Open battery ageing data · EVERLASTING 35E
EVERLASTING ageing data: 28 Samsung 35E cells under drive cycles
The EVERLASTING drive-cycle ageing test (Jöst, Ringbeck, Blömeke and Sauer, RWTH Aachen ISEA, for the EU project EVERLASTING, 2021) aged 28 Samsung INR18650-35E cells of 3.4 Ah, NCA with a silicon-graphite anode, at 25 °C. Each drive cycle charged the cell at 0.3C to 4.05 V and discharged it with a power profile until 80 % of its charge was used, between 10 and 90 % state of charge. About every 30 drive cycles a check-up ran two 0.3C capacity tests, a slow quasi-OCV test and 10 s pulses at 80, 50 and 20 % state of charge. RWTH published every sample (8.8 GB zipped); Lemonergy reduced it to one row per check-up. The pulse resistances are Lemonergy’s own 10 s readings of RWTH’s log, not values RWTH published.
Download every check-up (CSV, 181 kB)Manifest (JSON): files, hashes, unitsChart and Excel downloadOriginal dataset
Free to download, no account needed. Or read it straight into Python:
import pandas as pd
cycles = pd.read_csv("https://lemonergy.com/data/ageing/everlasting-rwth-35e-2021/cycles.csv")- Cells
- 28 cells, 18650; maker: Samsung (Metadata.pdf: 'Cell type Samsung INR18650-35E'); the library files the cell under Samsung SDI
- Chemistry
- NCA/C+Si (as Metadata.pdf states)
- Nominal capacity
- 3.4 Ah
- Check-ups
- 500, one row each
- Test programmes
- 2
- Published by
- RWTH Aachen University, Institute for Power Electronics and Electrical Drives (ISEA), for the EU project EVERLASTING
- Licence
- CC BY 4.0
- Files retrieved
- 2026-11-16
Source: Timeseries data of a drive cycle aging test of 28 high energy NCA/C+Si round cells of type 18650 (check-ups: capacity, qOCV and pulse tests), RWTH Aachen University, Institute for Power Electronics and Electrical Drives (ISEA), for the EU project EVERLASTING, doi:10.18154/RWTH-2021-02814. Licence: CC BY 4.0.
Cite: Jöst, D., Ringbeck, F., Blömeke, A., Sauer, D. U. Timeseries data of a drive cycle aging test of 28 high energy NCA/C+Si round cells of type 18650. RWTH Aachen University (2021). doi:10.18154/RWTH-2021-02814 (also listed on 4TU.ResearchData, doi:10.4121/14307704)
Licence and how to cite · Data quality · Every source file, by SHA-256
Capacity fade, check-up by check-up
Capacity of the first 0.3C capacity test of each check-up, against the drive cycles run before it, one coloured line per cell. Point at a chart to read the values; download them as Excel.
The chart needs JavaScript; every cell’s values are in the table below and in the CSV.
Point at or touch a chart to read every cell’s value at that cycle. Drag across it with a mouse to zoom in. Click a line, or a cell’s name in the legend or table, to show that cell on its own; the others turn grey.Touch a chart to read the values at a cycle. Tap a cell’s name in the legend or the table to show it on its own; the others turn grey.
| Cell | Check-ups | Points drawn | First (Ah) | Last (Ah) | Last / first |
|---|
Every cell
First and last discharge capacity of the check-ups the chart draws, for all 28 cells. Every row of every cell, with all its values, is in the CSV (181 kB).
