Passive cell balancer
Hysteresis selects high cells and reports bleed current and resistor heat.
- Implementation ID
battery-passive-balancer- Reviewed
- 2026-10-27
Behavior
Selects cells above the lowest cell voltage using separate turn-on and turn-off differences. Enabled channels report bleed current and resistor heat; the signal block itself does not impose the electrical current.
Interface
| Name | Direction | Unit | Meaning |
|---|---|---|---|
voltage | input | V | Cell voltages; 3 channels at the default configuration. |
enable | input | true / false | Enable; scalar. |
active | output | true / false | Bleed switches; 3 channels at the default configuration. |
current | output | A | Bleed currents; 3 channels at the default configuration. |
heat | output | W | Bleed power; 3 channels at the default configuration. |
Parameters
Defaults are initial model values. Select values for your own model and operating conditions.
| Parameter | Unit | Default | Meaning and limits |
|---|---|---|---|
Sample interval (s)sampleTimeS | s | 1 | Positive sample interval. Initialization has zero elapsed time; subsequent accepted samples update memory. |
Number of measurement channelscells | 1 | 3 | Number of measurement channels. This is an editable model input; the default belongs to the synthetic worked example. |
Turn-on voltage difference (V)onDeltaV | V | 0.02 | Turn-on voltage difference (V). This is an editable model input; the default belongs to the synthetic worked example. |
Turn-off voltage difference (V)offDeltaV | V | 0.01 | Turn-off voltage difference (V). This is an editable model input; the default belongs to the synthetic worked example. |
Bleed resistor (Ω)resistanceOhm | Ω | 40 | Bleed resistor (Ω). This is an editable model input; the default belongs to the synthetic worked example. |
Minimum voltage (V)minVoltageV | V | 3 | Minimum voltage (V). This is an editable model input; the default belongs to the synthetic worked example. |
Equations and rules
Ibleed[j] = selected[j] * voltage[j] / resistancePbleed[j] = voltage[j] * Ibleed[j]
Worked example
Passive cell balancer worked example
Use the defaults below with Cell voltages = [3.95, 4, 3.96] V, Enable = 1 true / false. At 0 s, Bleed switches is [0, 1, 0] true / false. Additional checks are listed below.
Open Studio example after release →| Output | Time (s) | Expected value | Unit | Absolute tolerance |
|---|---|---|---|---|
Bleed switchesactive | 0 | [false, true, false] | true / false | 1e-08 |
Bleed currentscurrent | 0 | [0, 0.1, 0] | A | 1e-08 |
Bleed powerheat | 0 | [0, 0.4, 0] | W | 1e-08 |
Explore the recorded outputs
Passive cell balancer recorded example
Passive cell balancer / Bleed currents [1]2 actual recorded samples. Lines are visual guides between samples. Synthetic example, not measured cell data.
Read the selected signal as a table
| Time (s) | Value |
|---|
Download the recorded samples (JSON) · Open this Studio example after release
Use in a workflow
Passive cell balancer worked example
Hysteresis selects high cells and reports bleed current and resistor heat.
- Passive cell balancer: Selects cells above the lowest cell voltage using separate turn-on and turn-off differences. Enabled channels report bleed current and resistor heat; the signal block itself does not impose the electrical current.
- Use the parameter values in the block reference.
- Implementation tested locally; public release pending.
Connected concepts
Limits and interpretation
- Connect the request to a physical balancing interface to load a conserving network. The synthetic resistor is not a hardware rating.
- The example verifies numerical behavior for synthetic parameters. Cell characterization and validation for an intended use are separate tasks.
Scientific and mathematical references
These sources explain the scientific and mathematical background. The behavior, interface and limits above define the Lemonergy implementation; a citation does not imply every model option in the source is implemented.
- Getting Started with the BQ76925
Texas Instruments · 2019
Technical reference · A concrete BMS analog front-end example: cell voltage, current, temperature measurement and MCU integration.
Implementation sources
This reference follows the public interface and locally verified numerical checks for an upcoming release.
Contract: Lemonergy Studio public contract · Verification record: verification-2026-10-27
docs/glossary/native-block-verification.json
This implementation and its workflow uses (JSON) · Knowledge graph (JSON-LD)