lemonergy/ wikiSign in

Cost study · Pack Designer cost model

Truck battery module costs

What does Lemonergy’s cost model report for the cells in a truck’s main and reserve modules at market and cell-record prices?

Document created Updated
In progressEvery figure is an output of Lemonergy's cost model

Engineering study

Abstract

At the study’s market cell price, the cells for one swappable main module cost $13,410. Lemonergy’s Pack Designer prices the main and reserve modules at two price bases and reports the energy delivered over cell life. The figures cover cells only and have yet to be checked against a supplier quote or invoice.

The problem it solves

You are a truck maker or fleet asking what the cells of a Lemonergy truck module cost, what they cost per kWh delivered over their life, and how many modules a truck needs over ten years.

What you get

Read the model's figures for each module, the sensitivity to cell price, cycle life and usage, the same model with the cell records' own prices, and a table of what Lemonergy does not compute yet.

What it does not establish

The model prices one module's cells: no busbars, cooling, battery management, housing, assembly, warranty or margin, and no sum for a whole truck. It counts no calendar ageing or discounting, and the market price is for stationary-storage cells.

How this study was done

  1. Question and pass criteriaPartlyThe buyer has yet to set a cost target.
  2. Inputs with sourcesPartlyThe cell price is published. The duty and the module designs are the study's own values, and some cell record fields are estimated.
  3. Lemonergy blocksNot yetThe cost model is the Pack Designer's own code, not library blocks.
  4. RunDone
  5. Result against the criteriaPartlyThe model reports costs without a target.
  6. ValidityPartlyThe model counts cells only, and its figures are not compared with quotes or measured module prices.
  7. ReproduceDone

Reproduce it in Lemonergy Done

Run the module study

  1. Select the swappable main module and the market price.
  2. Read the cell cost and the modules needed at the recorded duty.
  3. Import the matching case file to repeat the run in the Pack Designer.

You should see: The cells of one main module come to $13,410 at the market price, and two modules are needed over ten years.

Lemonergy blocks: noneOutside the library: Cost model: costModel in js/optimizer.js and sensitivityAnalysis in js/sensitivity.js, Module designs in js/dual-battery-truck-feasibility-packs.jsModel: Download a Pack Designer case

Question and pass criteria

Criteria
CriterionLimitSourceResult
Cell budget per moduleUnsetBuyer target pendingReported only

Reported, no limit set

What the cost model gives, at the market cell price
OutputSwappable main moduleFixed reserve moduleUnder-frame reserve string
Cells of one module$13,410$4,634$4,634
Per kWh installed$62.97/kWh$62.97/kWh$62.97/kWh
Energy delivered over the cycle life681,486 kWh235,469 kWh235,469 kWh
Cell cost per kWh delivered$0.020/kWh$0.020/kWh$0.020/kWh
Cell life at the study duty6.7 years6.7 years6.7 years
Modules needed over 10 years222
Cells over 10 years$26,821$9,267$9,267

Not yet. A buyer must set a maximum cell budget per module for a stated price basis and duty.

Run it live

Sensitivity at ±20 %

    Open in the Pack Designer · Recorded workbooks and cases

    The Designer link carries geometry. Enter the cell price and duty and install the private cell if needed. The matching case file includes these inputs.

    Blocks of this study

    Functions used
    FunctionRole
    designFromSpecBuild the recorded module and resolve its inputs.
    costModelCompute module cost, delivered energy and service life.
    sensitivityAnalysisVary each input around the live run.

    Studio blocks: Not yet.

    The trucks in 3D

    Lemonergy Aero tractor

    Results

    At the study’s market cell price, the cells for one swappable main module cost $13,410.

    Swappable main module · market$13,410Swappable main module · record$19,710Fixed reserve module · market$4,634Fixed reserve module · record$6,570Under-frame reserve string · market$4,634Under-frame reserve string · record$6,570
    Cell cost per module at market and record prices

    The main module’s cells cost $0.020/kWh delivered at the market price.

