Contactor arc suppression

The means by which a high-voltage DC contactor breaks current under load. Permanent magnets push the arc sideways to stretch and cool it — so many contactors are polarised and break less current in reverse — and hermetically sealed chambers filled with hydrogen or hydrogen–nitrogen gas cool the arc and keep the contacts clean.

Also called
magnetic blow-out, arc quenching, arc chute, gas-filled contactor

Example

High-voltage and functional safety: an example situation

Normal-operation current limits do not demonstrate correct contactor behavior under a welded-contact or sensor fault.

Read Contactor arc suppression alongside Arcing in this context. Current continuing through ionised gas across a gap, typically between contacts as they separate. An AC arc goes out by itself at each current zero, a hundred times a second at 50 Hz; a DC arc has no zero and keeps burning until it is stretched and cooled so far that its voltage exceeds the source’s, which makes high-voltage DC far harder to interrupt.

Use in Lemonergy

Relate protection to faults, detection and response.

This is a reference concept. No executable Lemonergy block has been verified for this term.