 | 10 | 10 | 2.701 | 2.158 | 79.9 % |
| LCT 1_10: 35 °C, SOC 0-100 % (DOD 100 %), 4 A | Inst1-09 | 26 | 26 | 2.696 | 2.160 | 80.1 % |
| LCT 1_10: 35 °C, SOC 0-100 % (DOD 100 %), 4 A | Inst1-10 | 66 | 66 | 2.692 | 0.608 | 22.6 % |
| LCT 1_10: 35 °C, SOC 0-100 % (DOD 100 %), 4 A | Inst1-11 | 66 | 66 | 2.698 | 0.467 | 17.3 % |
| LCT 1_11: 45 °C, SOC 25-75 % (DOD 50 %), 4 A | Inst1-13 | 48 | 46 | 2.666 | 2.208 | 82.8 % |
| LCT 1_11: 45 °C, SOC 25-75 % (DOD 50 %), 4 A | Inst1-14 | 48 | 46 | 2.671 | 2.212 | 82.8 % |
| LCT 1_11: 45 °C, SOC 25-75 % (DOD 50 %), 4 A | Inst1-17 | 34 | 33 | 2.750 | 2.368 | 86.1 % |
| LCT 1_11: 45 °C, SOC 25-75 % (DOD 50 %), 4 A | Inst1-19 | 34 | 33 | 2.723 | 2.372 | 87.1 % |
| LCT 1_13: 23 °C, SOC 0-100 % (DOD 100 %), 4 A | Inst3-03 | 17 | 17 | 2.735 | 0.857 | 31.3 % |
| LCT 1_13: 23 °C, SOC 0-100 % (DOD 100 %), 4 A | Inst3-04 | 16 | 16 | 2.731 | 0.855 | 31.3 % |
| LCT 1_13: 23 °C, SOC 0-100 % (DOD 100 %), 4 A | Inst3-07 | 16 | 16 | 2.736 | 1.057 | 38.6 % |
| LCT 1_13: 23 °C, SOC 0-100 % (DOD 100 %), 4 A | Inst3-08 | 16 | 16 | 2.711 | 1.091 | 40.2 % |
| LCT 1_14: 45 °C, SOC 50-100 % (DOD 50 %), 4 A | Inst6-13 | 29 | 29 | 2.498 | 2.119 | 84.8 % |
| LCT 1_14: 45 °C, SOC 50-100 % (DOD 50 %), 4 A | Inst6-14 | 28 | 28 | 2.514 | 2.103 | 83.7 % |
| LCT 1_15: 45 °C, SOC 30-100 % (DOD 70 %), 4 A | Inst2-10 | 34 | 34 | 2.751 | 1.825 | 66.3 % |
| LCT 1_15: 45 °C, SOC 30-100 % (DOD 70 %), 4 A | Inst2-12 | 34 | 34 | 2.751 | 2.171 | 78.9 % |
| LCT 1_16: 45 °C, SOC 70-100 % (DOD 30 %), 4 A | Inst2-11 | 34 | 34 | 2.765 | 2.361 | 85.4 % |
| LCT 1_16: 45 °C, SOC 70-100 % (DOD 30 %), 4 A | Inst2-13 | 34 | 34 | 2.763 | 2.368 | 85.7 % |
| LCT 1_17: 5 °C, SOC 0-100 % (DOD 100 %), 4 A | Inst4-07 | 5 | 5 | 2.664 | 1.962 | 73.6 % |
| LCT 1_17: 5 °C, SOC 0-100 % (DOD 100 %), 4 A | Inst4-08 | 5 | 5 | 2.665 | 2.124 | 79.7 % |
Test programmes
- LCT 1_01: 45 °C, SOC 0-100 % (DOD 100 %), 4 A. 4 cell(s): Inst5-15, Inst5-16, Inst5-17, Inst5-18; Institution 5; cycling at 45 °C between 0 and 100 % SOC at 4 A (CC-CV charge, CV until 300 mA; CC discharge); EIS at 23 °C (metadata table, row LCT_ID 1_01). Drawn: 1.25 A capacity checks at 23 °C, against the cycles run before each.
- LCT 1_02: 45 °C, SOC 0-100 % (DOD 100 %), 4 A. 3 cell(s): Inst1-04, Inst1-05, Inst1-06; Institution 1; cycling at 45 °C between 0 and 100 % SOC at 4 A (CC-CV charge, CV until 300 mA; CC discharge); EIS at 23 °C (metadata table, row LCT_ID 1_02). Drawn: 1.25 A capacity checks at 23 °C, against the cycles run before each.