    Swappable main module · market$0.020/kWhSwappable main module · record$0.029/kWhFixed reserve module · market$0.020/kWhFixed reserve module · record$0.028/kWhUnder-frame reserve string · market$0.020/kWhUnder-frame reserve string · record$0.028/kWh
    Cost per kWh delivered over the rated cell life

    One main module lasts 6.7 years at the study duty.

    Swappable main module6.7 yearsFixed reserve module6.7 yearsUnder-frame reserve string6.7 yearsService target10 years
    Service life against the duty, in years

    The model counts 2 modules over the duty, including the first.

    Changing cell price by ±20 % moves lifetime cell cost by $5,364.

    Cell price$5,364Cycle life$0Usage (cycles/year)$0Usable energy (capacity fade)$0
    Largest change in lifetime cell cost from the main-module base of $26,821

    Cycle life and usage leave the module count at 2 at both ends, so the 10-year cell cost does not move.

    Checked against the Pack Designer workbook

    For each of the six runs, a copy of the Pack Designer's exported SpreadsheetML workbook was made and the stored value of every cell that carries a formula (20 per workbook, 7 of them on the Economics sheet) was deleted from the copy, leaving the formulas and the input cells untouched; LibreOffice 24.2.7.2 then loaded each copy headless, calculated the formulas itself and saved the result as .xlsx, from which the seven Economics outputs and the named input cells were read (LibreOffice stores 15 significant digits in .xlsx). Recalculation was shown by checking that no stored value remained in the copy and that every formula cell had a computed number after loading, and by a control copy with the cell price doubled whose upfront cost doubled. Each named input was compared with the matching runnerInputs value (to a relative 1e-12), and each recalculated output with the matching figure in cost.json (modules[id].runs[basis].cost) within the tolerance below; the largest relative difference seen was 7.68e-06, so no error band beyond the six-decimal rounding of cost.json is needed. Note the model field 'replacements' is compared with the sheet's 'Packs needed over target' cell, which is the only integer count on the sheet.

    Checked by Claude Sonnet, an agent that did not write the page, on 2026-11-23, with LibreOffice 24.2.7.2.

    Tolerance: a relative difference up to 2.8e-5. cost.json stores outputs to six decimals, so a stored value can be off by up to 5e-7 in absolute terms, which for the smallest compared output is a relative error of 2.54e-05; the tolerance is set just above that.

    main-market
    OutputcostModel in cost.jsonWorkbook recalculatedRelative differenceAgrees
    upfrontUSD13410.36574913410.36574921.5e-11Yes
    usdPerKWhCap62.9762.970Yes
    throughputKWh681485.952681485.9520Yes
    usdPerKWhDelivered0.0196780.0196781256.4e-6Yes
    serviceYears6.6666676.666666666666675.0e-8Yes
    replacements220Yes
    tcoUSD26820.73149826820.73149841.5e-11Yes
    main-catalog
    OutputcostModel in cost.jsonWorkbook recalculatedRelative differenceAgrees
    upfrontUSD19710197100Yes
    usdPerKWhCap92.55069792.55069721525232.3e-9Yes
    throughputKWh681485.952681485.9520Yes
    usdPerKWhDelivered0.0289220.02892209287976643.2e-6Yes
    serviceYears6.6666676.666666666666675.0e-8Yes
    replacements220Yes
    tcoUSD39420394200Yes
    reserve-market
    OutputcostModel in cost.jsonWorkbook recalculatedRelative differenceAgrees
    upfrontUSD4633.584484633.584480Yes
    usdPerKWhCap62.9762.970Yes
    throughputKWh235468.8235468.80Yes
    usdPerKWhDelivered0.0196780.0196781256.4e-6Yes
    serviceYears6.6666676.666666666666675.0e-8Yes
    replacements220Yes
    tcoUSD9267.168969267.168960Yes
    reserve-catalog
    OutputcostModel in cost.jsonWorkbook recalculatedRelative differenceAgrees
    upfrontUSD657065700Yes
    usdPerKWhCap89.28571489.28571428571433.2e-9Yes
    throughputKWh235468.8235468.80Yes
    usdPerKWhDelivered0.0279020.02790178571428577.7e-6Yes
    serviceYears6.6666676.666666666666675.0e-8Yes
    replacements220Yes
    tcoUSD13140131400Yes
    underFrameReserve-market
    OutputcostModel in cost.jsonWorkbook recalculatedRelative differenceAgrees
    upfrontUSD4633.584484633.584480Yes
    usdPerKWhCap62.9762.970Yes
    throughputKWh235468.8235468.80Yes
    usdPerKWhDelivered0.0196780.0196781256.4e-6Yes
    serviceYears6.6666676.666666666666675.0e-8Yes
    replacements220Yes
    tcoUSD9267.168969267.168960Yes
    underFrameReserve-catalog
    OutputcostModel in cost.jsonWorkbook recalculatedRelative differenceAgrees
    upfrontUSD657065700Yes
    usdPerKWhCap89.28571489.28571428571433.2e-9Yes
    throughputKWh235468.8235468.80Yes
    usdPerKWhDelivered0.0279020.02790178571428577.7e-6Yes
    serviceYears6.6666676.666666666666675.0e-8Yes
    replacements220Yes
    tcoUSD13140131400Yes

