Open battery ageing data · Tongji NCA
Tongji/KIT NCA ageing data: 66 18650 cells, cycle by cycle
Dataset_1 of the Tongji University and Karlsruhe Institute of Technology record (Zhu et al., Nature Communications 2022) cycled 66 commercial 18650 NCA cells in five groups: three temperatures (25, 35 and 45 °C) and three charge rates (0.25C, 0.5C and 1C), all discharged at 1C. The record names no maker, no model and no nominal capacity. Lemonergy computed one row of values per charge-discharge cycle from the published files. They are listed below, drawn as capacity fade, and downloadable as a CSV or an Excel workbook.
Download every cycle (CSV, 2.6 MB)Manifest (JSON): files, hashes, unitsChart and Excel downloadOriginal dataset
Free to download, no account needed. Or read it straight into Python:
import pandas as pd
cycles = pd.read_csv("https://lemonergy.com/data/ageing/tongji-2022-nca/cycles.csv")- Cells
- 66 cells, 18650 (the record: 'commercial 18650 type batteries'); maker not stated
- Chemistry
- NCA (as the record names the set)
- Nominal capacity
- not stated
- Cycles
- 22,926, one row each
- Test programmes
- 5
- Published by
- Tongji University / Karlsruhe Institute of Technology
- Licence
- CC BY 4.0
- Files retrieved
- 2026-11-11
Source: Tongji/KIT 18650 cycling dataset, Dataset_1 (NCA battery), Tongji University / Karlsruhe Institute of Technology, doi:10.5281/zenodo.6405084. Licence: CC BY 4.0.
Cite: Zhu, J., Wang, Y., Huang, Y. et al. Data-driven capacity estimation of commercial lithium-ion batteries from voltage relaxation. Nature Communications 13, 2261 (2022). doi:10.1038/s41467-022-29837-w
Licence and how to cite · Data quality · Every source file, by SHA-256
Capacity fade, cycle by cycle
Discharge capacity per cycle, one coloured line per cell, one discharge rate per line. Point at a chart to read the values; download them as Excel.
The chart needs JavaScript; every cell’s values are in the table below and in the CSV.
Point at or touch a chart to read every cell’s value at that cycle. Drag across it with a mouse to zoom in. Click a line, or a cell’s name in the legend or table, to show that cell on its own; the others turn grey.Touch a chart to read the values at a cycle. Tap a cell’s name in the legend or the table to show it on its own; the others turn grey.
| Cell | Cycles run | Points drawn | First (Ah) | Last (Ah) | Last / first |
|---|
Every cell
First and last discharge capacity of the cycles the chart draws, for all 66 cells. Every row of every cell, with all its values, is in the CSV (2.6 MB).
| Programme | Cell | Cycles run | Points drawn | First (Ah) | Last (Ah) | Last / first |
|---|---|---|---|---|---|---|
| CY25-025_1 | CY25-025_1-#1 | 488 | 488 | 3.247 | 2.508 | 77.3 % |
