lemonergy/ data Sign in

Open battery ageing data · LiBforSecUse 18650

LiBforSecUse ageing data: 34 18650 NMC811 cells, 13 life-cycle tests

The LiBforSecUse data release (Chan et al., for the EMPIR project LiBforSecUse, 17IND10, 2022) holds life-cycle tests of 34 commercial 18650 cells of 3 Ah, with an NMC811 cathode and a silicon-graphite anode. Six laboratories ran them: PTB, NPL, KIT, Aalto University, the National Institute of Chemistry (Slovenia) and JRC. All cells came from one supplier and batch; the release does not name the maker or the model. Thirteen tests cycled them at 5 to 45 °C over 30 to 100 % of their charge. At each check-up the record gives the capacity at 1.25 A and 23 °C, and impedance spectra at several states of charge. Lemonergy filed one row per check-up from the published file.

Free to download, no account needed. Or read it straight into Python:

import pandas as pd
cycles = pd.read_csv("https://lemonergy.com/data/ageing/libforsecuse-18650-2022/cycles.csv")
Cells
34 cells, 18650 (the release: 'cylindrical 18650 format'); maker not stated
Chemistry
NMC811 / silicon-graphite (the release: 'NMC811-silicon/graphite chemistry (NMC811 = LiNi0.8Co0.1Mn0.1O2)')
Nominal capacity
3 Ah
Check-ups
966, one row each
Test programmes
13
Published by
PTB, NPL, KIT, Aalto University, National Institute of Chemistry (Slovenia) and JRC, for the EMPIR project LiBforSecUse (17IND10)
Licence
CC BY 4.0
Files retrieved
2026-11-14

Source: LiBforSecUse Data Release: life-cycle tests of commercial 18650 cells (check-ups: capacity and EIS), PTB, NPL, KIT, Aalto University, National Institute of Chemistry (Slovenia) and JRC, for the EMPIR project LiBforSecUse (17IND10), doi:10.5281/zenodo.6418665. Licence: CC BY 4.0.

Cite: Chan, H. S., Dickinson, E., Fedorovskaya, E., Gaberšček, M., Heins, T. P., Meddings, N., Lee, Y. Y., Moškon, J., Park, J., Ruiz, V., Seitz, S. LiBforSecUse Data Release - Impedance spectra of life cycle tests of commercial 18650 cells, V2. Zenodo (2022). doi:10.5281/zenodo.6418665

Licence and how to cite · Data quality · Every source file, by SHA-256

Capacity fade, check-up by check-up

Capacity at each check-up (1.25 A at 23 °C), against the cycles run before it, one coloured line per cell, one test at a time. Point at a chart to read the values; download them as Excel.

The chart needs JavaScript; every cell’s values are in the table below and in the CSV.

Every cell

First and last discharge capacity of the check-ups the chart draws, for all 34 cells. Every row of every cell, with all its values, is in the CSV (223 kB).

