  "node": {
    "id": "term:charging-strategies",
    "type": "Term",
    "label": "Battery charging strategies",
    "properties": {
      "id": "charging-strategies",
      "name": "Battery charging strategies",
      "section": "topic-charging",
      "definition": "Battery charging strategies define how a charger commands current, voltage or power and how it decides to change stages or stop. Chemistry, temperature, battery state and infrastructure also determine which strategies are applicable.",
      "related": [
        "cc-cv-charging",
        "mscc",
        "adaptive-charging",
        "lead-acid-bulk-absorption-float",
        "battery-test-equipment",
        "testing"
      ],
      "example": {
        "title": "Worked example",
        "text": "Compare a current-limited session, a power-limited session and a stepped current schedule at the same starting state of charge. Look for phase transitions and record the achieved charge separately from the peak current."
      },
      "guide": [
        {
          "title": "Basic electrical profiles",
          "terms": [
            "constant-current",
            "constant-voltage",
            "cc-cv-charging",
            "constant-power-charging",
            "cp-cv",
            "mscc",
            "mscc-cv",
            "ramped-current-charging",
            "taper-charging"
          ]
        },
        {
          "title": "Pulse and feedback profiles",
          "terms": [
            "pulse-charging",
            "reverse-pulse-charging",
            "adaptive-charging",
            "model-predictive-charging",
            "non-linear-voltammetry-charging"
          ]
        },
        {
          "title": "Temperature and charging speed",
          "terms": [
            "temperature-conditioned-charging",
            "preconditioning",
            "slow-charging",
            "fast-charging",
            "xfc",
            "dc-fast-charging",
            "charge-acceptance"
          ]
        },
        {
          "title": "Start, stop and maintenance",
          "terms": [
            "precharge-recharge",
            "target-soc-charging",
            "boost-charging",
            "trickle-charge",
            "float-charging",
            "lead-acid-bulk-absorption-float",
            "equalization-charge",
            "nickel-peak-termination",
            "iu-charging-characteristics",
            "negative-delta-v",
            "dt-dt-termination",
            "charge-termination",
            "refresh-charge",
            "reconditioning"
          ]
        },
        {
          "title": "Vehicle and site strategies",
          "terms": [
            "smart-charging",
            "scheduled-charging",
            "depot-charging",
            "opportunity-charging",
            "split-pack-charging",
            "regenerative-braking"
          ]
        }
      ],
      "url": "https://lemonergy.com/learn/glossary/charging-strategies/",
      "mentions": [
        "charger"
      ]
    }
  },
  "edges": [
    {
      "id": "edge:belongsTo/term:charging-strategies/topic:topic-charging",
      "source": "term:charging-strategies",
      "target": "topic:topic-charging",
      "type": "belongsTo",
      "properties": {
        "sourceFile": "terms.json"
      }
    },
    {
      "id": "edge:relatedTo/term:charging-strategies/term:cc-cv-charging",
      "source": "term:charging-strategies",
      "target": "term:cc-cv-charging",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:charging-strategies/term:mscc",
      "source": "term:charging-strategies",
      "target": "term:mscc",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:charging-strategies/term:adaptive-charging",
      "source": "term:charging-strategies",
      "target": "term:adaptive-charging",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:charging-strategies/term:lead-acid-bulk-absorption-float",
      "source": "term:charging-strategies",
      "target": "term:lead-acid-bulk-absorption-float",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:charging-strategies/term:battery-test-equipment",
      "source": "term:charging-strategies",
      "target": "term:battery-test-equipment",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:charging-strategies/term:testing",
      "source": "term:charging-strategies",
      "target": "term:testing",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:constant-current",
      "source": "term:charging-strategies",
      "target": "term:constant-current",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Basic electrical profiles"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:constant-voltage",
      "source": "term:charging-strategies",
      "target": "term:constant-voltage",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Basic electrical profiles"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:cc-cv-charging",
      "source": "term:charging-strategies",
      "target": "term:cc-cv-charging",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Basic electrical profiles"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:constant-power-charging",
      "source": "term:charging-strategies",
      "target": "term:constant-power-charging",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Basic electrical profiles"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:cp-cv",
      "source": "term:charging-strategies",
      "target": "term:cp-cv",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Basic electrical profiles"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:mscc",
      "source": "term:charging-strategies",
      "target": "term:mscc",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Basic electrical profiles"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:mscc-cv",
      "source": "term:charging-strategies",
      "target": "term:mscc-cv",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Basic electrical profiles"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:ramped-current-charging",
      "source": "term:charging-strategies",
      "target": "term:ramped-current-charging",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Basic electrical profiles"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:taper-charging",
      "source": "term:charging-strategies",
      "target": "term:taper-charging",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Basic electrical profiles"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:pulse-charging",
      "source": "term:charging-strategies",
      "target": "term:pulse-charging",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Pulse and feedback profiles"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:reverse-pulse-charging",
      "source": "term:charging-strategies",
      "target": "term:reverse-pulse-charging",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Pulse and feedback profiles"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:adaptive-charging",
      "source": "term:charging-strategies",
      "target": "term:adaptive-charging",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Pulse and feedback profiles"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:model-predictive-charging",
      "source": "term:charging-strategies",
      "target": "term:model-predictive-charging",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Pulse and feedback profiles"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:non-linear-voltammetry-charging",
      "source": "term:charging-strategies",
      "target": "term:non-linear-voltammetry-charging",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Pulse and feedback profiles"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:temperature-conditioned-charging",
      "source": "term:charging-strategies",
      "target": "term:temperature-conditioned-charging",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Temperature and charging speed"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:preconditioning",
      "source": "term:charging-strategies",
      "target": "term:preconditioning",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Temperature and charging speed"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:slow-charging",
      "source": "term:charging-strategies",
      "target": "term:slow-charging",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Temperature and charging speed"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:fast-charging",
      "source": "term:charging-strategies",
      "target": "term:fast-charging",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Temperature and charging speed"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:xfc",
      "source": "term:charging-strategies",
      "target": "term:xfc",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Temperature and charging speed"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:dc-fast-charging",
      "source": "term:charging-strategies",
      "target": "term:dc-fast-charging",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Temperature and charging speed"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:charge-acceptance",
      "source": "term:charging-strategies",
      "target": "term:charge-acceptance",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Temperature and charging speed"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:precharge-recharge",
      "source": "term:charging-strategies",
      "target": "term:precharge-recharge",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Start, stop and maintenance"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:target-soc-charging",
      "source": "term:charging-strategies",
      "target": "term:target-soc-charging",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Start, stop and maintenance"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:boost-charging",
      "source": "term:charging-strategies",
      "target": "term:boost-charging",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Start, stop and maintenance"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:trickle-charge",
      "source": "term:charging-strategies",
      "target": "term:trickle-charge",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Start, stop and maintenance"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:float-charging",
      "source": "term:charging-strategies",
      "target": "term:float-charging",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Start, stop and maintenance"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:lead-acid-bulk-absorption-float",
      "source": "term:charging-strategies",
      "target": "term:lead-acid-bulk-absorption-float",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Start, stop and maintenance"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:equalization-charge",
      "source": "term:charging-strategies",
      "target": "term:equalization-charge",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Start, stop and maintenance"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:nickel-peak-termination",
      "source": "term:charging-strategies",
      "target": "term:nickel-peak-termination",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Start, stop and maintenance"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:iu-charging-characteristics",
      "source": "term:charging-strategies",
      "target": "term:iu-charging-characteristics",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Start, stop and maintenance"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:negative-delta-v",
      "source": "term:charging-strategies",
      "target": "term:negative-delta-v",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Start, stop and maintenance"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:dt-dt-termination",
      "source": "term:charging-strategies",
      "target": "term:dt-dt-termination",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Start, stop and maintenance"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:charge-termination",
      "source": "term:charging-strategies",
      "target": "term:charge-termination",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Start, stop and maintenance"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:refresh-charge",
      "source": "term:charging-strategies",
      "target": "term:refresh-charge",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Start, stop and maintenance"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:reconditioning",
      "source": "term:charging-strategies",
      "target": "term:reconditioning",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Start, stop and maintenance"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:smart-charging",
      "source": "term:charging-strategies",
      "target": "term:smart-charging",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Vehicle and site strategies"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:scheduled-charging",
      "source": "term:charging-strategies",
      "target": "term:scheduled-charging",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Vehicle and site strategies"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:depot-charging",
      "source": "term:charging-strategies",
      "target": "term:depot-charging",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Vehicle and site strategies"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:opportunity-charging",
      "source": "term:charging-strategies",
      "target": "term:opportunity-charging",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Vehicle and site strategies"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:split-pack-charging",
      "source": "term:charging-strategies",
      "target": "term:split-pack-charging",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Vehicle and site strategies"
      }
    },
    {
      "id": "edge:guideIncludes/term:charging-strategies/term:regenerative-braking",
      "source": "term:charging-strategies",
      "target": "term:regenerative-braking",
      "type": "guideIncludes",
      "properties": {
        "sourceFile": "wiki-editorial.json",
        "group": "Vehicle and site strategies"
      }
    },
    {
      "id": "edge:mentions/charging-strategies/charger",
      "source": "term:charging-strategies",
      "target": "term:charger",
      "type": "mentions",
      "properties": {
        "sourceFile": "terms.json",
        "method": "build_glossary.mention_index + mentions",
        "field": "definition",
        "meaning": "Text mention; not a causal claim"
      }
    },
    {
      "id": "edge:illustratedBy/term:charging-strategies/visual:charging-cccv",
      "source": "term:charging-strategies",
      "target": "visual:charging-cccv",
      "type": "illustratedBy",
      "properties": {
        "sourceFile": "visual-pages.json"
      }
    },
    {
      "id": "edge:cites/term:charging-strategies/reference:tomaszewska-charging",
      "source": "term:charging-strategies",
      "target": "reference:tomaszewska-charging",
      "type": "cites",
      "properties": {
        "sourceFile": "wiki-references.json",
        "scope": "direct technical reference"
      }
    },
    {
      "id": "edge:cites/term:charging-strategies/reference:attia-charge",
      "source": "term:charging-strategies",
      "target": "reference:attia-charge",
      "type": "cites",
      "properties": {
        "sourceFile": "wiki-references.json",
        "scope": "direct technical reference"
      }
    },
    {
      "id": "edge:cites/term:charging-strategies/reference:shin-pulse-charge",
      "source": "term:charging-strategies",
      "target": "reference:shin-pulse-charge",
      "type": "cites",
      "properties": {
        "sourceFile": "wiki-references.json",
        "scope": "direct technical reference"
      }
    }
  ],
  "neighbors": [
    {
      "id": "topic:topic-charging",
      "type": "Topic",
      "label": "Charging and discharging",
      "properties": {
        "id": "topic-charging",
        "name": "Charging and discharging",
        "lede": "How current goes in and comes out, and the limits that stop it.",
        "context": "Separate regulation from availability.",
        "example": "The same CC–CV law can operate overnight or during a short depot stop.",
        "lesson_url": "https://lemonergy.com/learn/fundamentals/capacity-and-c-rate/",
        "lesson_label": "Open charging quantities"
      }
    },
    {
      "id": "term:cc-cv-charging",
      "type": "Term",
      "label": "CC-CV charging",
      "properties": {
        "id": "cc-cv-charging",
        "name": "CC-CV charging",
        "aka": [
          "constant current constant voltage"
        ],
        "section": "topic-charging",
        "definition": "The standard lithium-ion charge protocol: constant current until the cell reaches its upper cutoff voltage, then that voltage held constant while the current tapers. The charge ends when the current falls to a set fraction, often C/20.",
        "related": [
          "constant-current",
          "constant-voltage",
          "cutoff-voltage",
          "taper-current",
          "fast-charging",
          "cp-cv"
        ],
        "lesson": "fundamentals/capacity-and-c-rate/#real-cells",
        "example": {
          "title": "Follow a two-stage charge",
          "text": "For an illustrative 5 Ah cell, a 2.5 A current request is 0.5C. During CC the voltage rises. At the selected upper voltage, CV regulation holds voltage while current tapers. Completion requires the taper current to fall below the selected cutoff for the configured dwell."
