 "schema_version": 1,
 "dataset": "freetwinev-p45b-1s4p-2026",
 "title": "Electro-thermal measurements of a 1s4p Molicel INR21700-P45B battery module (14 runs, one row per run)",
 "publisher": "Slovak University of Technology in Bratislava, for the EU project FreeTwinEV",
 "citation": "Plzák, M., Berta, Š., Ürge, A., Baťa, M. P45B 1s4p Battery Module Measurement (README title: Electro-Thermal Measurements of a 1s4p Molicel INR21700-P45B Battery Module). Zenodo (2026). doi:10.5281/zenodo.18405243",
 "doi": "10.5281/zenodo.18405243",
 "landing": "https://zenodo.org/records/18405243",
 "published": "2026-01-28",
 "license": "CC BY 4.0",
 "license_url": "https://creativecommons.org/licenses/by/4.0/",
 "license_evidence": "Zenodo record 18405243 API metadata license id cc-by-4.0, and the zip's own LICENSE.txt ('This dataset is licensed under the Creative Commons Attribution 4.0 International License.'); checked 2026-11-12",
 "attribution": "Data: Plzák, Berta, Ürge, Baťa (Slovak University of Technology in Bratislava), EU project FreeTwinEV (Horizon Europe grant 101159989), doi:10.5281/zenodo.18405243, CC BY 4.0. Per-run values computed by Lemonergy (battery-data); the time series are not reproduced.",
 "redistributable": true,
 "retrieved_at": "2026-11-12",
 "eu_project": {
  "acronym": "FreeTwinEV",
  "programme": "Horizon Europe",
  "grant": "101159989",
  "cordis": "https://cordis.europa.eu/project/id/101159989"
 },
 "product_uid": "module/stu-bratislava/freetwinev-1s4p-p45b-module",
 "product_kind": "module",
 "cells": {
  "maker": "Molicel",
  "model": "INR-21700-P45B (the record: 'Molicel INR21700-P45B', 'Molicel INR-21700-P45B')",
  "library_record": "cell/molicel/inr21700-p45b",
  "format": "21700",
  "chemistry": null,
  "count": 4,
  "configuration": "1S4P (four cells in parallel; the Protocol sheet: 'Configuration | 1S4P')",
  "nominal_capacity_ah": null,
  "nominal_capacity_basis": "none: the record states no capacity for the module, so capacities are checked only for sign, not against a nominal",
  "per_cell_current": "not measured: the files log the module's current and voltage only",
  "test_conditions": "Protocol sheet: voltage 2.5 to 4.2 V, maximum cell surface temperature 70 °C, ambient 23 °C; each run starts from a full charge, rests, brings the coolant to its setpoint, waits for the module to settle, then discharges at constant current to 2.5 V or until a cell surface reaches 70 °C, rests, is charged CC-CV at 15 A to 4.2 V and with the coolant stopped returns to ambient (steps 1 to 8); the logger records the charge and the last step only in some runs (Test_Matrix, 'DAQ Scan ON @STEP 7' and '@STEP 8')."