| CY25-025_1 | CY25-025_1-#2 | 235 | 235 | 3.269 | 2.874 | 87.9 % |
| CY25-025_1 | CY25-025_1-#3 | 313 | 300 | 3.204 | 2.496 | 77.9 % |
| CY25-025_1 | CY25-025_1-#4 | 345 | 330 | 3.183 | 2.504 | 78.7 % |
| CY25-025_1 | CY25-025_1-#5 | 352 | 339 | 3.174 | 2.503 | 78.9 % |
| CY25-025_1 | CY25-025_1-#6 | 255 | 246 | 3.229 | 2.504 | 77.6 % |
| CY25-025_1 | CY25-025_1-#7 | 261 | 250 | 3.235 | 2.507 | 77.5 % |
| CY25-05_1 | CY25-05_1-#1 | 146 | 146 | 3.240 | 2.509 | 77.4 % |
| CY25-05_1 | CY25-05_1-#2 | 179 | 179 | 3.243 | 2.502 | 77.2 % |
| CY25-05_1 | CY25-05_1-#3 | 193 | 193 | 3.242 | 2.708 | 83.5 % |
| CY25-05_1 | CY25-05_1-#4 | 194 | 194 | 3.253 | 2.687 | 82.6 % |
| CY25-05_1 | CY25-05_1-#5 | 194 | 194 | 3.251 | 2.615 | 80.4 % |
| CY25-05_1 | CY25-05_1-#6 | 183 | 183 | 3.263 | 2.502 | 76.7 % |
| CY25-05_1 | CY25-05_1-#7 | 173 | 173 | 3.260 | 2.506 | 76.9 % |
| CY25-05_1 | CY25-05_1-#8 | 109 | 109 | 3.287 | 3.010 | 91.6 % |
| CY25-05_1 | CY25-05_1-#9 | 108 | 108 | 3.277 | 3.010 | 91.9 % |
| CY25-05_1 | CY25-05_1-#10 | 208 | 207 | 3.269 | 2.549 | 78.0 % |
| CY25-05_1 | CY25-05_1-#11 | 164 | 158 | 3.240 | 2.501 | 77.2 % |
| CY25-05_1 | CY25-05_1-#12 | 162 | 156 | 3.240 | 2.513 | 77.6 % |
| CY25-05_1 | CY25-05_1-#13 | 194 | 194 | 3.272 | 2.563 | 78.3 % |
| CY25-05_1 | CY25-05_1-#14 | 193 | 193 | 3.267 | 2.523 | 77.2 % |
| CY25-05_1 | CY25-05_1-#15 | 192 | 192 | 3.277 | 2.643 | 80.7 % |
| CY25-05_1 | CY25-05_1-#16 | 164 | 163 | 3.247 | 2.508 | 77.2 % |
| CY25-05_1 | CY25-05_1-#17 | 193 | 193 | 3.250 | 2.578 | 79.3 % |
| CY25-05_1 | CY25-05_1-#18 | 189 | 189 | 3.259 | 2.505 | 76.9 % |
| CY25-05_1 | CY25-05_1-#19 | 154 | 154 | 3.253 | 2.508 | 77.1 % |
| CY25-1_1 | CY25-1_1-#1 | 35 | 34 | 3.142 | 2.508 | 79.8 % |
| CY25-1_1 | CY25-1_1-#2 | 37 | 36 | 3.165 | 2.503 | 79.1 % |
| CY25-1_1 | CY25-1_1-#3 | 29 | 28 | 3.095 | 2.551 | 82.4 % |
| CY25-1_1 | CY25-1_1-#4 | 31 | 29 | 3.076 | 2.524 | 82.0 % |
| CY25-1_1 | CY25-1_1-#5 | 33 | 31 | 3.110 | 2.512 | 80.8 % |
| CY25-1_1 | CY25-1_1-#6 | 29 | 27 | 3.085 | 2.514 | 81.5 % |
| CY25-1_1 | CY25-1_1-#7 | 34 | 33 | 3.167 | 2.513 | 79.3 % |
| CY25-1_1 | CY25-1_1-#8 | 30 | 28 | 3.127 | 2.506 | 80.1 % |
| CY25-1_1 | CY25-1_1-#9 | 33 | 32 | 3.136 | 2.545 | 81.2 % |
| CY35-05_1 | CY35-05_1-#1 | 570 | 549 | 3.296 | 2.502 | 75.9 % |
| CY35-05_1 | CY35-05_1-#2 | 553 | 532 | 3.324 | 2.501 | 75.2 % |
| CY35-05_1 | CY35-05_1-#3 | 32 | 31 | 3.317 | 3.162 | 95.3 % |
| CY45-05_1 | CY45-05_1-#1 | 740 | 712 | 3.349 | 2.500 | 74.7 % |
| CY45-05_1 | CY45-05_1-#2 | 727 | 700 | 3.348 | 2.504 | 74.8 % |
| CY45-05_1 | CY45-05_1-#3 | 207 | 200 | 3.339 | 3.004 | 90.0 % |
| CY45-05_1 | CY45-05_1-#4 | 207 | 200 | 3.333 | 2.965 | 88.9 % |
| CY45-05_1 | CY45-05_1-#5 | 207 | 200 | 3.342 | 2.825 | 84.5 % |