| Programme | Cell | Check-ups | Points drawn | First (Ah) | Last (Ah) | Last / first |
|---|---|---|---|---|---|---|
| batch 1 (cells 1-20 from 09/2018) | Everlast_35E_001 | 2 | 2 | 3.398 | 3.352 | 98.6 % |
| batch 1 (cells 1-20 from 09/2018) | Everlast_35E_002 | 2 | 2 | 3.390 | 3.355 | 99.0 % |
| batch 1 (cells 1-20 from 09/2018) | Everlast_35E_003 | 3 | 3 | 3.407 | 3.335 | 97.9 % |
| batch 1 (cells 1-20 from 09/2018) | Everlast_35E_004 | 3 | 3 | 3.382 | 3.317 | 98.1 % |
| batch 1 (cells 1-20 from 09/2018) | Everlast_35E_005 | 4 | 4 | 3.390 | 3.275 | 96.6 % |
| batch 1 (cells 1-20 from 09/2018) | Everlast_35E_006 | 4 | 4 | 3.407 | 3.287 | 96.5 % |
| batch 1 (cells 1-20 from 09/2018) | Everlast_35E_007 | 7 | 7 | 3.401 | 3.211 | 94.4 % |
| batch 1 (cells 1-20 from 09/2018) | Everlast_35E_008 | 7 | 7 | 3.371 | 3.208 | 95.2 % |
| batch 1 (cells 1-20 from 09/2018) | Everlast_35E_009 | 33 | 32 | 3.385 | 2.859 | 84.4 % |
| batch 1 (cells 1-20 from 09/2018) | Everlast_35E_010 | 20 | 18 | 3.408 | 2.959 | 86.8 % |
| batch 1 (cells 1-20 from 09/2018) | Everlast_35E_011 | 18 | 18 | 3.391 | 3.053 | 90.0 % |
| batch 1 (cells 1-20 from 09/2018) | Everlast_35E_012 | 18 | 17 | 3.367 | 3.044 | 90.4 % |
| batch 1 (cells 1-20 from 09/2018) | Everlast_35E_013 | 15 | 15 | 3.374 | 3.077 | 91.2 % |
| batch 1 (cells 1-20 from 09/2018) | Everlast_35E_014 | 15 | 14 | 3.379 | 3.081 | 91.2 % |
| batch 1 (cells 1-20 from 09/2018) | Everlast_35E_015 | 32 | 32 | 3.395 | 2.877 | 84.7 % |
| batch 1 (cells 1-20 from 09/2018) | Everlast_35E_016 | 32 | 31 | 3.378 | 2.868 | 84.9 % |
| batch 1 (cells 1-20 from 09/2018) | Everlast_35E_017 | 11 | 11 | 3.389 | 3.104 | 91.6 % |
| batch 1 (cells 1-20 from 09/2018) | Everlast_35E_018 | 11 | 11 | 3.399 | 3.113 | 91.6 % |
| batch 1 (cells 1-20 from 09/2018) | Everlast_35E_019 | 28 | 27 | 3.399 | 2.913 | 85.7 % |
| batch 1 (cells 1-20 from 09/2018) | Everlast_35E_020 | 28 | 28 | 3.390 | 2.904 | 85.7 % |
| batch 2 (cells 22-29 from 03/2019) | Everlast_35E_022 | 28 | 27 | 3.371 | 2.939 | 87.2 % |
| batch 2 (cells 22-29 from 03/2019) | Everlast_35E_023 | 20 | 20 | 3.351 | 2.975 | 88.8 % |
| batch 2 (cells 22-29 from 03/2019) | Everlast_35E_024 | 22 | 22 | 3.368 | 2.955 | 87.7 % |
| batch 2 (cells 22-29 from 03/2019) | Everlast_35E_025 | 28 | 28 | 3.357 | 2.942 | 87.6 % |
| batch 2 (cells 22-29 from 03/2019) | Everlast_35E_026 | 30 | 30 | 3.378 | 2.880 | 85.3 % |
| batch 2 (cells 22-29 from 03/2019) | Everlast_35E_027 | 27 | 27 | 3.365 | 2.936 | 87.2 % |
| batch 2 (cells 22-29 from 03/2019) | Everlast_35E_028 | 27 | 27 | 3.383 | 2.945 | 87.1 % |
| batch 2 (cells 22-29 from 03/2019) | Everlast_35E_029 | 25 | 25 | 3.303 | 2.953 | 89.4 % |
Test programmes
- batch 1 (cells 1-20 from 09/2018). Metadata.pdf: '20 cells starting 09/2018 (Cell 1-20)'; removed piecewise for further examination. Drawn: 0.3C (1.02 A) capacity test of each check-up, against the drive cycles before it.
