Battery knowledge · Charging and discharging

Battery charging strategies

Battery charging strategies define how a charger commands current, voltage or power and how it decides to change stages or stop. Chemistry, temperature, battery state and infrastructure also determine which strategies are applicable. [1] [2] [3]

Browse by category ↓

Compare charging profiles

See which quantity is held constant, when the phase changes and how charging ends.

Current profile
Current profileRelative elapsed time versus Current (A). Charge current. Interpretation follows the graphs.CCCVStop001.440.252.880.54.310.755.751Relative elapsed timeCurrent (A)
Charge current
Voltage profile
Voltage profileRelative elapsed time versus Cell voltage (V). Cell voltage. Interpretation follows the graphs.CCCVStop303.350.253.70.54.050.754.41Relative elapsed timeCell voltage (V)
Cell voltage

Current holds at 5 A until the example 4.15 V threshold; voltage then holds while current tapers. The stop marker is a separate low-current termination condition.

CC: I = I_set · CV: V = V_limit

Illustrative model. Positive current charges the cell. Time is normalized; selected thresholds are not cell-specific recommendations. The voltage trace ends at termination; post-stop relaxation is excluded.

Example

Worked example

Compare a current-limited session, a power-limited session and a stepped current schedule at the same starting state of charge. Look for phase transitions and record the achieved charge separately from the peak current.

Use in Lemonergy

Separate regulation from availability.

This is a reference concept. No executable Lemonergy block has been verified for this term.

References & further reading

Technical references

  1. Closed-loop optimization of fast-charging protocols for batteries with machine learning

    Nature

    Technical reference · Experimental selection of multistep lithium-ion charging profiles. Figure shape and settings here are independently authored.

  2. Insight into pulse-charging for lithium plating-free fast-charging lithium-ion batteries

    Electrochimica Acta

    Technical reference · Experimental and modeling study of pulse charging and lithium plating under the study conditions.

  3. Lithium-ion battery fast charging: A review

    Anna Tomaszewska et al. · eTransportation · 2019

    Technical reference · CC-CV and alternative charging protocols, transport limitations, degradation and thermal implications; results depend on cell and test conditions. Software behavior is documented separately in Lemonergy block references.

Browse by category

Basic electrical profiles

  • Constant current

    A charge or discharge at a fixed current, so capacity is simply current times time.

  • Constant voltage

    A charge stage in which the terminal voltage is held at a selected limit while the current is allowed to fall.

  • CC-CV charging

    The standard lithium-ion charge protocol: constant current until the cell reaches its upper cutoff voltage, then that voltage held constant while the current tapers.

  • Constant-power charging

    Constant-power charging regulates the product of terminal voltage and current.

  • Constant power followed by constant voltage

    Constant power followed by constant voltage is a two-stage charging profile.

  • Multistage constant-current charging

    A charge protocol with a sequence of constant-current stages, often reducing current as the cell fills.

  • Multistage constant current with CV finish

    A multistage current schedule uses several constant-current plateaus before a final constant-voltage stage.

  • Ramped-current charging

    A ramped charger increases or decreases its current command continuously over a time or state interval.

  • Taper charging

    Charging from a source whose current falls by itself as the battery voltage rises — classically a transformer and rectifier with no regulation.

Pulse and feedback profiles

  • Pulse charging

    Charging with current pulses separated by rests or short discharges, intended to let concentration gradients relax and reduce plating.

  • Reverse-pulse charging

    Reverse-pulse charging inserts brief discharge intervals into a net charging sequence.

  • Adaptive charging

    Charging whose current and voltage limits adjust in real time to what the battery can safely take — its temperature, state of charge, health or impedance — or to when it is needed.

  • Model-predictive battery charging

    Model-predictive charging estimates future battery behavior and chooses a current sequence subject to model and operating constraints.