        },
        "notes": [
          "Choose voltage, current and temperature limits from the actual cell specification. These example values do not define a charging recipe."
        ],
        "url": "https://lemonergy.com/learn/glossary/cc-cv-charging/",
        "mentions": []
      }
    },
    {
      "id": "term:mscc",
      "type": "Term",
      "label": "Multistage constant-current charging",
      "properties": {
        "id": "mscc",
        "name": "Multistage constant-current charging",
        "abbr": "MSCC",
        "aka": [
          "step charging",
          "stepped CC"
        ],
        "section": "topic-charging",
        "definition": "A charge protocol with a sequence of constant-current stages, often reducing current as the cell fills. Stage transitions follow selected time, voltage, state-of-charge or other limits. Charging time and lithium-plating risk depend on the cell and control conditions; a staged profile alone does not establish an improvement.",
        "related": [
          "cc-cv-charging",
          "fast-charging",
          "lithium-plating",
          "charging-curve",
          "xfc",
          "pulse-charging"
        ],
        "example": {
          "title": "Build a staged current profile",
          "text": "An illustrative sequence uses 3 A for 10 min, then 2 A for 10 min, then 1 A for 10 min. If every stage runs for its full duration, the charge transferred is 1 Ah. Voltage and temperature limits can terminate stages earlier."
        },
        "notes": [
          "A sequence of CC steps is distinct from an automatically combined multistage CC-CV charger."
        ],
        "url": "https://lemonergy.com/learn/glossary/mscc/",
        "mentions": []
      }
    },
    {
      "id": "term:adaptive-charging",
      "type": "Term",
      "label": "Adaptive charging",
      "properties": {
        "id": "adaptive-charging",
        "name": "Adaptive charging",
        "aka": [
          "optimised charging",
          "optimized battery charging",
          "intelligent charging"
        ],
        "section": "topic-charging",
        "definition": "Charging whose current and voltage limits adjust in real time to what the battery can safely take — its temperature, state of charge, health or impedance — or to when it is needed. Phones that hold at 80 % overnight and finish shortly before the owner wakes are an everyday example; vehicle chargers use the same idea against lithium plating.",
        "related": [
          "mscc",
          "lithium-plating",
          "state-of-health",
          "smart-charging",
          "storage-soc",
          "non-linear-voltammetry-charging"
        ],
        "url": "https://lemonergy.com/learn/glossary/adaptive-charging/",
        "mentions": [
          "impedance",
          "state-of-charge"
        ]
      }
    },
    {
      "id": "term:lead-acid-bulk-absorption-float",
      "type": "Term",
      "label": "Lead–acid bulk, absorption and float charging",
      "properties": {
        "id": "lead-acid-bulk-absorption-float",
        "name": "Lead–acid bulk, absorption and float charging",
        "section": "topic-charging",
        "definition": "A common lead–acid charging sequence uses current-limited bulk charge, a regulated absorption voltage with tapering current, and a lower float voltage for standby service. Product specifications determine whether and how each stage is used.",
        "related": [
          "lead-acid",
          "trickle-charge",
          "equalization-charge",
          "float-charging",
          "charging-strategies"
        ],
        "example": {
          "title": "Worked example",
          "text": "On a relative voltage plot, identify the higher absorption plateau before the lower float plateau. At the same standby voltage, maintenance current can vary with conditions and battery state."
        },
        "url": "https://lemonergy.com/learn/glossary/lead-acid-bulk-absorption-float/",
        "mentions": []
      }
    },
    {
      "id": "term:battery-test-equipment",
      "type": "Term",
      "label": "Battery testing equipment",
      "properties": {
        "id": "battery-test-equipment",
        "name": "Battery testing equipment",
        "section": "topic-testing-equipment",
        "definition": "Battery testing equipment controls the electrical and environmental conditions applied to a cell, module or pack and records its response. The test objective determines the instrument, fixture, sensing range and safety provisions.",
        "related": [
          "testing",
          "cycler",
          "potentiostat",
          "charging-strategies"
        ],
        "example": {
          "title": "Worked example",
          "text": "A capacity bench and an environmental screening station may both record voltage and temperature. Only the capacity bench needs a calibrated source and load that can integrate current over the full cycle."
        },
        "guide": [
          {
            "title": "Source, sink and electrical measurement",
            "terms": [
              "cycler",
              "bidirectional-dc-supply",
              "electronic-load",
              "battery-current-transducer",
              "battery-cell-fixture",
              "kelvin-sensing",
              "voltage-sense"
            ]
          },
          {
            "title": "Electrochemical instrumentation",
            "terms": [
              "potentiostat",
              "battery-impedance-analyzer",
              "working-and-counter-electrode",
              "reference-electrode"
            ]
          },
          {
            "title": "Environment, thermal and mechanical equipment",
            "terms": [
              "battery-test-chamber",
              "thermocouples-rtds",
              "battery-coolant-conditioner",
              "battery-altitude-chamber",
              "battery-calorimeter",
              "battery-shaker",
              "battery-material-test-frame",
              "battery-thickness-gauge",
              "laser-flash-analyzer",
              "transient-plane-source-analyzer"
            ]
          },
          {
            "title": "Safety, controls and inspection",
            "terms": [
              "battery-data-acquisition",
              "insulation-resistance-tester",
              "dielectric-withstand-tester",
              "battery-abuse-enclosure",
              "battery-gas-analysis",
              "battery-pack-hil-bench",
              "x-ray-computed-tomography",
              "scanning-electron-microscopy",
              "gas-chromatography-mass-spectrometry",
              "helium-leak-detector",
              "battery-ultrasound-instrument"
            ]
          }
        ],
        "url": "https://lemonergy.com/learn/glossary/battery-test-equipment/",
        "mentions": []
      }
    },
    {
      "id": "term:testing",
      "type": "Term",
      "label": "Battery testing procedures",
      "properties": {
        "id": "testing",
        "name": "Battery testing procedures",
        "section": "topic-testing",
        "definition": "Battery testing procedures describe how to characterize performance, durability, environmental behavior and safety at cell, module or pack level. A test plan defines the specimen, conditions, equipment, measurements and the applicable evaluation method.",
        "related": [
          "capacity-test",
          "cycler",
          "reference-performance-test",
          "abuse-testing",
          "datasheet",
          "charging-strategies"
        ],
        "aka": [
          "Cell testing"
        ],
        "testChooser": [
          {
            "goal": "Measure performance",
            "term": "capacity-test",
            "title": "Capacity test",
            "description": "Measure how much charge and energy the battery delivers under defined conditions.",
            "details": {
              "Equipment": "Cycler, temperature chamber, and cell fixture",
              "Procedure": "Condition the cell, then discharge at the specified current",
              "Record": "Ah, Wh, temperature, and cutoff voltage"
            },
            "action": "Open the capacity test"
          },
          {
            "goal": "Understand aging",
            "term": "cycle-life-test",
            "title": "Cycle-life test",
            "description": "Track how repeated cycling changes capacity and resistance.",
            "details": {
              "Equipment": "Cycler, temperature chamber, and data logger",
              "Procedure": "Cycle the battery and repeat reference performance tests",
              "Record": "Capacity, resistance, and charge throughput"
            },
            "action": "Open the cycle-life test"
          },
          {
            "goal": "Investigate a failure",
            "term": "post-mortem",
            "title": "Post-mortem analysis",
            "description": "Connect observations from a failed battery to the affected component and its test history.",
            "details": {
              "Equipment": "Specialist lab with appropriate containment",
              "Procedure": "Trace each sample to its location in the battery",
              "Record": "Test history, sample location, and preparation"
            },
            "action": "Open the post-mortem guide"
          },
          {
            "goal": "Plan qualification",
            "term": "transport-regulations",
            "title": "Start with the applicable standard",
            "description": "Match the test program to the product and its intended use. For transport, check which UN 38.3 tests apply.",
            "details": {
              "Define": "Specimen and intended use",
              "Confirm": "Applicable method and edition",
              "Record": "Test results and report reference"
            },
            "action": "Open the UN 38.3 guide"
          }
        ],
        "example": {
          "title": "Worked example",
          "text": "Choose an initial capacity test and pulse resistance baseline for the same specimen. Keep the state of charge, temperature and instrument channels comparable so later repeat measurements can reveal changes."
