lemonergy/ data Sign in

Open battery ageing data · HYDRA MJ1

HYDRA ageing data: 32 LG MJ1 18650 cells under ship-like cycling

The HYDRA maritime battery test dataset (Thorbjørnsen et al., Corvus Energy and SINTEF, for the EU project HYDRA, 2024) cycled 32 LG INR18650-MJ1 cells of 3.5 Ah under 26 conditions modelled on ship batteries: depth of discharge from 20 to 80 %, upper voltage from 3.8 to 4.2 V, and their own charge rate and discharge power. About every 500 equivalent full cycles each cell had a check-up: a full slow discharge and ten 10 s current pulses. The record holds every cycler sample (49.5 GB); Lemonergy reduced it to one row per check-up. Several cells ran only days or weeks and have one or two check-ups.

Free to download, no account needed. Or read it straight into Python:

import pandas as pd
cycles = pd.read_csv("https://lemonergy.com/data/ageing/hydra-mj1-2024/cycles.csv")
Cells
32 cells, 18650; maker: LG (files name the cells '18650-LG-3500-MJ1-<serial>'); the library files the INR18650 MJ1 under LG Energy Solution
Chemistry
not stated
Nominal capacity
3.5 Ah
Check-ups
175, one row each
Test programmes
26
Published by
Corvus Energy and SINTEF, for the EU project HYDRA
Licence
CC BY 4.0
Files retrieved
2026-11-11

Source: Lithium Ion Battery Test Dataset for Maritime Transport INR18650-MJ1 (check-ups), Corvus Energy and SINTEF, for the EU project HYDRA, doi:10.5281/zenodo.13318553. Licence: CC BY 4.0.

Cite: Thorbjørnsen, K., Bakdi, A., Kandepu, R., Mousteau, O., Clark, S. Lithium Ion Battery Test Dataset for Maritime Transport INR18650-MJ1 (1.0.0). Zenodo (2024). doi:10.5281/zenodo.13318553

Licence and how to cite · Data quality · Every source file, by SHA-256

Capacity fade, check-up by check-up

Discharge capacity at each check-up, against the equivalent full cycles run before it, one coloured line per cell, or per cell and check-up discharge where it changes. Point at a chart to read the values; download them as Excel.

The chart needs JavaScript; every cell’s values are in the table below and in the CSV.

Every cell

First and last discharge capacity of the check-ups the chart draws, for all 34 lines and cells. Every row of every cell, with all its values, is in the CSV (45 kB).

