lemonergy/ data Sign in

Open battery ageing data · NASA PCoE

NASA PCoE battery ageing data: 34 18650 cells, cycle by cycle

The NASA Ames Prognostics Center of Excellence (Saha and Goebel, 2007) charged and discharged 34 Li-ion 18650 cells of 2 Ah rating in nine groups, at ambient temperatures from 4 to 44 °C, loads of 1 to 4 A and cut-off voltages from 2.0 to 2.7 V. NASA names no maker, no model and no chemistry. Lemonergy computed one row per charge-discharge cycle from the published files, with NASA’s own capacity beside it. NASA states no licence, so its files are not copied here; the computed values are, with the citation NASA asks for.

Free to download, no account needed. Or read it straight into Python:

import pandas as pd
cycles = pd.read_csv("https://lemonergy.com/data/ageing/nasa-pcoe/cycles.csv")
Cells
34 cells, 18650 (data.nasa.gov record: 'Commercially available Li-ion 18650 sized rechargeable batteries'); maker not stated
Chemistry
Li-ion, not further stated
Nominal capacity
2 Ah
Cycles
2,825, one row each
Test programmes
9
Published by
NASA Ames Research Center, Prognostics Center of Excellence
Licence
None stated: computed values only, published with the citation the publisher asks for; the files are not copied
Files retrieved
2026-11-12

Source: NASA Ames PCoE Battery Data Set (Saha and Goebel): 34 Li-ion 18650 cells, charge, discharge and EIS, NASA Ames Research Center, Prognostics Center of Excellence. No licence stated: the values below are computed from its files, which are not copied here.

Cite: B. Saha and K. Goebel (2007). "Battery Data Set", NASA Prognostics Data Repository, NASA Ames Research Center, Moffett Field, CA

Licence and how to cite · Data quality · Every source file, by SHA-256

Capacity fade, cycle by cycle

NASA’s own capacity of each discharge, one coloured line per cell, or per cell and load where its load or temperature changes. One discharge rate per line. Point at a chart to read the values; download them as Excel.

The chart needs JavaScript; every cell’s values are in the table below and in the CSV.

Every cell

First and last discharge capacity of the cycles the chart draws, for all 50 lines and cells. Every row of every cell, with all its values, is in the CSV (335 kB).

ProgrammeCellCycles runPoints drawnFirst (Ah)Last (Ah)Last / first
FY08Q4B00051691681.8571.32571.4 %
FY08Q4B00061691682.0351.18658.3 %
FY08Q4B00071691681.8911.43375.8 %
FY08Q4B00181321321.8551.34172.3 %
25-28B002529281.8471.76895.7 %
25-28B002629281.8131.76997.5 %
25-28B002729281.8231.77097.1 %
25-28B002829281.8051.71795.2 %
29-32B002941401.6981.61295.0 %
29-32B003041401.6561.56394.4 %
29-32B003141401.6671.667100.0 %
29-32B003241401.7051.63695.9 %
33-36B00331981970.0681.3151923.0 %
33-36B00341981970.7461.280171.6 %
33-36B00361981971.0021.559155.6 %
38-40B0038 at 4 A, 24 C48120.8981.008112.3 %
38-40B0038 at 1 A, 44 C48261.7801.77599.7 %
38-40B0038 at 2 A, 44 C4861.7331.72999.7 %
38-40B0038 at 4 A, 44 C4821.5261.530100.3 %
38-40B0039 at 4 A, 24 C48120.1190.413346.8 %
38-40B0039 at 1 A, 44 C48261.7701.74398.5 %
38-40B0039 at 2 A, 44 C4861.6561.61197.3 %
38-40B0039 at 4 A, 44 C4821.3241.31599.3 %
38-40B0040 at 4 A, 24 C48120.6730.715106.2 %
38-40B0040 at 1 A, 44 C48261.7311.72599.7 %
38-40B0040 at 2 A, 44 C4861.6671.64298.5 %
38-40B0040 at 4 A, 44 C4820.4260.557130.8 %
41-44B0041 at 4 A, 4 C68420.0560.04886.9 %
41-44B0041 at 1 A, 4 C68251.2160.83768.8 %
41-44B0042 at 2 A, 22 C113411.7291.56690.6 %
41-44B0042 at 4 A, 4 C113450.0840.06374.3 %
41-44B0042 at 1 A, 4 C113251.4381.33793.0 %
41-44B0043 at 2 A, 22 C113411.7141.47085.7 %
41-44B0043 at 4 A, 4 C113450.0570.062108.2 %
41-44B0043 at 1 A, 4 C113251.5251.27783.7 %
41-44B0044 at 2 A, 22 C113411.6871.41583.9 %
41-44B0044 at 4 A, 4 C113450.0570.062108.0 %
41-44B0044 at 1 A, 4 C113251.4781.24984.5 %
45-48B004573721.0820.60756.1 %
45-48B004673721.7281.15466.8 %
45-48B004773721.6741.15769.1 %
45-48B004873721.6581.22373.8 %
49-52B004926250.8580.69180.5 %
49-52B005126250.6430.678105.3 %
53-56B005356561.0690.0000.0 %
53-56B00541031030.7400.0000.0 %
53-56B00551031020.7990.991124.0 %
53-56B00561031020.7851.129143.8 %
49-52B005026not drawn–––
49-52B005226not drawn–––

