Open battery ageing data · HYDRA MJ1
HYDRA ageing data: 32 LG MJ1 18650 cells under ship-like cycling
The HYDRA maritime battery test dataset (Thorbjørnsen et al., Corvus Energy and SINTEF, for the EU project HYDRA, 2024) cycled 32 LG INR18650-MJ1 cells of 3.5 Ah under 26 conditions modelled on ship batteries: depth of discharge from 20 to 80 %, upper voltage from 3.8 to 4.2 V, and their own charge rate and discharge power. About every 500 equivalent full cycles each cell had a check-up: a full slow discharge and ten 10 s current pulses. The record holds every cycler sample (49.5 GB); Lemonergy reduced it to one row per check-up. Several cells ran only days or weeks and have one or two check-ups.
Download every check-up (CSV, 45 kB)Manifest (JSON): files, hashes, unitsChart and Excel downloadOriginal dataset
Free to download, no account needed. Or read it straight into Python:
import pandas as pd
cycles = pd.read_csv("https://lemonergy.com/data/ageing/hydra-mj1-2024/cycles.csv")- Cells
- 32 cells, 18650; maker: LG (files name the cells '18650-LG-3500-MJ1-<serial>'); the library files the INR18650 MJ1 under LG Energy Solution
- Chemistry
- not stated
- Nominal capacity
- 3.5 Ah
- Check-ups
- 175, one row each
- Test programmes
- 26
- Published by
- Corvus Energy and SINTEF, for the EU project HYDRA
- Licence
- CC BY 4.0
- Files retrieved
- 2026-11-11
Source: Lithium Ion Battery Test Dataset for Maritime Transport INR18650-MJ1 (check-ups), Corvus Energy and SINTEF, for the EU project HYDRA, doi:10.5281/zenodo.13318553. Licence: CC BY 4.0.
Cite: Thorbjørnsen, K., Bakdi, A., Kandepu, R., Mousteau, O., Clark, S. Lithium Ion Battery Test Dataset for Maritime Transport INR18650-MJ1 (1.0.0). Zenodo (2024). doi:10.5281/zenodo.13318553
Licence and how to cite · Data quality · Every source file, by SHA-256
Capacity fade, check-up by check-up
Discharge capacity at each check-up, against the equivalent full cycles run before it, one coloured line per cell, or per cell and check-up discharge where it changes. Point at a chart to read the values; download them as Excel.
The chart needs JavaScript; every cell’s values are in the table below and in the CSV.
Point at or touch a chart to read every cell’s value at that cycle. Drag across it with a mouse to zoom in. Click a line, or a cell’s name in the legend or table, to show that cell on its own; the others turn grey.Touch a chart to read the values at a cycle. Tap a cell’s name in the legend or the table to show it on its own; the others turn grey.
| Cell | Check-ups | Points drawn | First (Ah) | Last (Ah) | Last / first |
|---|
Every cell
First and last discharge capacity of the check-ups the chart draws, for all 34 lines and cells. Every row of every cell, with all its values, is in the CSV (45 kB).
| Programme | Cell | Check-ups | Points drawn | First (Ah) | Last (Ah) | Last / first |
|---|---|---|---|---|---|---|
| DOD 0.20, 3.80 V, charge 0.25C, discharge 0.25P | MJ1-028 | 6 | 6 | 3.436 | 3.273 | 95.3 % |
| DOD 0.20, 3.80 V, charge 0.25C, discharge 1.00P | MJ1-024 | 8 | 8 | 3.430 | 3.200 | 93.3 % |
| DOD 0.20, 3.80 V, charge 0.76C, discharge 1.00P | MJ1-029 | 10 | 10 | 3.424 | 3.183 | 93.0 % |
