Lemonergy · Studio block
Physical signal integrator
Accumulates a typed rate over native simulation time, starting from its configured initial value.
- Implementation ID
signal-integrator- Reviewed
- 2026-10-30
Behavior
Accumulates a typed rate over native simulation time, starting from its configured initial value.
Interface
| Name | Direction | Unit | Meaning |
|---|---|---|---|
Input signal | input | W | Input signal is a directed power input to this component, expressed in W. Its binding supplies information; it is not a conserving connection. |
Typed signal output | output | J | Directed output available to compatible consumers: Typed signal output. |
Signal inputs
These directed signals carry information. Conserving terminals exchange the quantities of their physical domain.
Signal outputs
Outputs can supply compatible inputs. Connections and values are inspected in the model that owns them.
| Pin | Direction | Unit or domain | Meaning |
|---|---|---|---|
| Input signal | input | W | Input signal is a directed power input to this component, expressed in W. Its binding supplies information; it is not a conserving connection. |
| Typed signal output | output | J | Directed output available to compatible consumers: Typed signal output. |
Parameters
Defaults are initial model values. Select values for your own model and operating conditions.
| Parameter | Unit | Default | Meaning and limits |
|---|---|---|---|
initialinitial | declared output quantity | 0 | Declared authoring field: initial. Minimum -1000000000000000; Maximum 1000000000000000 |
stateScalestateScale | characteristic output magnitude | 1000000 | Declared authoring field: stateScale. Minimum 1e-09; Maximum 1000000000000000 |
rateScalerateScale | characteristic rate magnitude | 1000 | Declared authoring field: rateScale. Minimum 1e-09; Maximum 1000000000000 |
Equations and rules
The behavior and configured interface above define this authoring component. This reference does not add numerical equations beyond its source contract.
Use in Studio
Use this authoring component
Choose this component in the Studio library and configure its declared interface. This reference describes the authoring contract; it does not claim a standalone numerical validation or a measured result.
Open Studio →Use in a workflow
Connected concepts
Limits and interpretation
- The symbolic diagram describes the component and its declared interface. It is not a solved circuit or simulated output.
- Configured parameters and model connections determine the result. Check the complete model before interpreting its outputs.
Implementation sources
This reference follows Lemonergy implementation sources. Scientific articles support the linked concepts separately.
Repository: battery-design · Revision: 0a28f1a0a75a0447903b868cbcc734133a77a847
docs/glossary/studio-help-catalog.json
This implementation and its workflow uses (JSON) · Knowledge graph (JSON-LD)
Current authoring interface provenance
The interactive graphic is exported from the same Studio help descriptor. Source base: 0a28f1a0a75a0447903b868cbcc734133a77a847. File content hashes in the public descriptor catalog identify the exact source snapshot. Existing numerical checks above retain their own verification scope.