Not drawn: B0050, the manifest's quality check calls it not usable: Capacity jumps between 0.03 and 2.64 Ah from cycle to cycle; cycle 6 discharges 3.04 Ah after a 0.00015 Ah charge, which cannot be; charges reach 4.98 V; 4 discharges have no Capacity; the test ended when the control software crashed (README); B0052, the manifest's quality check calls it not usable: After cycle 4 the charges carry about 5 mA while the voltage jumps between 0.3 V and 4.98 V, and 21 of 25 discharges have no Capacity: the cell was not measured properly; the test ended when the control software crashed (README). Their rows are in the CSV.

Test programmes

Columns of the CSV

Each .mat file read from the zip with battery-data tools/convert_nasa_pcoe.py (scipy.io.loadmat; nothing is extracted to disk). The charge and discharge operations are put on one time axis (operation start minus first operation start, plus Time); impedance operations are left out. A cycle is NASA's own: the charge operation(s) since the previous discharge, then one discharge operation; it is passed to tools/dataset_cycles.py as the file's cycle key, and each row is computed with the cycle summary of tools/cyclers.py (current sign read from the operation types: charge positive; capacity integrated from Current_measured with cyclers' step_aware_min rule (docs/36), with the operation as the step: the trapezoid between two samples of one operation, as NASA computes its Capacity, and across two operations the smaller of the two currents (nothing where they differ in sign); nothing integrated across a gap longer than max(20 median intervals, 1 h)). The label names the operations by their 1-based index in the file, the mean discharge current and the ambient temperature. discharge_ah_reported is NASA's Capacity of the discharge operation. B0025-B0028 are in two inner zips, byte for byte the same; each is filed once (also_at). Values are rounded as printed: Ah to 5 decimals, efficiency and volts to 4, seconds to 0.1.

ColumnUnitMeaning
batch–README group of the cell (see batches)
cell–cell file name without .mat (B00##)
cycle–cycle number, 1-based: NASA's charge operation(s) then one discharge operation
label–the file's operations in the cycle (1-based index), mean discharge current, ambient temperature
charge_ahAhcharge integrated from Current_measured over the charge operation(s)
discharge_ahAhdischarge integrated from Current_measured over the whole discharge operation
charge_ah_reportedAhblank: NASA reports no charge figure
discharge_ah_reportedAhNASA's Capacity of the discharge operation (discharged until the voltage first falls below 2.7 V)
coulombic_efficiency–discharge_ah / charge_ah (blank when charge_ah is zero)
v_maxVhighest Voltage_measured in the cycle
v_minVlowest Voltage_measured in the cycle
duration_sslength of the cycle on the joined time axis, unlogged time between operations included
start_test_time_ssstart of the cycle, seconds after the cell's first operation

Data quality

Overall: Of 34 cells, 32 are usable with caveats and 2 are not usable (B0050, B0052); no cell is free of findings. The classic cells B0005, B0006, B0007 and B0018 hold no implausible capacity; their findings are charge-start spikes, discharges whose voltage dips more than 0.15 V below the cut-off and the known capacity jumps after pauses. The 4 C groups (B0041-B0056) hold many irregular runs, as their READMEs warn.

34 cells checked: 0 usable, 32 usable with caveats, 2 not usable.

