Battery knowledge · Testing methods
Capacity test
A defined capacity test with specified charge, rest, discharge and cutoff conditions, usually a full CC-CV charge, a rest, and a C/3 or lower discharge to the lower cutoff at 25 °C. The delivered ampere-hours are the cell’s measured capacity. [1] [2]
Example
C-rate, current and duration
5 Ah × 1C = 5 A. Ideal duration: 1 h (60 min).
Voltage cutoff, losses, temperature and rate-dependent capacity are excluded.
Explore the graph
A C-rate becomes an actual current only when capacity is known.
5 Ah × 1C = 5 A. Ideal duration: 1 h (60 min).
I = Q × C-rate; t_ideal = 1 / C-rate
Illustrative model. Voltage cutoff, losses, temperature and rate-dependent capacity are excluded.
Use in Lemonergy
Record specimen, state, instrument, temperature and timing.
This is a reference concept. No executable Lemonergy block has been verified for this term.
References & further reading
Technical references
- Battery Test Manual For Electric Vehicles, Revision 3
Jon P. Christopherson · Idaho National Laboratory · 2015
Technical reference · Performance characterization, pulse resistance/power, life testing and reference performance tests; historical 2015 edition.
- DOE Energy Storage Handbook, Chapter 16: Energy Storage Performance Testing
Sandia National Laboratories
Technical reference · Section 2.1.2.1 explains capacity, C-rate and the distinction between capacity and energy; also covers pulse characterization.