  "node": {
    "id": "block:liquid-pump",
    "type": "Block",
    "label": "Coolant pump",
    "properties": {
      "id": "liquid-pump",
      "kind": "studio",
      "name": "Coolant pump",
      "summary": "Adds a pressure rise that falls with flow along a pump curve and scales with the square of its speed. Drive power that does not become pressure warms the coolant.",
      "behavior": "Adds a pressure rise that falls with flow along a pump curve and scales with the square of its speed. Drive power that does not become pressure warms the coolant.",
      "documentationSlug": "liquid-pump",
      "referenceOnly": true,
      "ports": [
        {
          "name": "a",
          "direction": "conserving",
          "unit": "thermal-liquid",
          "description": "Coolant side A"
        },
        {
          "name": "b",
          "direction": "conserving",
          "unit": "thermal-liquid",
          "description": "Coolant side B"
        },
        {
          "name": "Relative pump speed",
          "direction": "input",
          "unit": "fraction",
          "description": "Relative pump speed is a directed fraction input to this component, expressed in fraction. Its binding supplies information; it is not a conserving connection."
        },
        {
          "name": "mass Flow",
          "direction": "output",
          "unit": "kg/s",
          "description": "Directed output available to compatible consumers: mass Flow."
        },
        {
          "name": "outlet Temperature",
          "direction": "output",
          "unit": "K",
          "description": "Directed output available to compatible consumers: outlet Temperature."
        },
        {
          "name": "volume Flow",
          "direction": "output",
          "unit": "m³/s",
          "description": "Directed output available to compatible consumers: volume Flow."
        },
        {
          "name": "pressure Rise",
          "direction": "output",
          "unit": "Pa",
          "description": "Directed output available to compatible consumers: pressure Rise."
        },
        {
          "name": "power",
          "direction": "output",
          "unit": "W",
          "description": "Directed output available to compatible consumers: power."
        },
        {
          "name": "fluid Power",
          "direction": "output",
          "unit": "W",
          "description": "Directed output available to compatible consumers: fluid Power."
        },
        {
          "name": "loss",
          "direction": "output",
          "unit": "W",
          "description": "Directed output available to compatible consumers: loss."
        }
      ],
      "parameters": [
        {
          "key": "shutoffPressurePa",
          "label": "shutoffPressurePa",
          "unit": "Pa",
          "default": 50000,
          "description": "Declared authoring field: shutoffPressurePa.",
          "min": 0,
          "max": 100000000
        },
        {
          "key": "linearResistance",
          "label": "linearResistance",
          "unit": "Pa s/m3",
          "default": 1000000,
          "description": "Declared authoring field: linearResistance.",
          "min": 1e-06,
          "max": 1000000000000000
        },
        {
          "key": "quadraticResistance",
          "label": "quadraticResistance",
          "unit": "Pa s2/m6",
          "default": 400000000000,
          "description": "Declared authoring field: quadraticResistance.",
          "min": 0,
          "max": 1000000000000000000
        },
        {
          "key": "speed",
          "label": "speed",
          "unit": "fraction",
          "default": 1,
          "description": "Declared authoring field: speed.",
          "min": 0,
          "max": 2
        },
        {
          "key": "efficiency",
          "label": "efficiency",
          "unit": "fraction",
          "default": 0.5,
          "description": "Declared authoring field: efficiency.",
          "min": 0.001,
          "max": 1
        },
        {
          "key": "volumeM3",
          "label": "volumeM3",
          "unit": "m3",
          "default": 0.0001,
          "description": "Declared authoring field: volumeM3.",
          "min": 1e-07,
          "max": 100
        },
        {
          "key": "specificHeatJkgK",
          "label": "specificHeatJkgK",
          "unit": "J/(kg K)",
          "default": 4200,
          "description": "Declared authoring field: specificHeatJkgK.",
          "min": 1,
          "max": 1000000
        },
        {
          "key": "densityKgM3",
          "label": "densityKgM3",
          "unit": "kg/m3",
          "default": 1000,
          "description": "Declared authoring field: densityKgM3.",
          "min": 1,
          "max": 100000
        },
        {
          "key": "initialTemperatureK",
          "label": "initialTemperatureK",
          "unit": "K",
          "default": 300,
          "description": "Declared authoring field: initialTemperatureK.",
          "min": 0,
          "max": 5000
        }
      ],
      "equations": [],
      "example": {
        "title": "Use this authoring component",
        "text": "Choose this component in the Studio library and configure its declared interface. This reference describes the authoring contract; it does not claim a standalone numerical validation or a measured result.",
        "url": "https://design.lemonergy.com/cosim",
        "label": "Open Studio"
      },
      "limits": [
        "The symbolic diagram describes the component and its declared interface. It is not a solved circuit or simulated output.",
        "Configured parameters and model connections determine the result. Check the complete model before interpreting its outputs."