CellVerdictWhy
B0005usable with caveats2 charge(s) above 4.22 V; 12 discharge(s) go more than 0.15 V below the 2.7 V cut-off; 1 step(s) over 5 % between consecutive Capacities; the charge record of some cycles opens with a voltage spike (up to 8.39 V) and a -4 A sample, at the start of charge
B0006usable with caveats2 charge(s) above 4.22 V; 19 discharge(s) go more than 0.15 V below the 2.5 V cut-off; 3 step(s) over 5 % between consecutive Capacities; charge spikes as B0005 (up to 8.08 V)
B0007usable with caveats2 charge(s) above 4.22 V; 56 discharge(s) go more than 0.15 V below the 2.2 V cut-off; 1 step(s) over 5 % between consecutive Capacities; Capacity (above 0.5 Ah) never falls to the stated end criterion 1.4 Ah (lowest 1.40046 Ah, last 1.43246 Ah); charge spikes as B0005 (up to 8.33 V)
B0018usable with caveats2 charge(s) above 4.22 V; 19 discharge(s) go more than 0.15 V below the 2.5 V cut-off; 4 NaN values in time, voltage or current; 3 step(s) over 5 % between consecutive Capacities
B0025usable with caveats15 discharge(s) go more than 0.15 V below the 2.0 V cut-off; 4 NaN values in time, voltage or current
B0026usable with caveats20 discharge(s) go more than 0.15 V below the 2.2 V cut-off; 4 NaN values in time, voltage or current; 5 step(s) over 5 % between consecutive Capacities
B0027usable with caveats4 NaN values in time, voltage or current
B0028usable with caveats4 discharge(s) go more than 0.15 V below the 2.7 V cut-off; 4 NaN values in time, voltage or current; discharges as a square wave of 2 A amplitude; the README says 4 A for B0025-B0028
B0029usable with caveatsfirst Capacity 1.69751 Ah vs 2 Ah rated; 8 discharge(s) go more than 0.15 V below the 2.0 V cut-off; 1 step(s) over 5 % between consecutive Capacities
B0030usable with caveatsfirst Capacity 1.65607 Ah vs 2 Ah rated; 9 discharge(s) go more than 0.15 V below the 2.2 V cut-off; 1 step(s) over 5 % between consecutive Capacities
B0031usable with caveatsfirst Capacity 1.66668 Ah vs 2 Ah rated; 10 discharge(s) go more than 0.15 V below the 2.5 V cut-off; 1 step(s) over 5 % between consecutive Capacities
B0032usable with caveatsfirst Capacity 1.70486 Ah vs 2 Ah rated; 1 step(s) over 5 % between consecutive Capacities
B0033usable with caveatsfirst Capacity 0.06843 Ah vs 2 Ah rated; 9 discharge(s) with Capacity below 0.5 Ah; 8 charge(s) above 4.22 V; 63 discharge(s) go more than 0.15 V below the 2.0 V cut-off; 4 NaN values in time, voltage or current; 22 step(s) over 5 % between consecutive Capacities; first two discharges 0.07 and 0.68 Ah; capacities 0.2-0.84 Ah in cycles 139-147 between normal values; jumps up to +30 % after pauses
B0034usable with caveatsfirst Capacity 0.74593 Ah vs 2 Ah rated; 48 discharge(s) go more than 0.15 V below the 2.2 V cut-off; 4 NaN values in time, voltage or current; 14 step(s) over 5 % between consecutive Capacities
B0036usable with caveatsfirst Capacity 1.00198 Ah vs 2 Ah rated; 4 NaN values in time, voltage or current; 5 step(s) over 5 % between consecutive Capacities
B0038usable with caveatsfirst Capacity 0.89806 Ah vs 2 Ah rated; 3 discharge(s) go more than 0.15 V below the 2.2 V cut-off; 2 NaN values in time, voltage or current; 4 step(s) over 5 % between consecutive Capacities
B0039usable with caveatsfirst Capacity 0.11904 Ah vs 2 Ah rated; 12 discharge(s) with Capacity below 0.5 Ah; 2 NaN values in time, voltage or current; 7 step(s) over 5 % between consecutive Capacities; the first 12 discharges at 4 A give 0.11-0.47 Ah, then about 1.75 Ah at 1 A
