  "node": {
    "id": "term:capacity-test",
    "type": "Term",
    "label": "Capacity test",
    "properties": {
      "id": "capacity-test",
      "name": "Capacity test",
      "section": "topic-testing",
      "definition": "A defined capacity test with specified charge, rest, discharge and cutoff conditions, usually a full CC-CV charge, a rest, and a C/3 or lower discharge to the lower cutoff at 25 °C. The delivered ampere-hours are the cell’s measured capacity.",
      "related": [
        "nominal-capacity",
        "cc-cv-charging",
        "cutoff-voltage",
        "reference-performance-test",
        "rate-test"
      ],
      "lesson": "fundamentals/capacity-and-c-rate/#nominal-capacity",
      "url": "https://lemonergy.com/learn/glossary/capacity-test/",
      "mentions": []
    }
  },
  "edges": [
    {
      "id": "edge:2605",
      "source": "term:capacity-test",
      "target": "topic:topic-testing",
      "type": "belongsTo",
      "properties": {
        "sourceFile": "terms.json"
      }
    },
    {
      "id": "edge:2606",
      "source": "term:capacity-test",
      "target": "term:nominal-capacity",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:2607",
      "source": "term:capacity-test",
      "target": "term:cc-cv-charging",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:2608",
      "source": "term:capacity-test",
      "target": "term:cutoff-voltage",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:2609",
      "source": "term:capacity-test",
      "target": "term:reference-performance-test",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:2610",
      "source": "term:capacity-test",
      "target": "term:rate-test",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:2611",
      "source": "term:capacity-test",
      "target": "lesson:fundamentals/capacity-and-c-rate/",
      "type": "explainedIn",
      "properties": {
        "sourceFile": "terms.json",
        "url": "https://lemonergy.com/learn/fundamentals/capacity-and-c-rate/#nominal-capacity"
      }
    },
    {
      "id": "edge:2612",
      "source": "term:capacity-test",
      "target": "visual:capacity",
      "type": "illustratedBy",
      "properties": {
        "sourceFile": "visual-pages.json"
      }
    },
    {
      "id": "edge:2613",
      "source": "term:capacity-test",
      "target": "reference:inl-ev-tests",
      "type": "cites",
      "properties": {
        "sourceFile": "wiki-references.json",
        "scope": "direct technical reference"
      }
    },
    {
      "id": "edge:2614",
      "source": "term:capacity-test",
      "target": "reference:sandia-performance",
      "type": "cites",
      "properties": {
        "sourceFile": "wiki-references.json",
        "scope": "direct technical reference"
      }
    }
  ],
  "neighbors": [
    {
      "id": "topic:topic-testing",
      "type": "Topic",
      "label": "Testing methods",
      "properties": {
        "id": "topic-testing",
        "name": "Testing methods",
        "lede": "The measurements and test procedures that characterise a cell or pack, from capacity and pulse tests to abuse and environmental tests.",
        "context": "Record specimen, state, instrument, temperature and timing.",
        "example": "Resistance immediately after a current step can differ from a ten-second value because slower polarization contributes.",
        "lesson_url": "https://lemonergy.com/learn/fundamentals/capacity-and-c-rate/",
        "lesson_label": "Open capacity measurements"
      }
    },
    {
      "id": "term:nominal-capacity",
      "type": "Term",
      "label": "Nominal capacity",
      "properties": {
        "id": "nominal-capacity",
        "name": "Nominal capacity",
        "aka": [
          "rated capacity"
        ],
        "section": "topic-ratings",
        "definition": "The charge a cell is rated to deliver under specified test conditions — current, temperature, rest and voltage limits — usually in ampere-hours.",
        "unit": "Ah",
        "related": [
          "ampere-hour",
          "c-rate",
          "capacity-test",
          "usable-capacity",
          "state-of-health"
        ],
        "lesson": "fundamentals/capacity-and-c-rate/#nominal-capacity",
        "url": "https://lemonergy.com/learn/glossary/nominal-capacity/",
        "mentions": []
      }
    },
    {
      "id": "term:cc-cv-charging",
      "type": "Term",
      "label": "CC-CV charging",
      "properties": {
        "id": "cc-cv-charging",
        "name": "CC-CV charging",
        "aka": [
          "constant current constant voltage"
        ],
        "section": "topic-charging",
        "definition": "The standard lithium-ion charge protocol: constant current until the cell reaches its upper cutoff voltage, then that voltage held constant while the current tapers. The charge ends when the current falls to a set fraction, often C/20.",
        "related": [
          "constant-current",
          "constant-voltage",
          "cutoff-voltage",
          "taper-current",
          "fast-charging",
          "cp-cv"
        ],
        "lesson": "fundamentals/capacity-and-c-rate/#real-cells",
        "example": {
          "title": "Follow a two-stage charge",
          "text": "For an illustrative 5 Ah cell, a 2.5 A current request is 0.5C. During CC the voltage rises. At the selected upper voltage, CV regulation holds voltage while current tapers. Completion requires the taper current to fall below the selected cutoff for the configured dwell."
