Open battery ageing data · NASA PCoE
NASA PCoE battery ageing data: 34 18650 cells, cycle by cycle
The NASA Ames Prognostics Center of Excellence (Saha and Goebel, 2007) charged and discharged 34 Li-ion 18650 cells of 2 Ah rating in nine groups, at ambient temperatures from 4 to 44 °C, loads of 1 to 4 A and cut-off voltages from 2.0 to 2.7 V. NASA names no maker, no model and no chemistry. Lemonergy computed one row per charge-discharge cycle from the published files, with NASA’s own capacity beside it. NASA states no licence, so its files are not copied here; the computed values are, with the citation NASA asks for.
Download every cycle (CSV, 335 kB)Manifest (JSON): files, hashes, unitsChart and Excel downloadOriginal dataset
Free to download, no account needed. Or read it straight into Python:
import pandas as pd
cycles = pd.read_csv("https://lemonergy.com/data/ageing/nasa-pcoe/cycles.csv")- Cells
- 34 cells, 18650 (data.nasa.gov record: 'Commercially available Li-ion 18650 sized rechargeable batteries'); maker not stated
- Chemistry
- Li-ion, not further stated
- Nominal capacity
- 2 Ah
- Cycles
- 2,825, one row each
- Test programmes
- 9
- Published by
- NASA Ames Research Center, Prognostics Center of Excellence
- Licence
- None stated: computed values only, published with the citation the publisher asks for; the files are not copied
- Files retrieved
- 2026-11-12
Source: NASA Ames PCoE Battery Data Set (Saha and Goebel): 34 Li-ion 18650 cells, charge, discharge and EIS, NASA Ames Research Center, Prognostics Center of Excellence. No licence stated: the values below are computed from its files, which are not copied here.
Cite: B. Saha and K. Goebel (2007). "Battery Data Set", NASA Prognostics Data Repository, NASA Ames Research Center, Moffett Field, CA
Licence and how to cite · Data quality · Every source file, by SHA-256
Capacity fade, cycle by cycle
NASA’s own capacity of each discharge, one coloured line per cell, or per cell and load where its load or temperature changes. One discharge rate per line. Point at a chart to read the values; download them as Excel.
The chart needs JavaScript; every cell’s values are in the table below and in the CSV.
Point at or touch a chart to read every cell’s value at that cycle. Drag across it with a mouse to zoom in. Click a line, or a cell’s name in the legend or table, to show that cell on its own; the others turn grey.Touch a chart to read the values at a cycle. Tap a cell’s name in the legend or the table to show it on its own; the others turn grey.
| Cell | Cycles run | Points drawn | First (Ah) | Last (Ah) | Last / first |
|---|
Every cell
First and last discharge capacity of the cycles the chart draws, for all 50 lines and cells. Every row of every cell, with all its values, is in the CSV (335 kB).
| Programme | Cell | Cycles run | Points drawn | First (Ah) | Last (Ah) | Last / first |
|---|---|---|---|---|---|---|
| FY08Q4 | B0005 | 169 | 168 | 1.857 | 1.325 | 71.4 % |
| FY08Q4 | B0006 | 169 | 168 | 2.035 | 1.186 | 58.3 % |
| FY08Q4 | B0007 | 169 | 168 | 1.891 | 1.433 | 75.8 % |
| FY08Q4 | B0018 | 132 | 132 | 1.855 | 1.341 | 72.3 % |
| 25-28 | B0025 | 29 | 28 | 1.847 | 1.768 | 95.7 % |
| 25-28 | B0026 | 29 | 28 | 1.813 | 1.769 | 97.5 % |