B0040usable with caveatsfirst Capacity 0.67346 Ah vs 2 Ah rated; 1 discharge(s) with Capacity below 0.5 Ah; 2 discharge(s) go more than 0.15 V below the 2.7 V cut-off; 2 NaN values in time, voltage or current; 5 step(s) over 5 % between consecutive Capacities
B0041usable with caveatsfirst Capacity 0.05562 Ah vs 2 Ah rated; 42 discharge(s) with Capacity below 0.5 Ah; 42 charge(s) above 4.22 V; charge current 1.2485502208928074 A vs 1.5 A; 11 discharge(s) go more than 0.15 V below the 2.0 V cut-off; 114 NaN values in time, voltage or current; 5 step(s) over 5 % between consecutive Capacities; the first 42 discharges are at 4 A and 4 C: NASA's Capacity (to 2.7 V) is 0.04-0.05 Ah and the whole discharge under 0.1 Ah, so the cell hardly discharges; from cycle 43 at 1 A it gives 0.8-1.2 Ah
B0042usable with caveatsfirst Capacity 1.72871 Ah vs 2 Ah rated; 47 discharge(s) with Capacity below 0.5 Ah; 7 charge(s) above 4.22 V; 1 discharge(s) stop more than 0.1 V above the 2.2 V cut-off; 11 discharge(s) go more than 0.15 V below the 2.2 V cut-off; ambient field [4.0, 22.0] vs README [4]; 118 NaN values in time, voltage or current; 23 step(s) over 5 % between consecutive Capacities; cycles 1-41 discharge at 2 A with the ambient field at 22 C (the README states 4 C and loads of 4 A and 1 A); cycles 42-87 at 4 A give a Capacity (to 2.7 V) of 0.06-0.10 Ah although about 0.7 Ah is discharged to 2.2 V; cycle 6 has Capacity 0
B0043usable with caveatsfirst Capacity 1.71378 Ah vs 2 Ah rated; 47 discharge(s) with Capacity below 0.5 Ah; 47 charge(s) above 4.22 V; 1 discharge(s) stop more than 0.1 V above the 2.5 V cut-off; 7 discharge(s) go more than 0.15 V below the 2.5 V cut-off; ambient field [4.0, 22.0] vs README [4]; 118 NaN values in time, voltage or current; 19 step(s) over 5 % between consecutive Capacities; as B0042 (2 A at 22 C in cycles 1-41, near-zero Capacity in the 4 A cycles, cycle 6 Capacity 0)
B0044usable with caveatsfirst Capacity 1.68653 Ah vs 2 Ah rated; 47 discharge(s) with Capacity below 0.5 Ah; 47 charge(s) above 4.22 V; 1 discharge(s) stop more than 0.1 V above the 2.7 V cut-off; 21 discharge(s) go more than 0.15 V below the 2.7 V cut-off; ambient field [4.0, 22.0] vs README [4]; 118 NaN values in time, voltage or current; 25 step(s) over 5 % between consecutive Capacities; as B0042 (2 A at 22 C in cycles 1-41, near-zero Capacity in the 4 A cycles, cycle 6 Capacity 0)
B0045usable with caveatsfirst Capacity 1.08198 Ah vs 2 Ah rated; 2 discharge(s) with Capacity below 0.5 Ah; 50 charge(s) above 4.22 V; 2 discharge(s) stop more than 0.1 V above the 2.0 V cut-off; 4 step(s) over 5 % between consecutive Capacities
B0046usable with caveatsfirst Capacity 1.72824 Ah vs 2 Ah rated; 3 discharge(s) with Capacity below 0.5 Ah; 3 discharge(s) stop more than 0.1 V above the 2.2 V cut-off; 4 step(s) over 5 % between consecutive Capacities
B0047usable with caveatsfirst Capacity 1.6743 Ah vs 2 Ah rated; 3 discharge(s) with Capacity below 0.5 Ah; 1 charge(s) above 4.22 V; 3 discharge(s) stop more than 0.1 V above the 2.5 V cut-off; 5 step(s) over 5 % between consecutive Capacities
B0048usable with caveatsfirst Capacity 1.658 Ah vs 2 Ah rated; 3 discharge(s) with Capacity below 0.5 Ah; 3 discharge(s) stop more than 0.1 V above the 2.7 V cut-off; 5 step(s) over 5 % between consecutive Capacities
B0049usable with caveatsfirst Capacity 0.85837 Ah vs 2 Ah rated; 1 discharge(s) with Capacity below 0.5 Ah; 1 charge(s) above 4.22 V; 1 discharge(s) stop more than 0.1 V above the 2.0 V cut-off; 2 NaN values in time, voltage or current; 7 step(s) over 5 % between consecutive Capacities; cycle 5 gives 2.38 Ah (above the 2 Ah rating) after a 0.69 Ah charge, which cannot be; cycle 17 Capacity 0; the README says the test ended when the control software crashed