| DOD 0.20, 3.90 V, charge 0.50C, discharge 0.75P | MJ1-130 | 7 | 7 | 3.501 | 3.261 | 93.1 % |
| DOD 0.20, 4.00 V, charge 0.75C, discharge 0.50P | MJ1-023 | 9 | 9 | 3.438 | 3.120 | 90.7 % |
| DOD 0.20, 4.05 V, charge 0.25C, discharge 0.25P | MJ1-136 | 4 | 4 | 3.512 | 3.336 | 95.0 % |
| DOD 0.20, 4.10 V, charge 0.25C, discharge 1.00P | MJ1-026 | 7 | 7 | 3.433 | 3.105 | 90.4 % |
| DOD 0.20, 4.20 V, charge 0.50C, discharge 0.25P | MJ1-025 | 6 | 6 | 3.443 | 3.177 | 92.3 % |
| DOD 0.20, 4.20 V, charge 0.75C, discharge 1.00P | MJ1-021 | 7 | 7 | 3.442 | 2.910 | 84.5 % |
| DOD 0.40, 3.80 V, charge 0.50C, discharge 0.75P | MJ1-010 | 11 | 11 | 3.367 | 2.726 | 81.0 % |
| DOD 0.40, 3.80 V, charge 0.50C, discharge 0.75P | MJ1-011 at 0.7 A CC-CV | 9 | 1 | 3.387 | 3.387 | 100.0 % |
| DOD 0.40, 3.80 V, charge 0.50C, discharge 0.75P | MJ1-011 at 0.7 A | 9 | 7 | 3.250 | 3.109 | 95.6 % |
| DOD 0.40, 3.80 V, charge 0.50C, discharge 0.75P | MJ1-011 at 0.1 A | 9 | 1 | 3.154 | 3.154 | 100.0 % |
| DOD 0.40, 3.80 V, charge 0.50C, discharge 0.75P | MJ1-020 | 11 | 11 | 3.442 | 3.047 | 88.5 % |
| DOD 0.40, 4.20 V, charge 0.25C, discharge 0.50P | MJ1-030 | 2 | 2 | 3.433 | 3.385 | 98.6 % |
| DOD 0.45, 3.90 V, charge 0.75C, discharge 0.25P | MJ1-129 | 6 | 6 | 3.507 | 3.234 | 92.2 % |
| DOD 0.45, 4.20 V, charge 0.75C, discharge 0.50P | MJ1-133 | 4 | 4 | 3.499 | 2.877 | 82.2 % |
| DOD 0.50, 3.80 V, charge 0.75C, discharge 0.50P | MJ1-027 | 1 | 1 | 3.435 | 3.435 | 100.0 % |
| DOD 0.50, 4.00 V, charge 0.50C, discharge 0.63P | MJ1-126 | 8 | 8 | 3.501 | 3.112 | 88.9 % |
| DOD 0.50, 4.00 V, charge 0.50C, discharge 0.63P | MJ1-138 | 8 | 8 | 3.516 | 3.043 | 86.6 % |
| DOD 0.50, 4.05 V, charge 0.50C, discharge 0.63P | MJ1-127 | 8 | 8 | 3.516 | 2.974 | 84.6 % |
| DOD 0.50, 4.10 V, charge 0.75C, discharge 1.00P | MJ1-139 | 8 | 8 | 3.513 | 2.802 | 79.8 % |
| DOD 0.60, 4.00 V, charge 0.30C, discharge 1.00P | MJ1-134 | 5 | 5 | 3.515 | 3.127 | 89.0 % |
| DOD 0.60, 4.20 V, charge 0.25C, discharge 0.25P | MJ1-137 | 5 | 5 | 3.506 | 3.085 | 88.0 % |
| DOD 0.60, 4.20 V, charge 0.50C, discharge 1.00P | MJ1-132 | 3 | 3 | 3.504 | 2.906 | 82.9 % |
| DOD 0.65, 4.00 V, charge 0.25C, discharge 0.50P | MJ1-032 | 3 | 3 | 3.437 | 3.191 | 92.8 % |
| DOD 0.65, 4.00 V, charge 0.25C, discharge 0.50P | MJ1-087 | 3 | 3 | 3.475 | 3.191 | 91.8 % |
| DOD 0.65, 4.00 V, charge 0.25C, discharge 0.50P | MJ1-088 | 3 | 3 | 3.498 | 3.195 | 91.3 % |
| DOD 0.70, 4.00 V, charge 0.25C, discharge 0.25P | MJ1-022 | 3 | 3 | 3.442 | 3.140 | 91.2 % |
| DOD 0.75, 4.05 V, charge 0.50C, discharge 0.75P | MJ1-140 | 2 | 2 | 3.506 | 3.474 | 99.1 % |
| DOD 0.80, 4.00 V, charge 0.75C, discharge 1.00P | MJ1-135 | 2 | 2 | 3.519 | 3.508 | 99.7 % |
| DOD 0.80, 4.20 V, charge 0.25C, discharge 1.00P | MJ1-131 | 3 | 3 | 3.506 | 3.164 | 90.3 % |
| DOD 0.80, 4.20 V, charge 0.75C, discharge 0.25P | MJ1-012 | 1 | 1 | 3.343 | 3.343 | 100.0 % |
| DOD 0.80, 4.20 V, charge 0.75C, discharge 0.25P | MJ1-128 | 2 | 2 | 3.511 | 3.025 | 86.1 % |
Test programmes
- DOD 0.20, 3.80 V, charge 0.25C, discharge 0.25P. 1 cell(s): MJ1-028; depth of discharge 0.2, upper voltage 3.8 V, charge 0.25C, discharge 0.25 P, check-up spacing 500 EFC. Drawn: check-up discharge capacity, against equivalent full cycles.