        },
        "guide": [
          {
            "title": "Performance and efficiency",
            "terms": [
              "capacity-test",
              "rate-test",
              "ocv-test",
              "pulse-test",
              "hppc",
              "dcir",
              "acir",
              "fast-charge-capability-test",
              "round-trip-efficiency-test",
              "drive-cycle-battery-test"
            ]
          },
          {
            "title": "Aging and thermal measurements",
            "terms": [
              "cycle-life-test",
              "calendar-life-test",
              "reference-performance-test",
              "self-discharge-test",
              "thermal-characterisation",
              "isothermal-calorimetry",
              "accelerating-rate-calorimetry"
            ]
          },
          {
            "title": "Electrochemical and material diagnostics",
            "terms": [
              "electrochemical-impedance-spectroscopy",
              "gitt",
              "pitt",
              "cyclic-voltammetry",
              "chronoamperometry",
              "chronopotentiometry",
              "ultra-high-precision-coulometry",
              "differential-voltage-analysis",
              "incremental-capacity-analysis",
              "laser-flash-analysis",
              "hot-disk-method",
              "ultrasonic-cell-testing",
              "x-ray-computed-tomography",
              "post-mortem"
            ]
          },
          {
            "title": "Manufacturing and battery management",
            "terms": [
              "end-of-line-testing",
              "electrode-peel-test",
              "tab-pull-test",
              "helium-leak-test",
              "swelling-test",
              "fault-injection-testing",
              "insulation-test",
              "dielectric-withstand-test"
            ]
          },
          {
            "title": "Environment and mechanics",
            "terms": [
              "altitude-simulation-test",
              "thermal-shock-test",
              "vibration-test",
              "mechanical-shock-test",
              "damp-heat-test",
              "salt-spray-test",
              "immersion-test",
              "halt-hass",
              "impact-test"
            ]
          },
          {
            "title": "Safety and abuse",
            "terms": [
              "abuse-testing",
              "oven-test",
              "crush-test",
              "nail-penetration",
              "overcharge-test",
              "short-circuit-test",
              "propagation-test",
              "vehicle-crash-test",
              "transport-impact-crush-test",
              "forced-discharge-test"
            ]
          },
          {
            "title": "Transport and qualification references",
            "terms": [
              "transport-regulations",
              "iec-62660",
              "iso-12405",
              "iec-62133",
              "iec-62619",
              "un-r100",
              "ul-9540a"
            ]
          }
        ],
        "url": "https://lemonergy.com/learn/glossary/testing/",
        "mentions": []
      }
    },
    {
      "id": "term:constant-current",
      "type": "Term",
      "label": "Constant current",
      "properties": {
        "id": "constant-current",
        "name": "Constant current",
        "abbr": "CC",
        "section": "topic-charging",
        "definition": "A charge or discharge at a fixed current, so capacity is simply current times time. It is the first stage of a CC-CV charge and the normal way to run a capacity test.",
        "related": [
          "cc-cv-charging",
          "constant-voltage",
          "c-rate",
          "capacity-test",
          "charging-strategies"
        ],
        "example": {
          "title": "Compare two cell capacities",
          "text": "A 2 A current is 1C for a 2 Ah cell and 0.4C for a 5 Ah cell. A constant-current step holds amperes fixed, so a fair comparison between differently sized cells also records C-rate."
        },
        "url": "https://lemonergy.com/learn/glossary/constant-current/",
        "mentions": []
      }
    },
    {
      "id": "term:constant-voltage",
      "type": "Term",
      "label": "Constant voltage",
      "properties": {
        "id": "constant-voltage",
        "name": "Constant voltage",
        "abbr": "CV",
        "section": "topic-charging",
        "definition": "A charge stage in which the terminal voltage is held at a selected limit while the current is allowed to fall. The charge added during this stage and its duration depend on the cell, initial state, voltage limit and termination current.",
        "related": [
          "cc-cv-charging",
          "constant-current",
          "taper-current",
          "cutoff-voltage",
          "charging-strategies"
        ],
        "example": {
          "title": "Read the taper correctly",
          "text": "In a hypothetical CV stage with a 4.0 V ceiling, the controller holds terminal voltage at that ceiling while current tapers as the cell state changes and its OCV rises. A voltage plateau does not mean the charge session has completed; the current cutoff and dwell still matter."
        },
        "url": "https://lemonergy.com/learn/glossary/constant-voltage/",
        "mentions": [
          "voltage"
        ]
      }
    },
    {
      "id": "term:cc-cv-charging",
      "type": "Term",
      "label": "CC-CV charging",
      "properties": {
        "id": "cc-cv-charging",
        "name": "CC-CV charging",
        "aka": [
          "constant current constant voltage"
        ],
        "section": "topic-charging",
        "definition": "The standard lithium-ion charge protocol: constant current until the cell reaches its upper cutoff voltage, then that voltage held constant while the current tapers. The charge ends when the current falls to a set fraction, often C/20.",
        "related": [
          "constant-current",
          "constant-voltage",
          "cutoff-voltage",
          "taper-current",
          "fast-charging",
          "cp-cv"
        ],
        "lesson": "fundamentals/capacity-and-c-rate/#real-cells",
        "example": {
          "title": "Follow a two-stage charge",
          "text": "For an illustrative 5 Ah cell, a 2.5 A current request is 0.5C. During CC the voltage rises. At the selected upper voltage, CV regulation holds voltage while current tapers. Completion requires the taper current to fall below the selected cutoff for the configured dwell."
        },
        "notes": [
          "Choose voltage, current and temperature limits from the actual cell specification. These example values do not define a charging recipe."
        ],
        "url": "https://lemonergy.com/learn/glossary/cc-cv-charging/",
        "mentions": []
      }
    },
    {
      "id": "term:constant-power-charging",
      "type": "Term",
      "label": "Constant-power charging",
      "properties": {
        "id": "constant-power-charging",
        "name": "Constant-power charging",
        "section": "topic-charging",
        "definition": "Constant-power charging regulates the product of terminal voltage and current. As terminal voltage rises, current falls until another limit takes priority or the session ends.",
        "related": [
          "cp-cv",
          "constant-current",
          "power",
          "charging-strategies"
        ],
        "example": {
          "title": "Worked example",
          "text": "At an illustrative 12 W, current is 4 A when the terminal voltage is 3 V and 3 A when it is 4 V. The arithmetic does not set a cell limit."
        },
        "url": "https://lemonergy.com/learn/glossary/constant-power-charging/",
        "mentions": [
          "voltage"
        ]
      }
    },
    {
      "id": "term:cp-cv",
      "type": "Term",
      "label": "Constant power followed by constant voltage",
      "properties": {
        "id": "cp-cv",
        "name": "Constant power followed by constant voltage",
        "abbr": "CP-CV",
        "section": "topic-charging",
        "definition": "Constant power followed by constant voltage is a two-stage charging profile. Current declines as terminal voltage rises during power regulation, then tapers under voltage regulation after the upper voltage boundary is reached.",
        "related": [
          "cc-cv-charging",
          "constant-voltage",
          "e-rate",
          "charger",
          "charging-strategies"
        ],
        "example": {
          "title": "See why current falls at constant power",
          "text": "An illustrative 20 W constant-power stage requires 5 A at 4 V and 4 A at 5 V. At the chosen voltage ceiling, the profile changes to CV and power tapers with current."
        },
        "notes": [
          "This arithmetic illustrates P = VI; these voltages are not recommendations for a lithium-ion cell."
        ],
        "url": "https://lemonergy.com/learn/glossary/cp-cv/",
        "mentions": [
          "voltage"
        ]
      }
    },
    {
      "id": "term:mscc",
      "type": "Term",
      "label": "Multistage constant-current charging",
      "properties": {
        "id": "mscc",
        "name": "Multistage constant-current charging",
        "abbr": "MSCC",
        "aka": [
          "step charging",
          "stepped CC"
        ],
        "section": "topic-charging",
        "definition": "A charge protocol with a sequence of constant-current stages, often reducing current as the cell fills. Stage transitions follow selected time, voltage, state-of-charge or other limits. Charging time and lithium-plating risk depend on the cell and control conditions; a staged profile alone does not establish an improvement.",
        "related": [
          "cc-cv-charging",
          "fast-charging",
          "lithium-plating",
          "charging-curve",
          "xfc",
          "pulse-charging"
        ],
        "example": {
          "title": "Build a staged current profile",
          "text": "An illustrative sequence uses 3 A for 10 min, then 2 A for 10 min, then 1 A for 10 min. If every stage runs for its full duration, the charge transferred is 1 Ah. Voltage and temperature limits can terminate stages earlier."
        },
        "notes": [
          "A sequence of CC steps is distinct from an automatically combined multistage CC-CV charger."
        ],
        "url": "https://lemonergy.com/learn/glossary/mscc/",
        "mentions": []
      }
    },
    {
      "id": "term:mscc-cv",
      "type": "Term",
      "label": "Multistage constant current with CV finish",
      "properties": {
        "id": "mscc-cv",
        "name": "Multistage constant current with CV finish",
        "section": "topic-charging",
        "definition": "A multistage current schedule uses several constant-current plateaus before a final constant-voltage stage. Current then tapers under voltage regulation until an approved termination criterion is met.",
        "related": [
          "mscc",
          "cc-cv-charging",
          "cutoff-voltage",
          "charging-strategies"
        ],
        "example": {
          "title": "Worked example",
          "text": "In a normalized example, three progressively lower current plateaus are followed by a smoothly falling tail. The flat voltage trace identifies the final stage, even though the current was already falling in steps."
        },
        "url": "https://lemonergy.com/learn/glossary/mscc-cv/",
        "mentions": []
      }
    },
    {
      "id": "term:ramped-current-charging",
      "type": "Term",
      "label": "Ramped-current charging",
      "properties": {
        "id": "ramped-current-charging",
        "name": "Ramped-current charging",
        "section": "topic-charging",
        "definition": "A ramped charger increases or decreases its current command continuously over a time or state interval. Slew limits can smooth transitions between stages while independent battery limits remain active.",
        "related": [
          "constant-current",
          "adaptive-charging",
          "derating",
          "charging-strategies"
        ],
        "example": {
          "title": "Worked example",
          "text": "Compare a step from zero to full request with a gradual ramp to the same request. The ramp reaches the same peak while transferring less charge during the opening interval."