      ],
      "evidence": [
        "docs/glossary/studio-help-catalog.json"
      ],
      "caseIds": [],
      "sourceRepository": "battery-design",
      "sourceRevision": "88d14842e31549cb2004b41abdd64f29ac39ef9c",
      "reviewed": "2026-10-30",
      "type": "liquid-pump",
      "implementationId": "liquid-pump",
      "url": "https://lemonergy.com/learn/glossary/blocks/liquid-pump/",
      "documentationUrl": "https://lemonergy.com/learn/glossary/blocks/liquid-pump/",
      "sourceFile": "studio-help-catalog.json",
      "studioHelp": {
        "type": "liquid-pump",
        "namespace": "physical",
        "slug": "liquid-pump",
        "canonicalSlug": "liquid-pump",
        "existing": false,
        "dynamic": false,
        "scene": {
          "kind": "component",
          "componentId": "reference",
          "type": "liquid-pump",
          "name": "Coolant pump",
          "domain": "thermal-liquid",
          "family": "pump",
          "operation": "Adds a pressure rise that falls with flow along a pump curve and scales with the square of its speed. Drive power that does not become pressure warms the coolant.",
          "mechanism": [
            "Speed command",
            "Pump curve",
            "Coolant flow and power"
          ],
          "ports": [
            {
              "id": "a",
              "domain": "thermal-liquid",
              "kind": "conserving",
              "label": "Coolant side A",
              "net": null,
              "peers": []
            },
            {
              "id": "b",
              "domain": "thermal-liquid",
              "kind": "conserving",
              "label": "Coolant side B",
              "net": null,
              "peers": []
            }
          ],
          "terms": [
            {
              "type": "liquid-tank",
              "label": "Coolant expansion tank"
            },
            {
              "type": "liquid-pipe",
              "label": "Coolant pipe"
            }
          ],
          "symbol": [
            {
              "tag": "circle",
              "attrs": {
                "cx": 100,
                "cy": 40,
                "r": 32
              }
            },
            {
              "tag": "path",
              "attrs": {
                "d": "M10 40H68M132 40H190M84 13L132 40L84 67"
              }
            }
          ],
          "selection": {},
          "commands": [
            {
              "id": "speed",
              "label": "Relative pump speed",
              "quantity": "fraction",
              "unit": "fraction",
              "active": true,
              "summary": "Relative pump speed is a directed fraction input to this component, expressed in fraction. Its binding supplies information; it is not a conserving connection.",
              "source": null,
              "target": null
            }
          ],
          "outputs": [
            {
              "id": "massFlow",
              "quantity": "mass-rate",
              "declared": true,
              "consumers": [],
              "label": "mass Flow",
              "unit": "kg/s"
            },
            {
              "id": "outletTemperature",
              "quantity": "temperature",
              "declared": true,
              "consumers": [],
              "label": "outlet Temperature",
              "unit": "K"
            },
            {
              "id": "volumeFlow",
              "quantity": "volume-rate",
              "declared": true,
              "consumers": [],
              "label": "volume Flow",
              "unit": "m³/s"
            },
            {
              "id": "pressureRise",
              "quantity": "pressure",
              "declared": true,
              "consumers": [],
              "label": "pressure Rise",
              "unit": "Pa"
            },
            {
              "id": "power",
              "quantity": "power",
              "declared": true,
              "consumers": [],
              "label": "power",
              "unit": "W"
            },
            {
              "id": "fluidPower",
              "quantity": "power",
              "declared": true,
              "consumers": [],
              "label": "fluid Power",
              "unit": "W"
            },
            {
              "id": "loss",
              "quantity": "power",
              "declared": true,
              "consumers": [],
              "label": "loss",
              "unit": "W"
            }
          ],
          "parameters": [
            {
              "id": "shutoffPressurePa",
              "default": 50000,
              "unit": "Pa",
              "min": 0,
              "max": 100000000,
              "value": 50000
            },
            {
              "id": "linearResistance",
              "default": 1000000,
              "unit": "Pa s/m3",
              "min": 1e-06,
              "max": 1000000000000000,
              "value": 1000000
            },
            {
              "id": "quadraticResistance",
              "default": 400000000000,
              "unit": "Pa s2/m6",
              "min": 0,
              "max": 1000000000000000000,
              "value": 400000000000
            },
            {
              "id": "speed",
              "default": 1,
              "unit": "fraction",
              "min": 0,
              "max": 2,
              "value": 1
            },
            {
              "id": "efficiency",
              "default": 0.5,
              "unit": "fraction",
              "min": 0.001,
              "max": 1,
              "value": 0.5
            },
            {
              "id": "volumeM3",
              "default": 0.0001,
              "unit": "m3",
              "min": 1e-07,
              "max": 100,
              "value": 0.0001
            },
            {
              "id": "specificHeatJkgK",
