Open battery ageing data · VERSAPRINT Lishen 51 Ah
VERSAPRINT cycle data: one Lishen 51 Ah cell, nine cycles
The VERSAPRINT record (Weick, CEA, for the EU project VERSAPRINT, 2025) cycled one Lishen cell of 51 Ah nine times: six cycles with a 1C (about 51 A) discharge, then three with a 2C (about 102 A) discharge, each after a 1C charge. The record names the maker, Lishen, but not the model, the format or the chemistry. It set out to measure swelling, but its files hold no swelling values, so none are published. Lemonergy computed one row per cycle from the record’s 19 cycler files. This is a short test, not an ageing campaign: it shows the cell’s capacity at two rates, not its fade.
Download every cycle (CSV, 2 kB)Manifest (JSON): files, hashes, unitsChart and Excel downloadOriginal dataset
Free to download, no account needed. Or read it straight into Python:
import pandas as pd
cycles = pd.read_csv("https://lemonergy.com/data/ageing/versaprint-lishen-51ah-2024/cycles.csv")- Cells
- 1 cell, format not stated by this record; maker: Lishen (the record: 'Lishen cell test 51Ah')
- Chemistry
- not stated by this record
- Nominal capacity
- 51 Ah
- Cycles
- 9, one row each
- Test programmes
- 2
- Published by
- CEA (Commissariat à l'énergie atomique et aux énergies alternatives) for the EU project VERSAPRINT
- Licence
- CC BY 4.0
- Files retrieved
- 2026-11-14
Source: VERSAPRINT cycle test of one Lishen 51 Ah cell ('Cycle tests of Lishen Cell for swelling mesurement'), CEA (Commissariat à l'énergie atomique et aux énergies alternatives) for the EU project VERSAPRINT, doi:10.5281/zenodo.17485458. Licence: CC BY 4.0.
Cite: Weick, C., Atomic Energy and Alternative Energy Commission (CEA). Cycle tests of Lishen Cell for swelling mesurement. Zenodo (2025). doi:10.5281/zenodo.17485458
Licence and how to cite · Data quality · Every source file, by SHA-256
Discharge capacity, cycle by cycle
Discharge capacity of each cycle, one line per discharge rate: 1C for cycles 1 to 6, 2C for cycles 7 to 9. Point at a chart to read the values; download them as Excel.
The chart needs JavaScript; every cell’s values are in the table below and in the CSV.
Point at or touch a chart to read every cell’s value at that cycle. Drag across it with a mouse to zoom in. Click a line, or a cell’s name in the legend or table, to show that cell on its own; the others turn grey.Touch a chart to read the values at a cycle. Tap a cell’s name in the legend or the table to show it on its own; the others turn grey.
| Cell | Cycles run | Points drawn | First (Ah) | Last (Ah) | Last / first |
|---|
Every cell
First and last discharge capacity of the cycles the chart draws, for both lines of the one cell. Every row of every cell, with all its values, is in the CSV (2 kB).
| Programme | Cell | Cycles run | Points drawn | First (Ah) | Last (Ah) | Last / first |
|---|---|---|---|---|---|---|
| 1C charge, 1C discharge | VERSAPRINT_Lishen_51Ah at 1C discharge | 9 | 6 | 52.367 | 52.353 | 100.0 % |
| 1C charge, 2C discharge | VERSAPRINT_Lishen_51Ah at 2C discharge | 9 | 3 | 52.736 | 52.652 | 99.8 % |
Test programmes
- 1C charge, 1C discharge. file names Charge_1C and Decharge_1C: about 51 A constant-current charge to about 4.19 V (cycler voltage) held until the current falls to about 2.5 A, then about 51 A discharge to about 2.79 V, as the files show; the record states no limits. Drawn: 1C (about 51 A) discharge, every cycle.
- 1C charge, 2C discharge. file names Charge_1C and Decharge_2C: the same charge, then about 102 A discharge to about 2.79 V, as the files show. Drawn: 2C (about 102 A) discharge, every cycle.
Columns of the CSV
Each of the record's 19 cycler files (one step each) read with tools/convert_versaprint_lishen_51ah.py. Files are ordered by the clock time in their names and grouped into cycles: the charge file(s) and the discharge file that follows. Charge and discharge are integrated from each file's own current and time with tools/cyclers.py integrate_cycle (rule right_rectangle, the default) and summed over the cycle's files; *_reported is the cycler's Ah_Charge / Ah_Discharge at each file's last logged row, summed likewise. Rows whose Voltage is outside 1-5 V or whose |Current| is 200 A or more are left out (only in 15_Charge_1C_..._05h28, see caveats).
| Column | Unit | Meaning |
|---|---|---|
batch | – | the cycle's rates, from its file names |
cell | – | the one cell of the record |
cycle | – | cycle number, 1-based, in the clock order of the files |
label | – | the cycle's files (names without .xlsx) and what is irregular about the cycle |
charge_ah | Ah | charge integrated from current over the cycle's charge file(s) |
discharge_ah | Ah | discharge integrated from current over the cycle's discharge file |
charge_ah_reported | Ah | the cycler's Ah_Charge at the last logged row of each charge file, summed |
discharge_ah_reported | Ah | the cycler's Ah_Discharge at the last logged row of the discharge file |
coulombic_efficiency | – | discharge_ah / charge_ah |
v_max | V | highest cycler Voltage in the cycle's logged rows |
v_min | V | lowest cycler Voltage in the cycle's logged rows |
duration_s | s | logged time of the cycle's files (the rests between files are not logged) |
start_test_time_s | s | from the first file's clock time to this cycle's first file's, to the minute the file names give |
Data quality
No per-cell quality verdict was recorded for this dataset. Read the caveats below before comparing cells.