        },
        "url": "https://lemonergy.com/learn/glossary/ramped-current-charging/",
        "mentions": [
          "charger"
        ]
      }
    },
    {
      "id": "term:taper-charging",
      "type": "Term",
      "label": "Taper charging",
      "properties": {
        "id": "taper-charging",
        "name": "Taper charging",
        "aka": [
          "taper charger",
          "constant-potential charging",
          "unregulated charging",
          "W-characteristic charger"
        ],
        "section": "topic-charging",
        "definition": "Charging from a source whose current falls by itself as the battery voltage rises — classically a transformer and rectifier with no regulation. Cheap, and once common for lead–acid, it overcharges unless timed. In lithium-ion usage the phrase often means simply the constant-voltage stage, in which current tapers towards the taper current.",
        "related": [
          "taper-current",
          "iu-charging-characteristics",
          "lead-acid",
          "cc-cv-charging",
          "overcharge"
        ],
        "url": "https://lemonergy.com/learn/glossary/taper-charging/",
        "mentions": []
      }
    },
    {
      "id": "term:pulse-charging",
      "type": "Term",
      "label": "Pulse charging",
      "properties": {
        "id": "pulse-charging",
        "name": "Pulse charging",
        "aka": [
          "burp charging",
          "reflex charging",
          "negative pulse charging"
        ],
        "section": "topic-charging",
        "definition": "Charging with current pulses separated by rests or short discharges, intended to let concentration gradients relax and reduce plating. Benefits for lithium-ion are modest and depend on the cell; it is not standard practice.",
        "related": [
          "fast-charging",
          "lithium-plating",
          "relaxation",
          "charging-strategies"
        ],
        "example": {
          "title": "Separate peak from average current",
          "text": "A 4 A charge pulse that is on for 10 s and off for 10 s has a 2 A average over one full period. Its peak current is still 4 A. Matching average current alone does not match instantaneous heating or electrochemical response."
        },
        "url": "https://lemonergy.com/learn/glossary/pulse-charging/",
        "mentions": []
      }
    },
    {
      "id": "term:reverse-pulse-charging",
      "type": "Term",
      "label": "Reverse-pulse charging",
      "properties": {
        "id": "reverse-pulse-charging",
        "name": "Reverse-pulse charging",
        "section": "topic-charging",
        "definition": "Reverse-pulse charging inserts brief discharge intervals into a net charging sequence. Charge and discharge pulses are separately limited, and the signed current integral determines the net charge transferred.",
        "related": [
          "pulse-charging",
          "pulse-test",
          "charge-acceptance",
          "charging-strategies"
        ],
        "example": {
          "title": "Worked example",
          "text": "When an illustrative duty cycle spends half its time at positive full-scale current and one-quarter at negative half-scale current, the net average is 0.375 of full scale."
        },
        "url": "https://lemonergy.com/learn/glossary/reverse-pulse-charging/",
        "mentions": []
      }
    },
    {
      "id": "term:adaptive-charging",
      "type": "Term",
      "label": "Adaptive charging",
      "properties": {
        "id": "adaptive-charging",
        "name": "Adaptive charging",
        "aka": [
          "optimised charging",
          "optimized battery charging",
          "intelligent charging"
        ],
        "section": "topic-charging",
        "definition": "Charging whose current and voltage limits adjust in real time to what the battery can safely take — its temperature, state of charge, health or impedance — or to when it is needed. Phones that hold at 80 % overnight and finish shortly before the owner wakes are an everyday example; vehicle chargers use the same idea against lithium plating.",
        "related": [
          "mscc",
          "lithium-plating",
          "state-of-health",
          "smart-charging",
          "storage-soc",
          "non-linear-voltammetry-charging"
        ],
        "url": "https://lemonergy.com/learn/glossary/adaptive-charging/",
        "mentions": [
          "impedance",
          "state-of-charge"
        ]
      }
    },
    {
      "id": "term:model-predictive-charging",
      "type": "Term",
      "label": "Model-predictive battery charging",
      "properties": {
        "id": "model-predictive-charging",
        "name": "Model-predictive battery charging",
        "section": "topic-charging",
        "definition": "Model-predictive charging estimates future battery behavior and chooses a current sequence subject to model and operating constraints. It applies the first action, then updates the prediction using new feedback.",
        "related": [
          "model-predictive-control",
          "adaptive-charging",
          "temperature-conditioned-charging",
          "charging-strategies"
        ],
        "example": {
          "title": "Worked example",
          "text": "A hypothetical forecast predicts less available headroom later in the session. A conservative command drops before that region, then the controller can recompute the plan when temperature and voltage are measured again."
        },
        "url": "https://lemonergy.com/learn/glossary/model-predictive-charging/",
        "mentions": []
      }
    },
    {
      "id": "term:non-linear-voltammetry-charging",
      "type": "Term",
      "label": "Non-linear voltammetry charging",
      "properties": {
        "id": "non-linear-voltammetry-charging",
        "name": "Non-linear voltammetry charging",
        "abbr": "NLV",
        "aka": [
          "nonlinear voltammetry charging",
          "NLV charging"
        ],
        "section": "topic-charging",
        "definition": "Non-linear voltammetry charging uses a deliberately shaped potential trajectory or adaptively varies the voltage ramp while observing current. Published implementations are research-specific and may use different objectives, feedback signals or constraints.",
        "related": [
          "fast-charging",
          "constant-voltage",
          "relaxation",
          "cc-cv-charging",
          "pulse-charging",
          "adaptive-charging"
        ],
        "url": "https://lemonergy.com/learn/glossary/non-linear-voltammetry-charging/",
        "mentions": []
      }
    },
    {
      "id": "term:temperature-conditioned-charging",
      "type": "Term",
      "label": "Temperature-conditioned charging",
      "properties": {
        "id": "temperature-conditioned-charging",
        "name": "Temperature-conditioned charging",
        "section": "topic-charging",
        "definition": "Temperature-conditioned charging changes cell temperature before allowing more current, or limits the request using measured temperature during charging. The conditioning system and charger are coordinated because battery heat and charging capability interact.",
        "related": [
          "preconditioning",
          "adaptive-charging",
          "charge-acceptance",
          "charging-strategies"
        ],
        "example": {
          "title": "Worked example",
          "text": "In the example, current stays at zero during conditioning and then follows an allowed envelope. The graph illustrates coordination without assuming a charging temperature or heat rate for any cell."
        },
        "url": "https://lemonergy.com/learn/glossary/temperature-conditioned-charging/",
        "mentions": [
          "charger"
        ]
      }
    },
    {
      "id": "term:preconditioning",
      "type": "Term",
      "label": "Preconditioning",
      "properties": {
        "id": "preconditioning",
        "name": "Preconditioning",
        "section": "topic-thermal",
        "definition": "Warming or cooling the battery to its preferred temperature before a fast charge or a hard drive, using the vehicle’s own heaters and pumps. Navigating to a charger triggers it in many cars, because a cold pack cannot accept high current safely.",
        "related": [
          "thermal-management",
          "fast-charging",
          "lithium-plating",
          "operating-temperature",
          "charging-strategies"
        ],
        "url": "https://lemonergy.com/learn/glossary/preconditioning/",
        "mentions": [
          "charger"
        ]
      }
    },
    {
      "id": "term:slow-charging",
      "type": "Term",
      "label": "AC slow charging",
      "properties": {
        "id": "slow-charging",
        "name": "AC slow charging",
        "aka": [
          "overnight charging",
          "destination charging",
          "Level 2"
        ],
        "section": "topic-infrastructure",
        "definition": "Charging through the vehicle’s onboard charger from an AC socket or wallbox, at a few kilowatts up to 22 kW. It takes hours, keeps the cells cool and gently loaded, and is how most private cars are charged.",
        "related": [
          "onboard-charger",
          "charging-modes",
          "depot-charging",
          "sae-j1772"
        ],
        "url": "https://lemonergy.com/learn/glossary/slow-charging/",
        "mentions": [
          "charger",
          "evse"
        ]
      }
    },
    {
      "id": "term:fast-charging",
      "type": "Term",
      "label": "Fast charging",
      "properties": {
        "id": "fast-charging",
        "name": "Fast charging",
        "section": "topic-charging",
        "definition": "Charging intended to replenish a specified amount of energy or state of charge in a short time. There is no universal C-rate threshold: performance depends on cell chemistry, temperature, starting state and power limits. High current can increase heating and lithium-plating risk, requiring appropriate limits.",
        "related": [
          "lithium-plating",
          "c-rate",
          "cc-cv-charging",
          "dc-fast-charging",
          "thermal-management",
          "mscc"
        ],
        "url": "https://lemonergy.com/learn/glossary/fast-charging/",
        "mentions": [
          "state-of-charge"
        ]
      }
    },
    {
      "id": "term:xfc",
      "type": "Term",
      "label": "Extreme fast charging",
      "properties": {
        "id": "xfc",
        "name": "Extreme fast charging",
        "abbr": "XFC",
        "section": "topic-charging",
        "definition": "Charging a vehicle battery in about 10–15 minutes, roughly 4C to 6C — the US Department of Energy’s research target that set the term. At these rates lithium plating, heat and electrolyte transport limit the cell, so XFC needs thin or structured electrodes, strong cooling and careful protocols.",
        "related": [
          "fast-charging",
          "lithium-plating",
          "hpc",
          "areal-loading",
          "mscc",
          "charging-strategies"
        ],
        "url": "https://lemonergy.com/learn/glossary/xfc/",
        "mentions": [
          "electrolyte"
        ]
      }
    },
    {
      "id": "term:dc-fast-charging",
      "type": "Term",
      "label": "DC fast charging",
      "properties": {
        "id": "dc-fast-charging",
        "name": "DC fast charging",
        "abbr": "DCFC",
        "aka": [
          "rapid charging",
          "HPC"
        ],
        "section": "topic-infrastructure",
        "definition": "Charging from a station that supplies DC straight to the pack, bypassing the car’s onboard charger, at 50 kW to over 350 kW. The BMS, not the charger, sets the current from moment to moment, which is why the charge curve tapers as the pack fills.",
        "related": [
          "fast-charging",
          "onboard-charger",
          "pack-voltage",
          "preconditioning",
          "charging-curve",
          "evse"
        ],
        "url": "https://lemonergy.com/learn/glossary/dc-fast-charging/",
        "mentions": [
          "charger",
          "bms"
        ]
      }
    },
    {
      "id": "term:charge-acceptance",
      "type": "Term",
      "label": "Charge acceptance",
      "properties": {
        "id": "charge-acceptance",
        "name": "Charge acceptance",
        "section": "topic-charging",
        "definition": "How much of the current offered to a battery it can actually absorb at a given state of charge and temperature. It falls as the battery fills and as it cools, which is why regenerative braking and fast charging are limited by the battery rather than the source.",
        "related": [
          "fast-charging",
          "regenerative-braking",
          "state-of-power",
          "derating",
          "charging-strategies"
        ],
        "url": "https://lemonergy.com/learn/glossary/charge-acceptance/",
        "mentions": [
          "state-of-charge"
        ]
      }
    },
    {
      "id": "term:precharge-recharge",
      "type": "Term",
      "label": "Low-voltage precharge and automatic recharge",
      "properties": {
        "id": "precharge-recharge",
        "name": "Low-voltage precharge and automatic recharge",
        "section": "topic-charging",
        "definition": "A compatible charging controller can start eligible low-voltage cells at reduced current and later enter normal charging. Automatic recharge is a separate restart after the battery falls below a defined threshold following termination.",
        "related": [
          "cc-cv-charging",
          "cutoff-voltage",
          "boost-charging",
          "charging-strategies"
        ],
        "example": {
          "title": "Worked example",
          "text": "Read the low-current opening stage and the zero-current interval after termination as different states. The next ordinary charging stage starts only after the fictional restart condition is met."