    Overall verdict · fit for publication

    The workbook is exported by the same project's Pack Designer from the same inputs, and its formulas were written by the same people as the model's, so this check cannot catch a wrong formula, a wrong input or a shared misconception, only a disagreement between two implementations of the same arithmetic.

    Only a supplier quote or invoice for these cells (the CATL 302Ah and the reserve cell) at truck volumes would settle whether the cell prices, and so the dollar figures, are what a buyer would actually pay.

    All runs

    Inputs
    Module and price basisUSD/cellCellsCycles/yearYearsDoD
    Swappable main module · market61.2345219600100.8
    Swappable main module · catalog90.0000219600100.8
    Fixed reserve module · market21.1579219600100.8
    Fixed reserve module · catalog30.0000219600100.8
    Under-frame reserve string · market21.1579219600100.8
    Under-frame reserve string · catalog30.0000219600100.8
    Outputs
    Module and price basisCells of one moduleCost per installed kWhLifetime throughputCost per delivered kWhService lifeModules neededLifetime cell costVerdictOpen
    Swappable main module · market$13,410$62.97/kWh681,486 kWh$0.020/kWh6.7 years2 modules$26,821Reported, no limit setRun it live · Pack Designer
    Swappable main module · catalog$19,710$92.55/kWh681,486 kWh$0.029/kWh6.7 years2 modules$39,420Reported, no limit setRun it live · Pack Designer
    Fixed reserve module · market$4,634$62.97/kWh235,468.8 kWh$0.020/kWh6.7 years2 modules$9,267Reported, no limit setRun it live · Pack Designer
    Fixed reserve module · catalog$6,570$89.29/kWh235,468.8 kWh$0.028/kWh6.7 years2 modules$13,140Reported, no limit setRun it live · Pack Designer
    Under-frame reserve string · market$4,634$62.97/kWh235,468.8 kWh$0.020/kWh6.7 years2 modules$9,267Reported, no limit setRun it live · Pack Designer
    Under-frame reserve string · catalog$6,570$89.29/kWh235,468.8 kWh$0.028/kWh6.7 years2 modules$13,140Reported, no limit setRun it live · Pack Designer

    Data and files

    The model

    Parameters and assumptions

    The inputs: each module as the Pack Designer designed it
    ModuleCellCellsEnergyCycle life (to 80 %)Cell price, marketCell price in the cell record
    Swappable main moduleCATL 302Ah LiFePO4219s1p, 219 cells213.0 kWh4,000$61.23
    0.972 kWh × $62.97/kWh
    $90.00 estimated
    Fixed reserve moduleEVE LF105219s1p, 219 cells73.6 kWh4,000$21.16
    0.336 kWh × $62.97/kWh
    $30.00 estimated
    Under-frame reserve stringEVE LF105219s1p, 219 cells73.6 kWh4,000$21.16
    0.336 kWh × $62.97/kWh
    $30.00 estimated

    Swappable main module: 2 on every truck. Fixed reserve module: 2 on every truck. Under-frame reserve string: 1 on the Mercedes-Benz eActros 600 only, where it fits under the frame.