- batch 2 (cells 22-29 from 03/2019). Metadata.pdf: '8 cells starting 03/2019 (Cell 22-29)'; removed piecewise for further examination. Drawn: 0.3C (1.02 A) capacity test of each check-up, against the drive cycles before it.
Columns of the CSV
Each cell's CSV read from its zip, line by line, with battery-data tools/convert_everlasting_rwth.py (nothing extracted). The publishers' correction (Metadata.pdf 4.2) is applied as written; what it still changed in a file is counted under corrected_by_the_publishers_rule. A step is a run of samples of one sign of current (charge above +0.01 A, discharge below -0.01 A, rest otherwise); its charge is integrated trapezoid between its own samples, an interval over 120 s (a logging gap) not integrated. Steps are classified by the share of their samples at one of the protocol's currents (0.34, 1.02, 1.70, 3.40, 6.80 A, within 1.5 %) and by how they end: a CC-CV charge at 1.02 A that ends below 0.08 A (CV termination) to 4.2 V is a full charge, to 4.05 V a cycling charge; a 1.02 A or 0.34 A discharge ending at or below 2.66 V reached the 2.65 V cut-off; a run of 8 to 12 s with 80 % of its samples at 1.70, 3.40 or 6.80 A is a pulse. The data are cut at each cycling charge; what follows one is a drive cycle when it discharges 1 Ah or more outside the protocol's tests. A window between two cycling charges that holds a test is a check-up. Gates: a capacity test or qOCV discharge must follow a full CC-CV charge with only rest between, at most 2 h of it, and hold no logging gap; a qOCV charge must follow its discharge with only rest between, reach 4.2 V and hold no gap; a pulse group must follow a full charge with its pulses in the protocol's order (discharge then charge at 1.70, 3.40, 6.80 A), and the charge removed since the full charge must put it at 80, 50 or 20 % SOC (within 1.5 points) of the check-up's first capacity test, or of its qOCV discharge when it has none; a pulse is filed when it lasted 8 to 12 s with 50 s or more of rest just before it. The full charge before a capacity test is filed only when it holds no logging gap. A rest of three days or more ends a check-up. A test that fails a gate is left out and named under its cell. Samples without a current (rows of NaN that some files log about every 10 s) are skipped and integrated across. Values rounded: Ah to 5 decimals, volts to 4, mOhm to 3, degC to 2.
| Column | Unit | Meaning |
|---|---|---|
batch | – | the record's cell batch: cells 1-20 started 09/2018, cells 22-29 started 03/2019 (Metadata.pdf section 2; there is no cell 21) |
cell | – | the record's file name for the cell (Everlast_35E_<number>) |
cycle | – | check-up number for this cell, 1-based, in time order (not a cycle count; see drive_cycles) |
label | – | which of the protocol's tests the check-up holds, as found in the data |
date | – | UTC date of the check-up's first capacity-test discharge (or its first test when it has none), from the files' timestamps |
days | d | time from the cell's first logged sample to that discharge |
drive_cycles | – | drive cycles before this check-up: cycling charges (CC-CV to 4.05 V) followed by at least 1 Ah of drive-cycle discharge, counted from the data |
drive_cycles_since_previous | – | drive cycles since the previous check-up (the protocol: every 30) |
efc | – | equivalent full cycles before this check-up: charge discharged by every earlier step, check-ups included, over the nominal 3.4 Ah |
charge_ah | Ah | the full CC-CV charge (1.02 A to 4.2 V, CV until 0.068 A) before the first capacity test, integrated from current |
discharge_ah | Ah | first capacity test of the check-up: CC discharge at 1.02 A (0.3C) to 2.65 V after that charge and a rest, integrated from current |