B0050not usableCapacity jumps between 0.03 and 2.64 Ah from cycle to cycle; cycle 6 discharges 3.04 Ah after a 0.00015 Ah charge, which cannot be; charges reach 4.98 V; 4 discharges have no Capacity; the test ended when the control software crashed (README). Kept as recorded. Other findings: first Capacity 0.86314 Ah vs 2 Ah rated; 7 discharge(s) with Capacity below 0.5 Ah; 4 discharge(s) without a Capacity value; 13 charge(s) above 4.22 V; 1 discharge(s) stop more than 0.1 V above the 2.2 V cut-off; 8 discharge(s) go more than 0.15 V below the 2.2 V cut-off; 2 NaN values in time, voltage or current; 13 step(s) over 5 % between consecutive Capacities
B0051usable with caveatsfirst Capacity 0.64347 Ah vs 2 Ah rated; 1 discharge(s) with Capacity below 0.5 Ah; 1 charge(s) above 4.22 V; 1 discharge(s) stop more than 0.1 V above the 2.5 V cut-off; 2 NaN values in time, voltage or current; 7 step(s) over 5 % between consecutive Capacities; cycle 5 gives 2.33 Ah after a short charge, which cannot be; cycle 17 Capacity 0; test ended by a software crash (README)
B0052not usableAfter cycle 4 the charges carry about 5 mA while the voltage jumps between 0.3 V and 4.98 V, and 21 of 25 discharges have no Capacity: the cell was not measured properly; the test ended when the control software crashed (README). Kept as recorded. Other findings: first Capacity 0.86066 Ah vs 2 Ah rated; 21 discharge(s) without a Capacity value; 21 charge(s) above 4.22 V; charge current 0.009551293759144994 A vs 1.5 A; 21 discharge(s) go more than 0.15 V below the 2.7 V cut-off; 2 NaN values in time, voltage or current; 1 step(s) over 5 % between consecutive Capacities
B0053usable with caveatsfirst Capacity 1.06914 Ah vs 2 Ah rated; 1 discharge(s) with Capacity below 0.5 Ah; 1 discharge(s) stop more than 0.1 V above the 2.0 V cut-off; 7 step(s) over 5 % between consecutive Capacities; the last discharge has Capacity 0
B0054usable with caveatsfirst Capacity 0.73994 Ah vs 2 Ah rated; 1 discharge(s) with Capacity below 0.5 Ah; 1 discharge(s) stop more than 0.1 V above the 2.2 V cut-off; 7 step(s) over 5 % between consecutive Capacities; the last discharge has Capacity 0
B0055usable with caveatsfirst Capacity 0.799 Ah vs 2 Ah rated; 3 step(s) over 5 % between consecutive Capacities
B0056usable with caveatsfirst Capacity 0.78528 Ah vs 2 Ah rated; 7 step(s) over 5 % between consecutive Capacities

Before comparing cells

Licence and how to cite

NASA Ames Research Center, Prognostics Center of Excellence states no licence. NASA Ames publishes the data openly on its PCoE Data Set Repository and asks that it be cited, but states no licence on its record (data.nasa.gov: 'License not specified'), so the raw files are not redistributed here. What is published are per-cycle values Lemonergy computed from them (facts about each cycle), with the citation NASA asks for. Published by Lemonergy's own decision of 12 November 2026, on the same basis as CALCE; withdrawn if NASA asks. Fetch the files themselves from the publisher.

Cite: B. Saha and K. Goebel (2007). "Battery Data Set", NASA Prognostics Data Repository, NASA Ames Research Center, Moffett Field, CA

Credit: Data: B. Saha and K. Goebel (2007), "Battery Data Set", NASA Prognostics Data Repository, NASA Ames Research Center, Moffett Field, CA (cited as NASA asks). Per-cycle values computed by Lemonergy (battery-data).

Values pinned to battery-data revision e85dd43. The manifest names every source file by its SHA-256; the CSV’s own SHA-256 is 37247627956f15c0c74465c8fa92dfa29be38de8ee0d180d27687010e03fb4d6.