 },
 "batches": {
  "discharge -20 A, coolant 25 °C, flow 1.5 l/min": "Test_Matrix: discharge current -20 A, charge current 15 A, coolant 25 °C, flow 1.5 l/min; run(s) ID01",
  "discharge -40 A, coolant 25 °C, flow 1.5 l/min": "Test_Matrix: discharge current -40 A, charge current 15 A, coolant 25 °C, flow 1.5 l/min; run(s) ID02",
  "discharge -40 A, coolant 15 °C, flow 1.5 l/min": "Test_Matrix: discharge current -40 A, charge current 15 A, coolant 15 °C, flow 1.5 l/min; run(s) ID11, ID20",
  "discharge -80 A, coolant 15 °C, flow 1.5 l/min": "Test_Matrix: discharge current -80 A, charge current 15 A, coolant 15 °C, flow 1.5 l/min; run(s) ID12",
  "discharge -120 A, coolant 15 °C, flow 1.5 l/min": "Test_Matrix: discharge current -120 A, charge current 15 A, coolant 15 °C, flow 1.5 l/min; run(s) ID13",
  "discharge -40 A, coolant 15 °C, flow 0.5 l/min": "Test_Matrix: discharge current -40 A, charge current 15 A, coolant 15 °C, flow 0.5 l/min; run(s) ID14",
  "discharge -80 A, coolant 15 °C, flow 0.5 l/min": "Test_Matrix: discharge current -80 A, charge current 15 A, coolant 15 °C, flow 0.5 l/min; run(s) ID15",
  "discharge -120 A, coolant 15 °C, flow 0.5 l/min": "Test_Matrix: discharge current -120 A, charge current 15 A, coolant 15 °C, flow 0.5 l/min; run(s) ID16",
  "discharge -40 A, coolant 15 °C, flow 0.1 l/min": "Test_Matrix: discharge current -40 A, charge current 15 A, coolant 15 °C, flow 0.1 l/min; run(s) ID17",
  "discharge -80 A, coolant 15 °C, flow 0.1 l/min": "Test_Matrix: discharge current -80 A, charge current 15 A, coolant 15 °C, flow 0.1 l/min; run(s) ID18",
  "discharge -120 A, coolant 15 °C, flow 0.1 l/min": "Test_Matrix: discharge current -120 A, charge current 15 A, coolant 15 °C, flow 0.1 l/min; run(s) ID19",
  "discharge -40 A, coolant 5 °C, flow 1.5 l/min": "Test_Matrix: discharge current -40 A, charge current 15 A, coolant 5 °C, flow 1.5 l/min; run(s) ID21",
  "discharge -80 A, coolant 5 °C, flow 1.5 l/min": "Test_Matrix: discharge current -80 A, charge current 15 A, coolant 5 °C, flow 1.5 l/min; run(s) ID22"
 },
 "archive": {
  "name": "1s4p Battery Module Measurement.zip",
  "bytes": 30268251,
  "sha256": "81a3fb83a4cc156c9df37c9d0f5926573b7fc8de227dc4c8e137358d185c1e37",
  "md5": "dea7c0e8c7146f517d71979ac546249d",
  "md5_note": "matches the md5 and size Zenodo lists for '1s4p Battery Module Measurement.zip'"
 },
 "source_files": [
  {
   "path": "1s4p Battery Module Measurement/AllData/ID01_20251126_150908248/FreeTwinEV_1s4p_ID_01.csv",
   "cell": "FreeTwinEV_1s4p",
   "cycle": 1,
   "cycles": 1,
   "batch": "discharge -20 A, coolant 25 °C, flow 1.5 l/min",
   "run_id": "ID01",
   "bytes": 1142768,
   "sha256": "aa05b4f6445e6aecdd86db92bade11ef3d722450f53bfae75efc3ef0386bca55",
   "test_matrix": {
    "experiment_id": 1,
    "daq_timestamp": "20251126_150908248",
    "discharge_current_a": -20,
    "charge_current_a": 15,
    "coolant_temp_c": 25,
    "flow_rate_l_min": 1.5,
    "daq_scan_on_step_7": "YES",
    "daq_scan_on_step_8": "YES"
   },
   "rows": 2413,
   "sampling_s": {
    "median": 5.0,
    "min": 4.328,
    "max": 5.532
   },
   "discharge_s": [
    2474.955,
    5500.007
   ],
   "charge_steps": [
    {
     "from_s": 7034.952,
     "to_s": 12049.957,
     "ah": 16.86021,
     "wh": 64.53505,
     "partial": false
    }
   ],
   "gaps_over_10_s": []
  },
  {
