DC charging at 150 kW and above, up to about 400 kW for cars, usually at 800–1000 V so the current stays within what cable and connector can carry. Liquid-cooled cables make the currents of 500 A and more practical.

Abbreviation
HPC
Also called
ultra-fast charging, ultra-rapid charging

Example

Charging infrastructure: an example situation

A 100 kW model request does not establish real voltage, current, connector or negotiation compatibility.

Read High-power charging alongside Charging curve in this context. The power a vehicle actually accepts against its state of charge during a fast charge: high at low SOC, stepping down as the cells approach voltage and plating limits. The area under it, not the peak kilowatts, decides how long a stop takes.

Use in Lemonergy

Design protocol or analysis tool

Find the charge-time limit

The separate Charge session compares power, current, acceptance and CV limits.

Equation or tool to use

  1. Charge session

    Runs against the selected cell and pack

    Inputs & settings
    • Source power
    • Connector current
    • Start / target SOC
    • End-of-charge C-rate

This overview identifies the components to use. Follow the example in Lemonergy for their connections and settings.

  1. Select a rechargeable cell and pack.
  2. Open Analysis → Charge session; increase power.

Example. A 50 kW source at 400 V cannot deliver 50 kW through a 100 A ceiling; that current limit corresponds to 40 kW.

Observe. Read the named limiting reason.

This differs from the Studio network and requires cell resistance data and product access.

Open Design → Charge session →

References & further reading

Further reading on this topic

These sources provide broader context; they are not presented as citations for every statement in this entry.

  1. Electric Vehicle Charging Stations

    U.S. Department of Energy, Alternative Fuels Data Center

    Topic background · U.S. charging equipment levels, charging infrastructure and connector context. Regional terminology varies.