| 25-28 | B0027 | 29 | 28 | 1.823 | 1.770 | 97.1 % |
| 25-28 | B0028 | 29 | 28 | 1.805 | 1.717 | 95.2 % |
| 29-32 | B0029 | 41 | 40 | 1.698 | 1.612 | 95.0 % |
| 29-32 | B0030 | 41 | 40 | 1.656 | 1.563 | 94.4 % |
| 29-32 | B0031 | 41 | 40 | 1.667 | 1.667 | 100.0 % |
| 29-32 | B0032 | 41 | 40 | 1.705 | 1.636 | 95.9 % |
| 33-36 | B0033 | 198 | 197 | 0.068 | 1.315 | 1923.0 % |
| 33-36 | B0034 | 198 | 197 | 0.746 | 1.280 | 171.6 % |
| 33-36 | B0036 | 198 | 197 | 1.002 | 1.559 | 155.6 % |
| 38-40 | B0038 at 4 A, 24 C | 48 | 12 | 0.898 | 1.008 | 112.3 % |
| 38-40 | B0038 at 1 A, 44 C | 48 | 26 | 1.780 | 1.775 | 99.7 % |
| 38-40 | B0038 at 2 A, 44 C | 48 | 6 | 1.733 | 1.729 | 99.7 % |
| 38-40 | B0038 at 4 A, 44 C | 48 | 2 | 1.526 | 1.530 | 100.3 % |
| 38-40 | B0039 at 4 A, 24 C | 48 | 12 | 0.119 | 0.413 | 346.8 % |
| 38-40 | B0039 at 1 A, 44 C | 48 | 26 | 1.770 | 1.743 | 98.5 % |
| 38-40 | B0039 at 2 A, 44 C | 48 | 6 | 1.656 | 1.611 | 97.3 % |
| 38-40 | B0039 at 4 A, 44 C | 48 | 2 | 1.324 | 1.315 | 99.3 % |
| 38-40 | B0040 at 4 A, 24 C | 48 | 12 | 0.673 | 0.715 | 106.2 % |
| 38-40 | B0040 at 1 A, 44 C | 48 | 26 | 1.731 | 1.725 | 99.7 % |
| 38-40 | B0040 at 2 A, 44 C | 48 | 6 | 1.667 | 1.642 | 98.5 % |
| 38-40 | B0040 at 4 A, 44 C | 48 | 2 | 0.426 | 0.557 | 130.8 % |
| 41-44 | B0041 at 4 A, 4 C | 68 | 42 | 0.056 | 0.048 | 86.9 % |
| 41-44 | B0041 at 1 A, 4 C | 68 | 25 | 1.216 | 0.837 | 68.8 % |
| 41-44 | B0042 at 2 A, 22 C | 113 | 41 | 1.729 | 1.566 | 90.6 % |
| 41-44 | B0042 at 4 A, 4 C | 113 | 45 | 0.084 | 0.063 | 74.3 % |
| 41-44 | B0042 at 1 A, 4 C | 113 | 25 | 1.438 | 1.337 | 93.0 % |
| 41-44 | B0043 at 2 A, 22 C | 113 | 41 | 1.714 | 1.470 | 85.7 % |
| 41-44 | B0043 at 4 A, 4 C | 113 | 45 | 0.057 | 0.062 | 108.2 % |
| 41-44 | B0043 at 1 A, 4 C | 113 | 25 | 1.525 | 1.277 | 83.7 % |
| 41-44 | B0044 at 2 A, 22 C | 113 | 41 | 1.687 | 1.415 | 83.9 % |
| 41-44 | B0044 at 4 A, 4 C | 113 | 45 | 0.057 | 0.062 | 108.0 % |
| 41-44 | B0044 at 1 A, 4 C | 113 | 25 | 1.478 | 1.249 | 84.5 % |
| 45-48 | B0045 | 73 | 72 | 1.082 | 0.607 | 56.1 % |
| 45-48 | B0046 | 73 | 72 | 1.728 | 1.154 | 66.8 % |
| 45-48 | B0047 | 73 | 72 | 1.674 | 1.157 | 69.1 % |
| 45-48 | B0048 | 73 | 72 | 1.658 | 1.223 | 73.8 % |
| 49-52 | B0049 | 26 | 25 | 0.858 | 0.691 | 80.5 % |
| 49-52 | B0051 | 26 | 25 | 0.643 | 0.678 | 105.3 % |
| 53-56 | B0053 | 56 | 56 | 1.069 | 0.000 | 0.0 % |
| 53-56 | B0054 | 103 | 103 | 0.740 | 0.000 | 0.0 % |
| 53-56 | B0055 | 103 | 102 | 0.799 | 0.991 | 124.0 % |
| 53-56 | B0056 | 103 | 102 | 0.785 | 1.129 | 143.8 % |
| 49-52 | B0050 | 26 | not drawn | – | – | – |
| 49-52 | B0052 | 26 | not drawn | – | – | – |
Not drawn: B0050, the manifest's quality check calls it not usable: Capacity jumps between 0.03 and 2.64 Ah from cycle to cycle; cycle 6 discharges 3.04 Ah after a 0.00015 Ah charge, which cannot be; charges reach 4.98 V; 4 discharges have no Capacity; the test ended when the control software crashed (README); B0052, the manifest's quality check calls it not usable: After cycle 4 the charges carry about 5 mA while the voltage jumps between 0.3 V and 4.98 V, and 21 of 25 discharges have no Capacity: the cell was not measured properly; the test ended when the control software crashed (README). Their rows are in the CSV.
