lemonergy/ data Sign in

Open battery ageing data · VERSAPRINT Lishen 51 Ah

VERSAPRINT cycle data: one Lishen 51 Ah cell, nine cycles

The VERSAPRINT record (Weick, CEA, for the EU project VERSAPRINT, 2025) cycled one Lishen cell of 51 Ah nine times: six cycles with a 1C (about 51 A) discharge, then three with a 2C (about 102 A) discharge, each after a 1C charge. The record names the maker, Lishen, but not the model, the format or the chemistry. It set out to measure swelling, but its files hold no swelling values, so none are published. Lemonergy computed one row per cycle from the record’s 19 cycler files. This is a short test, not an ageing campaign: it shows the cell’s capacity at two rates, not its fade.

Free to download, no account needed. Or read it straight into Python:

import pandas as pd
cycles = pd.read_csv("https://lemonergy.com/data/ageing/versaprint-lishen-51ah-2024/cycles.csv")
Cells
1 cell, format not stated by this record; maker: Lishen (the record: 'Lishen cell test 51Ah')
Chemistry
not stated by this record
Nominal capacity
51 Ah
Cycles
9, one row each
Test programmes
2
Published by
CEA (Commissariat à l'énergie atomique et aux énergies alternatives) for the EU project VERSAPRINT
Licence
CC BY 4.0
Files retrieved
2026-11-14

Source: VERSAPRINT cycle test of one Lishen 51 Ah cell ('Cycle tests of Lishen Cell for swelling mesurement'), CEA (Commissariat à l'énergie atomique et aux énergies alternatives) for the EU project VERSAPRINT, doi:10.5281/zenodo.17485458. Licence: CC BY 4.0.

Cite: Weick, C., Atomic Energy and Alternative Energy Commission (CEA). Cycle tests of Lishen Cell for swelling mesurement. Zenodo (2025). doi:10.5281/zenodo.17485458

Licence and how to cite · Data quality · Every source file, by SHA-256

Discharge capacity, cycle by cycle

Discharge capacity of each cycle, one line per discharge rate: 1C for cycles 1 to 6, 2C for cycles 7 to 9. Point at a chart to read the values; download them as Excel.

The chart needs JavaScript; every cell’s values are in the table below and in the CSV.

Every cell

First and last discharge capacity of the cycles the chart draws, for both lines of the one cell. Every row of every cell, with all its values, is in the CSV (2 kB).

ProgrammeCellCycles runPoints drawnFirst (Ah)Last (Ah)Last / first
1C charge, 1C dischargeVERSAPRINT_Lishen_51Ah at 1C discharge9652.36752.353100.0 %
1C charge, 2C dischargeVERSAPRINT_Lishen_51Ah at 2C discharge9352.73652.65299.8 %

Test programmes

Columns of the CSV

Each of the record's 19 cycler files (one step each) read with tools/convert_versaprint_lishen_51ah.py. Files are ordered by the clock time in their names and grouped into cycles: the charge file(s) and the discharge file that follows. Charge and discharge are integrated from each file's own current and time with tools/cyclers.py integrate_cycle (rule right_rectangle, the default) and summed over the cycle's files; *_reported is the cycler's Ah_Charge / Ah_Discharge at each file's last logged row, summed likewise. Rows whose Voltage is outside 1-5 V or whose |Current| is 200 A or more are left out (only in 15_Charge_1C_..._05h28, see caveats).

ColumnUnitMeaning
batch–the cycle's rates, from its file names
cell–the one cell of the record
cycle–cycle number, 1-based, in the clock order of the files
label–the cycle's files (names without .xlsx) and what is irregular about the cycle
charge_ahAhcharge integrated from current over the cycle's charge file(s)
discharge_ahAhdischarge integrated from current over the cycle's discharge file
charge_ah_reportedAhthe cycler's Ah_Charge at the last logged row of each charge file, summed
discharge_ah_reportedAhthe cycler's Ah_Discharge at the last logged row of the discharge file
coulombic_efficiency–discharge_ah / charge_ah
v_maxVhighest cycler Voltage in the cycle's logged rows
v_minVlowest cycler Voltage in the cycle's logged rows
duration_sslogged time of the cycle's files (the rests between files are not logged)
start_test_time_ssfrom the first file's clock time to this cycle's first file's, to the minute the file names give

Data quality

No per-cell quality verdict was recorded for this dataset. Read the caveats below before comparing cells.

Before comparing cells

Licence and how to cite

The values are published under CC BY 4.0, as the source is. Credit it as follows.

Cite: Weick, C., Atomic Energy and Alternative Energy Commission (CEA). Cycle tests of Lishen Cell for swelling mesurement. Zenodo (2025). doi:10.5281/zenodo.17485458

Credit: Data: Weick, C. / CEA, Cycle tests of Lishen Cell for swelling mesurement, EU project VERSAPRINT (Horizon Europe 101103696), doi:10.5281/zenodo.17485458, CC BY 4.0. Per-cycle values computed by Lemonergy (battery-data).

Values pinned to battery-data revision e85dd43. The manifest names every source file by its SHA-256; the CSV’s own SHA-256 is 7df1d94a950ce7b3ca73280730907c5c11ee545a6424d1e3a761724a12b89bda.