lemonergy/ data

GS Yuasa Lithium Power LSE110

110 Ah LCO prismatic cell.

Every value read from the datasheet, with the conditions it was stated at.

Compare in the finderSource documentRecord as JSON (API)Report a correction

Capacity
110Ah
Nominal voltage
3.7V
Energy
407Wh
Mass
2.77kg
Specific energy
163Wh/kg
Energy density
334Wh/L
Dimensions
208 × 130 × 50mm
Continuous discharge
110 A · 1C
Operating temperature1
−10 to 35°C
  1. 1Operating temperature: discharge; charge 10 to 35 °C.
  2. Not stated by the source: cycle life, internal resistance.

Curves

1 curve from the datasheet. A further source for this battery, the maker's datasheet: GS Yuasa Lithium Power, Lithium Ion Cells For Satellites - Energy Optimized (LSE Gen III): the LSE110 cycle-test capacity points, plots 1 curve; they are drawn below with its name on each figure.

LSE110 C/2 Capacity
digitised from the datasheet
Lemonergy Data, https://lemonergy.com/data/, CC BY 4.0: credit Lemonergy when you reuse this figure0200400600800100012001400110112114116118120Cycle number, cyclesCapacity, AhCycle number 14 LSE110 C/2 Capacity: 119.40 AhCycle number 42 LSE110 C/2 Capacity: 119.40 AhCycle number 70 LSE110 C/2 Capacity: 119.06 AhCycle number 98 LSE110 C/2 Capacity: 118.27 AhCycle number 126 LSE110 C/2 Capacity: 118.10 AhCycle number 154 LSE110 C/2 Capacity: 117.70 AhCycle number 182 LSE110 C/2 Capacity: 116.57 AhCycle number 210 LSE110 C/2 Capacity: 116.27 AhCycle number 238 LSE110 C/2 Capacity: 115.96 AhCycle number 266 LSE110 C/2 Capacity: 115.90 AhCycle number 294 LSE110 C/2 Capacity: 115.50 AhCycle number 322 LSE110 C/2 Capacity: 115.50 AhCycle number 350 LSE110 C/2 Capacity: 115.47 AhCycle number 378 LSE110 C/2 Capacity: 115.20 AhCycle number 406 LSE110 C/2 Capacity: 114.93 AhCycle number 434 LSE110 C/2 Capacity: 114.66 AhCycle number 462 LSE110 C/2 Capacity: 114.20 AhCycle number 490 LSE110 C/2 Capacity: 114.60 AhCycle number 518 LSE110 C/2 Capacity: 114.60 AhCycle number 546 LSE110 C/2 Capacity: 114.60 AhCycle number 574 LSE110 C/2 Capacity: 114.60 AhCycle number 602 LSE110 C/2 Capacity: 114.36 AhCycle number 630 LSE110 C/2 Capacity: 114.06 AhCycle number 658 LSE110 C/2 Capacity: 113.76 AhCycle number 686 LSE110 C/2 Capacity: 113.48 AhCycle number 714 LSE110 C/2 Capacity: 113.32 AhCycle number 742 LSE110 C/2 Capacity: 113.16 AhCycle number 770 LSE110 C/2 Capacity: 113.00 AhCycle number 798 LSE110 C/2 Capacity: 112.83 AhCycle number 826 LSE110 C/2 Capacity: 112.87 AhCycle number 854 LSE110 C/2 Capacity: 112.96 AhCycle number 882 LSE110 C/2 Capacity: 113.05 AhCycle number 910 LSE110 C/2 Capacity: 112.87 AhCycle number 938 LSE110 C/2 Capacity: 112.56 AhCycle number 966 LSE110 C/2 Capacity: 112.49 AhCycle number 994 LSE110 C/2 Capacity: 112.41 AhCycle number 1022 LSE110 C/2 Capacity: 111.91 AhCycle number 1050 LSE110 C/2 Capacity: 111.80 AhCycle number 1078 LSE110 C/2 Capacity: 111.80 AhCycle number 1106 LSE110 C/2 Capacity: 111.80 AhCycle number 1134 LSE110 C/2 Capacity: 111.69 AhCycle number 1162 LSE110 C/2 Capacity: 111.27 AhCycle number 1190 LSE110 C/2 Capacity: 111.22 AhCycle number 1218 LSE110 C/2 Capacity: 111.16 AhCycle number 1246 LSE110 C/2 Capacity: 111.11 Ah
LSE110 80% DoD Life Cycle Testing with Capacity Retention Model: discharge, 55 A, at 15 °C. From a further source for this battery, the maker's datasheet: GS Yuasa Lithium Power, Lithium Ion Cells For Satellites - Energy Optimized (LSE Gen III): the LSE110 cycle-test capacity points. Not stated: capacity the rate refers to, lower voltage. Points were digitised from the figure image (recipe: review/digitisation/gs-yuasa-lse-gen3-energy-lse110-life-cycle-capacity.json). Curves from this document are in review/revisions/gs-yuasa-lithium-power/lse110-gen-iii-energy-data-sheet-figures.yaml.
Table: 1 line
LinePointsNotes
LSE110 C/2 Capacity28hidden 67–104 cycles, 179–216 cycles, 244–272 cycles, 347–440 cycles, 477–552 cycles, 580–673 cycles, 692–785 cycles, 804–897 cycles, 925–999 cycles, 1037–1130 cycles, 1148–1251 cycles, spanned
Free, sent to your email