Test programmes
- FY08Q4. B0005, B0006, B0007, B0018 (README.txt of 1. BatteryAgingARC-FY08Q4): room temperature; charge 1.5 A CC to 4.2 V, CV until 20 mA; discharge 2 A CC to 2.7, 2.5, 2.2 and 2.5 V for 5, 6, 7 and 18; EIS 0.1 Hz to 5 kHz; stopped at 30 % fade in rated capacity (2 Ah to 1.4 Ah). Drawn: NASA's Capacity of each discharge, one line per load and ambient temperature.
- 25-28. B0025-B0028 (README_25_26_27_28.txt): room temperature (24 C); charge 1.5 A CC to 4.2 V, CV until 20 mA; discharge as a 0.05 Hz square wave of 4 A amplitude and 50 % duty cycle to 2.0, 2.2, 2.5 and 2.7 V for 25, 26, 27 and 28; EIS 0.1 Hz to 5 kHz; no end criterion stated. Drawn: NASA's Capacity of each discharge, one line per load and ambient temperature.
- 29-32. B0029-B0032 (README_29_30_31_32.txt): elevated ambient temperature (43 C); charge as above; discharge at 4 A to 2.0, 2.2, 2.5 and 2.7 V for 29, 30, 31 and 32; no end criterion stated. Drawn: NASA's Capacity of each discharge, one line per load and ambient temperature.
- 33-36. B0033, B0034, B0036 (README_33_34_36.txt): room temperature (24 C); charge as above; discharge at 4 A to 2.0 and 2.2 V for 33 and 34; B0036 at 2 A to 2.7 V; stopped at 1.6 Ah (20 % fade). Drawn: NASA's Capacity of each discharge, one line per load and ambient temperature.
- 38-40. B0038-B0040 (README_38_39_40.txt): multiple ambient temperatures (24 and 44 C); charge as above; multiple load currents (1, 2 and 4 A); discharge stopped at 2.2, 2.5 and 2.7 V for 38, 39 and 40; stopped at 1.6 Ah (20 % fade). Drawn: NASA's Capacity of each discharge, one line per load and ambient temperature.
- 41-44. B0041-B0044 (README_41_42_43_44.txt): ambient 4 C; charge as above; fixed load currents of 4 A and 1 A; discharge stopped at 2.0, 2.2, 2.5 and 2.7 V for 41, 42, 43 and 44; stopped at 1.4 Ah (30 % fade); 'several discharge runs where the capacity was very low. Reasons for this have not been fully analyzed.'. Drawn: NASA's Capacity of each discharge, one line per load and ambient temperature.
- 45-48. B0045-B0048 (README_45_46_47_48.txt): ambient 4 C; charge as above; fixed load of 1 A; discharge stopped at 2.0, 2.2, 2.5 and 2.7 V for 45, 46, 47 and 48; stopped at 1.4 Ah (30 % fade); the same note on very low capacities. Drawn: NASA's Capacity of each discharge, one line per load and ambient temperature.
- 49-52. B0049-B0052 (README_49_50_51_52.txt): ambient 4 C; charge as above; fixed load of 2 A; discharge stopped at 2.0, 2.2, 2.5 and 2.7 V for 49, 50, 51 and 52; 'carried out until the experiment control software crashed'; 'several discharge runs where the capacity as well as voltage levels were very low'. Drawn: NASA's Capacity of each discharge, one line per load and ambient temperature.
- 53-56. B0053-B0056 (README_53_54_55_56.txt): ambient 4 C; charge as above; fixed load of 2 A; discharge stopped at 2.0, 2.2, 2.5 and 2.7 V for 53, 54, 55 and 56; stopped at 1.4 Ah (30 % fade); the same note on very low capacities. Drawn: NASA's Capacity of each discharge, one line per load and ambient temperature.