- LCT 1_03: 45 °C, SOC 0-100 % (DOD 100 %), 4 A. 2 cell(s): Inst6-11, Inst6-12; Institution 6; cycling at 45 °C between 0 and 100 % SOC at 4 A (CC-CV charge, CV until 300 mA; CC discharge); EIS at 23 °C (metadata table, row LCT_ID 1_03). Drawn: 1.25 A capacity checks at 23 °C, against the cycles run before each.
- LCT 1_04: 45 °C, SOC 0-100 % (DOD 100 %), 4 A. 2 cell(s): Inst2-06, Inst2-07; Institution 2; cycling at 45 °C between 0 and 100 % SOC at 4 A (CC-CV charge, CV until 300 mA; CC discharge); EIS at 23 °C (metadata table, row LCT_ID 1_04). Drawn: 1.25 A capacity checks at 23 °C, against the cycles run before each.
- LCT 1_05: 45 °C, SOC 0-100 % (DOD 100 %), 4 A. 2 cell(s): Inst3-01, Inst3-02; Institution 3; cycling at 45 °C between 0 and 100 % SOC at 4 A (CC-CV charge, CV until 300 mA; CC discharge); EIS at 23 °C (metadata table, row LCT_ID 1_05). Drawn: 1.25 A capacity checks at 23 °C, against the cycles run before each.
- LCT 1_06: 45 °C, SOC 0-100 % (DOD 100 %), 4 A. 2 cell(s): Inst4-03, Inst4-04; Institution 4; cycling at 45 °C between 0 and 100 % SOC at 4 A (CC-CV charge, CV until 300 mA; CC discharge); EIS at 23 °C (metadata table, row LCT_ID 1_06). Drawn: 1.25 A capacity checks at 23 °C, against the cycles run before each.
- LCT 1_10: 35 °C, SOC 0-100 % (DOD 100 %), 4 A. 3 cell(s): Inst1-09, Inst1-10, Inst1-11; Institution 1; cycling at 35 °C between 0 and 100 % SOC at 4 A (CC-CV charge, CV until 300 mA; CC discharge); EIS at 23 °C (metadata table, row LCT_ID 1_10). Drawn: 1.25 A capacity checks at 23 °C, against the cycles run before each.
- LCT 1_11: 45 °C, SOC 25-75 % (DOD 50 %), 4 A. 4 cell(s): Inst1-13, Inst1-14, Inst1-17, Inst1-19; Institution 1; cycling at 45 °C between 25 and 75 % SOC at 4 A (CC-CV charge, CV until 300 mA; CC discharge); EIS at 23 °C (metadata table, row LCT_ID 1_11). Drawn: 1.25 A capacity checks at 23 °C, against the cycles run before each.
- LCT 1_13: 23 °C, SOC 0-100 % (DOD 100 %), 4 A. 4 cell(s): Inst3-03, Inst3-04, Inst3-07, Inst3-08; Institution 3; cycling at 23 °C between 0 and 100 % SOC at 4 A (CC-CV charge, CV until 300 mA; CC discharge); EIS at 23 °C (metadata table, row LCT_ID 1_13). Drawn: 1.25 A capacity checks at 23 °C, against the cycles run before each.
- LCT 1_14: 45 °C, SOC 50-100 % (DOD 50 %), 4 A. 2 cell(s): Inst6-13, Inst6-14; Institution 6; cycling at 45 °C between 50 and 100 % SOC at 4 A (CC-CV charge, CV until 300 mA; CC discharge); EIS at 23 °C (metadata table, row LCT_ID 1_14). Drawn: 1.25 A capacity checks at 23 °C, against the cycles run before each.
- LCT 1_15: 45 °C, SOC 30-100 % (DOD 70 %), 4 A. 2 cell(s): Inst2-10, Inst2-12; Institution 2; cycling at 45 °C between 30 and 100 % SOC at 4 A (CC-CV charge, CV until 300 mA; CC discharge); EIS at 23 °C (metadata table, row LCT_ID 1_15). Drawn: 1.25 A capacity checks at 23 °C, against the cycles run before each.
- LCT 1_16: 45 °C, SOC 70-100 % (DOD 30 %), 4 A. 2 cell(s): Inst2-11, Inst2-13; Institution 2; cycling at 45 °C between 70 and 100 % SOC at 4 A (CC-CV charge, CV until 300 mA; CC discharge); EIS at 23 °C (metadata table, row LCT_ID 1_16). Drawn: 1.25 A capacity checks at 23 °C, against the cycles run before each.
- LCT 1_17: 5 °C, SOC 0-100 % (DOD 100 %), 4 A. 2 cell(s): Inst4-07, Inst4-08; Institution 4; cycling at 5 °C between 0 and 100 % SOC at 4 A (CC-CV charge, CV until 300 mA; CC discharge); EIS at 23 °C (metadata table, row LCT_ID 1_17). Drawn: 1.25 A capacity checks at 23 °C, against the cycles run before each.