Specifications

Every value, with its conditions. 19 quantities stated by the datasheet, grouped as in the finder. Conditions are the rate, temperature and limits each value was stated at.

Current and power

Continuous discharge current
110 A
maximum value. Not stated: temperature
Max. Continuous Discharge Current (A) | 110 | 145 | 190 · page 1, Cell Specifications table, column LSE110 (first of LSE110, LSE145, LSE190)
Continuous charge current
55 A
maximum value. Not stated: temperature
Max. Continuous Charge Current (A) | 55 | 72.5 | 95 · page 1, Cell Specifications table, column LSE110 (first of LSE110, LSE145, LSE190)
Pulse discharge current
330 A
5 s pulse · maximum value. Not stated: temperature
Max. Pulse Discharge Current (A) (5 seconds) | 330 | 435 | 570 · page 1, Cell Specifications table, column LSE110 (first of LSE110, LSE145, LSE190)

Density

Specific energy
163 Wh/kg
Not stated: rate, temperature
Specific Energy at BOL (Wh/kg) | 163 | 168 | 165 · page 1, Cell Specifications table, column LSE110 (first of LSE110, LSE145, LSE190)
Energy density
334 Wh/L
Not stated: rate, temperature
Energy Density at BOL (Wh/L) | 334 | 348 | 373 · page 1, Cell Specifications table, column LSE110 (first of LSE110, LSE145, LSE190)

Electrical

Nominal voltage
3.7 V
nominal value
Nominal Voltage (V) | 3.7 | 3.7 | 3.7 · page 1, Cell Specifications table, column LSE110 (first of LSE110, LSE145, LSE190)
Capacity
110 Ah
rated value. Not stated: rate, temperature, discharge cut-off voltage
Capacity (Ah) | Nameplate | 110 | 145 | 190 · page 1, Cell Specifications table, column LSE110 (first of LSE110, LSE145, LSE190)
Capacity
122 Ah
initial value. Not stated: rate, temperature, discharge cut-off voltage
BOL | 122 | 161 | 205 · page 1, Cell Specifications table, column LSE110 (first of LSE110, LSE145, LSE190)
Charge cutoff voltage
4.1 V
standard value
End of Charge (V) | 4.1 | 4.1 | 4.1 · page 1, Cell Specifications table, column LSE110 (first of LSE110, LSE145, LSE190)
Discharge cutoff voltage
2.75 V
standard value
End of Discharge (V) | 2.75 | 2.75 | 2.75 · page 1, Cell Specifications table, column LSE110 (first of LSE110, LSE145, LSE190)
Energy
407 Wh
rated value. Not stated: rate, temperature
Energy (Wh) | Nameplate | 407 | 536 | 703 · page 1, Cell Specifications table, column LSE110 (first of LSE110, LSE145, LSE190)
Energy
451 Wh
initial value. Not stated: rate, temperature
BOL | 451 | 595 | 758 · page 1, Cell Specifications table, column LSE110 (first of LSE110, LSE145, LSE190)

Physical

Mass
2.77 kg
nominal value
Weight (kg) | 2.77 | 3.55 | 4.59 · page 1, Cell Specifications table, column LSE110 (first of LSE110, LSE145, LSE190)
Height
208 mm
nominal value
Height * | 208 | 263 | 263 · page 1, Cell Specifications table, column LSE110 (first of LSE110, LSE145, LSE190)
Width
130 mm
nominal value
Dimensions (mm) | Width | 130 | 130 | 165 · page 1, Cell Specifications table, column LSE110 (first of LSE110, LSE145, LSE190)
Thickness
50 mm
nominal value
Thickness | 50 | 50 | 50 · page 1, Cell Specifications table, column LSE110 (first of LSE110, LSE145, LSE190)
Volume
1.35 L
nominal value
Volume (L) | 1.35 | 1.71 | 2.03 · page 1, Cell Specifications table, column LSE110 (first of LSE110, LSE145, LSE190)