Columns of the CSV
Each .mat file read from the zip with battery-data tools/convert_nasa_pcoe.py (scipy.io.loadmat; nothing is extracted to disk). The charge and discharge operations are put on one time axis (operation start minus first operation start, plus Time); impedance operations are left out. A cycle is NASA's own: the charge operation(s) since the previous discharge, then one discharge operation; it is passed to tools/dataset_cycles.py as the file's cycle key, and each row is computed with the cycle summary of tools/cyclers.py (current sign read from the operation types: charge positive; capacity integrated from Current_measured with cyclers' step_aware_min rule (docs/36), with the operation as the step: the trapezoid between two samples of one operation, as NASA computes its Capacity, and across two operations the smaller of the two currents (nothing where they differ in sign); nothing integrated across a gap longer than max(20 median intervals, 1 h)). The label names the operations by their 1-based index in the file, the mean discharge current and the ambient temperature. discharge_ah_reported is NASA's Capacity of the discharge operation. B0025-B0028 are in two inner zips, byte for byte the same; each is filed once (also_at). Values are rounded as printed: Ah to 5 decimals, efficiency and volts to 4, seconds to 0.1.
| Column | Unit | Meaning |
|---|---|---|
batch | – | README group of the cell (see batches) |
cell | – | cell file name without .mat (B00##) |
cycle | – | cycle number, 1-based: NASA's charge operation(s) then one discharge operation |
label | – | the file's operations in the cycle (1-based index), mean discharge current, ambient temperature |
charge_ah | Ah | charge integrated from Current_measured over the charge operation(s) |
discharge_ah | Ah | discharge integrated from Current_measured over the whole discharge operation |
charge_ah_reported | Ah | blank: NASA reports no charge figure |
discharge_ah_reported | Ah | NASA's Capacity of the discharge operation (discharged until the voltage first falls below 2.7 V) |
coulombic_efficiency | – | discharge_ah / charge_ah (blank when charge_ah is zero) |
v_max | V | highest Voltage_measured in the cycle |
v_min | V | lowest Voltage_measured in the cycle |
duration_s | s | length of the cycle on the joined time axis, unlogged time between operations included |
start_test_time_s | s | start of the cycle, seconds after the cell's first operation |
Data quality
Overall: Of 34 cells, 32 are usable with caveats and 2 are not usable (B0050, B0052); no cell is free of findings. The classic cells B0005, B0006, B0007 and B0018 hold no implausible capacity; their findings are charge-start spikes, discharges whose voltage dips more than 0.15 V below the cut-off and the known capacity jumps after pauses. The 4 C groups (B0041-B0056) hold many irregular runs, as their READMEs warn.
34 cells checked: 0 usable, 32 usable with caveats, 2 not usable.
| Cell | Verdict | Why |
|---|---|---|
| B0005 | usable with caveats | 2 charge(s) above 4.22 V; 12 discharge(s) go more than 0.15 V below the 2.7 V cut-off; 1 step(s) over 5 % between consecutive Capacities; the charge record of some cycles opens with a voltage spike (up to 8.39 V) and a -4 A sample, at the start of charge |
| B0006 | usable with caveats | 2 charge(s) above 4.22 V; 19 discharge(s) go more than 0.15 V below the 2.5 V cut-off; 3 step(s) over 5 % between consecutive Capacities; charge spikes as B0005 (up to 8.08 V) |
| B0007 | usable with caveats | 2 charge(s) above 4.22 V; 56 discharge(s) go more than 0.15 V below the 2.2 V cut-off; 1 step(s) over 5 % between consecutive Capacities; Capacity (above 0.5 Ah) never falls to the stated end criterion 1.4 Ah (lowest 1.40046 Ah, last 1.43246 Ah); charge spikes as B0005 (up to 8.33 V) |
| B0018 | usable with caveats | 2 charge(s) above 4.22 V; 19 discharge(s) go more than 0.15 V below the 2.5 V cut-off; 4 NaN values in time, voltage or current; 3 step(s) over 5 % between consecutive Capacities |