- DOD 0.20, 3.80 V, charge 0.25C, discharge 1.00P. 1 cell(s): MJ1-024; depth of discharge 0.2, upper voltage 3.8 V, charge 0.25C, discharge 1.0 P, check-up spacing 500 EFC. Drawn: check-up discharge capacity, against equivalent full cycles.
- DOD 0.20, 3.80 V, charge 0.76C, discharge 1.00P. 1 cell(s): MJ1-029; depth of discharge 0.2, upper voltage 3.8 V, charge 0.76C, discharge 1.0 P, check-up spacing 500 EFC. Drawn: check-up discharge capacity, against equivalent full cycles.
- DOD 0.20, 3.90 V, charge 0.50C, discharge 0.75P. 1 cell(s): MJ1-130; depth of discharge 0.2, upper voltage 3.9 V, charge 0.5C, discharge 0.75 P, check-up spacing 500 EFC. Drawn: check-up discharge capacity, against equivalent full cycles.
- DOD 0.20, 4.00 V, charge 0.75C, discharge 0.50P. 1 cell(s): MJ1-023; depth of discharge 0.2, upper voltage 4.0 V, charge 0.75C, discharge 0.5 P, check-up spacing 500 EFC. Drawn: check-up discharge capacity, against equivalent full cycles.
- DOD 0.20, 4.05 V, charge 0.25C, discharge 0.25P. 1 cell(s): MJ1-136; depth of discharge 0.2, upper voltage 4.05 V, charge 0.25C, discharge 0.25 P, check-up spacing 500 EFC. Drawn: check-up discharge capacity, against equivalent full cycles.
- DOD 0.20, 4.10 V, charge 0.25C, discharge 1.00P. 1 cell(s): MJ1-026; depth of discharge 0.2, upper voltage 4.1 V, charge 0.25C, discharge 1.0 P, check-up spacing 500 EFC. Drawn: check-up discharge capacity, against equivalent full cycles.
- DOD 0.20, 4.20 V, charge 0.50C, discharge 0.25P. 1 cell(s): MJ1-025; depth of discharge 0.2, upper voltage 4.2 V, charge 0.5C, discharge 0.25 P, check-up spacing 500 EFC. Drawn: check-up discharge capacity, against equivalent full cycles.
- DOD 0.20, 4.20 V, charge 0.75C, discharge 1.00P. 1 cell(s): MJ1-021; depth of discharge 0.2, upper voltage 4.2 V, charge 0.75C, discharge 1.0 P, check-up spacing 500 EFC. Drawn: check-up discharge capacity, against equivalent full cycles.
- DOD 0.40, 3.80 V, charge 0.50C, discharge 0.75P. 3 cell(s): MJ1-010, MJ1-011, MJ1-020; depth of discharge 0.4, upper voltage 3.8 V, charge 0.5C, discharge 0.75 P, check-up spacing 500 EFC. Drawn: check-up discharge capacity, against equivalent full cycles.
- DOD 0.40, 4.20 V, charge 0.25C, discharge 0.50P. 1 cell(s): MJ1-030; depth of discharge 0.4, upper voltage 4.2 V, charge 0.25C, discharge 0.5 P, check-up spacing 500 EFC. Drawn: check-up discharge capacity, against equivalent full cycles.
- DOD 0.45, 3.90 V, charge 0.75C, discharge 0.25P. 1 cell(s): MJ1-129; depth of discharge 0.45, upper voltage 3.9 V, charge 0.75C, discharge 0.25 P, check-up spacing 500 EFC. Drawn: check-up discharge capacity, against equivalent full cycles.