Columns of the CSV
LCT_Data.mat read with mat-io (its four MATLAB tables), then battery-data tools/convert_libforsecuse.py: a check-up is one (Cell_ID, nCycle) of the exps table; its capacity and SOH are the record's (the same in every SOC row of the check-up; checked); each EIS spectrum of data_EIS for that check-up gives the real part of the impedance where the imaginary part first changes sign from the high-frequency end. All cells share one source file; each source_files entry names its cell. Values rounded: Ah and SOH to 6 decimals, mOhm to 4.
| Column | Unit | Meaning |
|---|---|---|
batch | – | the life-cycle test (LCT_ID) and its cycling conditions from the record's metadata table: cycling temperature, SOC window (SOC_cycle_high minus DOD_cycle to SOC_cycle_high), cycling current |
cell | – | the record's Cell_ID (Inst<institution>-<number>) |
cycle | – | check-up number for this cell, 1-based, in order of n_cycle (not a cycle count) |
label | – | what the check-up holds |
n_cycle | – | the record's nCycle: 'Number of conventional charge-discharge cycles elapsed' before this check-up |
discharge_ah | Ah | the record's Qcap_mAh in Ah: 'Measured cell capacity', by 'full discharge from 4.2 V to 2.9 V at 23 °C and 1.25 A'; blank where the record gives -1 ('no capacity was measured at this condition') |
soh_reported | – | the record's SOH: 'ratio of measured cell capacity to measured value on fresh cell (nCycle = 0)'; blank where it gives -1 |
r_eis_im0_20soc_mohm | mOhm | from the check-up's EIS spectrum at 20 % SOC (23 °C, 0.5 A excitation): Re(Z) where Im(Z) first turns from positive (inductive) to negative scanning down from the highest frequency, interpolated linearly between the two frequencies around it; computed by Lemonergy; blank where no spectrum at that SOC or no sign change |
r_eis_im0_25soc_mohm | mOhm | from the check-up's EIS spectrum at 25 % SOC (23 °C, 0.5 A excitation): Re(Z) where Im(Z) first turns from positive (inductive) to negative scanning down from the highest frequency, interpolated linearly between the two frequencies around it; computed by Lemonergy; blank where no spectrum at that SOC or no sign change |
r_eis_im0_35soc_mohm | mOhm | from the check-up's EIS spectrum at 35 % SOC (23 °C, 0.5 A excitation): Re(Z) where Im(Z) first turns from positive (inductive) to negative scanning down from the highest frequency, interpolated linearly between the two frequencies around it; computed by Lemonergy; blank where no spectrum at that SOC or no sign change |
r_eis_im0_50soc_mohm | mOhm | from the check-up's EIS spectrum at 50 % SOC (23 °C, 0.5 A excitation): Re(Z) where Im(Z) first turns from positive (inductive) to negative scanning down from the highest frequency, interpolated linearly between the two frequencies around it; computed by Lemonergy; blank where no spectrum at that SOC or no sign change |
r_eis_im0_65soc_mohm | mOhm | from the check-up's EIS spectrum at 65 % SOC (23 °C, 0.5 A excitation): Re(Z) where Im(Z) first turns from positive (inductive) to negative scanning down from the highest frequency, interpolated linearly between the two frequencies around it; computed by Lemonergy; blank where no spectrum at that SOC or no sign change |
r_eis_im0_80soc_mohm | mOhm | from the check-up's EIS spectrum at 80 % SOC (23 °C, 0.5 A excitation): Re(Z) where Im(Z) first turns from positive (inductive) to negative scanning down from the highest frequency, interpolated linearly between the two frequencies around it; computed by Lemonergy; blank where no spectrum at that SOC or no sign change |
r_eis_im0_100soc_mohm | mOhm | from the check-up's EIS spectrum at 100 % SOC (23 °C, 0.5 A excitation): Re(Z) where Im(Z) first turns from positive (inductive) to negative scanning down from the highest frequency, interpolated linearly between the two frequencies around it; computed by Lemonergy; blank where no spectrum at that SOC or no sign change |
eis_socs | – | the states of charge (%) at which the record holds an EIS spectrum for this check-up, ';'-separated |
nfra_socs | – | the states of charge (%) at which the record holds an NFRA data set (Institution 2 only), ';'-separated; not imported |
Data quality
No per-cell quality verdict was recorded for this dataset. Read the caveats below before comparing cells.
Before comparing cells
- Maker and model are not stated in the record, the release PDF or the data file; the cells are filed under the library's placeholder maker as 'LiBforSecUse 18650' (3 Ah, NMC811/silicon-graphite, as the release says). The release says all 34 are 'from a single supplier and batch'; do not compare them with a named cell as if they were it.