              "default": 4200,
              "unit": "J/(kg K)",
              "min": 1,
              "max": 1000000,
              "value": 4200
            },
            {
              "id": "densityKgM3",
              "default": 1000,
              "unit": "kg/m3",
              "min": 1,
              "max": 100000,
              "value": 1000
            },
            {
              "id": "initialTemperatureK",
              "default": 300,
              "unit": "K",
              "min": 0,
              "max": 5000,
              "value": 300
            }
          ]
        }
      }
    }
  },
  "incoming": [
    {
      "id": "edge:usesBlock/term:heat-transfer-modes/block:liquid-pump",
      "type": "usesBlock",
      "source": "term:heat-transfer-modes",
      "target": "block:liquid-pump",
      "properties": {
        "sourceFile": "studio-help-catalog.json",
        "scope": "Declared interface quantity or semantic operation; not a numerical validation claim"
      }
    },
    {
      "id": "edge:usesBlock/term:operating-temperature/block:liquid-pump",
      "type": "usesBlock",
      "source": "term:operating-temperature",
      "target": "block:liquid-pump",
      "properties": {
        "sourceFile": "studio-help-catalog.json",
        "scope": "Declared interface quantity or semantic operation; not a numerical validation claim"
      }
    },
    {
      "id": "edge:usesBlock/term:power/block:liquid-pump",
      "type": "usesBlock",
      "source": "term:power",
      "target": "block:liquid-pump",
      "properties": {
        "sourceFile": "studio-help-catalog.json",
        "scope": "Declared interface quantity or semantic operation; not a numerical validation claim"
      }
    },
    {
      "id": "edge:usesBlock/term:thermal-model/block:liquid-pump",
      "type": "usesBlock",
      "source": "term:thermal-model",
      "target": "block:liquid-pump",
      "properties": {
        "sourceFile": "studio-help-catalog.json",
        "scope": "Declared interface quantity or semantic operation; not a numerical validation claim"
      }
    }
  ],
  "outgoing": [],
  "neighbors": [
    {
      "id": "term:heat-transfer-modes",
      "type": "Term",
      "label": "Heat transfer modes",
      "properties": {
        "id": "heat-transfer-modes",
        "name": "Heat transfer modes",
        "aka": [
          "conduction",
          "convection",
          "thermal radiation"
        ],
        "section": "topic-thermal",
        "definition": "The three ways heat moves: conduction through solids and still fluids, convection carried by a moving fluid, and radiation emitted as infrared by every warm surface. In a pack, conduction takes heat from the cell into the cooling plate and convection carries it away in the coolant; radiation matters mainly at the high temperatures of thermal runaway.",
        "related": [
          "thermal-conductivity",
          "heat-transfer-coefficient",
          "thermography",
          "cooling-plate",
          "thermal-propagation"
        ],
        "url": "https://lemonergy.com/learn/glossary/heat-transfer-modes/",
        "mentions": [
          "thermal-runaway"
        ]
      }
    },
    {
      "id": "term:operating-temperature",
      "type": "Term",
      "label": "Operating temperature",
      "properties": {
        "id": "operating-temperature",
        "name": "Operating temperature",
        "section": "topic-ratings",
        "definition": "The temperature range a cell may be charged and discharged in, typically 0–45 °C for charging and −20–60 °C for discharging. Charging below 0 °C risks lithium plating; above the range the cell ages fast and may vent.",
        "unit": "°C",
        "related": [
          "lithium-plating",
          "arrhenius",
          "thermal-management",
          "datasheet"
        ],
        "lesson": "fundamentals/battery-aging/#temperature",
        "url": "https://lemonergy.com/learn/glossary/operating-temperature/",
        "mentions": []
      }
    },
    {
      "id": "term:power",
      "type": "Term",
      "label": "Power",
      "properties": {
        "id": "power",
        "name": "Power",
        "section": "topic-units",
        "definition": "The rate at which a cell delivers or absorbs energy: voltage times current, in watts. Power is limited by internal resistance and temperature long before capacity runs out.",
        "formula": "P = V × I",
        "unit": "W",
        "related": [
          "watt",
          "specific-power",
          "state-of-power",
          "internal-resistance"
        ],
        "example": {
          "title": "Separate power from energy",
          "text": "A 100 W load running for 30 min uses 50 Wh. Power tells you how fast energy is transferred; the duration determines how much energy is transferred."
        },
        "url": "https://lemonergy.com/learn/glossary/power/",
        "mentions": []
      }
    },
    {
      "id": "term:thermal-model",
      "type": "Term",
      "label": "Thermal model",
      "properties": {
        "id": "thermal-model",
        "name": "Thermal model",
        "aka": [
          "lumped thermal model"
        ],
        "section": "topic-thermal",
        "definition": "A model of cell temperature: at its simplest one thermal mass with heat generation inside and convection outside, at its most detailed a 3D simulation of the pack. Temperature feeds back into every rate, so electrical and thermal models are usually solved together.",
        "related": [
          "heat-generation",
          "thermal-management",
          "arrhenius",
          "newman-model",
          "thermal-characterisation"
        ],
        "url": "https://lemonergy.com/learn/glossary/thermal-model/",
        "mentions": [
          "thermal-mass",
          "heat-transfer-modes"
        ]
      }
    }
  ]
}