| B0025 | usable with caveats | 15 discharge(s) go more than 0.15 V below the 2.0 V cut-off; 4 NaN values in time, voltage or current |
| B0026 | usable with caveats | 20 discharge(s) go more than 0.15 V below the 2.2 V cut-off; 4 NaN values in time, voltage or current; 5 step(s) over 5 % between consecutive Capacities |
| B0027 | usable with caveats | 4 NaN values in time, voltage or current |
| B0028 | usable with caveats | 4 discharge(s) go more than 0.15 V below the 2.7 V cut-off; 4 NaN values in time, voltage or current; discharges as a square wave of 2 A amplitude; the README says 4 A for B0025-B0028 |
| B0029 | usable with caveats | first Capacity 1.69751 Ah vs 2 Ah rated; 8 discharge(s) go more than 0.15 V below the 2.0 V cut-off; 1 step(s) over 5 % between consecutive Capacities |
| B0030 | usable with caveats | first Capacity 1.65607 Ah vs 2 Ah rated; 9 discharge(s) go more than 0.15 V below the 2.2 V cut-off; 1 step(s) over 5 % between consecutive Capacities |
| B0031 | usable with caveats | first Capacity 1.66668 Ah vs 2 Ah rated; 10 discharge(s) go more than 0.15 V below the 2.5 V cut-off; 1 step(s) over 5 % between consecutive Capacities |
| B0032 | usable with caveats | first Capacity 1.70486 Ah vs 2 Ah rated; 1 step(s) over 5 % between consecutive Capacities |
| B0033 | usable with caveats | first Capacity 0.06843 Ah vs 2 Ah rated; 9 discharge(s) with Capacity below 0.5 Ah; 8 charge(s) above 4.22 V; 63 discharge(s) go more than 0.15 V below the 2.0 V cut-off; 4 NaN values in time, voltage or current; 22 step(s) over 5 % between consecutive Capacities; first two discharges 0.07 and 0.68 Ah; capacities 0.2-0.84 Ah in cycles 139-147 between normal values; jumps up to +30 % after pauses |
| B0034 | usable with caveats | first Capacity 0.74593 Ah vs 2 Ah rated; 48 discharge(s) go more than 0.15 V below the 2.2 V cut-off; 4 NaN values in time, voltage or current; 14 step(s) over 5 % between consecutive Capacities |
| B0036 | usable with caveats | first Capacity 1.00198 Ah vs 2 Ah rated; 4 NaN values in time, voltage or current; 5 step(s) over 5 % between consecutive Capacities |
| B0038 | usable with caveats | first Capacity 0.89806 Ah vs 2 Ah rated; 3 discharge(s) go more than 0.15 V below the 2.2 V cut-off; 2 NaN values in time, voltage or current; 4 step(s) over 5 % between consecutive Capacities |
| B0039 | usable with caveats | first Capacity 0.11904 Ah vs 2 Ah rated; 12 discharge(s) with Capacity below 0.5 Ah; 2 NaN values in time, voltage or current; 7 step(s) over 5 % between consecutive Capacities; the first 12 discharges at 4 A give 0.11-0.47 Ah, then about 1.75 Ah at 1 A |
| B0040 | usable with caveats | first Capacity 0.67346 Ah vs 2 Ah rated; 1 discharge(s) with Capacity below 0.5 Ah; 2 discharge(s) go more than 0.15 V below the 2.7 V cut-off; 2 NaN values in time, voltage or current; 5 step(s) over 5 % between consecutive Capacities |
| B0041 | usable with caveats | first Capacity 0.05562 Ah vs 2 Ah rated; 42 discharge(s) with Capacity below 0.5 Ah; 42 charge(s) above 4.22 V; charge current 1.2485502208928074 A vs 1.5 A; 11 discharge(s) go more than 0.15 V below the 2.0 V cut-off; 114 NaN values in time, voltage or current; 5 step(s) over 5 % between consecutive Capacities; the first 42 discharges are at 4 A and 4 C: NASA's Capacity (to 2.7 V) is 0.04-0.05 Ah and the whole discharge under 0.1 Ah, so the cell hardly discharges; from cycle 43 at 1 A it gives 0.8-1.2 Ah |
| B0042 | usable with caveats | first Capacity 1.72871 Ah vs 2 Ah rated; 47 discharge(s) with Capacity below 0.5 Ah; 7 charge(s) above 4.22 V; 1 discharge(s) stop more than 0.1 V above the 2.2 V cut-off; 11 discharge(s) go more than 0.15 V below the 2.2 V cut-off; ambient field [4.0, 22.0] vs README [4]; 118 NaN values in time, voltage or current; 23 step(s) over 5 % between consecutive Capacities; cycles 1-41 discharge at 2 A with the ambient field at 22 C (the README states 4 C and loads of 4 A and 1 A); cycles 42-87 at 4 A give a Capacity (to 2.7 V) of 0.06-0.10 Ah although about 0.7 Ah is discharged to 2.2 V; cycle 6 has Capacity 0 |
