Battery knowledge · Capacity, energy, power and ratings

Nominal capacity

The charge a cell is rated to deliver under specified test conditions — current, temperature, rest and voltage limits — usually in ampere-hours. [1] [2]

Also called
rated capacity
Unit
Ah

Example

C-rate, current and duration

5 Ah × 1C = 5 A. Ideal duration: 1 h (60 min).

Voltage cutoff, losses, temperature and rate-dependent capacity are excluded.

Explore the graph

A C-rate becomes an actual current only when capacity is known.

Ideal remaining charge
Ideal remaining chargeTime (h) versus Remaining charge (Ah). 1C. Interpretation follows the graphs.001.2512.523.75354Time (h)Remaining charge (Ah)
1C

5 Ah × 1C = 5 A. Ideal duration: 1 h (60 min).

I = Q × C-rate; t_ideal = 1 / C-rate

Illustrative model. Voltage cutoff, losses, temperature and rate-dependent capacity are excluded.

Use in Lemonergy

Lemonergy Core equation

Convert C-rate into current

Lemonergy Core evaluates this relation.

Equation or tool to use

  1. current_from_c_rate

    Core equation

    Inputs & settings
    • Capacity (Ah)
    • C-rate (1/h)

This overview identifies the components to use. Follow the example in Lemonergy for their connections and settings.

  1. Open the lesson and inspect the equation.
  2. Change one input while holding the others fixed.

Example. A 5 Ah cell at 0.5C corresponds to 2.5 A. At 2C it corresponds to 10 A.

Observe. Compare the result with the equation and units.

Current magnitudes do not establish safe charge rates.

Open the worked lesson →

Learn it in Lesson 2 · Capacity and C-rate →

References & further reading

Technical references

  1. Battery Test Manual For Electric Vehicles, Revision 3

    Jon P. Christopherson · Idaho National Laboratory · 2015

    Technical reference · Performance characterization, pulse resistance/power, life testing and reference performance tests; historical 2015 edition.

  2. DOE Energy Storage Handbook, Chapter 16: Energy Storage Performance Testing

    Sandia National Laboratories

    Technical reference · Section 2.1.2.1 explains capacity, C-rate and the distinction between capacity and energy; also covers pulse characterization.

Further reading on this topic

These sources provide broader context; they are not presented as citations for every statement in this entry.

  1. The International System of Units (SI), 9th edition

    Bureau International des Poids et Mesures · 2026

    Topic background · Definitions of SI units and coherent derived units; 2026 revision.