Voltage class

The line between circuits that need high-voltage protection and those that do not. UN R100 calls a circuit high voltage above 60 V DC or 30 V AC rms, up to 1500 V DC or 1000 V AC; ISO 6469-3 calls the same band voltage class B and anything lower class A. A 48 V system stays below the line.

Also called
voltage class A, voltage class B, high-voltage threshold, HV, LV

Example

High-voltage and functional safety: an example situation

Normal-operation current limits do not demonstrate correct contactor behavior under a welded-contact or sensor fault.

Read Voltage class alongside 48 V system in this context. A vehicle electrical architecture at 48 V, used for mild hybrids and heavy accessories. It stays below the 60 V threshold at which high-voltage safety rules begin, so it needs no orange cables or interlocks.