Before comparing cells
- Maker named, model not: the record says only 'Lishen cell test 51Ah'. The cell is filed under Lishen with the record's own designation, cell/lishen/versaprint-51ah, as XJTU's Lishen cells are filed under cell/lishen/unstated; it is not a library record and nothing ties it to a Lishen model. Format and chemistry are not stated by this record (VERSAPRINT's other records describe a 51 Ah prismatic NMC622 cell for their thermal-runaway work; that is not stated for this one).
- No swelling data: the displacement probe the record describes is not among the files' columns; the auxiliary channels V500mV_1-3 are constant over every file and V10_1_1 is the cell voltage. Nothing about swelling is filed.
- Cycle 1 starts from a partial charge (the first file starts at 3.52 V and charges 43.5 Ah): its charge and coulombic efficiency are not a full cycle's.
- Two files are numbered 1 and two 15; the files are ordered by the clock time in their names, not by their numbers.
- Cycle 9's charge stopped after 1,674 s in 15_Charge_1C_bt1_3_ccm_17.05.2024_05h28.xlsx: one row (sheet line 1678) reads 970.9 A and 72.8 V, and the 9,308 rows after it 0 A and 0 V (9,309 rows in all) while the auxiliary 'Ubat' voltage relaxes from 3.70 to 3.65 V. Those rows are left out. The charge resumed in 15_Charge_1C_bt1_3_ccm_17.05.2024_08h35.xlsx and the two files' charges are summed.
- The rests between files are not logged: duration_s is the logged time of the cycle's files, and start_test_time_s counts from the first file's clock time to the minute the file names give.
- Temperatures (24 thermocouples, positions not stated) and the Keithley meter's columns are not imported.
- One cell, nine cycles: six with a 1C (about 51 A) discharge, then three at 2C (about 102 A), each rate a line of its own. The record names the maker, Lishen, but not the model, the format or the chemistry; 51 Ah is the capacity the record states. Cycle 1 starts from a partial charge, so its charge and efficiency are not a full cycle's; cycle 9's charge stopped and was resumed three hours later, and its two parts are summed. Both discharges are whole and are drawn. The capacity integrated from current agrees with the cycler's own counter to 0.021 Ah or better. The record set out to measure swelling, but its files hold no swelling values, so none are published.
Licence and how to cite
The values are published under CC BY 4.0, as the source is. Credit it as follows.
Cite: Weick, C., Atomic Energy and Alternative Energy Commission (CEA). Cycle tests of Lishen Cell for swelling mesurement. Zenodo (2025). doi:10.5281/zenodo.17485458
Credit: Data: Weick, C. / CEA, Cycle tests of Lishen Cell for swelling mesurement, EU project VERSAPRINT (Horizon Europe 101103696), doi:10.5281/zenodo.17485458, CC BY 4.0. Per-cycle values computed by Lemonergy (battery-data).
Values pinned to battery-data revision e85dd43. The manifest names every source file by its SHA-256; the CSV’s own SHA-256 is 7df1d94a950ce7b3ca73280730907c5c11ee545a6424d1e3a761724a12b89bda.
Related
- XJTU battery ageing data: 55 Lishen 18650 cells, cycle by cycle
- CALCE CS2 battery ageing data: 15 LiCoO2 cells, cycle by cycle
- Tongji/KIT NCA ageing data: 66 18650 cells, cycle by cycle
- Tongji/KIT NCM ageing data: 55 18650 cells, cycle by cycle
- Tongji/KIT NCM+NCA ageing data: 9 18650 cells at three discharge rates
- Michigan VTC6 data: 194 characterisations of 70 aged 18650 cells
- CMU eVTOL battery data: 22 VTC6 cells under aircraft missions
- NASA PCoE battery ageing data: 34 18650 cells, cycle by cycle
- Oxford battery degradation data: 8 Kokam pouch cells, test by test
- UConn LFP ageing data: 64 18650 cells under 11 cycling conditions
- HYDRA ageing data: 32 LG MJ1 18650 cells under ship-like cycling
- REBELION ageing data: 160 Samsung 50E cells, four cycling strategies
- TEMPEST ageing data: a 280 Ah LFP cell over 700 cycles at 1C
- LiBforSecUse ageing data: 34 18650 NMC811 cells, 13 life-cycle tests
- EVERLASTING ageing data: 28 Samsung 35E cells under drive cycles
- FreeTwinEV module data: four Molicel P45B cells in parallel, 14 runs
- All open battery ageing data on Lemonergy
- How these datasets were imported and checked
- Find and compare battery cells