ProgrammeCellCheck-upsPoints drawnFirst (Ah)Last (Ah)Last / first
DOD 0.20, 3.80 V, charge 0.25C, discharge 0.25PMJ1-028663.4363.27395.3 %
DOD 0.20, 3.80 V, charge 0.25C, discharge 1.00PMJ1-024883.4303.20093.3 %
DOD 0.20, 3.80 V, charge 0.76C, discharge 1.00PMJ1-02910103.4243.18393.0 %
DOD 0.20, 3.90 V, charge 0.50C, discharge 0.75PMJ1-130773.5013.26193.1 %
DOD 0.20, 4.00 V, charge 0.75C, discharge 0.50PMJ1-023993.4383.12090.7 %
DOD 0.20, 4.05 V, charge 0.25C, discharge 0.25PMJ1-136443.5123.33695.0 %
DOD 0.20, 4.10 V, charge 0.25C, discharge 1.00PMJ1-026773.4333.10590.4 %
DOD 0.20, 4.20 V, charge 0.50C, discharge 0.25PMJ1-025663.4433.17792.3 %
DOD 0.20, 4.20 V, charge 0.75C, discharge 1.00PMJ1-021773.4422.91084.5 %
DOD 0.40, 3.80 V, charge 0.50C, discharge 0.75PMJ1-01011113.3672.72681.0 %
DOD 0.40, 3.80 V, charge 0.50C, discharge 0.75PMJ1-011 at 0.7 A CC-CV913.3873.387100.0 %
DOD 0.40, 3.80 V, charge 0.50C, discharge 0.75PMJ1-011 at 0.7 A973.2503.10995.6 %
DOD 0.40, 3.80 V, charge 0.50C, discharge 0.75PMJ1-011 at 0.1 A913.1543.154100.0 %
DOD 0.40, 3.80 V, charge 0.50C, discharge 0.75PMJ1-02011113.4423.04788.5 %
DOD 0.40, 4.20 V, charge 0.25C, discharge 0.50PMJ1-030223.4333.38598.6 %
DOD 0.45, 3.90 V, charge 0.75C, discharge 0.25PMJ1-129663.5073.23492.2 %
DOD 0.45, 4.20 V, charge 0.75C, discharge 0.50PMJ1-133443.4992.87782.2 %
DOD 0.50, 3.80 V, charge 0.75C, discharge 0.50PMJ1-027113.4353.435100.0 %
DOD 0.50, 4.00 V, charge 0.50C, discharge 0.63PMJ1-126883.5013.11288.9 %
DOD 0.50, 4.00 V, charge 0.50C, discharge 0.63PMJ1-138883.5163.04386.6 %
DOD 0.50, 4.05 V, charge 0.50C, discharge 0.63PMJ1-127883.5162.97484.6 %
DOD 0.50, 4.10 V, charge 0.75C, discharge 1.00PMJ1-139883.5132.80279.8 %
DOD 0.60, 4.00 V, charge 0.30C, discharge 1.00PMJ1-134553.5153.12789.0 %
DOD 0.60, 4.20 V, charge 0.25C, discharge 0.25PMJ1-137553.5063.08588.0 %
DOD 0.60, 4.20 V, charge 0.50C, discharge 1.00PMJ1-132333.5042.90682.9 %
DOD 0.65, 4.00 V, charge 0.25C, discharge 0.50PMJ1-032333.4373.19192.8 %
DOD 0.65, 4.00 V, charge 0.25C, discharge 0.50PMJ1-087333.4753.19191.8 %
DOD 0.65, 4.00 V, charge 0.25C, discharge 0.50PMJ1-088333.4983.19591.3 %
DOD 0.70, 4.00 V, charge 0.25C, discharge 0.25PMJ1-022333.4423.14091.2 %
DOD 0.75, 4.05 V, charge 0.50C, discharge 0.75PMJ1-140223.5063.47499.1 %
DOD 0.80, 4.00 V, charge 0.75C, discharge 1.00PMJ1-135223.5193.50899.7 %
DOD 0.80, 4.20 V, charge 0.25C, discharge 1.00PMJ1-131333.5063.16490.3 %
DOD 0.80, 4.20 V, charge 0.75C, discharge 0.25PMJ1-012113.3433.343100.0 %
DOD 0.80, 4.20 V, charge 0.75C, discharge 0.25PMJ1-128223.5113.02586.1 %

Test programmes

Columns of the CSV

Each INR18650_MJ1_NN.parquet downloaded from the record, its md5 checked against the record and its SHA-256 taken, then reduced with battery-data tools/convert_hydra_mj1.py: one row per cycler step (a run of rows with the same Test ID and step change count; the count wraps at 255), read one column at a time, then one row per check-up. A check-up is found from the data: a constant-current discharge to 2.5 V of about 0.1 A lasting over 5 h or of about 0.7 A lasting over 3 h, or a step of type 20 ending at 2.5 V with its current tapering to 0.1 A (CC-CV); shallow cycles are constant-power discharges and never qualify. Its capacity and energy are the cycler's step values; the charge back, the step that removes about 2 Ah before the pulses and the ten 10 s pulses that follow, until cycling resumes, belong to it. The raw files were deleted after reduction; nothing of them is stored here. Values are rounded as printed: Ah to 5 decimals, Wh to 4, mOhm to 3.