    Duty, the same for every module in the study's Pack Designer designs: 600 cycles a year for 10 years, at 0.8 depth of discharge (fraction).

    The market input prices stationary-storage cells. Each reserve uses the main module’s duty. Cell-record prices are estimates.

    Equations

    Pack Designer workbook formulas
    OutputWorkbook formula
    Pack cost (cells)=CellPrice*SCount*PCount
    Cost per kWh capacity=CellPrice*SCount*PCount/(SCount*PCount*VNom*CapAh/1000)
    Lifetime throughput=CycleLife*(SCount*PCount*VNom*CapAh)*DoD/1000
    Cost per kWh DELIVERED=(CellPrice*SCount*PCount)/(CycleLife*(SCount*PCount*VNom*CapAh)*DoD/1000)
    Service life of one pack=CycleLife/CyclesYr
    Packs needed over target=MAX(1,CEILING(CyclesYr*Years/CycleLife,1))
    Lifetime cost (TCO)=CellPrice*SCount*PCount*MAX(1,CEILING(CyclesYr*Years/CycleLife,1))

    CellPrice is USD per cell. SCount and PCount are series and parallel counts. VNom is nominal cell voltage, CapAh is cell capacity in ampere-hours, CycleLife is rated cycles, DoD is usable depth as a fraction, CyclesYr is cycles per year and Years is the service target. CEILING rounds the count up to a whole module. The formulas use Wh per kWh.

    Solver and provenance

    Pack Designer evaluates the module design, then costModel and sensitivityAnalysis run on its resolved inputs. Design commit f29fa42f51544ac7d65d4c39a75d78d793994953. SHA-256 of the exact browser modules:

    • js/sensitivity.js 28e71d42166890b0b4fc9ac6429c1392a14d591eabd05cfb57802e7aaa00e313
    • js/optimizer.js 2048580e2704805112a938a51d78f05f0754683b12b13531107291435aba454e
    • js/pack-engine.js 9ebb9e9883a4436bddfb182358572be2827e299a8fc86faf8c9feb0c6d521c93
    • js/cells.js f193ac5bedb2b6b798aa2aff9b2c9fa04171ba6c3701b5b873a40b38460988cf
    • js/bay.js 2d8b32088e9e758f92bda1582e126d95497a7b5e4c37cdd5cd76a5806a3a07a6
    • js/customer-experience.js 2d58286172916b034d4c71cb102e4c8ca462e0560da9dab0c8f877d6965da8f3
    • js/markets.js 8da8441391992d4677ab5ca89e897c4c9e7901e23d030d5149be1da527f9f798

    Market source and cell record notes · CATL product record · EVE LF105 product record

    Comparison with measurement

    These costs are model outputs. The workbook comparison checks software agreement.

    Not yet. A supplier quote or invoice for these cells at truck volumes, with currency and delivery terms, would settle the price comparison.

    The real hardware

    All five module installations in side elevation
    These side elevations and their labelled figures come from the five-truck price study. They show the fixed reserve ahead of each swappable main module.
    Aero tractor battery integration render
    Battery integration on the Aero. Lemonergy design render, sized on the Volvo FH Electric.

    Not yet. The module has yet to be built.

    Reproduce it step by step

    Quick start

    Open the main market run above. To see the same outputs in the Pack Designer, use its matching case file.

    Annotated Pack Designer cost and lifetime readouts for the main market case
    Main module at the recorded market price. The annotations identify the cell cost and lifetime readouts.
    1. Choose the module and price basis in All runs.
    2. Download its matching case from Data and files.
    3. Open the Pack Designer workspace, use Import case file, and select the JSON.
    4. Open Results, check the price and duty, and compare cell cost, service life and modules needed with the recorded row.
    Prepared model versus a fresh result
    Prepared modelFresh result
    The case holds the private cell, layout and recorded duty.The Pack Designer resolves the case inputs with its current engine.
    The workbook carries recorded values and editable formula inputs.Compare the new outputs with the same module and price basis in All runs.