ProgrammeCellCheck-upsPoints drawnFirst (Ah)Last (Ah)Last / first
LCT 1_01: 45 °C, SOC 0-100 % (DOD 100 %), 4 AInst5-1527262.6652.05477.1 %
LCT 1_01: 45 °C, SOC 0-100 % (DOD 100 %), 4 AInst5-1627262.7122.05575.8 %
LCT 1_01: 45 °C, SOC 0-100 % (DOD 100 %), 4 AInst5-1727262.6641.54458.0 %
LCT 1_01: 45 °C, SOC 0-100 % (DOD 100 %), 4 AInst5-1827262.7012.00974.4 %
LCT 1_02: 45 °C, SOC 0-100 % (DOD 100 %), 4 AInst1-0425252.6962.16080.1 %
LCT 1_02: 45 °C, SOC 0-100 % (DOD 100 %), 4 AInst1-0546462.6960.82430.6 %
LCT 1_02: 45 °C, SOC 0-100 % (DOD 100 %), 4 AInst1-0643422.6881.34750.1 %
LCT 1_03: 45 °C, SOC 0-100 % (DOD 100 %), 4 AInst6-1117172.5241.99479.0 %
LCT 1_03: 45 °C, SOC 0-100 % (DOD 100 %), 4 AInst6-1212122.5112.02780.7 %
LCT 1_04: 45 °C, SOC 0-100 % (DOD 100 %), 4 AInst2-0634342.7601.47653.5 %
LCT 1_04: 45 °C, SOC 0-100 % (DOD 100 %), 4 AInst2-0734342.7591.53655.7 %
LCT 1_05: 45 °C, SOC 0-100 % (DOD 100 %), 4 AInst3-0121212.7341.06138.8 %
LCT 1_05: 45 °C, SOC 0-100 % (DOD 100 %), 4 AInst3-0216162.7451.10040.1 %
LCT 1_06: 45 °C, SOC 0-100 % (DOD 100 %), 4 AInst4-0310102.7032.20281.5 %
LCT 1_06: 45 °C, SOC 0-100 % (DOD 100 %), 4 AInst4-0410102.7012.15879.9 %
LCT 1_10: 35 °C, SOC 0-100 % (DOD 100 %), 4 AInst1-0926262.6962.16080.1 %
LCT 1_10: 35 °C, SOC 0-100 % (DOD 100 %), 4 AInst1-1066662.6920.60822.6 %
LCT 1_10: 35 °C, SOC 0-100 % (DOD 100 %), 4 AInst1-1166662.6980.46717.3 %
LCT 1_11: 45 °C, SOC 25-75 % (DOD 50 %), 4 AInst1-1348462.6662.20882.8 %
LCT 1_11: 45 °C, SOC 25-75 % (DOD 50 %), 4 AInst1-1448462.6712.21282.8 %
LCT 1_11: 45 °C, SOC 25-75 % (DOD 50 %), 4 AInst1-1734332.7502.36886.1 %
LCT 1_11: 45 °C, SOC 25-75 % (DOD 50 %), 4 AInst1-1934332.7232.37287.1 %
LCT 1_13: 23 °C, SOC 0-100 % (DOD 100 %), 4 AInst3-0317172.7350.85731.3 %
LCT 1_13: 23 °C, SOC 0-100 % (DOD 100 %), 4 AInst3-0416162.7310.85531.3 %
LCT 1_13: 23 °C, SOC 0-100 % (DOD 100 %), 4 AInst3-0716162.7361.05738.6 %
LCT 1_13: 23 °C, SOC 0-100 % (DOD 100 %), 4 AInst3-0816162.7111.09140.2 %
LCT 1_14: 45 °C, SOC 50-100 % (DOD 50 %), 4 AInst6-1329292.4982.11984.8 %
LCT 1_14: 45 °C, SOC 50-100 % (DOD 50 %), 4 AInst6-1428282.5142.10383.7 %
LCT 1_15: 45 °C, SOC 30-100 % (DOD 70 %), 4 AInst2-1034342.7511.82566.3 %
LCT 1_15: 45 °C, SOC 30-100 % (DOD 70 %), 4 AInst2-1234342.7512.17178.9 %
LCT 1_16: 45 °C, SOC 70-100 % (DOD 30 %), 4 AInst2-1134342.7652.36185.4 %
LCT 1_16: 45 °C, SOC 70-100 % (DOD 30 %), 4 AInst2-1334342.7632.36885.7 %
LCT 1_17: 5 °C, SOC 0-100 % (DOD 100 %), 4 AInst4-07552.6641.96273.6 %
LCT 1_17: 5 °C, SOC 0-100 % (DOD 100 %), 4 AInst4-08552.6652.12479.7 %

Test programmes

Columns of the CSV

LCT_Data.mat read with mat-io (its four MATLAB tables), then battery-data tools/convert_libforsecuse.py: a check-up is one (Cell_ID, nCycle) of the exps table; its capacity and SOH are the record's (the same in every SOC row of the check-up; checked); each EIS spectrum of data_EIS for that check-up gives the real part of the impedance where the imaginary part first changes sign from the high-frequency end. All cells share one source file; each source_files entry names its cell. Values rounded: Ah and SOH to 6 decimals, mOhm to 4.