   "path": "1s4p Battery Module Measurement/AllData/ID02_20251127_141017875/FreeTwinEV_1s4p_ID_02.csv",
   "cell": "FreeTwinEV_1s4p",
   "cycle": 2,
   "cycles": 1,
   "batch": "discharge -40 A, coolant 25 °C, flow 1.5 l/min",
   "run_id": "ID02",
   "bytes": 347217,
   "sha256": "03a9080d4b3b1e3c31357a78d640fae54535b2e8f27ad39afb94f6ae37e4cade",
   "test_matrix": {
    "experiment_id": 2,
    "daq_timestamp": "20251127_141017875",
    "discharge_current_a": -40,
    "charge_current_a": 15,
    "coolant_temp_c": 25,
    "flow_rate_l_min": 1.5,
    "daq_scan_on_step_7": null,
    "daq_scan_on_step_8": null
   },
   "rows": 728,
   "sampling_s": {
    "median": 5.0,
    "min": 4.843,
    "max": 5.157
   },
   "discharge_s": [
    185.0,
    1670.016
   ],
   "charge_steps": [
    {
     "from_s": 3300.013,
     "to_s": 3635.01,
     "ah": 1.41163,
     "wh": 4.74145,
     "partial": true
    }
   ],
   "gaps_over_10_s": []
  },
  {
   "path": "1s4p Battery Module Measurement/AllData/ID11_20251128_102057991/FreeTwinEV_1s4p_ID_11.csv",
   "cell": "FreeTwinEV_1s4p",
   "cycle": 3,
   "cycles": 1,
   "batch": "discharge -40 A, coolant 15 °C, flow 1.5 l/min",
   "run_id": "ID11",
   "bytes": 507636,
   "sha256": "50ab6d86ad3521867ccb4b475bc5a504a9228d53dcb89073de3ed519d4740e27",
   "test_matrix": {
    "experiment_id": 11,
    "daq_timestamp": "20251128_102057991",
    "discharge_current_a": -40,
    "charge_current_a": 15,
    "coolant_temp_c": 15,
    "flow_rate_l_min": 1.5,
    "daq_scan_on_step_7": null,
    "daq_scan_on_step_8": null
   },
   "rows": 1071,
   "sampling_s": {
    "median": 5.0,
    "min": 3.771,
    "max": 6.236
   },
   "discharge_s": [
    1715.024,
    3190.024
   ],
   "charge_steps": [],
   "gaps_over_10_s": []
  },
  {
   "path": "1s4p Battery Module Measurement/AllData/ID12_20251128_134031152/FreeTwinEV_1s4p_ID_12.csv",
   "cell": "FreeTwinEV_1s4p",
   "cycle": 4,
   "cycles": 1,
   "batch": "discharge -80 A, coolant 15 °C, flow 1.5 l/min",
   "run_id": "ID12",
   "bytes": 545335,
   "sha256": "9ce55a9ca416c9fb5b77f3cc7949eb0345f0ee2ab7a9d5bd6bd6145fd84ef19a",
   "test_matrix": {
    "experiment_id": 12,
    "daq_timestamp": "20251128_134031152",
    "discharge_current_a": -80,
    "charge_current_a": 15,
    "coolant_temp_c": 15,
    "flow_rate_l_min": 1.5,
    "daq_scan_on_step_7": null,
    "daq_scan_on_step_8": null
   },
   "rows": 1153,
   "sampling_s": {
    "median": 5.0,
    "min": 4.214,
    "max": 6.194
   },
   "discharge_s": [
    2370.002,
    3100.017
   ],
   "charge_steps": [],
   "gaps_over_10_s": []
  },
  {
   "path": "1s4p Battery Module Measurement/AllData/ID13_20251201_113728861/FreeTwinEV_1s4p_ID_13.csv",
   "cell": "FreeTwinEV_1s4p",
   "cycle": 5,
   "cycles": 1,
   "batch": "discharge -120 A, coolant 15 °C, flow 1.5 l/min",
   "run_id": "ID13",
   "bytes": 1418139,
   "sha256": "4368b32ddf793f463f290b750a4bab7ef4ec5787207f0cb06cd4a460a43fd61a",
   "test_matrix": {
    "experiment_id": 13,
    "daq_timestamp": "20251201_113728861",
    "discharge_current_a": -120,
    "charge_current_a": 15,
    "coolant_temp_c": 15,
    "flow_rate_l_min": 1.5,
    "daq_scan_on_step_7": "YES",
    "daq_scan_on_step_8": "YES"
   },
   "rows": 3012,
   "sampling_s": {
    "median": 5.0,
    "min": 3.422,
    "max": 6.465
   },
   "discharge_s": [
    2295.009,
    2714.999
   ],
   "charge_steps": [
    {
