Coolant pump
Adds a pressure rise that falls with flow along a pump curve and scales with the square of its speed. Drive power that does not become pressure warms the coolant.
- Implementation ID
liquid-pump- Reviewed
- 2026-10-30
Behavior
Adds a pressure rise that falls with flow along a pump curve and scales with the square of its speed. Drive power that does not become pressure warms the coolant.
Interface
| Name | Direction | Unit | Meaning |
|---|---|---|---|
a | conserving | thermal-liquid | Coolant side A |
b | conserving | thermal-liquid | Coolant side B |
Relative pump speed | input | fraction | Relative pump speed is a directed fraction input to this component, expressed in fraction. Its binding supplies information; it is not a conserving connection. |
mass Flow | output | kg/s | Directed output available to compatible consumers: mass Flow. |
outlet Temperature | output | K | Directed output available to compatible consumers: outlet Temperature. |
volume Flow | output | m³/s | Directed output available to compatible consumers: volume Flow. |
pressure Rise | output | Pa | Directed output available to compatible consumers: pressure Rise. |
power | output | W | Directed output available to compatible consumers: power. |
fluid Power | output | W | Directed output available to compatible consumers: fluid Power. |
loss | output | W | Directed output available to compatible consumers: loss. |
Signal inputs
These directed signals carry information. Conserving terminals exchange the quantities of their physical domain.
Signal outputs
Outputs can supply compatible inputs. Connections and values are inspected in the model that owns them.
| Pin | Direction | Unit or domain | Meaning |
|---|---|---|---|
| Relative pump speed | input | fraction | Relative pump speed is a directed fraction input to this component, expressed in fraction. Its binding supplies information; it is not a conserving connection. |
| mass Flow | output | kg/s | Directed output available to compatible consumers: mass Flow. |
| outlet Temperature | output | K | Directed output available to compatible consumers: outlet Temperature. |
| volume Flow | output | m³/s | Directed output available to compatible consumers: volume Flow. |
| pressure Rise | output | Pa | Directed output available to compatible consumers: pressure Rise. |
| power | output | W | Directed output available to compatible consumers: power. |
| fluid Power | output | W | Directed output available to compatible consumers: fluid Power. |
| loss | output | W | Directed output available to compatible consumers: loss. |
Parameters
Defaults are initial model values. Select values for your own model and operating conditions.
| Parameter | Unit | Default | Meaning and limits |
|---|---|---|---|
shutoffPressurePashutoffPressurePa | Pa | 50000 | Declared authoring field: shutoffPressurePa. Minimum 0; Maximum 100000000 |
linearResistancelinearResistance | Pa s/m3 | 1000000 | Declared authoring field: linearResistance. Minimum 1e-06; Maximum 1000000000000000 |
quadraticResistancequadraticResistance | Pa s2/m6 | 400000000000 | Declared authoring field: quadraticResistance. Minimum 0; Maximum 1000000000000000000 |
speedspeed | fraction | 1 | Declared authoring field: speed. Minimum 0; Maximum 2 |
efficiencyefficiency | fraction | 0.5 | Declared authoring field: efficiency. Minimum 0.001; Maximum 1 |
volumeM3volumeM3 | m3 | 0.0001 | Declared authoring field: volumeM3. Minimum 1e-07; Maximum 100 |
specificHeatJkgKspecificHeatJkgK | J/(kg K) | 4200 | Declared authoring field: specificHeatJkgK. Minimum 1; Maximum 1000000 |
densityKgM3densityKgM3 | kg/m3 | 1000 | Declared authoring field: densityKgM3. Minimum 1; Maximum 100000 |
initialTemperatureKinitialTemperatureK | K | 300 | Declared authoring field: initialTemperatureK. Minimum 0; Maximum 5000 |
Equations and rules
The behavior and configured interface above define this authoring component. This reference does not add numerical equations beyond its source contract.
Use in Studio
Use this authoring component
Choose this component in the Studio library and configure its declared interface. This reference describes the authoring contract; it does not claim a standalone numerical validation or a measured result.
Open Studio →Use in a workflow
Connected concepts
Limits and interpretation
- The symbolic diagram describes the component and its declared interface. It is not a solved circuit or simulated output.
- Configured parameters and model connections determine the result. Check the complete model before interpreting its outputs.
Implementation sources
This reference follows Lemonergy implementation sources. Scientific articles support the linked concepts separately.
Repository: battery-design · Revision: 88d14842e31549cb2004b41abdd64f29ac39ef9c
docs/glossary/studio-help-catalog.json
This implementation and its workflow uses (JSON) · Knowledge graph (JSON-LD)
Current authoring interface provenance
The interactive graphic is exported from the same Studio help descriptor. Source base: 88d14842e31549cb2004b41abdd64f29ac39ef9c. File content hashes in the public descriptor catalog identify the exact source snapshot. Existing numerical checks above retain their own verification scope.