Capacity test

A defined capacity test with specified charge, rest, discharge and cutoff conditions, usually a full CC-CV charge, a rest, and a C/3 or lower discharge to the lower cutoff at 25 °C. The delivered ampere-hours are the cell’s measured capacity. [1] [2]

Example

C-rate, current and duration

5 Ah × 1C = 5 A. Ideal duration: 1 h (60 min).

Voltage cutoff, losses, temperature and rate-dependent capacity are excluded.

Explore the graph

A C-rate becomes an actual current only when capacity is known.

Ideal remaining charge
Ideal remaining chargeTime (h) versus Remaining charge (Ah). 1C. Interpretation follows the graphs.001.2512.523.75354Time (h)Remaining charge (Ah)
1C

5 Ah × 1C = 5 A. Ideal duration: 1 h (60 min).

I = Q × C-rate; t_ideal = 1 / C-rate

Illustrative model. Voltage cutoff, losses, temperature and rate-dependent capacity are excluded.

Use in Lemonergy

Record specimen, state, instrument, temperature and timing.

This is a reference concept. No executable Lemonergy block has been verified for this term.

Learn it in Lesson 2 · Capacity and C-rate →