| CY45-05_1 | CY45-05_1-#6 | 207 | 200 | 3.348 | 2.861 | 85.5 % |
| CY45-05_1 | CY45-05_1-#7 | 415 | 400 | 3.335 | 2.826 | 84.8 % |
| CY45-05_1 | CY45-05_1-#8 | 415 | 400 | 3.339 | 2.590 | 77.5 % |
| CY45-05_1 | CY45-05_1-#9 | 415 | 400 | 3.349 | 2.830 | 84.5 % |
| CY45-05_1 | CY45-05_1-#10 | 415 | 400 | 3.335 | 2.737 | 82.1 % |
| CY45-05_1 | CY45-05_1-#11 | 649 | 649 | 3.338 | 2.500 | 74.9 % |
| CY45-05_1 | CY45-05_1-#12 | 800 | 800 | 3.349 | 2.530 | 75.6 % |
| CY45-05_1 | CY45-05_1-#13 | 712 | 712 | 3.344 | 2.501 | 74.8 % |
| CY45-05_1 | CY45-05_1-#14 | 728 | 728 | 3.343 | 2.501 | 74.8 % |
| CY45-05_1 | CY45-05_1-#15 | 496 | 494 | 3.354 | 2.501 | 74.6 % |
| CY45-05_1 | CY45-05_1-#16 | 597 | 595 | 3.361 | 2.550 | 75.9 % |
| CY45-05_1 | CY45-05_1-#17 | 531 | 528 | 3.362 | 2.500 | 74.4 % |
| CY45-05_1 | CY45-05_1-#18 | 598 | 595 | 3.356 | 2.584 | 77.0 % |
| CY45-05_1 | CY45-05_1-#19 | 687 | 685 | 3.361 | 2.501 | 74.4 % |
| CY45-05_1 | CY45-05_1-#20 | 730 | 727 | 3.341 | 2.501 | 74.9 % |
| CY45-05_1 | CY45-05_1-#21 | 640 | 637 | 3.354 | 2.501 | 74.6 % |
| CY45-05_1 | CY45-05_1-#22 | 580 | 577 | 3.361 | 2.500 | 74.4 % |
| CY45-05_1 | CY45-05_1-#23 | 692 | 689 | 3.351 | 2.501 | 74.6 % |
| CY45-05_1 | CY45-05_1-#24 | 723 | 720 | 3.358 | 2.500 | 74.5 % |
| CY45-05_1 | CY45-05_1-#25 | 740 | 737 | 3.341 | 2.500 | 74.8 % |
| CY45-05_1 | CY45-05_1-#26 | 711 | 708 | 3.364 | 2.500 | 74.3 % |
| CY45-05_1 | CY45-05_1-#27 | 652 | 649 | 3.349 | 2.501 | 74.7 % |
| CY45-05_1 | CY45-05_1-#28 | 718 | 716 | 3.357 | 2.500 | 74.5 % |
Test programmes
- CY25-025_1. 7 cells (#1, #2, #3, #4, #5, #6, #7), 25 C, charge 0.25C / discharge 1C, as the file names state; the record states no reference capacity for the C-rates. Drawn: full cycles at 1C discharge.
- CY25-05_1. 19 cells (#1, #2, #3, #4, #5, #6, #7, #8, #9, #10, #11, #12, #13, #14, #15, #16, #17, #18, #19), 25 C, charge 0.5C / discharge 1C, as the file names state; the record states no reference capacity for the C-rates. Drawn: full cycles at 1C discharge.
- CY25-1_1. 9 cells (#1, #2, #3, #4, #5, #6, #7, #8, #9), 25 C, charge 1C / discharge 1C, as the file names state; the record states no reference capacity for the C-rates. Drawn: full cycles at 1C discharge.
- CY35-05_1. 3 cells (#1, #2, #3), 35 C, charge 0.5C / discharge 1C, as the file names state; the record states no reference capacity for the C-rates. Drawn: full cycles at 1C discharge.
- CY45-05_1. 28 cells (#1, #2, #3, #4, #5, #6, #7, #8, #9, #10, #11, #12, #13, #14, #15, #16, #17, #18, #19, #20, #21, #22, #23, #24, #25, #26, #27, #28), 45 C, charge 0.5C / discharge 1C, as the file names state; the record states no reference capacity for the C-rates. Drawn: full cycles at 1C discharge.