    Limits and next checks

    What Lemonergy does not compute yet

    What this analysis needs that Lemonergy does not compute yet
    NeededIn Lemonergy todayOn this page
    A cell price per kWhThe Pack Designer takes a price per cell.The published price per kWh is entered as a price per cell: $62.97/kWh times the cell's nominal energy (0.972 kWh for the CATL 302Ah LiFePO4, 0.336 kWh for the EVE LF105). This conversion of the input is the only arithmetic done outside Lemonergy.
    The cost of all the modules on one truckThe cost model prices one module design at a time.Not given. A truck carries two main and two reserve modules; the Mercedes-Benz eActros 600 also has one under-frame reserve string.
    Busbars, cooling plates, battery management, housing, connectors, assembly, warranty and marginNot in the cost model; it prices the cells only.Not given. Every figure here is the cells only.
    A lighter duty for the reserve modulesThe study's designs give every module the same cycles a year.The reserve figures use the main modules' duty. Actual reserve usage has yet to be measured.
    The value left in the last module at the end of serviceThe model counts whole modules over the years of service.Not given. The figures over the years count the last module in full.
    Calendar ageing, discounting and the cost of energyNot in the cost model.Not counted.
    A vehicle-grade cell priceNot in Lemonergy's cell records or sources for these cells.The stationary-storage price is used. A truck-volume quote would establish the vehicle cell price.
    Euro figuresThe cost model works in US dollars.Figures are in US dollars, as the model gives them.

    The study prices cells and models no failure. Factors that can make its figures wrong are listed in What Lemonergy does not compute yet.

    Next checks

    Obtain a truck-volume cell quote and measure the reserve duty.

    Sources

    1. Lithium cost pass-through drives volatile quarter for energy storage cells: Cell Price Review Q3 2026

      Benchmark Mineral Intelligence, 9 October 2026, updated 14 October 2026. Used: LFP prismatic 314 Ah cells, CIF Europe, September 2026, $62.97/kWh.

    2. CATL 302Ah LiFePO4: the Pack Designer's cell record catl-302ah-lfp

      Core electricals from the CATL product spec via contrib/cells/catl/302ah-lifepo4.yaml (302 Ah, 3.22 V, 1C cont charge/discharge, 906 A 30 s pulse at 25 C, 5.51 kg max, >=4000 cycles, 0.18 mOhm 1 kHz AC-IR). Dims are the public LF-type footprint, not from the extracted spec. DCIR ~1.5x AC-IR (estimate); charge temperature window and price estimated.

    3. EVE LF105: the Pack Designer's cell record my-eve-lf105

      Supplied with the dual-battery truck study (js/study-cells.js); not in the shared catalogue, which the Rust migration evidence freezes. Values from EVE product specifications PBRI-LF105-D06-01 rev. D (Nov 2022) and LF105-73103 rev. F (Dec 2019): 105 Ah min at 0.5C, 3.2 V, 2.5-3.65 V, >=336 Wh, 1C continuous charge and discharge, 3C 30 s pulse, 1980 g, 130.3 x 36.7 x 200.5 mm (rev. F thickness; rev. D 36.35), 0.32 mOhm 1 kHz AC-IR (rev. D), DC resistance <=1.8 mOhm (1C, 10 s, 50 % SOC, 25 C; a ceiling, not a typical value). Cycle life >=4000 at 0.5C/0.5C 25 C and >=2000 at 45 C to 80 % (rev. D); >=3500 at 1C/1C 25 C to 80 % (rev. F); end of life below 70 %. Rev. D cites the GB/T traction-battery standards and GB 38031-2020; rev. F names vehicle power and energy storage systems. Temperature windows are the narrower rev. F values (charge 0-55 C, discharge -20-55 C; rev. D states 0-65 C and -35-65 C). DCIR ~1.5x AC-IR (estimate, as for the catalogue's prismatic LFP records); price estimated.

    Cost model and designs: Lemonergy Design commit f29fa42f51544ac7d65d4c39a75d78d793994953.