| B0043 | usable with caveats | first Capacity 1.71378 Ah vs 2 Ah rated; 47 discharge(s) with Capacity below 0.5 Ah; 47 charge(s) above 4.22 V; 1 discharge(s) stop more than 0.1 V above the 2.5 V cut-off; 7 discharge(s) go more than 0.15 V below the 2.5 V cut-off; ambient field [4.0, 22.0] vs README [4]; 118 NaN values in time, voltage or current; 19 step(s) over 5 % between consecutive Capacities; as B0042 (2 A at 22 C in cycles 1-41, near-zero Capacity in the 4 A cycles, cycle 6 Capacity 0) |
| B0044 | usable with caveats | first Capacity 1.68653 Ah vs 2 Ah rated; 47 discharge(s) with Capacity below 0.5 Ah; 47 charge(s) above 4.22 V; 1 discharge(s) stop more than 0.1 V above the 2.7 V cut-off; 21 discharge(s) go more than 0.15 V below the 2.7 V cut-off; ambient field [4.0, 22.0] vs README [4]; 118 NaN values in time, voltage or current; 25 step(s) over 5 % between consecutive Capacities; as B0042 (2 A at 22 C in cycles 1-41, near-zero Capacity in the 4 A cycles, cycle 6 Capacity 0) |
| B0045 | usable with caveats | first Capacity 1.08198 Ah vs 2 Ah rated; 2 discharge(s) with Capacity below 0.5 Ah; 50 charge(s) above 4.22 V; 2 discharge(s) stop more than 0.1 V above the 2.0 V cut-off; 4 step(s) over 5 % between consecutive Capacities |
| B0046 | usable with caveats | first Capacity 1.72824 Ah vs 2 Ah rated; 3 discharge(s) with Capacity below 0.5 Ah; 3 discharge(s) stop more than 0.1 V above the 2.2 V cut-off; 4 step(s) over 5 % between consecutive Capacities |
| B0047 | usable with caveats | first Capacity 1.6743 Ah vs 2 Ah rated; 3 discharge(s) with Capacity below 0.5 Ah; 1 charge(s) above 4.22 V; 3 discharge(s) stop more than 0.1 V above the 2.5 V cut-off; 5 step(s) over 5 % between consecutive Capacities |
| B0048 | usable with caveats | first Capacity 1.658 Ah vs 2 Ah rated; 3 discharge(s) with Capacity below 0.5 Ah; 3 discharge(s) stop more than 0.1 V above the 2.7 V cut-off; 5 step(s) over 5 % between consecutive Capacities |
| B0049 | usable with caveats | first Capacity 0.85837 Ah vs 2 Ah rated; 1 discharge(s) with Capacity below 0.5 Ah; 1 charge(s) above 4.22 V; 1 discharge(s) stop more than 0.1 V above the 2.0 V cut-off; 2 NaN values in time, voltage or current; 7 step(s) over 5 % between consecutive Capacities; cycle 5 gives 2.38 Ah (above the 2 Ah rating) after a 0.69 Ah charge, which cannot be; cycle 17 Capacity 0; the README says the test ended when the control software crashed |
| B0050 | not usable | Capacity jumps between 0.03 and 2.64 Ah from cycle to cycle; cycle 6 discharges 3.04 Ah after a 0.00015 Ah charge, which cannot be; charges reach 4.98 V; 4 discharges have no Capacity; the test ended when the control software crashed (README). Kept as recorded. Other findings: first Capacity 0.86314 Ah vs 2 Ah rated; 7 discharge(s) with Capacity below 0.5 Ah; 4 discharge(s) without a Capacity value; 13 charge(s) above 4.22 V; 1 discharge(s) stop more than 0.1 V above the 2.2 V cut-off; 8 discharge(s) go more than 0.15 V below the 2.2 V cut-off; 2 NaN values in time, voltage or current; 13 step(s) over 5 % between consecutive Capacities |
| B0051 | usable with caveats | first Capacity 0.64347 Ah vs 2 Ah rated; 1 discharge(s) with Capacity below 0.5 Ah; 1 charge(s) above 4.22 V; 1 discharge(s) stop more than 0.1 V above the 2.5 V cut-off; 2 NaN values in time, voltage or current; 7 step(s) over 5 % between consecutive Capacities; cycle 5 gives 2.33 Ah after a short charge, which cannot be; cycle 17 Capacity 0; test ended by a software crash (README) |