     "from_s": 5160.014,
     "to_s": 9775.014,
     "ah": 14.20906,
     "wh": 55.56761,
     "partial": false
    },
    {
     "from_s": 14349.999,
     "to_s": 14610.013,
     "ah": 0.06062,
     "wh": 0.25461,
     "partial": false
    }
   ],
   "gaps_over_10_s": []
  },
  {
   "path": "1s4p Battery Module Measurement/AllData/ID14_20251201_163543484/FreeTwinEV_1s4p_ID_14.csv",
   "cell": "FreeTwinEV_1s4p",
   "cycle": 6,
   "cycles": 1,
   "batch": "discharge -40 A, coolant 15 °C, flow 0.5 l/min",
   "run_id": "ID14",
   "bytes": 427013,
   "sha256": "185b832694da7ac8236e61d5a48810b535df3ee7cb43289705c8c217a0b8c0ce",
   "test_matrix": {
    "experiment_id": 14,
    "daq_timestamp": "20251201_163543484",
    "discharge_current_a": -40,
    "charge_current_a": 15,
    "coolant_temp_c": 15,
    "flow_rate_l_min": 0.5,
    "daq_scan_on_step_7": null,
    "daq_scan_on_step_8": null
   },
   "rows": 904,
   "sampling_s": {
    "median": 5.0,
    "min": 4.796,
    "max": 5.218
   },
   "discharge_s": [
    1370.089,
    2845.025
   ],
   "charge_steps": [],
   "gaps_over_10_s": []
  },
  {
   "path": "1s4p Battery Module Measurement/AllData/ID15_20251202_133030514/FreeTwinEV_1s4p_ID_15.csv",
   "cell": "FreeTwinEV_1s4p",
   "cycle": 7,
   "cycles": 1,
   "batch": "discharge -80 A, coolant 15 °C, flow 0.5 l/min",
   "run_id": "ID15",
   "bytes": 525585,
   "sha256": "600f161a0f53c0fa3b004e00b07c869afb9daf203e46cac1c8be419a595eb779",
   "test_matrix": {
    "experiment_id": 15,
    "daq_timestamp": "20251202_133030514",
    "discharge_current_a": -80,
    "charge_current_a": 15,
    "coolant_temp_c": 15,
    "flow_rate_l_min": 0.5,
    "daq_scan_on_step_7": null,
    "daq_scan_on_step_8": null
   },
   "rows": 1117,
   "sampling_s": {
    "median": 5.0,
    "min": 4.868,
    "max": 5.122
   },
   "discharge_s": [
    2490.017,
    3220.0
   ],
   "charge_steps": [],
   "gaps_over_10_s": []
  },
  {
   "path": "1s4p Battery Module Measurement/AllData/ID16_20251203_103357473/FreeTwinEV_1s4p_ID_16.csv",
   "cell": "FreeTwinEV_1s4p",
   "cycle": 8,
   "cycles": 1,
   "batch": "discharge -120 A, coolant 15 °C, flow 0.5 l/min",
   "run_id": "ID16",
   "bytes": 1357881,
   "sha256": "7b9a489538ad24801707b35355fbb7c06c0e38734da78d83ea4dd10af71ea1f5",
   "test_matrix": {
    "experiment_id": 16,
    "daq_timestamp": "20251203_103357473",
    "discharge_current_a": -120,
    "charge_current_a": 15,
    "coolant_temp_c": 15,
    "flow_rate_l_min": 0.5,
    "daq_scan_on_step_7": "YES",
    "daq_scan_on_step_8": null
   },
   "rows": 2915,
   "sampling_s": {
    "median": 5.0,
    "min": 4.798,
    "max": 5.186
   },
   "discharge_s": [
    7150.0,
    7510.001
   ],
   "charge_steps": [
    {
     "from_s": 9805.0,
     "to_s": 13955.018,
     "ah": 12.21931,
     "wh": 48.39717,
     "partial": false
    }
   ],
   "gaps_over_10_s": []
  },
  {
   "path": "1s4p Battery Module Measurement/AllData/ID17_20251204_111640041/FreeTwinEV_1s4p_ID_17.csv",
   "cell": "FreeTwinEV_1s4p",
   "cycle": 9,
   "cycles": 1,
   "batch": "discharge -40 A, coolant 15 °C, flow 0.1 l/min",
   "run_id": "ID17",
   "bytes": 557695,
   "sha256": "eb1e7d6eff27bf371da9fb794f0ec147935ab4cde44daf95e9a321c6cdd09ac0",
   "test_matrix": {
    "experiment_id": 17,
    "daq_timestamp": "20251204_111640041",
    "discharge_current_a": -40,
    "charge_current_a": 15,
