Kelvin sensing
Measuring voltage through a separate pair of leads that carry no current, so the drop along current-carrying wires and joints is left out. In a BMS, 100 mA of balancing current through 0.5 Ω of sense wire would add a 50 mV error, so designs either give balancing its own leads or pause balancing while measuring.
- Also called
- four-wire sensing, four-terminal sensing, 4-wire measurement, separate sense and balancing leads
Example
Data, communication and electronics: an example situation
2500 in a log might mean 25.00 °C, 2.5 V or raw counts. Units and scale must accompany the value.
Read Kelvin sensing alongside Cell balancing in this context. Equalising the state of charge of cells in series, since the pack is limited by its emptiest cell on discharge and its fullest on charge. Passive balancing bleeds charge from high cells through resistors; active balancing moves it between cells.
Use in Lemonergy
Separate quantities from encoding and transport.
This is a reference concept. No executable Lemonergy block has been verified for this term.