Lemonergy · Studio block
Resettable running minimum and maximum
Tracks running extrema and resets both to the current value on command.
- Implementation ID
native-resettable-minmax- Reviewed
- 2026-10-27
Behavior
On reset, minimum = maximum = u; otherwise update the running extrema. The worked example connects this operation to signals in Lemonergy Studio.
Interface
| Name | Direction | Unit | Meaning |
|---|---|---|---|
in0 | input | 1 | Value; real scalar. |
in1 | input | 1 | Reset; bool scalar. |
out0 | output | 1 | Minimum; real scalar. |
out1 | output | 1 | Maximum; real scalar. |
Parameters
Defaults are initial model values. Select values for your own model and operating conditions.
| Parameter | Unit | Default | Meaning and limits |
|---|---|---|---|
Sample periodsampleTimeS | s | 0.1 | Exact sample grid period. Elapsed-time integration begins after initialization. Minimum 1e-06 |
Equations and rules
On reset, minimum = maximum = u; otherwise update the running extrema
Worked example
Resettable running minimum and maximum — worked example
Value = 3; Reset = 0. Minimum at 0 s = 3; Maximum at 0 s = 3.
Open Studio example after release →| Output | Time (s) | Expected value | Unit | Absolute tolerance |
|---|---|---|---|---|
Minimumout0 | 0 | 3 | 1 | 1e-08 |
Maximumout1 | 0 | 3 | 1 | 1e-08 |
Explore the recorded outputs
Resettable running minimum and maximum recorded example
Resettable running minimum and maximum / Minimum11 actual recorded samples. Lines are visual guides between samples. Synthetic example, not measured cell data.
Read the selected signal as a table
| Time (s) | Value |
|---|
Download the recorded samples (JSON) · Open this Studio example after release
Use in a workflow
Resettable running minimum and maximum — worked example
Tracks running extrema and resets both to the current value on command.
- Resettable running minimum and maximum: On reset, minimum = maximum = u; otherwise update the running extrema. The worked example connects this operation to signals in Lemonergy Studio.
- Use the block reference for settings and connections.
- Implementation tested locally; public release pending.
Connected concepts
Limits and interpretation
- Per-element running extrema with Boolean reset, evaluated at configured sample instants.
- Shapes and element types are explicit. Values must be finite; automatic reshaping and unit conversion are not performed.
Reference basis
This software operation and its numerical conventions are defined by the public contract and worked example; no external research result is claimed.
Implementation sources
This reference follows the public interface and locally verified numerical checks for an upcoming release.
Contract: Lemonergy Studio public contract · Verification record: verification-2026-10-27
docs/glossary/native-block-verification.json
This implementation and its workflow uses (JSON) · Knowledge graph (JSON-LD)