    "coolant_temp_c": 15,
    "flow_rate_l_min": 0.1,
    "daq_scan_on_step_7": null,
    "daq_scan_on_step_8": null
   },
   "rows": 1182,
   "sampling_s": {
    "median": 5.0,
    "min": 4.887,
    "max": 5.122
   },
   "discharge_s": [
    2629.989,
    4105.014
   ],
   "charge_steps": [],
   "gaps_over_10_s": []
  },
  {
   "path": "1s4p Battery Module Measurement/AllData/ID18_20251204_144331500/FreeTwinEV_1s4p_ID_18.csv",
   "cell": "FreeTwinEV_1s4p",
   "cycle": 10,
   "cycles": 1,
   "batch": "discharge -80 A, coolant 15 °C, flow 0.1 l/min",
   "run_id": "ID18",
   "bytes": 594925,
   "sha256": "0d9b42f9cffff669311ad5c835b1285e895b864790b50f7fac5bbdde95145fbf",
   "test_matrix": {
    "experiment_id": 18,
    "daq_timestamp": "20251204_144331500",
    "discharge_current_a": -80,
    "charge_current_a": 15,
    "coolant_temp_c": 15,
    "flow_rate_l_min": 0.1,
    "daq_scan_on_step_7": null,
    "daq_scan_on_step_8": null
   },
   "rows": 1254,
   "sampling_s": {
    "median": 5.0,
    "min": 4.877,
    "max": 5.124
   },
   "discharge_s": [
    2320.001,
    3045.001
   ],
   "charge_steps": [],
   "gaps_over_10_s": []
  },
  {
   "path": "1s4p Battery Module Measurement/AllData/ID19_20251205_120936377/FreeTwinEV_1s4p_ID_19.csv",
   "cell": "FreeTwinEV_1s4p",
   "cycle": 11,
   "cycles": 1,
   "batch": "discharge -120 A, coolant 15 °C, flow 0.1 l/min",
   "run_id": "ID19",
   "bytes": 1045527,
   "sha256": "fc651fba8675183aaba6b4db5b33203b86df66ef5c03746e7a31598f0835a64b",
   "test_matrix": {
    "experiment_id": 19,
    "daq_timestamp": "20251205_120936377",
    "discharge_current_a": -120,
    "charge_current_a": 15,
    "coolant_temp_c": 15,
    "flow_rate_l_min": 0.1,
    "daq_scan_on_step_7": "YES",
    "daq_scan_on_step_8": null
   },
   "rows": 2219,
   "sampling_s": {
    "median": 5.0,
    "min": 4.857,
    "max": 5.129
   },
   "discharge_s": [
    3610.0,
    3980.007
   ],
   "charge_steps": [
    {
     "from_s": 6890.041,
     "to_s": 11070.017,
     "ah": 12.48915,
     "wh": 49.36872,
     "partial": false
    }
   ],
   "gaps_over_10_s": []
  },
  {
   "path": "1s4p Battery Module Measurement/AllData/ID20_20251205_160840427/FreeTwinEV_1s4p_ID_20.csv",
   "cell": "FreeTwinEV_1s4p",
   "cycle": 12,
   "cycles": 1,
   "batch": "discharge -40 A, coolant 15 °C, flow 1.5 l/min",
   "run_id": "ID20",
   "bytes": 575578,
   "sha256": "6aa7aa2b759f1b1b3afb54152be7872cb799f1f2c3876bdea62a81de66fdbbda",
   "test_matrix": {
    "experiment_id": 20,
    "daq_timestamp": "20251205_160840427",
    "discharge_current_a": -40,
    "charge_current_a": 15,
    "coolant_temp_c": 15,
    "flow_rate_l_min": 1.5,
    "daq_scan_on_step_7": null,
    "daq_scan_on_step_8": null
   },
   "rows": 1224,
   "sampling_s": {
    "median": 5.0,
    "min": 4.83,
    "max": 5.158
   },
   "discharge_s": [
    2130.008,
    3595.058
   ],
   "charge_steps": [],
   "gaps_over_10_s": []
  },
  {
   "path": "1s4p Battery Module Measurement/AllData/ID21_20251209_144434492/FreeTwinEV_1s4p_ID_21.csv",
   "cell": "FreeTwinEV_1s4p",
   "cycle": 13,
   "cycles": 1,
   "batch": "discharge -40 A, coolant 5 °C, flow 1.5 l/min",
   "run_id": "ID21",
   "bytes": 678370,
   "sha256": "b9050298e174e7cc7423d005bd7ed0411e9527a31c4b28da8c28914976ff7654",
   "test_matrix": {
    "experiment_id": 21,
    "daq_timestamp": "20251209_144434492",
    "discharge_current_a": -40,
