Arc flash

The burst of heat, light and pressure released by a fault arc. The hazard to a worker is rated as incident energy at working distance; 1.2 cal/cm² is the usual onset of second-degree burns. Large battery systems can feed fault currents of many kiloamperes, so arc flash sets protective clothing and approach limits under NFPA 70E.

Also called
DC arc flash, arc-flash hazard, incident energy
Unit
cal/cm²

Example

High-voltage and functional safety: an example situation

Normal-operation current limits do not demonstrate correct contactor behavior under a welded-contact or sensor fault.

Read Arc flash alongside Arcing in this context. Current continuing through ionised gas across a gap, typically between contacts as they separate. An AC arc goes out by itself at each current zero, a hundred times a second at 50 Hz; a DC arc has no zero and keeps burning until it is stretched and cooled so far that its voltage exceeds the source’s, which makes high-voltage DC far harder to interrupt.

Use in Lemonergy

Relate protection to faults, detection and response.

This is a reference concept. No executable Lemonergy block has been verified for this term.