- The release: 'Larger than expected inductive distortion of EIS recorded by Institution 5' and 'Altered cycling aging behaviour of cells used by Institution 6, attributed to increased calendaric aging (due to COVID-19 disruption) prior to experiments beginning'; 'only data from Institutions 1-4 were considered in the project'. Those cells (Inst5-*, Inst6-*) are kept, as the record keeps them 'for completeness'; their institution is in source_files.
- The EIS resistances are a reading of each spectrum (Re(Z) at Im(Z) = 0), computed by Lemonergy, not a value the record states. The Institution 5 spectra cross zero at about a third of the others' value, which is the inductive distortion the release names. Compare within one institution.
- Check-ups without a capacity (the record gives -1) are kept for their EIS, labelled as such: four Institution 5 cells at nCycle 0 (their first capacity is at nCycle 2, so their SOH is relative to that) and seven later check-ups of Institution 1 cells.
- n_cycle counts the 'conventional charge-discharge cycles elapsed'; at a DOD below 100 % a cycle moves less charge, so compare n_cycle only within one batch.
- Not imported: the EIS spectra themselves (the library has no impedance-spectrum curve kind, and these cells are not a library product a source revision could attach to) and the NFRA harmonics (Institution 2 only). Both stay in the record; eis_socs and nfra_socs say where they are.
- Each point is a check-up: the capacity the record gives (1.25 A from 4.2 V to 2.9 V at 23 °C), against the cycles run before it. The tests cycle over different depths (30 to 100 % of the charge), so compare cycle counts only within one test. The release names no maker and no model: the 34 cells are commercial 3 Ah cells from one supplier and batch. Eleven check-ups hold impedance spectra only and are not drawn. The impedance resistances in the CSV are Lemonergy's reading of each spectrum (the real part where the imaginary part crosses zero), not values the record states. The release says Institution 6's cells aged more on the shelf before testing, and that the project used only Institutions 1 to 4; every cell is drawn as recorded.
Licence and how to cite
The values are published under CC BY 4.0, as the source is. Credit it as follows.
Cite: Chan, H. S., Dickinson, E., Fedorovskaya, E., Gaberšček, M., Heins, T. P., Meddings, N., Lee, Y. Y., Moškon, J., Park, J., Ruiz, V., Seitz, S. LiBforSecUse Data Release - Impedance spectra of life cycle tests of commercial 18650 cells, V2. Zenodo (2022). doi:10.5281/zenodo.6418665
Credit: Data: Chan, Dickinson, Fedorovskaya, Gaberšček, Heins, Meddings, Lee, Moškon, Park, Ruiz, Seitz (KIT, NPL, Aalto University, National Institute of Chemistry, PTB, JRC), EMPIR project 17IND10 LiBforSecUse (co-funded by the European Union's Horizon 2020 programme and the EMPIR Participating States), doi:10.5281/zenodo.6418665, CC BY 4.0. Check-up values computed by Lemonergy (battery-data).
Values pinned to battery-data revision e85dd43. The manifest names every source file by its SHA-256; the CSV’s own SHA-256 is 09620e83af69da5e100a5e8a3292f86889050b48624d4601b624065e057d48b3.
Related
- XJTU battery ageing data: 55 Lishen 18650 cells, cycle by cycle
- CALCE CS2 battery ageing data: 15 LiCoO2 cells, cycle by cycle
- Tongji/KIT NCA ageing data: 66 18650 cells, cycle by cycle
- Tongji/KIT NCM ageing data: 55 18650 cells, cycle by cycle
- Tongji/KIT NCM+NCA ageing data: 9 18650 cells at three discharge rates
- Michigan VTC6 data: 194 characterisations of 70 aged 18650 cells
- CMU eVTOL battery data: 22 VTC6 cells under aircraft missions
- NASA PCoE battery ageing data: 34 18650 cells, cycle by cycle
- Oxford battery degradation data: 8 Kokam pouch cells, test by test
- UConn LFP ageing data: 64 18650 cells under 11 cycling conditions
- HYDRA ageing data: 32 LG MJ1 18650 cells under ship-like cycling
- REBELION ageing data: 160 Samsung 50E cells, four cycling strategies
- TEMPEST ageing data: a 280 Ah LFP cell over 700 cycles at 1C
- VERSAPRINT cycle data: one Lishen 51 Ah cell, nine cycles
- EVERLASTING ageing data: 28 Samsung 35E cells under drive cycles
- FreeTwinEV module data: four Molicel P45B cells in parallel, 14 runs
- All open battery ageing data on Lemonergy
- How these datasets were imported and checked
- Find and compare battery cells