        },
        "url": "https://lemonergy.com/learn/glossary/precharge-recharge/",
        "mentions": []
      }
    },
    {
      "id": "term:target-soc-charging",
      "type": "Term",
      "label": "Target state-of-charge charging",
      "properties": {
        "id": "target-soc-charging",
        "name": "Target state-of-charge charging",
        "section": "topic-charging",
        "definition": "A target state of charge ends an ordinary charge session when the estimated charge fraction reaches the requested goal. It is a session policy layered over a compatible electrical charging profile.",
        "related": [
          "state-of-charge",
          "cc-cv-charging",
          "scheduled-charging",
          "charging-strategies"
        ],
        "example": {
          "title": "Worked example",
          "text": "Compare two sessions beginning at the same state of charge and selecting different session targets. The earlier stop reduces the requested charge, while voltage and temperature supervision remain separate."
        },
        "url": "https://lemonergy.com/learn/glossary/target-soc-charging/",
        "mentions": []
      }
    },
    {
      "id": "term:boost-charging",
      "type": "Term",
      "label": "Boost and top-up charging",
      "properties": {
        "id": "boost-charging",
        "name": "Boost and top-up charging",
        "section": "topic-charging",
        "definition": "A short, partial charge to add range quickly — often only into the part of the SOC window where the cell accepts high current best, typically 10–80 %. Charging above 80 % is slow on any fast charger, so frequent short top-ups are often faster than one long session.",
        "related": [
          "charging-curve",
          "fast-charging",
          "opportunity-charging",
          "usable-capacity",
          "charging-strategies"
        ],
        "url": "https://lemonergy.com/learn/glossary/boost-charging/",
        "mentions": [
          "charger",
          "state-of-charge"
        ]
      }
    },
    {
      "id": "term:trickle-charge",
      "type": "Term",
      "label": "Trickle charging",
      "properties": {
        "id": "trickle-charge",
        "name": "Trickle charging",
        "aka": [
          "float charge",
          "float charging",
          "trickle charge",
          "Trickle and float charging"
        ],
        "section": "topic-charging",
        "definition": "Trickle charging supplies a small maintenance current for chemistries and cells approved for it. Float charging instead regulates standby voltage. Applying continuous trickle current to ordinary lithium-ion cells is unsuitable.",
        "related": [
          "lead-acid",
          "overcharge",
          "calendar-aging",
          "slow-charging",
          "oxygen-recombination",
          "charging-strategies"
        ],
        "url": "https://lemonergy.com/learn/glossary/trickle-charge/",
        "mentions": [
          "float-charging"
        ]
      }
    },
    {
      "id": "term:float-charging",
      "type": "Term",
      "label": "Float charging",
      "properties": {
        "id": "float-charging",
        "name": "Float charging",
        "section": "topic-charging",
        "definition": "Float charging holds a specified standby voltage to offset self-discharge in batteries designed for continuous maintenance. This differs from applying a fixed trickle current or periodically restarting a charger.",
        "related": [
          "trickle-charge",
          "lead-acid",
          "lead-acid-bulk-absorption-float",
          "charging-strategies"
        ],
        "example": {
          "title": "Worked example",
          "text": "A standby charger holds its float voltage as the maintenance current falls. If a standby load changes, supply current may also change while the voltage control target stays the same."
        },
        "url": "https://lemonergy.com/learn/glossary/float-charging/",
        "mentions": [
          "self-discharge",
          "charger"
        ]
      }
    },
    {
      "id": "term:lead-acid-bulk-absorption-float",
      "type": "Term",
      "label": "Lead–acid bulk, absorption and float charging",
      "properties": {
        "id": "lead-acid-bulk-absorption-float",
        "name": "Lead–acid bulk, absorption and float charging",
        "section": "topic-charging",
        "definition": "A common lead–acid charging sequence uses current-limited bulk charge, a regulated absorption voltage with tapering current, and a lower float voltage for standby service. Product specifications determine whether and how each stage is used.",
        "related": [
          "lead-acid",
          "trickle-charge",
          "equalization-charge",
          "float-charging",
          "charging-strategies"
        ],
        "example": {
          "title": "Worked example",
          "text": "On a relative voltage plot, identify the higher absorption plateau before the lower float plateau. At the same standby voltage, maintenance current can vary with conditions and battery state."
        },
        "url": "https://lemonergy.com/learn/glossary/lead-acid-bulk-absorption-float/",
        "mentions": []
      }
    },
    {
      "id": "term:equalization-charge",
      "type": "Term",
      "label": "Equalization charge",
      "properties": {
        "id": "equalization-charge",
        "name": "Equalization charge",
        "section": "topic-charging",
        "definition": "A deliberate, controlled overcharge of a lead–acid battery that brings weaker cells up to full and stirs the electrolyte. It must never be applied to lithium-ion cells, which are equalised electronically by the BMS instead.",
        "related": [
          "lead-acid",
          "cell-balancing",
          "overcharge",
          "trickle-charge",
          "charging-strategies"
        ],
        "url": "https://lemonergy.com/learn/glossary/equalization-charge/",
        "mentions": [
          "electrolyte",
          "bms"
        ]
      }
    },
    {
      "id": "term:nickel-peak-termination",
      "type": "Term",
      "label": "Nickel battery peak-voltage and thermal termination",
      "properties": {
        "id": "nickel-peak-termination",
        "name": "Nickel battery peak-voltage and thermal termination",
        "section": "topic-charging",
        "definition": "A compatible nickel battery charger can terminate a current-controlled stage by detecting a voltage peak or subsequent drop. Temperature, temperature-rise rate or elapsed time can provide independent termination constraints, depending on the cell and charger.",
        "related": [
          "nickel-metal-hydride",
          "constant-current",
          "trickle-charge",
          "thermocouples-rtds",
          "charging-strategies"
        ],
        "example": {
          "title": "Worked example",
          "text": "A filtered fictional voltage trace climbs, flattens, then dips. A separate temperature trace keeps rising. The two signals illustrate different termination cues, whose thresholds and availability depend on the approved charger."
        },
        "url": "https://lemonergy.com/learn/glossary/nickel-peak-termination/",
        "mentions": [
          "charger"
        ]
      }
    },
    {
      "id": "term:iu-charging-characteristics",
      "type": "Term",
      "label": "IU, IUoU and IUI charging",
      "properties": {
        "id": "iu-charging-characteristics",
        "name": "IU, IUoU and IUI charging",
        "aka": [
          "IUoU",
          "IUI",
          "IUIa",
          "three-stage charging",
          "W characteristic",
          "DIN 41772"
        ],
        "section": "topic-charging",
        "definition": "The letter code, set out in DIN 41772, for a charger’s profile: I for a constant-current stage, U for constant voltage and W for current that falls as voltage rises. IUoU charges lead–acid at constant current, then at a raised voltage, then at a lower float voltage; IUI ends with a small constant current that finishes flooded traction cells and stirs their acid by gassing.",
        "related": [
          "lead-acid",
          "cc-cv-charging",
          "trickle-charge",
          "equalization-charge",
          "flooded-lead-acid"
        ],
        "url": "https://lemonergy.com/learn/glossary/iu-charging-characteristics/",
        "mentions": [
          "constant-current",
          "constant-voltage",
          "charger",
          "gas-generation"
        ]
      }
    },
    {
      "id": "term:negative-delta-v",
      "type": "Term",
      "label": "Negative delta V",
      "properties": {
        "id": "negative-delta-v",
        "name": "Negative delta V",
        "abbr": "−ΔV",
        "aka": [
          "-dV",
          "-dV/dt",
          "NDV",
          "minus delta V",
          "zero delta V",
          "peak voltage detection"
        ],
        "section": "topic-charging",
        "definition": "Negative delta V is a small decline in nickel battery voltage after its charging peak. Some compatible chargers detect it as a termination cue. Detectability depends on chemistry, current, temperature and filtering.",
        "related": [
          "charge-termination",
          "dt-dt-termination",
          "nickel-cadmium",
          "nickel-metal-hydride",
          "fast-charging"
        ],
        "url": "https://lemonergy.com/learn/glossary/negative-delta-v/",
        "mentions": []
      }
    },
    {
      "id": "term:dt-dt-termination",
      "type": "Term",
      "label": "dT/dt termination",
      "properties": {
        "id": "dt-dt-termination",
        "name": "dT/dt termination",
