Lemonergy · Studio block
Pulse generator
Generates a periodic rectangular signal with explicit amplitude, duty fraction, phase delay and bias.
- Implementation ID
native-pulse- Reviewed
- 2026-10-27
Behavior
y = bias + amplitude while phase is inside the duty fraction; otherwise bias. phase = (t − delay) modulo period.
Interface
| Name | Direction | Unit | Meaning |
|---|---|---|---|
out0 | output | 1 | Signal; real scalar. |
Parameters
Defaults are initial model values. Select values for your own model and operating conditions.
| Parameter | Unit | Default | Meaning and limits |
|---|---|---|---|
Amplitudeparams[0] | 1 | 2 | Configured value for Amplitude. |
Periodparams[1] | s | 1 | Configured value for Period. |
Duty fraction (0–1)params[2] | 1 | 0.5 | Configured value for Duty fraction (0–1). |
Phase delayparams[3] | s | 0 | Configured value for Phase delay. |
Biasparams[4] | 1 | 0 | Configured value for Bias. |
Equations and rules
y = bias + amplitude while phase is inside the duty fraction; otherwise biasphase = (t − delay) modulo period
Worked example
Pulse generator — worked example
Use the configured source parameters. Signal at 0 s = 2; Signal at 0.5 s = 0; Signal at 1 s = 2.
Open Studio example after release →| Output | Time (s) | Expected value | Unit | Absolute tolerance |
|---|---|---|---|---|
Signalout0 | 0 | 2 | 1 | 1e-09 |
Signalout0 | 0.5 | 0 | 1 | 1e-09 |
Signalout0 | 1 | 2 | 1 | 1e-09 |
Explore the recorded outputs
Pulse generator recorded example
Pulse generator3 actual recorded samples. Lines are visual guides between samples. Synthetic example, not measured cell data.
Read the selected signal as a table
| Time (s) | Value |
|---|
Download the recorded samples (JSON) · Open this Studio example after release
Use in a workflow
Pulse generator — worked example
Generates a periodic rectangular signal with explicit amplitude, duty fraction, phase delay and bias.
- Pulse generator: y = bias + amplitude while phase is inside the duty fraction; otherwise bias. phase = (t − delay) modulo period.
- Use the block reference for settings and connections.
- Implementation tested locally; public release pending.
Connected concepts
Limits and interpretation
- Scalar real output; duty must be between zero and one. Exact edges are bounded to 100000 per source per run.
Reference basis
This software operation is defined by its public contract and worked example; no external research result is claimed.
Implementation sources
This reference follows the public interface and locally verified numerical checks for an upcoming release.
Contract: Lemonergy Studio public contract · Verification record: verification-2026-10-27