    "charge_current_a": 15,
    "coolant_temp_c": 5,
    "flow_rate_l_min": 1.5,
    "daq_scan_on_step_7": null,
    "daq_scan_on_step_8": null
   },
   "rows": 1433,
   "sampling_s": {
    "median": 5.0,
    "min": 3.413,
    "max": 7.413
   },
   "discharge_s": [
    2715.013,
    4165.026
   ],
   "charge_steps": [],
   "gaps_over_10_s": []
  },
  {
   "path": "1s4p Battery Module Measurement/AllData/ID22_20251210_144332381/FreeTwinEV_1s4p_ID_22.csv",
   "cell": "FreeTwinEV_1s4p",
   "cycle": 14,
   "cycles": 1,
   "batch": "discharge -80 A, coolant 5 °C, flow 1.5 l/min",
   "run_id": "ID22",
   "bytes": 765474,
   "sha256": "9d580fa05d0d04bd68418832d6b62b237f1292cae6e80412b3351f787de801b5",
   "test_matrix": {
    "experiment_id": 22,
    "daq_timestamp": "20251210_144332381",
    "discharge_current_a": -80,
    "charge_current_a": 15,
    "coolant_temp_c": 5,
    "flow_rate_l_min": 1.5,
    "daq_scan_on_step_7": null,
    "daq_scan_on_step_8": null
   },
   "rows": 1622,
   "sampling_s": {
    "median": 5.001,
    "min": 3.915,
    "max": 6.878
   },
   "discharge_s": [
    4115.026,
    4835.04
   ],
   "charge_steps": [],
   "gaps_over_10_s": []
  }
 ],
 "method": "Read with battery-data tools/convert_freetwinev_1s4p.py from the zip, without unpacking: the 14 AllData/<ID>/FreeTwinEV_1s4p_ID_<nn>.csv files (the identical .xlsx copies are not read) and the Test_Matrix sheet of Measurement_Protocol.xlsx. A source entry is one run's CSV (path, bytes, SHA-256 of the file in the zip); its `cycle` is the row it gives. Steps are found in the logged module current: the discharge is the run of rows below -1 A, a charge a run of rows above +0.02 A. Ah and Wh are the trapezoid of current and of current times voltage on the timestamp, from the row before the step to the row after it; an interval longer than 10 s would not be integrated across. Temperatures are converted from kelvin (T - 273.15).",
 "caveats": [
  "The current is the module's. The record does not measure each cell's current, and nothing here divides the module's values among the four cells; only the surface temperatures are per cell.",
  "Temperatures in the files are in kelvin; here they are degrees Celsius (T - 273.15), and differences (cell_rise_max_k, coolant_out_minus_in_*) are in kelvin.",
  "SOC is the logger's own column; the record does not say how it is computed. Over each discharge that ends above 0 % it falls by 100 % per 16.898 to 16.900 Ah of integrated discharge.",
  "Sampling is about every 5 s (median 5.000 s; the longest interval is 7.413 s, in ID21). No run has an interval longer than 10 s, so nothing is left out of the integration.",
  "11 discharges ended at 2.5 V (the last logged row reads 2.518 to 2.553 V) and delivered 16.17 to 16.90 Ah. The 3 discharges at 120 A (ID13, ID16, ID19) ended above it, at 2.825 to 2.963 V, with the hottest cell sensor reading 69.4 to 72.6 °C at the last logged row; the protocol ends a discharge at 2.5 V or at a cell temperature of 70 °C (step 5: 'V_cutoff=2.5V, T_cell≥70') and the record does not say which ended each run. Their 12.20 to 14.21 Ah are not discharges to 2.5 V and do not compare with the others.",
  "A CC-CV charge is logged in 4 runs (ID01, ID13, ID16, ID19); each ends when the module current has fallen to 0.19 to 0.21 A, not at the protocol's 'I_cutoff=50mA' (step 7). The documents do not say whether 50 mA is per cell or for the module; the values are kept as logged.",