        "aka": [
          "ΔT/Δt termination",
          "temperature-rise termination",
          "rate-of-temperature-rise termination"
        ],
        "section": "topic-charging",
        "definition": "A temperature-rise-rate criterion ends nickel battery charging when the measured temperature slope reaches the approved condition. Sensor placement, filtering and independent supervision affect how the charger interprets the cue.",
        "related": [
          "charge-termination",
          "negative-delta-v",
          "temperature-sensor",
          "nickel-metal-hydride",
          "oxygen-recombination"
        ],
        "url": "https://lemonergy.com/learn/glossary/dt-dt-termination/",
        "mentions": [
          "charger"
        ]
      }
    },
    {
      "id": "term:charge-termination",
      "type": "Term",
      "label": "Charge termination",
      "properties": {
        "id": "charge-termination",
        "name": "Charge termination",
        "aka": [
          "end-of-charge detection",
          "full-charge detection"
        ],
        "section": "topic-charging",
        "definition": "Charge termination is the decision to end a charging stage or session. A controller can monitor taper current, voltage trend, temperature or time, or use a state-of-charge target, depending on the approved charging method.",
        "related": [
          "taper-current",
          "negative-delta-v",
          "dt-dt-termination",
          "cc-cv-charging",
          "trickle-charge"
        ],
        "url": "https://lemonergy.com/learn/glossary/charge-termination/",
        "mentions": []
      }
    },
    {
      "id": "term:refresh-charge",
      "type": "Term",
      "label": "Refresh charge",
      "properties": {
        "id": "refresh-charge",
        "name": "Refresh charge",
        "aka": [
          "topping charge",
          "storage recharge",
          "freshening charge"
        ],
        "section": "topic-charging",
        "definition": "A refresh charge restores charge lost during storage. The appropriate timing, stopping point and storage state depend on the battery chemistry, environment and manufacturer instructions.",
        "related": [
          "self-discharge",
          "storage-soc",
          "lead-acid",
          "trickle-charge",
          "lsd-nimh"
        ],
        "url": "https://lemonergy.com/learn/glossary/refresh-charge/",
        "mentions": []
      }
    },
    {
      "id": "term:reconditioning",
      "type": "Term",
      "label": "Reconditioning",
      "properties": {
        "id": "reconditioning",
        "name": "Reconditioning",
        "aka": [
          "exercise cycling",
          "conditioning cycle",
          "deep-discharge refresh"
        ],
        "section": "topic-charging",
        "definition": "Battery reconditioning is a manufacturer-defined service process that may use controlled discharge and recharge to address some forms of reversible capacity loss in eligible nickel batteries. Its applicability depends on product condition and chemistry.",
        "related": [
          "memory-effect",
          "nickel-cadmium",
          "nickel-metal-hydride",
          "over-discharge"
        ],
        "url": "https://lemonergy.com/learn/glossary/reconditioning/",
        "mentions": []
      }
    },
    {
      "id": "term:smart-charging",
      "type": "Term",
      "label": "Smart charging",
      "properties": {
        "id": "smart-charging",
        "name": "Smart charging",
        "aka": [
          "managed charging",
          "load management"
        ],
        "section": "topic-infrastructure",
        "definition": "Controlling when and how fast vehicles charge to fit grid capacity, electricity prices and departure times, rather than charging at full power on arrival. A depot of buses uses it to stay within its grid connection; homes use it to charge on cheap night tariffs.",
        "related": [
          "depot-charging",
          "ocpp",
          "energy-management-system",
          "vehicle-to-grid",
          "iso-15118",
          "charging-strategies"
        ],
        "url": "https://lemonergy.com/learn/glossary/smart-charging/",
        "mentions": []
      }
    },
    {
      "id": "term:scheduled-charging",
      "type": "Term",
      "label": "Scheduled and managed charging",
      "properties": {
        "id": "scheduled-charging",
        "name": "Scheduled and managed charging",
        "section": "topic-charging",
        "definition": "Scheduled charging chooses when charging begins or pauses, while managed charging may also set a power budget across several vehicles or storage units. The battery still enforces its local current and voltage limits.",
        "related": [
          "smart-charging",
          "depot-charging",
          "opportunity-charging",
          "charge-acceptance",
          "charging-strategies"
        ],
        "example": {
          "title": "Worked example",
          "text": "Two vehicles share a fictional site budget. Delay part of the demand to a later window and compare the peak site power, keeping vehicle limits separate from the site allocation."
        },
        "url": "https://lemonergy.com/learn/glossary/scheduled-charging/",
        "mentions": []
      }
    },
    {
      "id": "term:depot-charging",
      "type": "Term",
      "label": "Depot charging",
      "properties": {
        "id": "depot-charging",
        "name": "Depot charging",
        "aka": [
          "overnight charging"
        ],
        "section": "topic-infrastructure",
        "definition": "Charging a fleet of buses or trucks at the depot, usually overnight at 50–150 kW per vehicle, which keeps cell stress low and lets an energy-management system sequence the chargers against the site’s grid connection.",
        "related": [
          "electric-bus",
          "pantograph-charging",
          "energy-management-system",
          "vdv-261",
          "fast-charging",
          "smart-charging"
        ],
        "url": "https://lemonergy.com/learn/glossary/depot-charging/",
        "mentions": []
      }
    },
    {
      "id": "term:opportunity-charging",
      "type": "Term",
      "label": "Opportunity charging",
      "properties": {
        "id": "opportunity-charging",
        "name": "Opportunity charging",
        "aka": [
          "en-route charging",
          "terminus charging"
        ],
        "section": "topic-infrastructure",
        "definition": "Topping up a vehicle in short, high-power bursts wherever it stops anyway — a bus at its terminus or at stops, a forklift at breaks — instead of carrying enough energy for the whole day. It allows a smaller, lighter battery, at the price of frequent high-rate cycling and of chargers along the route.",
        "related": [
          "pantograph-charging",
          "depot-charging",
          "fast-charging",
          "electric-bus",
          "charge-acceptance",
          "inductive-charging"
        ],
        "url": "https://lemonergy.com/learn/glossary/opportunity-charging/",
        "mentions": []
      }
    },
    {
      "id": "term:split-pack-charging",
      "type": "Term",
      "label": "Split-pack charging",
      "properties": {
        "id": "split-pack-charging",
        "name": "Split-pack charging",
        "aka": [
          "bank charging",
          "pack splitting",
          "series–parallel switching"
        ],
        "section": "topic-charging",
        "definition": "Reconfiguring a pack with contactors so that its two halves charge in parallel at half the drive voltage. An 800 V vehicle such as the Tesla Cybertruck can then use 400 V fast chargers without a DC/DC booster; GM’s Hummer EV does the reverse, driving at 400 V and switching the halves into series to charge at 800 V.",
        "related": [
          "pack-voltage",
          "contactor",
          "dc-fast-charging",
          "series-parallel",
          "dc-dc-converter",
          "hpc"
        ],
        "url": "https://lemonergy.com/learn/glossary/split-pack-charging/",
        "mentions": []
      }
    },
    {
      "id": "term:regenerative-braking",
      "type": "Term",
      "label": "Regenerative braking",
      "properties": {
        "id": "regenerative-braking",
        "name": "Regenerative braking",
        "section": "topic-charging",
        "definition": "Using a vehicle’s motor as a generator while slowing down, so braking energy charges the battery in short high-current pulses. A cold or full battery cannot accept it, which is one reason a BMS computes charge power limits continuously.",
        "related": [
          "state-of-power",
          "fast-charging",
          "electric-vehicle",
          "load-profile",
          "charging-strategies"
        ],
        "url": "https://lemonergy.com/learn/glossary/regenerative-braking/",
        "mentions": [
          "bms"
        ]
      }
    },
    {
      "id": "term:charger",
      "type": "Term",
      "label": "Charger",
      "properties": {
        "id": "charger",
        "name": "Charger",
        "section": "topic-charging",
        "definition": "The power electronics that convert mains or DC supply into the controlled current and voltage a battery needs. For lithium-ion it runs the CC-CV profile within the limits the BMS communicates, and stops rather than floats when the cell is full.",
        "related": [
          "cc-cv-charging",
          "bms",
          "onboard-charger",
          "dc-fast-charging"
        ],
        "url": "https://lemonergy.com/learn/glossary/charger/",
        "mentions": []
      }
    },
    {
      "id": "visual:charging-cccv",
      "type": "Visual",