v_max | V | highest voltage of that charge and discharge |
v_min | V | lowest voltage of the capacity-test discharge (its cut-off) |
duration_s | s | length of the capacity-test discharge |
rest_before_s | s | rest between the full charge and the capacity-test discharge |
temperature_c | degC | mean cell temperature (the measuring PCB's sensor) during the capacity-test discharge; blank where not logged |
capacity_tests | – | capacity tests found in the check-up (the protocol runs two: one before the qOCV test, one after the pulses) |
discharge_ah_test_2 | Ah | second capacity test of the check-up (after the qOCV test and the pulses), the same protocol |
qocv_discharge_ah | Ah | qOCV test: CC discharge at 0.34 A (0.1C) to 2.65 V after a full CC-CV charge and a rest, integrated from current |
qocv_charge_ah | Ah | qOCV test: the CC charge at 0.34 A (0.1C) to 4.2 V that follows it (CC part only; the CV top-up after it is not included) |
dcir_dis_05c_10s_80soc_mohm | mOhm | 10 s discharge pulse at 0.5C (1.70 A) at 80 % SOC: |voltage at the pulse's last sample - rest voltage before it| / current at its last sample; the rest voltage is the last sample at least 0.2 s before the pulse's first sample; computed by Lemonergy |
dcir_cha_05c_10s_80soc_mohm | mOhm | 10 s charge pulse at 0.5C (1.70 A) at 80 % SOC: |voltage at the pulse's last sample - rest voltage before it| / current at its last sample; the rest voltage is the last sample at least 0.2 s before the pulse's first sample; computed by Lemonergy |
dcir_dis_1c_10s_80soc_mohm | mOhm | 10 s discharge pulse at 1C (3.40 A) at 80 % SOC: |voltage at the pulse's last sample - rest voltage before it| / current at its last sample; the rest voltage is the last sample at least 0.2 s before the pulse's first sample; computed by Lemonergy |
dcir_cha_1c_10s_80soc_mohm | mOhm | 10 s charge pulse at 1C (3.40 A) at 80 % SOC: |voltage at the pulse's last sample - rest voltage before it| / current at its last sample; the rest voltage is the last sample at least 0.2 s before the pulse's first sample; computed by Lemonergy |
dcir_dis_2c_10s_80soc_mohm | mOhm | 10 s discharge pulse at 2C (6.80 A) at 80 % SOC: |voltage at the pulse's last sample - rest voltage before it| / current at its last sample; the rest voltage is the last sample at least 0.2 s before the pulse's first sample; computed by Lemonergy |
dcir_cha_2c_10s_80soc_mohm | mOhm | 10 s charge pulse at 2C (6.80 A) at 80 % SOC: |voltage at the pulse's last sample - rest voltage before it| / current at its last sample; the rest voltage is the last sample at least 0.2 s before the pulse's first sample; computed by Lemonergy |
dcir_dis_05c_10s_50soc_mohm | mOhm | 10 s discharge pulse at 0.5C (1.70 A) at 50 % SOC: |voltage at the pulse's last sample - rest voltage before it| / current at its last sample; the rest voltage is the last sample at least 0.2 s before the pulse's first sample; computed by Lemonergy |
dcir_cha_05c_10s_50soc_mohm | mOhm | 10 s charge pulse at 0.5C (1.70 A) at 50 % SOC: |voltage at the pulse's last sample - rest voltage before it| / current at its last sample; the rest voltage is the last sample at least 0.2 s before the pulse's first sample; computed by Lemonergy |
dcir_dis_1c_10s_50soc_mohm | mOhm | 10 s discharge pulse at 1C (3.40 A) at 50 % SOC: |voltage at the pulse's last sample - rest voltage before it| / current at its last sample; the rest voltage is the last sample at least 0.2 s before the pulse's first sample; computed by Lemonergy |
dcir_cha_1c_10s_50soc_mohm | mOhm | 10 s charge pulse at 1C (3.40 A) at 50 % SOC: |voltage at the pulse's last sample - rest voltage before it| / current at its last sample; the rest voltage is the last sample at least 0.2 s before the pulse's first sample; computed by Lemonergy |