| B0052 | not usable | After cycle 4 the charges carry about 5 mA while the voltage jumps between 0.3 V and 4.98 V, and 21 of 25 discharges have no Capacity: the cell was not measured properly; the test ended when the control software crashed (README). Kept as recorded. Other findings: first Capacity 0.86066 Ah vs 2 Ah rated; 21 discharge(s) without a Capacity value; 21 charge(s) above 4.22 V; charge current 0.009551293759144994 A vs 1.5 A; 21 discharge(s) go more than 0.15 V below the 2.7 V cut-off; 2 NaN values in time, voltage or current; 1 step(s) over 5 % between consecutive Capacities |
| B0053 | usable with caveats | first Capacity 1.06914 Ah vs 2 Ah rated; 1 discharge(s) with Capacity below 0.5 Ah; 1 discharge(s) stop more than 0.1 V above the 2.0 V cut-off; 7 step(s) over 5 % between consecutive Capacities; the last discharge has Capacity 0 |
| B0054 | usable with caveats | first Capacity 0.73994 Ah vs 2 Ah rated; 1 discharge(s) with Capacity below 0.5 Ah; 1 discharge(s) stop more than 0.1 V above the 2.2 V cut-off; 7 step(s) over 5 % between consecutive Capacities; the last discharge has Capacity 0 |
| B0055 | usable with caveats | first Capacity 0.799 Ah vs 2 Ah rated; 3 step(s) over 5 % between consecutive Capacities |
| B0056 | usable with caveats | first Capacity 0.78528 Ah vs 2 Ah rated; 7 step(s) over 5 % between consecutive Capacities |
Before comparing cells
- NASA's Capacity (discharge_ah_reported) is the charge discharged until the voltage first falls below 2.7 V, as the README says ('for discharge till 2.7V'): it equals the trapezoid integral of Current_measured up to that sample to within 0.01 mAh in every discharge. Cells cut off at 2.5, 2.2 or 2.0 V discharge more than that, which discharge_ah includes. Under a 4 A load in the cold (B0041-B0044) the voltage falls below 2.7 V almost at once, so Capacity is near zero although the cell goes on discharging; this explains most of the 'very low capacity' runs the READMEs mention.
- Quality gate: NASA's Capacity against the published rule over the same stretch (the discharge operation to the first sample below 2.7 V) differs by a median 0.000 mAh (95th percentile 0.002 mAh, max 0.034 mAh, 2714 discharges, all within 1 mAh). The values were regenerated on 17 November 2026 with cyclers' step_aware_min rule (docs/36), which inside an operation is the trapezoid NASA uses. First published with the right-rectangle rule, they differed by a median 3.387 mAh (95th percentile 8.19 mAh, max 9.137 mAh): at 17-19 s logging the first loaded sample of each discharge was credited with the whole interval before it, where NASA takes half.
- Every discharge is a full discharge to the cell's cut-off voltage at the stated load, so every row with a Capacity is a capacity measurement at that cell's condition. Capacities at different cut-offs, loads or temperatures are not comparable with each other; batches and the label say which is which.
- The time between operations is not logged (rests and EIS sweeps sit there). Where such a gap inside a cycle is under an hour, it is integrated at the smaller of the two currents on either side of it (the end of one operation and the start of the next), nothing where they differ in sign; the largest effect in any cycle is 4.5 mAh (max_gap_credit_mah per cell). With the right-rectangle rule first published it was the first sample's current over the whole gap, up to 7.6 mAh.
- Cycles with two charge records before one discharge (B0005-B0007 cycles 12 and 31, B0018 cycles 46 and 56, B0025-B0028 cycles 8 and 23) hold both charges; their charge_ah and coulombic efficiency are not a normal cycle's (see exceptions).
- Most cells end with a charge after the last discharge, a last row with no discharge (cycles_without_discharge per cell).
- Odd records kept as recorded and judged per cell under quality.cells: B0050 and B0052 are not usable; capacities above the 2 Ah rating after a short charge (B0049, B0051 cycle 5); Capacity 0 (B0042-B0044 cycle 6, B0045-B0048 several, B0049-B0051 cycle 17, last cycle of B0053 and B0054); charge-start voltage spikes up to 8.4 V (B0005-B0007); NaN samples (up to 118 per cell, B0041-B0044); jumps of more than 5 % between consecutive capacities after pauses (the known 'regeneration' of this data).