Columns of the CSV
Each CSV read straight from Dataset_1_NCA_battery.zip (no extraction) with battery-data tools/convert_tongji_csv.py, which maps it to BDF names and computes its cycles with tools/dataset_cycles.py: the conventions and cycle summary of tools/cyclers.py (current sign detected from the capacity columns; cycle = one charge followed by one discharge; capacity integrated from current; nothing integrated across a recording gap longer than max(20 median sample intervals, 1 h)). The file's own cycle number and per-cycle counters are carried beside the computed values. Values are rounded as printed: Ah to 5 decimals, efficiency and volts to 4, seconds to 0.1.
| Column | Unit | Meaning |
|---|---|---|
batch | – | test condition from the file name, CYX-Y_Z: X temperature in C, Y_Z charge_discharge rate in C ('025' = 0.25, '05' = 0.5) |
cell | – | cell file name without .csv |
cycle | – | cycle number, 1-based, counted by battery-data (one charge followed by one discharge) |
label | – | the file's own 'cycle number' for the cycle; 'run 2' marks the second recording of a file whose clock restarts; '(split)' a file cycle that a recording interruption split in two |
charge_ah | Ah | charge capacity integrated from current |
discharge_ah | Ah | discharge capacity integrated from current |
charge_ah_reported | Ah | largest 'Q charge' of the file cycle, in Ah; blank unless file cycle and computed cycle match one to one |
discharge_ah_reported | Ah | largest 'Q discharge' of the file cycle, in Ah; blank unless file cycle and computed cycle match one to one |
coulombic_efficiency | – | discharge_ah / charge_ah (blank when charge_ah is zero) |
v_max | V | highest cell voltage in the cycle |
v_min | V | lowest cell voltage in the cycle |
duration_s | s | length of the cycle |
start_test_time_s | s | start of the cycle on the file's time axis (made continuous where the file's clock restarts) |
Data quality
No per-cell quality verdict was recorded for this dataset. Read the caveats below before comparing cells.
Before comparing cells
- The record and its zips state no maker, no model, no nominal capacity or voltage and no voltage limits (the zips hold only the cell CSVs; the 'Short discription.txt' in the record's impedance zip covers the impedance files only). The cells are therefore filed under the library's placeholder maker as 'Tongji-KIT Dataset_1 NCA', the record's own folder name, and 'nominal_capacity_ah' is null, so the 1.5 x nominal plausibility check of tools/check_datasets.py does not apply to this folder. The voltage range the cells were cycled over is visible in v_max and v_min, not stated.
- Temperatures and charge/discharge C-rates come from the file names (CYX-Y_Z-#N), as the record describes them; the capacity a C-rate refers to is not stated.
- Current sign: detected from the files' own capacity columns (charge positive); the 'Q charge' and 'Q discharge' counters restart within each file cycle.
- Integrated against reported capacity, over cycles where file cycle and computed cycle match one to one and the reported value exceeds 0.05 Ah: discharge median 0.0 mAh (95th percentile 0.0 mAh, 22709 of 22710 within 10 mAh); charge median 0.01 mAh (95th percentile 0.07 mAh, 22898 of 22901 within 10 mAh).
- 12 cells (CY45-05_1-#17, CY45-05_1-#18, CY45-05_1-#19, CY45-05_1-#20, CY45-05_1-#21, CY45-05_1-#22, CY45-05_1-#23, CY45-05_1-#24, CY45-05_1-#25, CY45-05_1-#26, CY45-05_1-#27, CY45-05_1-#28) have recording gaps longer than an hour with current flowing after them (lengths per file under recording_gaps). Nothing is integrated across a gap. Across every one of these gaps the tester's own Q counters change, and in most the cell voltage too (for example Dataset_1 CY45-05_1-#17: 4.200 V before, 3.911 V after), so current flowed while nothing was logged; how much cannot be read reliably from the counters. The cycles around a gap therefore hold less charge or discharge than the cell saw. Where the interruption falls inside a file cycle the cycle is split in two and labelled '(split)'.
- CY25-05_1-#16: the clock runs backwards at CSV row 903 (26356.9 s to 0.0 s): the file holds a second recording. It is joined end to end one sample interval after the first, so the real gap is unknown, and its file cycles are labelled 'run 2'.
- CY35-05_1-#2: CSV row 69042 (time -37972.4 s, cell voltage 0 V, current 0) is not a measurement and was dropped.
- CY25-05_1-#16 begins with an aborted start (one full cycle and a 45 mAh discharge) before its clock restarts and the test begins again from cycle number 1; both recordings are kept.
- CY25-025_1-#2 cycles 61 and 235 each hold a few samples at 1.1 V and 0.6 V at the start of the rest after the discharge, at zero current; they are kept as recorded and set v_min for those cycles.