dcir_dis_2c_10s_50soc_mohm | mOhm | 10 s discharge pulse at 2C (6.80 A) at 50 % SOC: |voltage at the pulse's last sample - rest voltage before it| / current at its last sample; the rest voltage is the last sample at least 0.2 s before the pulse's first sample; computed by Lemonergy |
dcir_cha_2c_10s_50soc_mohm | mOhm | 10 s charge pulse at 2C (6.80 A) at 50 % SOC: |voltage at the pulse's last sample - rest voltage before it| / current at its last sample; the rest voltage is the last sample at least 0.2 s before the pulse's first sample; computed by Lemonergy |
dcir_dis_05c_10s_20soc_mohm | mOhm | 10 s discharge pulse at 0.5C (1.70 A) at 20 % SOC: |voltage at the pulse's last sample - rest voltage before it| / current at its last sample; the rest voltage is the last sample at least 0.2 s before the pulse's first sample; computed by Lemonergy |
dcir_cha_05c_10s_20soc_mohm | mOhm | 10 s charge pulse at 0.5C (1.70 A) at 20 % SOC: |voltage at the pulse's last sample - rest voltage before it| / current at its last sample; the rest voltage is the last sample at least 0.2 s before the pulse's first sample; computed by Lemonergy |
dcir_dis_1c_10s_20soc_mohm | mOhm | 10 s discharge pulse at 1C (3.40 A) at 20 % SOC: |voltage at the pulse's last sample - rest voltage before it| / current at its last sample; the rest voltage is the last sample at least 0.2 s before the pulse's first sample; computed by Lemonergy |
dcir_cha_1c_10s_20soc_mohm | mOhm | 10 s charge pulse at 1C (3.40 A) at 20 % SOC: |voltage at the pulse's last sample - rest voltage before it| / current at its last sample; the rest voltage is the last sample at least 0.2 s before the pulse's first sample; computed by Lemonergy |
dcir_dis_2c_10s_20soc_mohm | mOhm | 10 s discharge pulse at 2C (6.80 A) at 20 % SOC: |voltage at the pulse's last sample - rest voltage before it| / current at its last sample; the rest voltage is the last sample at least 0.2 s before the pulse's first sample; computed by Lemonergy |
dcir_cha_2c_10s_20soc_mohm | mOhm | 10 s charge pulse at 2C (6.80 A) at 20 % SOC: |voltage at the pulse's last sample - rest voltage before it| / current at its last sample; the rest voltage is the last sample at least 0.2 s before the pulse's first sample; computed by Lemonergy |
Data quality
No per-cell quality verdict was recorded for this dataset. Read the caveats below before comparing cells.
Before comparing cells
- A row is a check-up, not a cycle. drive_cycles counts drive cycles found in the data (a cycling charge to 4.05 V followed by at least 1 Ah of drive-cycle discharge); each check-up is entered from a further cycling charge whose discharge is the check-up's own first step, which is not counted.
- Each check-up holds two capacity tests (discharge_ah before the qOCV test, discharge_ah_test_2 after the pulses); compare like with like.
- The pulse SOCs are the record's 80, 50 and 20 %: the data set them by removing 20 %, then 30 % and 30 % of the check-up's own capacity at 1.02 A. The pulse resistances are a reading of the log (10 s), computed by Lemonergy, not values the record states.
- The publishers' correction (Metadata.pdf 4.2) sets a tester reading of 4.2-4.8 A to 0 A and implausible values to NaN; it is not applied in every file as published, so it is applied here (counts per cell). It touches only drive-cycle currents and outliers, not the check-ups' currents.
- Metadata.pdf 4.1: two long downtimes, during which the cells were stored at different states of charge at 25 °C, show in the capacity afterwards; and some temperature logging failed after December 2020. Gaps over a day are listed per cell (gaps_over_1_day).