  • Non-linear voltammetry charging

    Non-linear voltammetry charging uses a deliberately shaped potential trajectory or adaptively varies the voltage ramp while observing current.

Temperature and charging speed

  • Temperature-conditioned charging

    Temperature-conditioned charging changes cell temperature before allowing more current, or limits the request using measured temperature during charging.

  • Preconditioning

    Warming or cooling the battery to its preferred temperature before a fast charge or a hard drive, using the vehicle’s own heaters and pumps.

  • AC slow charging

    Charging through the vehicle’s onboard charger from an AC socket or wallbox, at a few kilowatts up to 22 kW.

  • Fast charging

    Charging intended to replenish a specified amount of energy or state of charge in a short time.

  • Extreme fast charging

    Charging a vehicle battery in about 10–15 minutes, roughly 4C to 6C — the US Department of Energy’s research target that set the term.

  • DC fast charging

    Charging from a station that supplies DC straight to the pack, bypassing the car’s onboard charger, at 50 kW to over 350 kW.

  • Charge acceptance

    How much of the current offered to a battery it can actually absorb at a given state of charge and temperature.

Start, stop and maintenance

  • Low-voltage precharge and automatic recharge

    A compatible charging controller can start eligible low-voltage cells at reduced current and later enter normal charging.

  • Target state-of-charge charging

    A target state of charge ends an ordinary charge session when the estimated charge fraction reaches the requested goal.

  • Boost and top-up charging

    A short, partial charge to add range quickly — often only into the part of the SOC window where the cell accepts high current best, typically 10–80 %.

  • Trickle charging

    Trickle charging supplies a small maintenance current for chemistries and cells approved for it.

  • Float charging

    Float charging holds a specified standby voltage to offset self-discharge in batteries designed for continuous maintenance.

  • Lead–acid bulk, absorption and float charging

    A common lead–acid charging sequence uses current-limited bulk charge, a regulated absorption voltage with tapering current, and a lower float voltage for standby service.

  • Equalization charge

    A deliberate, controlled overcharge of a lead–acid battery that brings weaker cells up to full and stirs the electrolyte.

  • Nickel battery peak-voltage and thermal termination

    A compatible nickel battery charger can terminate a current-controlled stage by detecting a voltage peak or subsequent drop.

  • IU, IUoU and IUI charging

    The letter code, set out in DIN 41772, for a charger’s profile: I for a constant-current stage, U for constant voltage and W for current that falls as voltage rises.

  • Negative delta V

    Negative delta V is a small decline in nickel battery voltage after its charging peak.

  • dT/dt termination

    A temperature-rise-rate criterion ends nickel battery charging when the measured temperature slope reaches the approved condition.

  • Charge termination

    Charge termination is the decision to end a charging stage or session.

  • Refresh charge

    A refresh charge restores charge lost during storage.

  • Reconditioning

    Battery reconditioning is a manufacturer-defined service process that may use controlled discharge and recharge to address some forms of reversible capacity loss in eligible nickel batteries.

Vehicle and site strategies

  • Smart charging

    Controlling when and how fast vehicles charge to fit grid capacity, electricity prices and departure times, rather than charging at full power on arrival.

  • Scheduled and managed charging

    Scheduled charging chooses when charging begins or pauses, while managed charging may also set a power budget across several vehicles or storage units.

  • Depot charging

    Charging a fleet of buses or trucks at the depot, usually overnight at 50–150 kW per vehicle, which keeps cell stress low and lets an energy-management system sequence the chargers against the site’s grid connection.

  • Opportunity charging

    Topping up a vehicle in short, high-power bursts wherever it stops anyway — a bus at its terminus or at stops, a forklift at breaks — instead of carrying enough energy for the whole day.

  • Split-pack charging

    Reconfiguring a pack with contactors so that its two halves charge in parallel at half the drive voltage.

  • Regenerative braking

    Using a vehicle’s motor as a generator while slowing down, so braking energy charges the battery in short high-current pulses.