  "In ID02 the log ends during the charge (Test_Matrix leaves 'DAQ Scan ON @STEP 7' blank for it): the charge columns hold only the part logged, as the label says.",
  "In ID13 a second, short charge at 4.2 V follows the CC-CV charge after a rest; the record does not say why. It is described in the label and in source_files (charge_steps) and is not in the charge columns.",
  "Measured coolant flow over each discharge is within 25 % of the Test_Matrix setpoint.",
  "ID11 and ID20 have the same Test_Matrix settings and are one batch.",
  "Not imported: the time series themselves (current, voltage, SOC, flow and the 25 temperatures every 5 s), the .xlsx copies of the runs, the photographs, the annotated 3D model, the sensor layout drawing and the material properties of Measurement_Protocol.xlsx, and the .docx note. They are in the record."
 ],
 "columns": {
  "batch": {
   "unit": null,
   "meaning": "the run's settings from Test_Matrix: set discharge current (negative, as printed), coolant temperature and flow rate"
  },
  "cell": {
   "unit": null,
   "meaning": "the module, named as the record's files name it (FreeTwinEV_1s4p); not a cell"
  },
  "cycle": {
   "unit": null,
   "meaning": "run number 1..14 in the order of the record's experiment IDs (run_id)"
  },
  "run_id": {
   "unit": null,
   "meaning": "Experiment ID in Test_Matrix and in the run's folder name (ID01 ... ID22)"
  },
  "daq_timestamp": {
   "unit": null,
   "meaning": "DAQ timestamp of the run as Test_Matrix and the folder name print it (yyyymmdd_hhmmssmmm)"
  },
  "label": {
   "unit": null,
   "meaning": "the steps found in the logged current, in order, with their measured currents and end points"
  },
  "set_discharge_current_a": {
   "unit": "A",
   "meaning": "the module's set discharge current, Test_Matrix Discharge_current [A] as printed (negative = discharge)"
  },
  "set_charge_current_a": {
   "unit": "A",
   "meaning": "the module's set charge current, Test_Matrix Charge_current [A] as printed"
  },
  "set_coolant_temp_c": {
   "unit": "°C",
   "meaning": "Test_Matrix Coolant Temp [°C], the setpoint"
  },
  "set_flow_l_min": {
   "unit": "L/min",
   "meaning": "Test_Matrix Flow Rate [l/min], the setpoint"
  },
  "duration_s": {
   "unit": "s",
   "meaning": "first to last timestamp of the run's file"
  },
  "discharge_duration_s": {
   "unit": "s",
   "meaning": "first to last row of the discharge step (module current below -1 A)"
  },
  "discharge_current_mean_a": {
   "unit": "A",
   "meaning": "mean logged module current over the discharge step (negative = discharge, as logged)"
  },
  "discharge_ah": {
   "unit": "Ah",
   "meaning": "module charge delivered in the discharge step: logged module current integrated over the timestamp (trapezoid), including the interval on each side of the step"
  },
  "discharge_wh": {
   "unit": "Wh",
   "meaning": "module energy delivered in the discharge step: logged module current times module voltage, integrated as discharge_ah"
  },
  "discharge_v_end": {
   "unit": "V",
   "meaning": "module voltage at the last row of the discharge step"
  },
  "cell_max_at_discharge_end_c": {
   "unit": "°C",
   "meaning": "highest of the 12 cell-surface sensors at the last row of the discharge step (converted from K)"
  },