      "label": "Compare charging profiles",
      "properties": {
        "title": "Compare charging profiles",
        "summary": "See which quantity is held constant, when the phase changes and how charging ends.",
        "readout": "Current holds at 5 A until the example 4.15 V threshold; voltage then holds while current tapers. The stop marker is a separate low-current termination condition.",
        "formula": "CC: I = I_set · CV: V = V_limit",
        "note": "Positive current charges the cell. Time is normalized; selected thresholds are not cell-specific recommendations. The voltage trace ends at termination; post-stop relaxation is excluded.",
        "software": {
          "status": "studio",
          "label": "Lemonergy Studio charging controller",
          "body": "The native controller regulates CC-CV charging. Its battery model uses charge balance, linear OCV and constant resistance. These authored profiles are explanatory, not its simulation output.",
          "href": "https://design.lemonergy.com/cosim.html?example=charging-home"
        },
        "html": "<figure class=\"visual-figure\"><figcaption>Current profile</figcaption><svg class=\"visual-chart\" viewBox=\"0 0 360 330\" role=\"img\" aria-labelledby=\"static-charging-cccv-0-title static-charging-cccv-0-desc\"><title id=\"static-charging-cccv-0-title\">Current profile</title><desc id=\"static-charging-cccv-0-desc\">Relative elapsed time versus Current (A). Charge current. Interpretation follows the graphs.</desc><rect x=\"74\" y=\"40\" width=\"155.44\" height=\"198\" fill=\"#2459a810\"/><text x=\"151.72\" y=\"60\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">CC</text><rect x=\"229.44\" y=\"40\" width=\"96.47999999999996\" height=\"198\" fill=\"#6953a810\"/><text x=\"277.67999999999995\" y=\"60\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">CV</text><rect x=\"325.91999999999996\" y=\"40\" width=\"16.08000000000004\" height=\"198\" fill=\"#2459a810\"/><text x=\"342\" y=\"28\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">Stop</text><path d=\"M74,238h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"242\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">0</text><text x=\"74\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0</text><path d=\"M74,188.5h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"192.5\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">1.44</text><text x=\"141\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0.25</text><path d=\"M74,139h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"143\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">2.88</text><text x=\"208\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0.5</text><path d=\"M74,89.5h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"93.5\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">4.31</text><text x=\"275\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0.75</text><path d=\"M74,40h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"44\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">5.75</text><text x=\"342\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">1</text><path d=\"M74,40v198h268\" fill=\"none\" stroke=\"currentColor\" opacity=\".3\"/><polyline fill=\"none\" stroke=\"#2459a8\" stroke-width=\"2.8\" points=\"74.00,65.83 74.54,65.83 75.07,65.83 75.61,65.83 76.14,65.83 76.68,65.83 77.22,65.83 77.75,65.83 78.29,65.83 78.82,65.83 79.36,65.83 79.90,65.83 80.43,65.83 80.97,65.83 81.50,65.83 82.04,65.83 82.58,65.83 83.11,65.83 83.65,65.83 84.18,65.83 84.72,65.83 85.26,65.83 85.79,65.83 86.33,65.83 86.86,65.83 87.40,65.83 87.94,65.83 88.47,65.83 89.01,65.83 89.54,65.83 90.08,65.83 90.62,65.83 91.15,65.83 91.69,65.83 92.22,65.83 92.76,65.83 93.30,65.83 93.83,65.83 94.37,65.83 94.90,65.83 95.44,65.83 95.98,65.83 96.51,65.83 97.05,65.83 97.58,65.83 98.12,65.83 98.66,65.83 99.19,65.83 99.73,65.83 100.26,65.83 100.80,65.83 101.34,65.83 101.87,65.83 102.41,65.83 102.94,65.83 103.48,65.83 104.02,65.83 104.55,65.83 105.09,65.83 105.62,65.83 106.16,65.83 106.70,65.83 107.23,65.83 107.77,65.83 108.30,65.83 108.84,65.83 109.38,65.83 109.91,65.83 110.45,65.83 110.98,65.83 111.52,65.83 112.06,65.83 112.59,65.83 113.13,65.83 113.66,65.83 114.20,65.83 114.74,65.83 115.27,65.83 115.81,65.83 116.34,65.83 116.88,65.83 117.42,65.83 117.95,65.83 118.49,65.83 119.02,65.83 119.56,65.83 120.10,65.83 120.63,65.83 121.17,65.83 121.70,65.83 122.24,65.83 122.78,65.83 123.31,65.83 123.85,65.83 124.38,65.83 124.92,65.83 125.46,65.83 125.99,65.83 126.53,65.83 127.06,65.83 127.60,65.83 128.14,65.83 128.67,65.83 129.21,65.83 129.74,65.83 130.28,65.83 130.82,65.83 131.35,65.83 131.89,65.83 132.42,65.83 132.96,65.83 133.50,65.83 134.03,65.83 134.57,65.83 135.10,65.83 135.64,65.83 136.18,65.83 136.71,65.83 137.25,65.83 137.78,65.83 138.32,65.83 138.86,65.83 139.39,65.83 139.93,65.83 140.46,65.83 141.00,65.83 141.54,65.83 142.07,65.83 142.61,65.83 143.14,65.83 143.68,65.83 144.22,65.83 144.75,65.83 145.29,65.83 145.82,65.83 146.36,65.83 146.90,65.83 147.43,65.83 147.97,65.83 148.50,65.83 149.04,65.83 149.58,65.83 150.11,65.83 150.65,65.83 151.18,65.83 151.72,65.83 152.26,65.83 152.79,65.83 153.33,65.83 153.86,65.83 154.40,65.83 154.94,65.83 155.47,65.83 156.01,65.83 156.54,65.83 157.08,65.83 157.62,65.83 158.15,65.83 158.69,65.83 159.22,65.83 159.76,65.83 160.30,65.83 160.83,65.83 161.37,65.83 161.90,65.83 162.44,65.83 162.98,65.83 163.51,65.83 164.05,65.83 164.58,65.83 165.12,65.83 165.66,65.83 166.19,65.83 166.73,65.83 167.26,65.83 167.80,65.83 168.34,65.83 168.87,65.83 169.41,65.83 169.94,65.83 170.48,65.83 171.02,65.83 171.55,65.83 172.09,65.83 172.62,65.83 173.16,65.83 173.70,65.83 174.23,65.83 174.77,65.83 175.30,65.83 175.84,65.83 176.38,65.83 176.91,65.83 177.45,65.83 177.98,65.83 178.52,65.83 179.06,65.83 179.59,65.83 180.13,65.83 180.66,65.83 181.20,65.83 181.74,65.83 182.27,65.83 182.81,65.83 183.34,65.83 183.88,65.83 184.42,65.83 184.95,65.83 185.49,65.83 186.02,65.83 186.56,65.83 187.10,65.83 187.63,65.83 188.17,65.83 188.70,65.83 189.24,65.83 189.78,65.83 190.31,65.83 190.85,65.83 191.38,65.83 191.92,65.83 192.46,65.83 192.99,65.83 193.53,65.83 194.06,65.83 194.60,65.83 195.14,65.83 195.67,65.83 196.21,65.83 196.74,65.83 197.28,65.83 197.82,65.83 198.35,65.83 198.89,65.83 199.42,65.83 199.96,65.83 200.50,65.83 201.03,65.83 201.57,65.83 202.10,65.83 202.64,65.83 203.18,65.83 203.71,65.83 204.25,65.83 204.78,65.83 205.32,65.83 205.86,65.83 206.39,65.83 206.93,65.83 207.46,65.83 208.00,65.83 208.54,65.83 209.07,65.83 209.61,65.83 210.14,65.83 210.68,65.83 211.22,65.83 211.75,65.83 212.29,65.83 212.82,65.83 213.36,65.83 213.90,65.83 214.43,65.83 214.97,65.83 215.50,65.83 216.04,65.83 216.58,65.83 217.11,65.83 217.65,65.83 218.18,65.83 218.72,65.83 219.26,65.83 219.79,65.83 220.33,65.83 220.86,65.83 221.40,65.83 221.94,65.83 222.47,65.83 223.01,65.83 223.54,65.83 224.08,65.83 224.62,65.83 225.15,65.83 225.69,65.83 226.22,65.83 226.76,65.83 227.30,65.83 227.83,65.83 228.37,65.83 228.90,65.83 229.44,65.83 229.98,68.67 230.51,71.47 231.05,74.22 231.58,76.93 232.12,79.59 232.66,82.21 233.19,84.79 233.73,87.32 234.26,89.81 234.80,92.26 235.34,94.67 235.87,97.04 236.41,99.37 236.94,101.66 237.48,103.91 238.02,106.13 238.55,108.31 239.09,110.45 239.62,112.56 240.16,114.63 240.70,116.67 241.23,118.68 241.77,120.65 242.30,122.59 242.84,124.50 243.38,126.37 243.91,128.22 244.45,130.03 244.98,131.82 245.52,133.57 246.06,135.30 246.59,136.99 247.13,138.66 247.66,140.31 248.20,141.92 248.74,143.51 249.27,145.07 249.81,146.61 250.34,148.12 250.88,149.60 251.42,151.06 251.95,152.50 252.49,153.91 253.02,155.30 253.56,156.67 254.10,158.02 254.63,159.34 255.17,160.64 255.70,161.92 256.24,163.17 256.78,164.41 257.31,165.63 257.85,166.82 258.38,168.00 258.92,169.16 259.46,170.29 259.99,171.41 260.53,172.51 261.06,173.60 261.60,174.66 262.14,175.71 262.67,176.74 263.21,177.75 263.74,178.75 264.28,179.73 264.82,180.69 265.35,181.64 265.89,182.57 266.42,183.48 266.96,184.38 267.50,185.27 268.03,186.14 268.57,187.00 269.10,187.84 269.64,188.67 270.18,189.49 270.71,190.29 271.25,191.08 271.78,191.85 272.32,192.62 272.86,193.37 273.39,194.10 273.93,194.83 274.46,195.54 275.00,196.24 275.54,196.93 276.07,197.61 276.61,198.28 277.14,198.94 277.68,199.58 278.22,200.22 278.75,200.84 279.29,201.46 279.82,202.06 280.36,202.65 280.90,203.24 281.43,203.81 281.97,204.38 282.50,204.93 283.04,205.48 283.58,206.02 284.11,206.55 284.65,207.07 285.18,207.58 285.72,208.08 286.26,208.58 286.79,209.06 287.33,209.54 287.86,210.01 288.40,210.47 288.94,210.93 289.47,211.38 290.01,211.82 290.54,212.25 291.08,212.67 291.62,213.09 292.15,213.50 292.69,213.91 293.22,214.31 293.76,214.70 294.30,215.08 294.83,215.46 295.37,215.84 295.90,216.20 296.44,216.56 296.98,216.92 297.51,217.26 298.05,217.61 298.58,217.94 299.12,218.28 299.66,218.60 300.19,218.92 300.73,219.24 301.26,219.55 301.80,219.85 302.34,220.15 302.87,220.45 303.41,220.74 303.94,221.02 304.48,221.30 305.02,221.58 305.55,221.85 306.09,222.12 306.62,222.38 307.16,222.64 307.70,222.89 308.23,223.14 308.77,223.39 309.30,223.63 309.84,223.87 310.38,224.10 310.91,224.33 311.45,224.56 311.98,224.78 312.52,225.00 313.06,225.21 313.59,225.42 314.13,225.63 314.66,225.84 315.20,226.04 315.74,226.23 316.27,226.43 316.81,226.62 317.34,226.81 317.88,226.99 318.42,227.18 318.95,227.35 319.49,227.53 320.02,227.70 320.56,227.87 321.10,228.04 321.63,228.21 322.17,228.37 322.70,228.53 323.24,228.68 323.78,228.84 324.31,228.99 324.85,229.14 325.38,229.28 325.92,238.00 326.46,238.00 326.99,238.00 327.53,238.00 328.06,238.00 328.60,238.00 329.14,238.00 329.67,238.00 330.21,238.00 330.74,238.00 331.28,238.00 331.82,238.00 332.35,238.00 332.89,238.00 333.42,238.00 333.96,238.00 334.50,238.00 335.03,238.00 335.57,238.00 336.10,238.00 336.64,238.00 337.18,238.00 337.71,238.00 338.25,238.00 338.78,238.00 339.32,238.00 339.86,238.00 340.39,238.00 340.93,238.00 341.46,238.00 342.00,238.00\"/><text transform=\"translate(208 303)\" text-anchor=\"middle\" font-size=\"14\" fill=\"currentColor\"><tspan x=\"0\" dy=\"0\">Relative elapsed time</tspan></text><text transform=\"translate(20 139) rotate(-90)\" text-anchor=\"middle\" font-size=\"14\" fill=\"currentColor\"><tspan x=\"0\" dy=\"0\">Current (A)</tspan></text></svg><div class=\"visual-legend\"><span><i style=\"background:#2459a8\"></i>Charge current</span></div></figure>\n<figure class=\"visual-figure\"><figcaption>Voltage profile</figcaption><svg class=\"visual-chart\" viewBox=\"0 0 360 330\" role=\"img\" aria-labelledby=\"static-charging-cccv-1-title static-charging-cccv-1-desc\"><title id=\"static-charging-cccv-1-title\">Voltage profile</title><desc id=\"static-charging-cccv-1-desc\">Relative elapsed time versus Cell voltage (V). Cell voltage. Interpretation follows the graphs.