Thermal and safety

Operating temperature, min
10 °C
charge · minimum value. Not stated: temperature reference
Charge | 10 ~ 35 | 10 ~ 35 | 10 ~ 35 · page 1, Cell Specifications table, column LSE110 (first of LSE110, LSE145, LSE190)
Operating temperature, min
−10 °C
discharge · minimum value. Not stated: temperature reference
Discharge | -10 ~ 35 | -10 ~ 35 | -10 ~ 35 · page 1, Cell Specifications table, column LSE110 (first of LSE110, LSE145, LSE190)
Operating temperature, max
35 °C
charge · maximum value. Not stated: temperature reference
Same passage as operating temperature, min · page 1, Cell Specifications table, column LSE110 (first of LSE110, LSE145, LSE190)
Operating temperature, max
35 °C
discharge · maximum value. Not stated: temperature reference
Same passage as operating temperature, min · page 1, Cell Specifications table, column LSE110 (first of LSE110, LSE145, LSE190)
Storage temperature min
−10 °C
minimum value. Not stated: duration
Storage | -10 ~ 10 | -10 ~ 10 | -10 ~ 10 · page 1, Cell Specifications table, column LSE110 (first of LSE110, LSE145, LSE190)
Storage temperature max
10 °C
maximum value. Not stated: duration
Same passage as storage temperature min · page 1, Cell Specifications table, column LSE110 (first of LSE110, LSE145, LSE190)

Chemistry

What it is made of. Classified as Lithium-ion · LCO.

Classified as
Lithium-ion · LCO
Designation
LCO
Cathode
Lithium Cobalt Oxide

Chemistry | Lithium Cobalt Oxide

Source and dates

One document behind every value. Each value above is read from it, and quoted where the record holds the passage.

Document
GS Yuasa Lithium Power, Lithium Ion Cells For Satellites - Energy Optimized (LSE Gen III: LSE110, LSE145, LSE190)
Kind
datasheet
SHA-256
af43159c81609d2940b2fb4ca9ca2fcf662d026aa0e35794f516e2737193e24e
Note
Two-page GS Yuasa Lithium Power data sheet, served by the maker's own website (gsyuasa-lp.com, Spec Sheets & SDS page, file GS_Yuasa_LSE_GEN_III_Energy.pdf). It prints no document number, revision or issue date (the PDF metadata carries a 2012 date, which is not printed). One table covers three cells; each record takes its own column (read from the rendered page: the columns follow the header order LSE110, LSE145, LSE190). Capacity and energy are printed as 'Nameplate' and 'BOL'; both are filed, with no rate, temperature or cut-off because the table states none. The three 'Max.' current rows are filed as printed (continuous charge, continuous discharge, and pulse discharge for 5 seconds), with the test temperature unstated. The 'End of Charge' and 'End of Discharge' voltages are filed as the charge and discharge cut-off voltages and keep their printed labels in extra. The chemistry row ('Lithium Cobalt Oxide') is one merged cell across all three columns of this table. Height is printed 'Height *' with the footnote '* Excluding terminals'. Not recorded: the 'Space Qualified' row, page 2 (cycling and model graphs; their conditions belong to the plotted test cells, not to the table). The form factor is the library's classification; the sheet prints 'Wound prismatic construction' and 'Anodized aluminum case and cover'.
Source document date
Not recorded (evidence)
Source revision
Not recorded
Specification source retrieved
2026-11-13 (day precision) (evidence)
Product lifecycle checked
Not recorded
Product release
Not researched
Date context
Source retrieval and document revision do not establish product release or current availability.
Record id
cell/gs-yuasa-lithium-power/lse110

How to cite

GS Yuasa Lithium Power. “GS Yuasa Lithium Power, Lithium Ion Cells For Satellites - Energy Optimized (LSE Gen III: LSE110, LSE145, LSE190)”, datasheet. https://gsyuasa-lp.com/SpecSheets/GS_Yuasa_LSE_GEN_III_Energy.pdf (retrieved 2026-11-13). Values as compiled in the Lemonergy battery library, record cell/gs-yuasa-lithium-power/lse110: https://lemonergy.com/data/batteries/gs-yuasa-lithium-power/lse110/

The values are CC BY 4.0; the document and the passages quoted from it belong to its publisher. All sources of the library

Suppliers of this product