Battery knowledge · Charging and discharging
Battery charging strategies
Battery charging strategies define how a charger commands current, voltage or power and how it decides to change stages or stop. Chemistry, temperature, battery state and infrastructure also determine which strategies are applicable. [1] [2] [3]
Compare charging profiles
See which quantity is held constant, when the phase changes and how charging ends.
Current holds at 5 A until the example 4.15 V threshold; voltage then holds while current tapers. The stop marker is a separate low-current termination condition.
CC: I = I_set · CV: V = V_limit
Illustrative model. Positive current charges the cell. Time is normalized; selected thresholds are not cell-specific recommendations. The voltage trace ends at termination; post-stop relaxation is excluded.
Example
Worked example
Compare a current-limited session, a power-limited session and a stepped current schedule at the same starting state of charge. Look for phase transitions and record the achieved charge separately from the peak current.
Use in Lemonergy
Separate regulation from availability.
This is a reference concept. No executable Lemonergy block has been verified for this term.
References & further reading
Technical references
- Closed-loop optimization of fast-charging protocols for batteries with machine learning
Nature
Technical reference · Experimental selection of multistep lithium-ion charging profiles. Figure shape and settings here are independently authored.
- Insight into pulse-charging for lithium plating-free fast-charging lithium-ion batteries
Electrochimica Acta
Technical reference · Experimental and modeling study of pulse charging and lithium plating under the study conditions.
- Lithium-ion battery fast charging: A review
Anna Tomaszewska et al. · eTransportation · 2019
Technical reference · CC-CV and alternative charging protocols, transport limitations, degradation and thermal implications; results depend on cell and test conditions. Software behavior is documented separately in Lemonergy block references.
Browse by category
Basic electrical profiles
- Constant current
A charge or discharge at a fixed current, so capacity is simply current times time.
- Constant voltage
A charge stage in which the terminal voltage is held at a selected limit while the current is allowed to fall.
- CC-CV charging
The standard lithium-ion charge protocol: constant current until the cell reaches its upper cutoff voltage, then that voltage held constant while the current tapers.
- Constant-power charging
Constant-power charging regulates the product of terminal voltage and current.
- Constant power followed by constant voltage
Constant power followed by constant voltage is a two-stage charging profile.
- Multistage constant-current charging
A charge protocol with a sequence of constant-current stages, often reducing current as the cell fills.
- Multistage constant current with CV finish
A multistage current schedule uses several constant-current plateaus before a final constant-voltage stage.
- Ramped-current charging
A ramped charger increases or decreases its current command continuously over a time or state interval.
- Taper charging
Charging from a source whose current falls by itself as the battery voltage rises — classically a transformer and rectifier with no regulation.
Pulse and feedback profiles
- Pulse charging
Charging with current pulses separated by rests or short discharges, intended to let concentration gradients relax and reduce plating.
- Reverse-pulse charging
Reverse-pulse charging inserts brief discharge intervals into a net charging sequence.
- Adaptive charging
Charging whose current and voltage limits adjust in real time to what the battery can safely take — its temperature, state of charge, health or impedance — or to when it is needed.
- Model-predictive battery charging
Model-predictive charging estimates future battery behavior and chooses a current sequence subject to model and operating constraints.
- Non-linear voltammetry charging
Non-linear voltammetry charging uses a deliberately shaped potential trajectory or adaptively varies the voltage ramp while observing current.
Temperature and charging speed
- Temperature-conditioned charging
Temperature-conditioned charging changes cell temperature before allowing more current, or limits the request using measured temperature during charging.
- Preconditioning
Warming or cooling the battery to its preferred temperature before a fast charge or a hard drive, using the vehicle’s own heaters and pumps.
- AC slow charging
Charging through the vehicle’s onboard charger from an AC socket or wallbox, at a few kilowatts up to 22 kW.
- Fast charging
Charging intended to replenish a specified amount of energy or state of charge in a short time.
- Extreme fast charging
Charging a vehicle battery in about 10–15 minutes, roughly 4C to 6C — the US Department of Energy’s research target that set the term.
- DC fast charging
Charging from a station that supplies DC straight to the pack, bypassing the car’s onboard charger, at 50 kW to over 350 kW.
- Charge acceptance
How much of the current offered to a battery it can actually absorb at a given state of charge and temperature.
Start, stop and maintenance
- Low-voltage precharge and automatic recharge
A compatible charging controller can start eligible low-voltage cells at reduced current and later enter normal charging.
- Target state-of-charge charging
A target state of charge ends an ordinary charge session when the estimated charge fraction reaches the requested goal.
- Boost and top-up charging
A short, partial charge to add range quickly — often only into the part of the SOC window where the cell accepts high current best, typically 10–80 %.
- Trickle charging
Trickle charging supplies a small maintenance current for chemistries and cells approved for it.
- Float charging
Float charging holds a specified standby voltage to offset self-discharge in batteries designed for continuous maintenance.
- Lead–acid bulk, absorption and float charging
A common lead–acid charging sequence uses current-limited bulk charge, a regulated absorption voltage with tapering current, and a lower float voltage for standby service.
- Equalization charge
A deliberate, controlled overcharge of a lead–acid battery that brings weaker cells up to full and stirs the electrolyte.
- Nickel battery peak-voltage and thermal termination
A compatible nickel battery charger can terminate a current-controlled stage by detecting a voltage peak or subsequent drop.
- IU, IUoU and IUI charging
The letter code, set out in DIN 41772, for a charger’s profile: I for a constant-current stage, U for constant voltage and W for current that falls as voltage rises.
- Negative delta V
Negative delta V is a small decline in nickel battery voltage after its charging peak.
- dT/dt termination
A temperature-rise-rate criterion ends nickel battery charging when the measured temperature slope reaches the approved condition.
- Charge termination
Charge termination is the decision to end a charging stage or session.
- Refresh charge
A refresh charge restores charge lost during storage.
- Reconditioning
Battery reconditioning is a manufacturer-defined service process that may use controlled discharge and recharge to address some forms of reversible capacity loss in eligible nickel batteries.
Vehicle and site strategies
- Smart charging
Controlling when and how fast vehicles charge to fit grid capacity, electricity prices and departure times, rather than charging at full power on arrival.
- Scheduled and managed charging
Scheduled charging chooses when charging begins or pauses, while managed charging may also set a power budget across several vehicles or storage units.
- Depot charging
Charging a fleet of buses or trucks at the depot, usually overnight at 50–150 kW per vehicle, which keeps cell stress low and lets an energy-management system sequence the chargers against the site’s grid connection.
- Opportunity charging
Topping up a vehicle in short, high-power bursts wherever it stops anyway — a bus at its terminus or at stops, a forklift at breaks — instead of carrying enough energy for the whole day.
- Split-pack charging
Reconfiguring a pack with contactors so that its two halves charge in parallel at half the drive voltage.
- Regenerative braking
Using a vehicle’s motor as a generator while slowing down, so braking energy charges the battery in short high-current pulses.