</desc><rect x=\"74\" y=\"40\" width=\"155.44\" height=\"198\" fill=\"#2459a810\"/><text x=\"151.72\" y=\"60\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">CC</text><rect x=\"229.44\" y=\"40\" width=\"96.47999999999996\" height=\"198\" fill=\"#6953a810\"/><text x=\"277.67999999999995\" y=\"60\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">CV</text><rect x=\"325.91999999999996\" y=\"40\" width=\"16.08000000000004\" height=\"198\" fill=\"#2459a810\"/><text x=\"342\" y=\"28\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">Stop</text><path d=\"M74,238h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"242\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">3</text><text x=\"74\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0</text><path d=\"M74,188.5h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"192.5\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">3.35</text><text x=\"141\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0.25</text><path d=\"M74,139h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"143\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">3.7</text><text x=\"208\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0.5</text><path d=\"M74,89.49999999999994h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"93.49999999999994\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">4.05</text><text x=\"275\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0.75</text><path d=\"M74,40h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"44\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">4.4</text><text x=\"342\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">1</text><path d=\"M74,40v198h268\" fill=\"none\" stroke=\"currentColor\" opacity=\".3\"/><polyline fill=\"none\" stroke=\"#6953a8\" stroke-width=\"2.8\" points=\"74.00,202.64 74.79,202.00 75.57,201.35 76.36,200.71 77.15,200.06 77.94,199.42 78.72,198.77 79.51,198.13 80.30,197.49 81.09,196.84 81.87,196.20 82.66,195.55 83.45,194.91 84.23,194.26 85.02,193.62 85.81,192.97 86.60,192.33 87.38,191.68 88.17,191.04 88.96,190.39 89.74,189.75 90.53,189.11 91.32,188.46 92.11,187.82 92.89,187.17 93.68,186.53 94.47,185.88 95.26,185.24 96.04,184.59 96.83,183.95 97.62,183.30 98.40,182.66 99.19,182.01 99.98,181.37 100.77,180.72 101.55,180.08 102.34,179.44 103.13,178.79 103.92,178.15 104.70,177.50 105.49,176.86 106.28,176.21 107.06,175.57 107.85,174.92 108.64,174.28 109.43,173.63 110.21,172.99 111.00,172.34 111.79,171.70 112.57,171.05 113.36,170.41 114.15,169.77 114.94,169.12 115.72,168.48 116.51,167.83 117.30,167.19 118.09,166.54 118.87,165.90 119.66,165.25 120.45,164.61 121.23,163.96 122.02,163.32 122.81,162.67 123.60,162.03 124.38,161.39 125.17,160.74 125.96,160.10 126.75,159.45 127.53,158.81 128.32,158.16 129.11,157.52 129.89,156.87 130.68,156.23 131.47,155.58 132.26,154.94 133.04,154.29 133.83,153.65 134.62,153.00 135.40,152.36 136.19,151.72 136.98,151.07 137.77,150.43 138.55,149.78 139.34,149.14 140.13,148.49 140.92,147.85 141.70,147.20 142.49,146.56 143.28,145.91 144.06,145.27 144.85,144.62 145.64,143.98 146.43,143.33 147.21,142.69 148.00,142.05 148.79,141.40 149.58,140.76 150.36,140.11 151.15,139.47 151.94,138.82 152.72,138.18 153.51,137.53 154.30,136.89 155.09,136.24 155.87,135.60 156.66,134.95 157.45,134.31 158.23,133.67 159.02,133.02 159.81,132.38 160.60,131.73 161.38,131.09 162.17,130.44 162.96,129.80 163.75,129.15 164.53,128.51 165.32,127.86 166.11,127.22 166.89,126.57 167.68,125.93 168.47,125.28 169.26,124.64 170.04,124.00 170.83,123.35 171.62,122.71 172.41,122.06 173.19,121.42 173.98,120.77 174.77,120.13 175.55,119.48 176.34,118.84 177.13,118.19 177.92,117.55 178.70,116.90 179.49,116.26 180.28,115.61 181.06,114.97 181.85,114.33 182.64,113.68 183.43,113.04 184.21,112.39 185.00,111.75 185.79,111.10 186.58,110.46 187.36,109.81 188.15,109.17 188.94,108.52 189.72,107.88 190.51,107.23 191.30,106.59 192.09,105.95 192.87,105.30 193.66,104.66 194.45,104.01 195.24,103.37 196.02,102.72 196.81,102.08 197.60,101.43 198.38,100.79 199.17,100.14 199.96,99.50 200.75,98.85 201.53,98.21 202.32,97.56 203.11,96.92 203.89,96.28 204.68,95.63 205.47,94.99 206.26,94.34 207.04,93.70 207.83,93.05 208.62,92.41 209.41,91.76 210.19,91.12 210.98,90.47 211.77,89.83 212.55,89.18 213.34,88.54 214.13,87.89 214.92,87.25 215.70,86.61 216.49,85.96 217.28,85.32 218.07,84.67 218.85,84.03 219.64,83.38 220.43,82.74 221.21,82.09 222.00,81.45 222.79,80.80 223.58,80.16 224.36,79.51 225.15,78.87 225.94,78.23 226.72,77.58 227.51,76.94 228.30,76.29 229.09,75.65 229.87,75.36 230.66,75.36 231.45,75.36 232.24,75.36 233.02,75.36 233.81,75.36 234.60,75.36 235.38,75.36 236.17,75.36 236.96,75.36 237.75,75.36 238.53,75.36 239.32,75.36 240.11,75.36 240.90,75.36 241.68,75.36 242.47,75.36 243.26,75.36 244.04,75.36 244.83,75.36 245.62,75.36 246.41,75.36 247.19,75.36 247.98,75.36 248.77,75.36 249.55,75.36 250.34,75.36 251.13,75.36 251.92,75.36 252.70,75.36 253.49,75.36 254.28,75.36 255.07,75.36 255.85,75.36 256.64,75.36 257.43,75.36 258.21,75.36 259.00,75.36 259.79,75.36 260.58,75.36 261.36,75.36 262.15,75.36 262.94,75.36 263.73,75.36 264.51,75.36 265.30,75.36 266.09,75.36 266.87,75.36 267.66,75.36 268.45,75.36 269.24,75.36 270.02,75.36 270.81,75.36 271.60,75.36 272.38,75.36 273.17,75.36 273.96,75.36 274.75,75.36 275.53,75.36 276.32,75.36 277.11,75.36 277.90,75.36 278.68,75.36 279.47,75.36 280.26,75.36 281.04,75.36 281.83,75.36 282.62,75.36 283.41,75.36 284.19,75.36 284.98,75.36 285.77,75.36 286.56,75.36 287.34,75.36 288.13,75.36 288.92,75.36 289.70,75.36 290.49,75.36 291.28,75.36 292.07,75.36 292.85,75.36 293.64,75.36 294.43,75.36 295.21,75.36 296.00,75.36 296.79,75.36 297.58,75.36 298.36,75.36 299.15,75.36 299.94,75.36 300.73,75.36 301.51,75.36 302.30,75.36 303.09,75.36 303.87,75.36 304.66,75.36 305.45,75.36 306.24,75.36 307.02,75.36 307.81,75.36 308.60,75.36 309.39,75.36 310.17,75.36 310.96,75.36 311.75,75.36 312.53,75.36 313.32,75.36 314.11,75.36 314.90,75.36 315.68,75.36 316.47,75.36 317.26,75.36 318.04,75.36 318.83,75.36 319.62,75.36 320.41,75.36 321.19,75.36 321.98,75.36 322.77,75.36 323.56,75.36 324.34,75.36 325.13,75.36 325.92,75.36\"/><text transform=\"translate(208 303)\" text-anchor=\"middle\" font-size=\"14\" fill=\"currentColor\"><tspan x=\"0\" dy=\"0\">Relative elapsed time</tspan></text><text transform=\"translate(20 139) rotate(-90)\" text-anchor=\"middle\" font-size=\"14\" fill=\"currentColor\"><tspan x=\"0\" dy=\"0\">Cell voltage (V)</tspan></text></svg><div class=\"visual-legend\"><span><i style=\"background:#6953a8\"></i>Cell voltage</span></div></figure>"
      }
    },
    {
      "id": "reference:tomaszewska-charging",
      "type": "Reference",
      "label": "Lithium-ion battery fast charging: A review",
      "properties": {
        "title": "Lithium-ion battery fast charging: A review",
        "publisher": "eTransportation",
        "url": "https://doi.org/10.1016/j.etran.2019.100011",
        "type": "Review article",
        "scope": "CC-CV and alternative charging protocols, transport limitations, degradation and thermal implications; results depend on cell and test conditions. Software behavior is documented separately in Lemonergy block references.",
        "year": 2019,
        "authors": [
          "Anna Tomaszewska et al."
        ],
        "accessed": "2026-10-27"
      }
    },
    {
      "id": "reference:attia-charge",
      "type": "Reference",
      "label": "Closed-loop optimization of fast-charging protocols for batteries with machine learning",
      "properties": {
        "title": "Closed-loop optimization of fast-charging protocols for batteries with machine learning",
        "publisher": "Nature",
        "url": "https://www.nature.com/articles/s41586-020-1994-5",
        "type": "Primary research",
        "scope": "Experimental selection of multistep lithium-ion charging profiles. Figure shape and settings here are independently authored.",
        "accessed": "2026-11-18"
      }
    },
    {
      "id": "reference:shin-pulse-charge",
      "type": "Reference",
      "label": "Insight into pulse-charging for lithium plating-free fast-charging lithium-ion batteries",
      "properties": {
        "title": "Insight into pulse-charging for lithium plating-free fast-charging lithium-ion batteries",
        "publisher": "Electrochimica Acta",
        "url": "https://www.sciencedirect.com/science/article/pii/S0013468623009386",
        "type": "Primary research",
        "scope": "Experimental and modeling study of pulse charging and lithium plating under the study conditions.",
        "accessed": "2026-11-20"
      }
    }
  ]
}