Lemonergy · Studio block

Coolant pipe

Carries coolant between two connections against a linear and a quadratic pressure loss. The loss warms the coolant it carries.

Implementation ID
liquid-pipe
Reviewed
2026-10-30

Behavior

Carries coolant between two connections against a linear and a quadratic pressure loss. The loss warms the coolant it carries.

Interface

Select a terminal or signal to inspect its meaning. This is a conceptual interface, not simulation output.
Ports and observed outputs
NameDirectionUnitMeaning
aconservingthermal-liquidCoolant side A
bconservingthermal-liquidCoolant side B
mass Flowoutputkg/sDirected output available to compatible consumers: mass Flow.
outlet TemperatureoutputKDirected output available to compatible consumers: outlet Temperature.
pressure DropoutputPaDirected output available to compatible consumers: pressure Drop.
hydraulic PoweroutputWDirected output available to compatible consumers: hydraulic Power.

Signal inputs

These directed signals carry information. Conserving terminals exchange the quantities of their physical domain.

Signal outputs

Outputs can supply compatible inputs. Connections and values are inspected in the model that owns them.

Current authoring interface
PinDirectionUnit or domainMeaning
mass Flowoutputkg/sDirected output available to compatible consumers: mass Flow.
outlet TemperatureoutputKDirected output available to compatible consumers: outlet Temperature.
pressure DropoutputPaDirected output available to compatible consumers: pressure Drop.
hydraulic PoweroutputWDirected output available to compatible consumers: hydraulic Power.

Parameters

Defaults are initial model values. Select values for your own model and operating conditions.

Configuration fields
ParameterUnitDefaultMeaning and limits
linearResistance
linearResistance
Pa s/kg10000Declared authoring field: linearResistance.
Minimum 1; Maximum 1000000000000000
quadraticResistance
quadraticResistance
Pa s2/kg20Declared authoring field: quadraticResistance.
Minimum 0; Maximum 1000000000000000000
volumeM3
volumeM3
m30.0001Declared authoring field: volumeM3.
Minimum 1e-07; Maximum 100
specificHeatJkgK
specificHeatJkgK
J/(kg K)4200Declared authoring field: specificHeatJkgK.
Minimum 1; Maximum 1000000
densityKgM3
densityKgM3
kg/m31000Declared authoring field: densityKgM3.
Minimum 1; Maximum 100000
initialTemperatureK
initialTemperatureK
K300Declared authoring field: initialTemperatureK.
Minimum 0; Maximum 5000

Equations and rules

The behavior and configured interface above define this authoring component. This reference does not add numerical equations beyond its source contract.

Use in Studio

Use this authoring component

Choose this component in the Studio library and configure its declared interface. This reference describes the authoring contract; it does not claim a standalone numerical validation or a measured result.

Open Studio →

Use in a workflow

Connected concepts

Limits and interpretation

  • The symbolic diagram describes the component and its declared interface. It is not a solved circuit or simulated output.
  • Configured parameters and model connections determine the result. Check the complete model before interpreting its outputs.

Implementation sources

This reference follows Lemonergy implementation sources. Scientific articles support the linked concepts separately.

Repository: battery-design · Revision: 88d14842e31549cb2004b41abdd64f29ac39ef9c

  • docs/glossary/studio-help-catalog.json

This implementation and its workflow uses (JSON) · Knowledge graph (JSON-LD)

Current authoring interface provenance

The interactive graphic is exported from the same Studio help descriptor. Source base: 88d14842e31549cb2004b41abdd64f29ac39ef9c. File content hashes in the public descriptor catalog identify the exact source snapshot. Existing numerical checks above retain their own verification scope.