Lemonergy · Studio block

Conditional hold

Updates a held value only while a Boolean enable input is true.

Implementation ID
native-conditional-hold
Reviewed
2026-10-27

Behavior

held[k] = u[k] when enabled; otherwise held[k−1]. The worked example connects this operation to signals in Lemonergy Studio.

Interface

Conditional hold interfaceInputs or arguments on the left, observed outputs on the right. Conserving terminals appear below the component. The tables give units and behavior.Conditional holdStudio blockin0in1out0
Original Lemonergy interface view. Lines identify ports; they are not a completed simulation circuit.
Ports and observed outputs
NameDirectionUnitMeaning
in0input1Value; real scalar.
in1input1Enable; bool scalar.
out0output1Held; real scalar.

Parameters

Defaults are initial model values. Select values for your own model and operating conditions.

Configuration fields
ParameterUnitDefaultMeaning and limits
Sample period
sampleTimeS
s0.1Exact sample grid period. Elapsed-time integration begins after initialization.
Minimum 1e-06
Initial held value
tables[0]
1[2]Configured coefficients or initial values in column-major order.

Equations and rules

  • held[k] = u[k] when enabled; otherwise held[k−1]

Worked example

Conditional hold — worked example

Value = 5; Enable = 0. Held at 0 s = 2.

Open Studio example after release →
Numerical checks for the bundled synthetic example
OutputTime (s)Expected valueUnitAbsolute tolerance
Held
out0
0211e-08

Explore the recorded outputs

Conditional hold recorded example

Conditional hold
Conditional hold against timeRecorded synthetic simulation values. Time in seconds; output in —.1.501.750.2520.52.250.752.51—Time (s)
Conditional hold: 2 — at 0 s

11 actual recorded samples. Lines are visual guides between samples. Synthetic example, not measured cell data.

Download the recorded samples (JSON) · Open this Studio example after release

Use in a workflow

Conditional hold — worked example

Updates a held value only while a Boolean enable input is true.

  1. Conditional hold: held[k] = u[k] when enabled; otherwise held[k−1]. The worked example connects this operation to signals in Lemonergy Studio.
    • Use the block reference for settings and connections.
    • Implementation tested locally; public release pending.
Open Studio example after release

Connected concepts

Limits and interpretation

  • Shapes and element types are explicit. Values must be finite; automatic reshaping and unit conversion are not performed.

Reference basis

This software operation and its numerical conventions are defined by the public contract and worked example; no external research result is claimed.

Implementation sources

This reference follows the public interface and locally verified numerical checks for an upcoming release.

Contract: Lemonergy Studio public contract · Verification record: verification-2026-10-27

  • docs/glossary/native-block-verification.json

This implementation and its workflow uses (JSON) · Knowledge graph (JSON-LD)