Lemonergy · Studio block

Sensor

A sampled reading: seeded Gaussian noise, a quantisation step and a latency in samples — reproducible, not a characterised sensor.

Implementation ID
sensor
Reviewed
2026-10-30

Behavior

A sampled reading: seeded Gaussian noise, a quantisation step and a latency in samples — reproducible, not a characterised sensor.

Interface

input → operation → resultSensorMeasured signalinput · —Outputoutput · —
Select a terminal or signal to inspect its meaning. This is a conceptual interface, not simulation output.
Ports and observed outputs
NameDirectionUnitMeaning
Measured signalinput—Number; Scalar; real. Received from a connected producer.
Outputoutput—Number; Scalar; real. Produced for connected consumers.

Signal inputs

These directed signals carry information. Conserving terminals exchange the quantities of their physical domain.

Signal outputs

Outputs can supply compatible inputs. Connections and values are inspected in the model that owns them.

Current authoring interface
PinDirectionUnit or domainMeaning
Measured signalinput—Number; Scalar; real. Received from a connected producer.
Outputoutput—Number; Scalar; real. Produced for connected consumers.

Parameters

Defaults are initial model values. Select values for your own model and operating conditions.

Configuration fields
ParameterUnitDefaultMeaning and limits
Sample time
sampleTimeS
s0.01Declared authoring field: Sample time.
Noise standard deviation
noiseStd
0Declared authoring field: Noise standard deviation.
Quantisation step
quantizationStep
0Declared authoring field: Quantisation step.
Latency
latencySamples
samples0Declared authoring field: Latency.
Noise seed
seed
1518465946Declared authoring field: Noise seed.

Equations and rules

The behavior and configured interface above define this authoring component. This reference does not add numerical equations beyond its source contract.

Use in Studio

Use this authoring component

Choose this component in the Studio library and configure its declared interface. This reference describes the authoring contract; it does not claim a standalone numerical validation or a measured result.

Open Studio →

Use in a workflow

Limits and interpretation

  • The symbolic diagram describes the component and its declared interface. It is not a solved circuit or simulated output.
  • Configured parameters and model connections determine the result. Check the complete model before interpreting its outputs.

Implementation sources

This reference follows Lemonergy implementation sources. Scientific articles support the linked concepts separately.

Repository: battery-design · Revision: e248d21a9902225f1075624f23e7628b54cdb7cc

  • docs/glossary/studio-help-catalog.json

This implementation and its workflow uses (JSON) · Knowledge graph (JSON-LD)

Current authoring interface provenance

The interactive graphic is exported from the same Studio help descriptor. Source base: e248d21a9902225f1075624f23e7628b54cdb7cc. File content hashes in the public descriptor catalog identify the exact source snapshot. Existing numerical checks above retain their own verification scope.