- DOD 0.45, 4.20 V, charge 0.75C, discharge 0.50P. 1 cell(s): MJ1-133; depth of discharge 0.45, upper voltage 4.2 V, charge 0.75C, discharge 0.5 P, check-up spacing 500 EFC. Drawn: check-up discharge capacity, against equivalent full cycles.
- DOD 0.50, 3.80 V, charge 0.75C, discharge 0.50P. 1 cell(s): MJ1-027; depth of discharge 0.5, upper voltage 3.8 V, charge 0.75C, discharge 0.5 P, check-up spacing 500 EFC. Drawn: check-up discharge capacity, against equivalent full cycles.
- DOD 0.50, 4.00 V, charge 0.50C, discharge 0.63P. 2 cell(s): MJ1-126, MJ1-138; depth of discharge 0.5, upper voltage 4.0 V, charge 0.5C, discharge 0.63 P, check-up spacing 500 EFC. Drawn: check-up discharge capacity, against equivalent full cycles.
- DOD 0.50, 4.05 V, charge 0.50C, discharge 0.63P. 1 cell(s): MJ1-127; depth of discharge 0.5, upper voltage 4.05 V, charge 0.5C, discharge 0.63 P, check-up spacing 500 EFC. Drawn: check-up discharge capacity, against equivalent full cycles.
- DOD 0.50, 4.10 V, charge 0.75C, discharge 1.00P. 1 cell(s): MJ1-139; depth of discharge 0.5, upper voltage 4.1 V, charge 0.75C, discharge 1.0 P, check-up spacing 500 EFC. Drawn: check-up discharge capacity, against equivalent full cycles.
- DOD 0.60, 4.00 V, charge 0.30C, discharge 1.00P. 1 cell(s): MJ1-134; depth of discharge 0.6, upper voltage 4.0 V, charge 0.3C, discharge 1.0 P, check-up spacing 500 EFC. Drawn: check-up discharge capacity, against equivalent full cycles.
- DOD 0.60, 4.20 V, charge 0.25C, discharge 0.25P. 1 cell(s): MJ1-137; depth of discharge 0.6, upper voltage 4.2 V, charge 0.25C, discharge 0.25 P, check-up spacing 500 EFC. Drawn: check-up discharge capacity, against equivalent full cycles.
- DOD 0.60, 4.20 V, charge 0.50C, discharge 1.00P. 1 cell(s): MJ1-132; depth of discharge 0.6, upper voltage 4.2 V, charge 0.5C, discharge 1.0 P, check-up spacing 500 EFC. Drawn: check-up discharge capacity, against equivalent full cycles.
- DOD 0.65, 4.00 V, charge 0.25C, discharge 0.50P. 3 cell(s): MJ1-032, MJ1-087, MJ1-088; depth of discharge 0.65, upper voltage 4.0 V, charge 0.25C, discharge 0.5 P, check-up spacing 500 EFC. Drawn: check-up discharge capacity, against equivalent full cycles.
- DOD 0.70, 4.00 V, charge 0.25C, discharge 0.25P. 1 cell(s): MJ1-022; depth of discharge 0.7, upper voltage 4.0 V, charge 0.25C, discharge 0.25 P, check-up spacing 500 EFC. Drawn: check-up discharge capacity, against equivalent full cycles.
- DOD 0.75, 4.05 V, charge 0.50C, discharge 0.75P. 1 cell(s): MJ1-140; depth of discharge 0.75, upper voltage 4.05 V, charge 0.5C, discharge 0.75 P, check-up spacing 500 EFC. Drawn: check-up discharge capacity, against equivalent full cycles.
- DOD 0.80, 4.00 V, charge 0.75C, discharge 1.00P. 1 cell(s): MJ1-135; depth of discharge 0.8, upper voltage 4.0 V, charge 0.75C, discharge 1.0 P, check-up spacing 500 EFC. Drawn: check-up discharge capacity, against equivalent full cycles.
- DOD 0.80, 4.20 V, charge 0.25C, discharge 1.00P. 1 cell(s): MJ1-131; depth of discharge 0.8, upper voltage 4.2 V, charge 0.25C, discharge 1.0 P, check-up spacing 500 EFC. Drawn: check-up discharge capacity, against equivalent full cycles.