- A pulse is filed only when it lasted 8 to 12 s. In 336 check-ups the 2C (6.80 A) charge pulse at 80 % SOC did not last 10 s (median 3.2 s); those cells of the table are blank, and every pulse or test left out is named, with why, under its cell's tests_left_out.
- A rest of three days or more ends a check-up: tests run after a downtime, with no drive cycle since the last check-up, are a row of their own (drive_cycles_since_previous 0).
- The pulse groups are labelled 80, 50 and 20 % SOC as the record names them; the converter checks the charge removed against the check-up's first capacity test, or its qOCV discharge when it has no capacity test.
- Not imported: the drive-cycle time series, the qOCV voltage curves, the pulse time series, and OverviewFigures.zip.
- Each point is a check-up: the capacity of its first 0.3C capacity test, against the drive cycles run before it. A check-up after a downtime of three days or more is a point of its own at the same drive-cycle count, so a line can step there: the publishers say the two long downtimes, when the cells were stored at different states of charge, show in the capacity afterwards. The cells were taken out one by one for further examination, so lines end at different points. Of the 500 check-ups, 492 have a first capacity test; 454 tests that failed one of the converter's checks (most of them pulses that did not last 8 to 12 s) are left out, each named in the manifest. The pulse resistances in the CSV are Lemonergy's own 10 s readings of RWTH's log, not values RWTH published; in 336 check-ups the 2C charge pulse at 80 % SOC did not last 10 s and is blank.
Licence and how to cite
The values are published under CC BY 4.0, as the source is. Credit it as follows.
Cite: Jöst, D., Ringbeck, F., Blömeke, A., Sauer, D. U. Timeseries data of a drive cycle aging test of 28 high energy NCA/C+Si round cells of type 18650. RWTH Aachen University (2021). doi:10.18154/RWTH-2021-02814 (also listed on 4TU.ResearchData, doi:10.4121/14307704)
Credit: Data: Jöst, D., Ringbeck, F., Blömeke, A., Sauer, D. U. (RWTH Aachen University, ISEA), EU project EVERLASTING (Horizon 2020 grant 713771), doi:10.18154/RWTH-2021-02814, CC BY 4.0. Check-up values computed by Lemonergy (battery-data).
Values pinned to battery-data revision e85dd43. The manifest names every source file by its SHA-256; the CSV’s own SHA-256 is 8b42ef9571602d09caa1d284bb5c7a8b719ea5107c478881e53d2a5b6eca9fbb.
Related
- XJTU battery ageing data: 55 Lishen 18650 cells, cycle by cycle
- CALCE CS2 battery ageing data: 15 LiCoO2 cells, cycle by cycle
- Tongji/KIT NCA ageing data: 66 18650 cells, cycle by cycle
- Tongji/KIT NCM ageing data: 55 18650 cells, cycle by cycle
- Tongji/KIT NCM+NCA ageing data: 9 18650 cells at three discharge rates
- Michigan VTC6 data: 194 characterisations of 70 aged 18650 cells
- CMU eVTOL battery data: 22 VTC6 cells under aircraft missions
- NASA PCoE battery ageing data: 34 18650 cells, cycle by cycle
- Oxford battery degradation data: 8 Kokam pouch cells, test by test
- UConn LFP ageing data: 64 18650 cells under 11 cycling conditions
- HYDRA ageing data: 32 LG MJ1 18650 cells under ship-like cycling
- REBELION ageing data: 160 Samsung 50E cells, four cycling strategies
- TEMPEST ageing data: a 280 Ah LFP cell over 700 cycles at 1C
- LiBforSecUse ageing data: 34 18650 NMC811 cells, 13 life-cycle tests
- VERSAPRINT cycle data: one Lishen 51 Ah cell, nine cycles
- FreeTwinEV module data: four Molicel P45B cells in parallel, 14 runs
- All open battery ageing data on Lemonergy
- How these datasets were imported and checked
- Find and compare battery cells