ColumnUnitMeaning
batch–the cell's test conditions from the record's metadata.csv: depth of discharge (discharge energy over nominal energy), upper voltage limit of the shallow cycles, charge C-rate, constant-power discharge (power over nominal energy, P)
cell–the cell as metadata.csv names it, without the '18650-LG-3500-' prefix (MJ1-<serial>)
cycle–check-up number for this cell, 1-based (not a cycle count; see efc and shallow_cycles)
label–which check-up discharge: 0.1 A from 4.2 V to 2.5 V, 0.7 A to 2.5 V, or 0.7 A held at 2.5 V until 0.1 A (CC-CV)
daysdtime from the cell's first logged step to the start of this check-up's discharge
efc–equivalent full cycles before this check-up: charge discharged by every earlier step, over the nominal 3.5 Ah
shallow_cycles–constant-power discharges (cycler step type 8) since the previous check-up
discharge_ahAhcapacity of the check-up discharge to 2.5 V, the cycler's step capacity
charge_ahAhcapacity of the charge back to 4.2 V that follows (blank when the record ends first)
discharge_whWhenergy of the check-up discharge, the cycler's step energy
discharge_current_aAlargest discharge current of the check-up discharge (0.1 A or 0.7 A)
v_maxVhighest voltage during the check-up discharge
v_minVlowest voltage during the check-up discharge
dcir_soc_removed_ahAhcharge removed from full before the pulses (sets the pulse state of charge, about 2 Ah of 3.5 Ah)
pulse_currents_aAthe five pulse currents of this check-up, ';'-separated, smallest first (0.5-4 A, or 1.85-5.56 A in the older tests)
dcir_dis_p1_mohmmOhm10 s discharge pulse resistance at the 1. pulse current: (voltage at the pulse's end - voltage at the end of the rest before it) / current
dcir_dis_p2_mohmmOhm10 s discharge pulse resistance at the 2. pulse current: (voltage at the pulse's end - voltage at the end of the rest before it) / current
dcir_dis_p3_mohmmOhm10 s discharge pulse resistance at the 3. pulse current: (voltage at the pulse's end - voltage at the end of the rest before it) / current
dcir_dis_p4_mohmmOhm10 s discharge pulse resistance at the 4. pulse current: (voltage at the pulse's end - voltage at the end of the rest before it) / current
dcir_dis_p5_mohmmOhm10 s discharge pulse resistance at the 5. pulse current: (voltage at the pulse's end - voltage at the end of the rest before it) / current
dcir_cha_p1_mohmmOhm10 s charge pulse resistance at the 1. pulse current: (voltage at the pulse's end - voltage at the end of the rest before it) / current
dcir_cha_p2_mohmmOhm10 s charge pulse resistance at the 2. pulse current: (voltage at the pulse's end - voltage at the end of the rest before it) / current
dcir_cha_p3_mohmmOhm10 s charge pulse resistance at the 3. pulse current: (voltage at the pulse's end - voltage at the end of the rest before it) / current
dcir_cha_p4_mohmmOhm10 s charge pulse resistance at the 4. pulse current: (voltage at the pulse's end - voltage at the end of the rest before it) / current
dcir_cha_p5_mohmmOhm10 s charge pulse resistance at the 5. pulse current: (voltage at the pulse's end - voltage at the end of the rest before it) / current

Data quality

No per-cell quality verdict was recorded for this dataset. Read the caveats below before comparing cells.

Before comparing cells

Licence and how to cite

The values are published under CC BY 4.0, as the source is. Credit it as follows.

Cite: Thorbjørnsen, K., Bakdi, A., Kandepu, R., Mousteau, O., Clark, S. Lithium Ion Battery Test Dataset for Maritime Transport INR18650-MJ1 (1.0.0). Zenodo (2024). doi:10.5281/zenodo.13318553

Credit: Data: Thorbjørnsen, K., Bakdi, A., Kandepu, R., Mousteau, O., Clark, S. (Corvus Energy, SINTEF), EU project HYDRA (Horizon 2020 grant 875527), doi:10.5281/zenodo.13318553, CC BY 4.0. Check-up values computed by Lemonergy (battery-data).

Values pinned to battery-data revision e85dd43. The manifest names every source file by its SHA-256; the CSV’s own SHA-256 is d55922c0783083640d35f9d5504db89b340def66bb771024d50e58903e221d1b.