- Odd cycles are kept as recorded. Cycles whose integrated and reported capacity differ by more than 10 mAh: CY25-05_1-#10 cycle 132 charge_ah 2.61201 vs 2.62451; CY45-05_1-#18 cycle 202 charge_ah 2.11888 vs 2.13349; CY45-05_1-#19 cycle 219 charge_ah 0.46773 vs 1.12181; CY45-05_1-#19 cycle 219 discharge_ah 1.59686 vs 0.47505. Each lies next to a recording gap or an unlogged start of charge (the first logged sample of the charge already shows charge on the tester's counter). Cycles with no single reported figure: CY25-05_1-#16 cycle 2; CY25-05_1-#16 cycle 3; CY35-05_1-#2 cycle 84; CY45-05_1-#17 cycle 221; CY45-05_1-#17 cycle 222; CY45-05_1-#18 cycle 218; CY45-05_1-#18 cycle 219; CY45-05_1-#20 cycle 218; CY45-05_1-#20 cycle 219; CY45-05_1-#21 cycle 219; CY45-05_1-#21 cycle 220; CY45-05_1-#22 cycle 220; CY45-05_1-#22 cycle 221; CY45-05_1-#23 cycle 217; CY45-05_1-#23 cycle 218; CY45-05_1-#24 cycle 218; CY45-05_1-#24 cycle 219; CY45-05_1-#25 cycle 217; CY45-05_1-#25 cycle 218; CY45-05_1-#26 cycle 218; CY45-05_1-#26 cycle 219; CY45-05_1-#27 cycle 219; CY45-05_1-#27 cycle 220; CY45-05_1-#28 cycle 217; CY45-05_1-#28 cycle 218.
- Spot-checked by hand against the raw CSVs, integrating each file cycle independently: Dataset_1 CY25-025_1-#1 (cycles 1, 299) and CY25-1_1-#2 (four cycles), Dataset_2 CY35-05_1-#3 (four cycles), Dataset_3 CY25-05_4-#3 (four cycles). Discharge, v_max and v_min agree to the last printed digit or within 0.01 mAh; charge within 0.08 mAh in Dataset_1 and 2, and 3.47 mAh low in Dataset_3 as explained above.
Licence and how to cite
The values are published under CC BY 4.0, as the source is. Credit it as follows.
Cite: Zhu, J., Wang, Y., Huang, Y. et al. Data-driven capacity estimation of commercial lithium-ion batteries from voltage relaxation. Nature Communications 13, 2261 (2022). doi:10.1038/s41467-022-29837-w
Credit: Data: Zhu, J., Wang, Y., Huang, Y. et al., Tongji University / Karlsruhe Institute of Technology, Dataset_1 (NCA battery), doi:10.5281/zenodo.6405084, CC BY 4.0. Per-cycle values computed by Lemonergy (battery-data).
Values pinned to battery-data revision e85dd43. The manifest names every source file by its SHA-256; the CSV’s own SHA-256 is a2c393c2f30fcd039ad99446662f882b96b9b481a8281e39b19b157d0caa4afa.
Related
- XJTU battery ageing data: 55 Lishen 18650 cells, cycle by cycle
- CALCE CS2 battery ageing data: 15 LiCoO2 cells, cycle by cycle
- Tongji/KIT NCM ageing data: 55 18650 cells, cycle by cycle
- Tongji/KIT NCM+NCA ageing data: 9 18650 cells at three discharge rates
- Michigan VTC6 data: 194 characterisations of 70 aged 18650 cells
- CMU eVTOL battery data: 22 VTC6 cells under aircraft missions
- NASA PCoE battery ageing data: 34 18650 cells, cycle by cycle
- Oxford battery degradation data: 8 Kokam pouch cells, test by test
- UConn LFP ageing data: 64 18650 cells under 11 cycling conditions
- HYDRA ageing data: 32 LG MJ1 18650 cells under ship-like cycling
- REBELION ageing data: 160 Samsung 50E cells, four cycling strategies
- TEMPEST ageing data: a 280 Ah LFP cell over 700 cycles at 1C
- LiBforSecUse ageing data: 34 18650 NMC811 cells, 13 life-cycle tests
- VERSAPRINT cycle data: one Lishen 51 Ah cell, nine cycles
- EVERLASTING ageing data: 28 Samsung 35E cells under drive cycles
- FreeTwinEV module data: four Molicel P45B cells in parallel, 14 runs
- All open battery ageing data on Lemonergy
- How these datasets were imported and checked
- Find and compare battery cells