        },
        "notes": [
          "Choose voltage, current and temperature limits from the actual cell specification. These example values do not define a charging recipe."
        ],
        "url": "https://lemonergy.com/learn/glossary/cc-cv-charging/",
        "mentions": []
      }
    },
    {
      "id": "term:cutoff-voltage",
      "type": "Term",
      "label": "Cutoff voltage",
      "properties": {
        "id": "cutoff-voltage",
        "name": "Cutoff voltage",
        "section": "topic-charging",
        "definition": "The terminal-voltage limit that ends a discharge, or caps a charge — in constant-current, constant-voltage (CC-CV) charging the cell is then held at that voltage until the current falls to a cutoff. A real discharge ends at the lower cutoff, which is why actual runtime can differ from the ideal duration.",
        "unit": "V",
        "related": [
          "voltage-window",
          "cc-cv-charging",
          "ideal-duration",
          "over-discharge",
          "overcharge"
        ],
        "lesson": "fundamentals/capacity-and-c-rate/#real-cells",
        "url": "https://lemonergy.com/learn/glossary/cutoff-voltage/",
        "mentions": [
          "service-life"
        ]
      }
    },
    {
      "id": "term:reference-performance-test",
      "type": "Term",
      "label": "Reference performance test",
      "properties": {
        "id": "reference-performance-test",
        "name": "Reference performance test",
        "abbr": "RPT",
        "aka": [
          "check-up"
        ],
        "section": "topic-testing",
        "definition": "A fixed set of measurements — capacity, resistance by pulse, sometimes impedance — repeated at intervals during an aging test to track state of health under identical conditions. Everything between RPTs is the aging itself.",
        "related": [
          "capacity-test",
          "hppc",
          "state-of-health",
          "accelerated-aging"
        ],
        "url": "https://lemonergy.com/learn/glossary/reference-performance-test/",
        "mentions": [
          "impedance"
        ]
      }
    },
    {
      "id": "term:rate-test",
      "type": "Term",
      "label": "Rate capability test",
      "properties": {
        "id": "rate-test",
        "name": "Rate capability test",
        "aka": [
          "C-rate test",
          "discharge rate test"
        ],
        "section": "topic-testing",
        "definition": "Discharging a cell at a series of rates — C/10, C/3, 1C, 2C, 3C — from a full charge and recording the capacity delivered at each. The result is the rate-capability curve on a datasheet and the first sign of a transport limitation.",
        "related": [
          "rate-capability",
          "c-rate",
          "capacity-test",
          "ideal-duration",
          "peukert"
        ],
        "url": "https://lemonergy.com/learn/glossary/rate-test/",
        "mentions": [
          "datasheet"
        ]
      }
    },
    {
      "id": "lesson:fundamentals/capacity-and-c-rate/",
      "type": "Lesson",
      "label": "Lesson 2 · Capacity and C-rate",
      "properties": {
        "url": "https://lemonergy.com/learn/fundamentals/capacity-and-c-rate/"
      }
    },
    {
      "id": "visual:capacity",
      "type": "Visual",
      "label": "C-rate, current and duration",
      "properties": {
        "title": "C-rate, current and duration",
        "summary": "A C-rate becomes an actual current only when capacity is known.",
        "readout": "5 Ah × 1C = 5 A. Ideal duration: 1 h (60 min).",
        "formula": "I = Q × C-rate; t_ideal = 1 / C-rate",
        "note": "Voltage cutoff, losses, temperature and rate-dependent capacity are excluded.",
        "software": {
          "status": "implemented",
          "label": "Implemented in battery-core",
          "body": "current_from_c_rate calculates I = Q × C-rate; ideal_duration_hours calculates 1 / C-rate. Neither predicts voltage-cutoff time or real usable capacity.",
          "href": "../fundamentals/capacity-and-c-rate/"
        },
