Constant-power charging
Constant-power charging regulates the product of terminal voltage and current. As terminal voltage rises, current falls until another limit takes priority or the session ends. [1]
In the guides: Battery charging strategies
Example
Worked example
At an illustrative 12 W, current is 4 A when the terminal voltage is 3 V and 3 A when it is 4 V. The arithmetic does not set a cell limit.
Explore the graph
Compare voltage, current and power on one elapsed-time basis.
At 3 V, current is 4 A; at 4 V, it is 3 A. Power stays at 12 W.
I = P/V
Illustrative model. Original normalized teaching traces. They omit cell calibration and do not specify charger settings or predict charge time, aging or safety.
Use in Lemonergy
Design protocol or analysis tool
Program constant power
Positive power magnitude and explicit direction define CP.
Equation or tool to use
- Charge at constant power
Programs power
Inputs & settings
- mode: cp
- w / s
This overview identifies the components to use. Follow the example in Lemonergy for their connections and settings.
Example. 2 kW at 100 V implies 20 A; at 120 V it implies about 16.7 A.
Observe. Current follows I = P/V.
This is CP only, not a combined CP–CV controller. CC and CP cannot share a protocol.