- DOD 0.80, 4.20 V, charge 0.75C, discharge 0.25P. 2 cell(s): MJ1-012, MJ1-128; depth of discharge 0.8, upper voltage 4.2 V, charge 0.75C, discharge 0.25 P, check-up spacing 500 EFC. Drawn: check-up discharge capacity, against equivalent full cycles.
Columns of the CSV
Each INR18650_MJ1_NN.parquet downloaded from the record, its md5 checked against the record and its SHA-256 taken, then reduced with battery-data tools/convert_hydra_mj1.py: one row per cycler step (a run of rows with the same Test ID and step change count; the count wraps at 255), read one column at a time, then one row per check-up. A check-up is found from the data: a constant-current discharge to 2.5 V of about 0.1 A lasting over 5 h or of about 0.7 A lasting over 3 h, or a step of type 20 ending at 2.5 V with its current tapering to 0.1 A (CC-CV); shallow cycles are constant-power discharges and never qualify. Its capacity and energy are the cycler's step values; the charge back, the step that removes about 2 Ah before the pulses and the ten 10 s pulses that follow, until cycling resumes, belong to it. The raw files were deleted after reduction; nothing of them is stored here. Values are rounded as printed: Ah to 5 decimals, Wh to 4, mOhm to 3.
| Column | Unit | Meaning |
|---|---|---|
batch | – | the cell's test conditions from the record's metadata.csv: depth of discharge (discharge energy over nominal energy), upper voltage limit of the shallow cycles, charge C-rate, constant-power discharge (power over nominal energy, P) |
cell | – | the cell as metadata.csv names it, without the '18650-LG-3500-' prefix (MJ1-<serial>) |
cycle | – | check-up number for this cell, 1-based (not a cycle count; see efc and shallow_cycles) |
label | – | which check-up discharge: 0.1 A from 4.2 V to 2.5 V, 0.7 A to 2.5 V, or 0.7 A held at 2.5 V until 0.1 A (CC-CV) |
days | d | time from the cell's first logged step to the start of this check-up's discharge |
efc | – | equivalent full cycles before this check-up: charge discharged by every earlier step, over the nominal 3.5 Ah |
shallow_cycles | – | constant-power discharges (cycler step type 8) since the previous check-up |
discharge_ah | Ah | capacity of the check-up discharge to 2.5 V, the cycler's step capacity |
charge_ah | Ah | capacity of the charge back to 4.2 V that follows (blank when the record ends first) |
discharge_wh | Wh | energy of the check-up discharge, the cycler's step energy |
discharge_current_a | A | largest discharge current of the check-up discharge (0.1 A or 0.7 A) |
v_max | V | highest voltage during the check-up discharge |
v_min | V | lowest voltage during the check-up discharge |
dcir_soc_removed_ah | Ah | charge removed from full before the pulses (sets the pulse state of charge, about 2 Ah of 3.5 Ah) |
pulse_currents_a | A | the five pulse currents of this check-up, ';'-separated, smallest first (0.5-4 A, or 1.85-5.56 A in the older tests) |
dcir_dis_p1_mohm | mOhm | 10 s discharge pulse resistance at the 1. pulse current: (voltage at the pulse's end - voltage at the end of the rest before it) / current |
dcir_dis_p2_mohm | mOhm | 10 s discharge pulse resistance at the 2. pulse current: (voltage at the pulse's end - voltage at the end of the rest before it) / current |
dcir_dis_p3_mohm | mOhm | 10 s discharge pulse resistance at the 3. pulse current: (voltage at the pulse's end - voltage at the end of the rest before it) / current |
dcir_dis_p4_mohm | mOhm | 10 s discharge pulse resistance at the 4. pulse current: (voltage at the pulse's end - voltage at the end of the rest before it) / current |
dcir_dis_p5_mohm | mOhm | 10 s discharge pulse resistance at the 5. pulse current: (voltage at the pulse's end - voltage at the end of the rest before it) / current |
dcir_cha_p1_mohm | mOhm | 10 s charge pulse resistance at the 1. pulse current: (voltage at the pulse's end - voltage at the end of the rest before it) / current |
dcir_cha_p2_mohm | mOhm | 10 s charge pulse resistance at the 2. pulse current: (voltage at the pulse's end - voltage at the end of the rest before it) / current |
dcir_cha_p3_mohm | mOhm | 10 s charge pulse resistance at the 3. pulse current: (voltage at the pulse's end - voltage at the end of the rest before it) / current |
dcir_cha_p4_mohm | mOhm | 10 s charge pulse resistance at the 4. pulse current: (voltage at the pulse's end - voltage at the end of the rest before it) / current |
dcir_cha_p5_mohm | mOhm | 10 s charge pulse resistance at the 5. pulse current: (voltage at the pulse's end - voltage at the end of the rest before it) / current |
Data quality
No per-cell quality verdict was recorded for this dataset. Read the caveats below before comparing cells.