        "html": "<figure class=\"visual-figure\"><figcaption>Ideal remaining charge</figcaption><svg class=\"visual-chart\" viewBox=\"0 0 360 330\" role=\"img\" aria-labelledby=\"static-capacity-0-title static-capacity-0-desc\"><title id=\"static-capacity-0-title\">Ideal remaining charge</title><desc id=\"static-capacity-0-desc\">Time (h) versus Remaining charge (Ah). 1C. Interpretation follows the graphs.</desc><path d=\"M74,238h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"242\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">0</text><text x=\"74\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0</text><path d=\"M74,188.5h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"192.5\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">1.25</text><text x=\"141\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">1</text><path d=\"M74,139h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"143\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">2.5</text><text x=\"208\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">2</text><path d=\"M74,89.5h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"93.5\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">3.75</text><text x=\"275\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">3</text><path d=\"M74,40h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"44\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">5</text><text x=\"342\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">4</text><path d=\"M74,40v198h268\" fill=\"none\" stroke=\"currentColor\" opacity=\".3\"/><polyline fill=\"none\" stroke=\"#2459a8\" stroke-width=\"2.8\" points=\"74.00,40.00 74.67,41.98 75.34,43.96 76.01,45.94 76.68,47.92 77.35,49.90 78.02,51.88 78.69,53.86 79.36,55.84 80.03,57.82 80.70,59.80 81.37,61.78 82.04,63.76 82.71,65.74 83.38,67.72 84.05,69.70 84.72,71.68 85.39,73.66 86.06,75.64 86.73,77.62 87.40,79.60 88.07,81.58 88.74,83.56 89.41,85.54 90.08,87.52 90.75,89.50 91.42,91.48 92.09,93.46 92.76,95.44 93.43,97.42 94.10,99.40 94.77,101.38 95.44,103.36 96.11,105.34 96.78,107.32 97.45,109.30 98.12,111.28 98.79,113.26 99.46,115.24 100.13,117.22 100.80,119.20 101.47,121.18 102.14,123.16 102.81,125.14 103.48,127.12 104.15,129.10 104.82,131.08 105.49,133.06 106.16,135.04 106.83,137.02 107.50,139.00 108.17,140.98 108.84,142.96 109.51,144.94 110.18,146.92 110.85,148.90 111.52,150.88 112.19,152.86 112.86,154.84 113.53,156.82 114.20,158.80 114.87,160.78 115.54,162.76 116.21,164.74 116.88,166.72 117.55,168.70 118.22,170.68 118.89,172.66 119.56,174.64 120.23,176.62 120.90,178.60 121.57,180.58 122.24,182.56 122.91,184.54 123.58,186.52 124.25,188.50 124.92,190.48 125.59,192.46 126.26,194.44 126.93,196.42 127.60,198.40 128.27,200.38 128.94,202.36 129.61,204.34 130.28,206.32 130.95,208.30 131.62,210.28 132.29,212.26 132.96,214.24 133.63,216.22 134.30,218.20 134.97,220.18 135.64,222.16 136.31,224.14 136.98,226.12 137.65,228.10 138.32,230.08 138.99,232.06 139.66,234.04 140.33,236.02 141.00,238.00\"/><text transform=\"translate(208 303)\" text-anchor=\"middle\" font-size=\"14\" fill=\"currentColor\"><tspan x=\"0\" dy=\"0\">Time (h)</tspan></text><text transform=\"translate(20 139) rotate(-90)\" text-anchor=\"middle\" font-size=\"14\" fill=\"currentColor\"><tspan x=\"0\" dy=\"0\">Remaining charge (Ah)</tspan></text></svg><div class=\"visual-legend\"><span><i style=\"background:#2459a8\"></i>1C</span></div></figure>"
      }
    },
    {
      "id": "reference:inl-ev-tests",
      "type": "Reference",
      "label": "Battery Test Manual For Electric Vehicles, Revision 3",
      "properties": {
        "title": "Battery Test Manual For Electric Vehicles, Revision 3",
        "publisher": "Idaho National Laboratory",
        "url": "https://inldigitallibrary.inl.gov/sites/sti/sti/6492291.pdf",
        "type": "Test manual",
        "scope": "Performance characterization, pulse resistance/power, life testing and reference performance tests; historical 2015 edition.",
        "year": 2015,
        "authors": [
          "Jon P. Christopherson"
        ],
        "accessed": "2026-10-27"
      }
    },
    {
      "id": "reference:sandia-performance",
      "type": "Reference",
      "label": "DOE Energy Storage Handbook, Chapter 16: Energy Storage Performance Testing",
      "properties": {
        "title": "DOE Energy Storage Handbook, Chapter 16: Energy Storage Performance Testing",
        "publisher": "Sandia National Laboratories",
        "url": "https://www.sandia.gov/app/uploads/sites/163/2021/09/ESHB_Ch16_Testing_Rosewater.pdf",
        "type": "Technical handbook chapter",
        "scope": "Section 2.1.2.1 explains capacity, C-rate and the distinction between capacity and energy; also covers pulse characterization.",
        "accessed": "2026-10-27"
      }
    }
  ]
}