ColumnUnitMeaning
batch–the life-cycle test (LCT_ID) and its cycling conditions from the record's metadata table: cycling temperature, SOC window (SOC_cycle_high minus DOD_cycle to SOC_cycle_high), cycling current
cell–the record's Cell_ID (Inst<institution>-<number>)
cycle–check-up number for this cell, 1-based, in order of n_cycle (not a cycle count)
label–what the check-up holds
n_cycle–the record's nCycle: 'Number of conventional charge-discharge cycles elapsed' before this check-up
discharge_ahAhthe record's Qcap_mAh in Ah: 'Measured cell capacity', by 'full discharge from 4.2 V to 2.9 V at 23 °C and 1.25 A'; blank where the record gives -1 ('no capacity was measured at this condition')
soh_reported–the record's SOH: 'ratio of measured cell capacity to measured value on fresh cell (nCycle = 0)'; blank where it gives -1
r_eis_im0_20soc_mohmmOhmfrom the check-up's EIS spectrum at 20 % SOC (23 °C, 0.5 A excitation): Re(Z) where Im(Z) first turns from positive (inductive) to negative scanning down from the highest frequency, interpolated linearly between the two frequencies around it; computed by Lemonergy; blank where no spectrum at that SOC or no sign change
r_eis_im0_25soc_mohmmOhmfrom the check-up's EIS spectrum at 25 % SOC (23 °C, 0.5 A excitation): Re(Z) where Im(Z) first turns from positive (inductive) to negative scanning down from the highest frequency, interpolated linearly between the two frequencies around it; computed by Lemonergy; blank where no spectrum at that SOC or no sign change
r_eis_im0_35soc_mohmmOhmfrom the check-up's EIS spectrum at 35 % SOC (23 °C, 0.5 A excitation): Re(Z) where Im(Z) first turns from positive (inductive) to negative scanning down from the highest frequency, interpolated linearly between the two frequencies around it; computed by Lemonergy; blank where no spectrum at that SOC or no sign change
r_eis_im0_50soc_mohmmOhmfrom the check-up's EIS spectrum at 50 % SOC (23 °C, 0.5 A excitation): Re(Z) where Im(Z) first turns from positive (inductive) to negative scanning down from the highest frequency, interpolated linearly between the two frequencies around it; computed by Lemonergy; blank where no spectrum at that SOC or no sign change
r_eis_im0_65soc_mohmmOhmfrom the check-up's EIS spectrum at 65 % SOC (23 °C, 0.5 A excitation): Re(Z) where Im(Z) first turns from positive (inductive) to negative scanning down from the highest frequency, interpolated linearly between the two frequencies around it; computed by Lemonergy; blank where no spectrum at that SOC or no sign change
r_eis_im0_80soc_mohmmOhmfrom the check-up's EIS spectrum at 80 % SOC (23 °C, 0.5 A excitation): Re(Z) where Im(Z) first turns from positive (inductive) to negative scanning down from the highest frequency, interpolated linearly between the two frequencies around it; computed by Lemonergy; blank where no spectrum at that SOC or no sign change
r_eis_im0_100soc_mohmmOhmfrom the check-up's EIS spectrum at 100 % SOC (23 °C, 0.5 A excitation): Re(Z) where Im(Z) first turns from positive (inductive) to negative scanning down from the highest frequency, interpolated linearly between the two frequencies around it; computed by Lemonergy; blank where no spectrum at that SOC or no sign change
eis_socs–the states of charge (%) at which the record holds an EIS spectrum for this check-up, ';'-separated
nfra_socs–the states of charge (%) at which the record holds an NFRA data set (Institution 2 only), ';'-separated; not imported

Data quality

No per-cell quality verdict was recorded for this dataset. Read the caveats below before comparing cells.

Before comparing cells

Licence and how to cite

The values are published under CC BY 4.0, as the source is. Credit it as follows.

Cite: Chan, H. S., Dickinson, E., Fedorovskaya, E., Gaberšček, M., Heins, T. P., Meddings, N., Lee, Y. Y., Moškon, J., Park, J., Ruiz, V., Seitz, S. LiBforSecUse Data Release - Impedance spectra of life cycle tests of commercial 18650 cells, V2. Zenodo (2022). doi:10.5281/zenodo.6418665

Credit: Data: Chan, Dickinson, Fedorovskaya, Gaberšček, Heins, Meddings, Lee, Moškon, Park, Ruiz, Seitz (KIT, NPL, Aalto University, National Institute of Chemistry, PTB, JRC), EMPIR project 17IND10 LiBforSecUse (co-funded by the European Union's Horizon 2020 programme and the EMPIR Participating States), doi:10.5281/zenodo.6418665, CC BY 4.0. Check-up values computed by Lemonergy (battery-data).

Values pinned to battery-data revision e85dd43. The manifest names every source file by its SHA-256; the CSV’s own SHA-256 is 09620e83af69da5e100a5e8a3292f86889050b48624d4601b624065e057d48b3.