  "charge_duration_s": {
   "unit": "s",
   "meaning": "first to last row of the first charge step after the discharge (module current above +0.02 A); empty if no charge is logged"
  },
  "charge_ah": {
   "unit": "Ah",
   "meaning": "module charge taken in that charge step, integrated as discharge_ah; empty if none (see label for a partial charge)"
  },
  "charge_wh": {
   "unit": "Wh",
   "meaning": "module energy taken in that charge step, integrated as discharge_wh"
  },
  "charge_end_current_a": {
   "unit": "A",
   "meaning": "module current at the last row of that charge step"
  },
  "charge_end_v": {
   "unit": "V",
   "meaning": "module voltage at the last row of that charge step"
  },
  "v_start": {
   "unit": "V",
   "meaning": "module voltage at the first row of the run"
  },
  "v_end": {
   "unit": "V",
   "meaning": "module voltage at the last row of the run"
  },
  "v_min": {
   "unit": "V",
   "meaning": "lowest module voltage in the run"
  },
  "v_max": {
   "unit": "V",
   "meaning": "highest module voltage in the run"
  },
  "soc_start_pct": {
   "unit": "%",
   "meaning": "the logger's SOC column at the first row (the record does not say how it is computed)"
  },
  "soc_discharge_end_pct": {
   "unit": "%",
   "meaning": "the logger's SOC column at the last row of the discharge step"
  },
  "flow_mean_l_min": {
   "unit": "L/min",
   "meaning": "mean logged coolant flow over the discharge step"
  },
  "ambient_mean_c": {
   "unit": "°C",
   "meaning": "mean ambient temperature over the discharge step (converted from K)"
  },
  "inlet_mean_c": {
   "unit": "°C",
   "meaning": "mean coolant inlet temperature over the discharge step (converted from K)"
  },
  "outlet_mean_c": {
   "unit": "°C",
   "meaning": "mean coolant outlet temperature over the discharge step (converted from K)"
  },
  "coolant_out_minus_in_mean_k": {
   "unit": "K",
   "meaning": "mean of coolant outlet minus inlet temperature over the discharge step"
  },
  "coolant_out_minus_in_max_k": {
   "unit": "K",
   "meaning": "largest coolant outlet minus inlet temperature from the start of the discharge to the start of the next charge (or the end of the file)"
  },
  "cell_start_mean_c": {
   "unit": "°C",
   "meaning": "mean of the 12 cell-surface sensors at the first row of the discharge step (converted from K)"
  },
  "cell1_max_c": {
   "unit": "°C",
   "meaning": "highest reading of cell 1's three sensors (TH20-TH22) from the start of the discharge to the start of the next charge or the end of the file (converted from K)"
  },
  "cell2_max_c": {
   "unit": "°C",
   "meaning": "as cell1_max_c, cell 2 (TH17-TH19)"
  },
  "cell3_max_c": {
   "unit": "°C",
   "meaning": "as cell1_max_c, cell 3 (TH14-TH16)"
  },
  "cell4_max_c": {
   "unit": "°C",
   "meaning": "as cell1_max_c, cell 4 (TH11-TH13)"
  },
  "cell_max_c": {
   "unit": "°C",
   "meaning": "highest of cell1_max_c to cell4_max_c"
  },
  "cell_rise_max_k": {
   "unit": "K",
   "meaning": "largest rise of any cell-surface sensor, over the same span, above its own reading at the first row of the discharge"
  },
  "plate_max_c": {
   "unit": "°C",
   "meaning": "highest cooling-plate reading (TH1-TH10) over the same span (converted from K)"
  }
 },
 "files": {
  "cycles.csv": {
   "rows": 14,
   "sha256": "380143cf7f9d03a7a4cfca510288f774693f8939f8ace39bb4d91e1502c67940"
  }
 }
}