Before comparing cells
- Three check-up discharges are in the data: 0.1 A (about C/35; most cells), 0.7 A constant current, and 0.7 A held at 2.5 V until 0.1 A (CC-CV; in some of the older tests). Pulse currents are 0.5, 1, 2, 3 and 4 A for cells MJ1-126 to MJ1-140 (tests from December 2021) and 1.85-5.56 A for the older tests. The label and pulse_currents_a columns say which. Compare capacities only within one label.
- The record's metadata.csv step-range columns (soh_step_id, dcir_step_id, cyc_step_id) were turned into dates by a spreadsheet ('03-Jun' for 3-6, 'Aug-28' for 8-28); they are not used. Cell, channel, test and conditions are read from it; they are not affected.
- Several cells ran only a few days or weeks (the record's EndTime says so); they have one or two check-ups.
- efc counts every discharge, check-ups and pulses included, over the nominal 3.5 Ah; the record's own efc_spacing (500) is the cyclers' target, so efc at the second check-up is near but not exactly 500.
- Temperature: the files' column is empty and the record states no test temperature.
- Each point is a check-up: the discharge capacity at a slow check-up, against the equivalent full cycles (efc) run before it, counting every discharge over the nominal 3.5 Ah. Most cells were checked at 0.1 A; a few older tests used 0.7 A, or 0.7 A held at 2.5 V until 0.1 A, and get one line per kind. Several cells ran only days or weeks and have one or two check-ups. The ten 10 s pulse resistances of each check-up are in the CSV, not drawn.
Licence and how to cite
The values are published under CC BY 4.0, as the source is. Credit it as follows.
Cite: Thorbjørnsen, K., Bakdi, A., Kandepu, R., Mousteau, O., Clark, S. Lithium Ion Battery Test Dataset for Maritime Transport INR18650-MJ1 (1.0.0). Zenodo (2024). doi:10.5281/zenodo.13318553
Credit: Data: Thorbjørnsen, K., Bakdi, A., Kandepu, R., Mousteau, O., Clark, S. (Corvus Energy, SINTEF), EU project HYDRA (Horizon 2020 grant 875527), doi:10.5281/zenodo.13318553, CC BY 4.0. Check-up values computed by Lemonergy (battery-data).
Values pinned to battery-data revision e85dd43. The manifest names every source file by its SHA-256; the CSV’s own SHA-256 is d55922c0783083640d35f9d5504db89b340def66bb771024d50e58903e221d1b.
Related
- XJTU battery ageing data: 55 Lishen 18650 cells, cycle by cycle
- CALCE CS2 battery ageing data: 15 LiCoO2 cells, cycle by cycle
- Tongji/KIT NCA ageing data: 66 18650 cells, cycle by cycle
- Tongji/KIT NCM ageing data: 55 18650 cells, cycle by cycle
- Tongji/KIT NCM+NCA ageing data: 9 18650 cells at three discharge rates
- Michigan VTC6 data: 194 characterisations of 70 aged 18650 cells
- CMU eVTOL battery data: 22 VTC6 cells under aircraft missions
- NASA PCoE battery ageing data: 34 18650 cells, cycle by cycle
- Oxford battery degradation data: 8 Kokam pouch cells, test by test
- UConn LFP ageing data: 64 18650 cells under 11 cycling conditions
- REBELION ageing data: 160 Samsung 50E cells, four cycling strategies
- TEMPEST ageing data: a 280 Ah LFP cell over 700 cycles at 1C
- LiBforSecUse ageing data: 34 18650 NMC811 cells, 13 life-cycle tests
- VERSAPRINT cycle data: one Lishen 51 Ah cell, nine cycles
- EVERLASTING ageing data: 28 Samsung 35E cells under drive cycles
- FreeTwinEV module data: four Molicel P45B cells in parallel, 14 runs
- All open battery ageing data on Lemonergy