MathWorks: Heat Conduction Through Iron Rod

The retained campaign contract records the iron-rod inputs and printed answers for Examples 1–3. Campaign source notes record a September 30, 2026 check. The local linear and lumped exponential trajectories are analytical constructions, not downloaded Simscape traces.

Document created Updated
Bibliographic reference · contents not reviewedSource record reviewed

What the rod reference explains

A rod can carry heat along its length, lose heat from its surface, or store heat as its temperature rises. These are different physical questions. Lemonergy uses the retained inputs from this reference in four separate examples: steady conduction, surface convection, insulated heating and a lumped thermal transient.

The attributed source is MathWorks, Heat Conduction Through Iron Rod, specifically Examples 1–3 and the “Lumped Mass Rod Model” equation. The tables below reproduce the retained contract, not a newly inspected version of that webpage. Download the reference contract from the comparison campaign; its thermal.source section records the inputs, equations and printed answers.

Retained geometry, properties and boundaries

In the Basis column, S1 identifies that frozen thermal contract and its source attribution. Property values are held constant in these examples. No material grade, uncertainty or temperature-dependent property curve is established by this record.

QuantitySymbolValueUnitConditions and useBasis
Rod diameterD0.025mUniform cylindrical geometryRetained input · S1
Rod lengthL0.2mAxial lengthRetained input · S1
Densityρ7800kg/m³Thermal storage casesRetained input · S1
Specific heatc447J/(kg·K)Thermal storage casesRetained input · S1
Thermal conductivityk80.2W/(m·K)Axial conduction and lumped modelRetained input · S1
Convection coefficienth32.1W/(m²·K)Surface loss; fixed, not calculated from flowRetained input · S1
Base temperatureTbase100°CConduction and lumped-model boundaryRetained input · S1
Air temperatureTair20°CConvection and lumped-model boundaryRetained input · S1
Initial rod temperatureT020°CTransient initial conditionRetained input · S1
Uniform surface temperatureTsurface55°CConvection-only calculationRetained input · S1
Conducted heat flowQconduction18WImposed steady axial heat flowRetained input · S1
Insulated heat inputQheating18WConstant input with no environmental lossRetained input · S1

Use only the inputs belonging to the selected problem. Density and specific heat do not affect the steady conduction result. The 20 °C air boundary does not apply to its tip: that case prescribes heat flow and base temperature. Likewise, the convection example fixes the rod at 55 °C rather than predicting its cooling.

Equations and printed comparison values

Cross-sectional area is A = πD²/4; lateral surface area is As = πDL. Thermal resistance is L/(kA), and heat capacity is Cth = ρcAL. These quantities are derived from the retained inputs, not independent measurements.

QuantitySymbolValueUnitConditions and equationBasis
Conduction tip temperatureTtip8.5554°CTbase − Qconduction L/(kA); no side lossRounded printed answer · S1
Lateral convection heatQsurface17.6479WhAs(Tsurface − Tair); excludes end facesRounded printed answer · S1
Insulated heating ratedT/dt0.0526K/sQheating/Cth; uniform temperatureRounded printed answer · S1

The contract allows an absolute difference of 0.00005 in each scalar's listed unit, half the last printed decimal. This numerical rounding allowance is not a material tolerance or measurement uncertainty. The solver stores absolute temperatures in kelvin; temperature differences have the same numerical magnitude in kelvin and degrees Celsius.

Lemonergy authors the linear insulated-temperature curve and exponential lumped response from the disclosed balances. They are not exported traces from another application. The 0–1 s steady observation windows and 0–100 s insulated window are authored test choices; the lumped comparison uses 0–2500 s to cover the retained source plot horizon. The single-mass model does not reproduce a spatial fin field or segmented rod.

Publication date and retained provenance

The publication date is unknown. Campaign notes record a source check on 30 September 2026; the frozen thermal contract also records a recheck on 1 October 2026. Those are historical provenance dates, not a claim that the live page was visited when this wiki article was edited.

No complete source-page copy or measured rod trace is retained, and the external application was not executed for this comparison. Documentation URLs can change. Use the frozen contract to reproduce the numerical problem, then follow the individual worked examples for software pictures, block inventories and fresh run instructions.