Lemonergy · Studio block

Sampled dynamic rate limiter

Limits sampled output changes using connected rising and falling rate bounds.

Implementation ID
native-dynamic-rate-limiter
Reviewed
2026-10-27

Behavior

y[k] = y[k−1] + clamp(u[k]−y[k−1], −connected_fall Δt, connected_rise Δt). The worked example connects this operation to signals in Lemonergy Studio.

Interface

Sampled dynamic rate limiter interfaceInputs or arguments on the left, observed outputs on the right. Conserving terminals appear below the component. The tables give units and behavior.Sampled dynamic rate limiterStudio blockin0in1in2out0
Original Lemonergy interface view. Lines identify ports; they are not a completed simulation circuit.
Ports and observed outputs
NameDirectionUnitMeaning
in0input1Value; real scalar.
in1input1Rising rate; real scalar.
in2input1Falling rate magnitude; real scalar.
out0output1Limited; real scalar.

Parameters

Defaults are initial model values. Select values for your own model and operating conditions.

Configuration fields
ParameterUnitDefaultMeaning and limits
Sample period
sampleTimeS
s0.1Exact sample grid period. Elapsed-time integration begins after initialization.
Minimum 1e-06
Initial output
tables[0]
1[0]Configured coefficients or initial values in column-major order.

Equations and rules

  • y[k] = y[k−1] + clamp(u[k]−y[k−1], −connected_fall Δt, connected_rise Δt)

Worked example

Sampled dynamic rate limiter — worked example

Value = 10; Rising rate = 2; Falling rate magnitude = 3. Limited at 1 s = 2.

Open Studio example after release →
Numerical checks for the bundled synthetic example
OutputTime (s)Expected valueUnitAbsolute tolerance
Limited
out0
1211e-08

Explore the recorded outputs

Sampled dynamic rate limiter recorded example

Sampled dynamic rate limiter
Sampled dynamic rate limiter against timeRecorded synthetic simulation values. Time in seconds; output in —.-0.1600.420.2510.51.580.752.161—Time (s)
Sampled dynamic rate limiter: 0 — at 0 s

11 actual recorded samples. Lines are visual guides between samples. Synthetic example, not measured cell data.

Download the recorded samples (JSON) · Open this Studio example after release

Use in a workflow

Sampled dynamic rate limiter — worked example

Limits sampled output changes using connected rising and falling rate bounds.

  1. Sampled dynamic rate limiter: y[k] = y[k−1] + clamp(u[k]−y[k−1], −connected_fall Δt, connected_rise Δt). The worked example connects this operation to signals in Lemonergy Studio.
    • Use the block reference for settings and connections.
    • Implementation tested locally; public release pending.
Open Studio example after release

Connected concepts

Limits and interpretation

  • Connected rising/falling rates limit elapsed sample changes. Ideal continuous-rate dynamics are not implemented.
  • Shapes and element types are explicit. Values must be finite; automatic reshaping and unit conversion are not performed.

Reference basis

This software operation and its numerical conventions are defined by the public contract and worked example; no external research result is claimed.

Implementation sources

This reference follows the public interface and locally verified numerical checks for an upcoming release.

Contract: Lemonergy Studio public contract · Verification record: verification-2026-10-27

  • docs/glossary/native-block-verification.json

This implementation and its workflow uses (JSON) · Knowledge graph (JSON-LD)