- Differences from the READMEs: the discharge records name their fields Current_load and Voltage_load, not Current_charge and Voltage_charge; B0028 discharges as a 2 A square wave, not 4 A; in B0041 some 4 A runs average 3.3-3.9 A; B0042-B0044 discharge at 2 A with the ambient_temperature field at 22 C in cycles 1-41 (and 4/22 C in cycle 42), where the README states 4 C and loads of 4 A and 1 A; the FY08Q4 README says 'room temperature' and the files say 24 C.
- Not stated by NASA, so not filed: maker, model, chemistry, nominal voltage, and whether all 34 cells are one model.
- NASA's Capacity counts the charge discharged until the voltage first falls below 2.7 V, whatever the cell's own cut-off. Under a 4 A load, and in the cold at 4 C, the voltage falls below 2.7 V almost at once, so some values are near zero although the cell went on discharging. They are drawn as recorded. The chart draws NASA's Capacity, so its values did not change when the library recomputed its integrated columns on 17 November 2026. Over the same stretch, to the first sample below 2.7 V, the library's rule now gives NASA's Capacity to a median 0.000 mAh and at most 0.034 mAh (the first rule: a median 3.4 mAh); discharge_ah runs to the cell's own cut-off and differs from it by design. The manifest's per-cell coulombic efficiency now uses a stated selection of cycles (one charge, then a discharge with a Capacity above 0), which moved B0041 from 0.9965 to 1.024; no verdict changed.
Licence and how to cite
NASA Ames Research Center, Prognostics Center of Excellence states no licence. NASA Ames publishes the data openly on its PCoE Data Set Repository and asks that it be cited, but states no licence on its record (data.nasa.gov: 'License not specified'), so the raw files are not redistributed here. What is published are per-cycle values Lemonergy computed from them (facts about each cycle), with the citation NASA asks for. Published by Lemonergy's own decision of 12 November 2026, on the same basis as CALCE; withdrawn if NASA asks. Fetch the files themselves from the publisher.
Cite: B. Saha and K. Goebel (2007). "Battery Data Set", NASA Prognostics Data Repository, NASA Ames Research Center, Moffett Field, CA
Credit: Data: B. Saha and K. Goebel (2007), "Battery Data Set", NASA Prognostics Data Repository, NASA Ames Research Center, Moffett Field, CA (cited as NASA asks). Per-cycle values computed by Lemonergy (battery-data).
Values pinned to battery-data revision e85dd43. The manifest names every source file by its SHA-256; the CSV’s own SHA-256 is 37247627956f15c0c74465c8fa92dfa29be38de8ee0d180d27687010e03fb4d6.
Related
- XJTU battery ageing data: 55 Lishen 18650 cells, cycle by cycle
- CALCE CS2 battery ageing data: 15 LiCoO2 cells, cycle by cycle
- Tongji/KIT NCA ageing data: 66 18650 cells, cycle by cycle
- Tongji/KIT NCM ageing data: 55 18650 cells, cycle by cycle
- Tongji/KIT NCM+NCA ageing data: 9 18650 cells at three discharge rates
- Michigan VTC6 data: 194 characterisations of 70 aged 18650 cells
- CMU eVTOL battery data: 22 VTC6 cells under aircraft missions
- Oxford battery degradation data: 8 Kokam pouch cells, test by test
- UConn LFP ageing data: 64 18650 cells under 11 cycling conditions
- HYDRA ageing data: 32 LG MJ1 18650 cells under ship-like cycling
- REBELION ageing data: 160 Samsung 50E cells, four cycling strategies
- TEMPEST ageing data: a 280 Ah LFP cell over 700 cycles at 1C
- LiBforSecUse ageing data: 34 18650 NMC811 cells, 13 life-cycle tests
- VERSAPRINT cycle data: one Lishen 51 Ah cell, nine cycles
- EVERLASTING ageing data: 28 Samsung 35E cells under drive cycles
- FreeTwinEV module data: four Molicel P45B cells in parallel, 14 runs
- All open battery ageing data on Lemonergy
- How these datasets were imported and checked
- Find and compare battery cells