lemonergy/ data

GS Yuasa Lithium Power LSE134

134 Ah LCO prismatic cell.

Every value read from the datasheet, with the conditions it was stated at.

Compare in the finderSource documentRecord as JSON (API)Report a correction

Capacity
134Ah
Nominal voltage
3.7V
Energy
496Wh
Mass
3.53kg
Specific energy
155Wh/kg
Energy density
349Wh/L
Dimensions
271 × 130 × 50mm
Continuous discharge
134 A · 1C
Operating temperature1
−10 to 35°C
  1. 1Operating temperature: discharge; charge 10 to 35 °C.
  2. Not stated by the source: cycle life, internal resistance.

Specifications

Every value, with its conditions. 19 quantities stated by the datasheet, grouped as in the finder. Conditions are the rate, temperature and limits each value was stated at.

Current and power

Continuous discharge current
134 A
maximum value. Not stated: temperature
Max. Continuous Discharge Current (A) | 76.5 | 150 | 134 · page 1, Cell Specifications table, column LSE134 (third of LSE51, LSE102, LSE134)
Continuous charge current
67 A
maximum value. Not stated: temperature
Max. Continuous Charge Current (A) | 25.5 | 50 | 67 · page 1, Cell Specifications table, column LSE134 (third of LSE51, LSE102, LSE134)
Pulse discharge current
402 A
5 s pulse · maximum value. Not stated: temperature
Max. Pulse Discharge Current (A) (5 seconds) | 153 | 300 | 402 · page 1, Cell Specifications table, column LSE134 (third of LSE51, LSE102, LSE134)

Density

Specific energy
155 Wh/kg
Not stated: rate, temperature
Specific Energy at BOL (Wh/kg) | 139 | 152 | 155 · page 1, Cell Specifications table, column LSE134 (third of LSE51, LSE102, LSE134)
Energy density
349 Wh/L
Not stated: rate, temperature
Energy Density at BOL (Wh/L) | 289 | 337 | 349 · page 1, Cell Specifications table, column LSE134 (third of LSE51, LSE102, LSE134)

Electrical

Nominal voltage
3.7 V
nominal value
Nominal Voltage (V) | 3.7 | 3.7 | 3.7 · page 1, Cell Specifications table, column LSE134 (third of LSE51, LSE102, LSE134)
Capacity
134 Ah
rated value. Not stated: rate, temperature, discharge cut-off voltage
Capacity (Ah) | Nameplate | 51 | 102 | 134 · page 1, Cell Specifications table, column LSE134 (third of LSE51, LSE102, LSE134)
Capacity
148 Ah
initial value. Not stated: rate, temperature, discharge cut-off voltage
BOL | 57 | 114 | 148 · page 1, Cell Specifications table, column LSE134 (third of LSE51, LSE102, LSE134)
Charge cutoff voltage
4.1 V
standard value
End of Charge (V) | 4.1 | 4.1 | 4.1 · page 1, Cell Specifications table, column LSE134 (third of LSE51, LSE102, LSE134)
Discharge cutoff voltage
2.75 V
standard value
End of Discharge (V) | 2.75 | 2.75 | 2.75 · page 1, Cell Specifications table, column LSE134 (third of LSE51, LSE102, LSE134)
Energy
496 Wh
rated value. Not stated: rate, temperature
Energy (Wh) | Nameplate | 189 | 377 | 496 · page 1, Cell Specifications table, column LSE134 (third of LSE51, LSE102, LSE134)
Energy
548 Wh
initial value. Not stated: rate, temperature
BOL | 211 | 422 | 548 · page 1, Cell Specifications table, column LSE134 (third of LSE51, LSE102, LSE134)

Physical

Mass
3.53 kg
nominal value
Weight (kg) | 1.52 | 2.77 | 3.53 · page 1, Cell Specifications table, column LSE134 (third of LSE51, LSE102, LSE134)
Height
271 mm
nominal value
Height * | 131 | 216 | 271 · page 1, Cell Specifications table, column LSE134 (third of LSE51, LSE102, LSE134)
Width
130 mm
nominal value
Dimensions (mm) | Width | 130 | 130 | 130 · page 1, Cell Specifications table, column LSE134 (third of LSE51, LSE102, LSE134)
Thickness
50 mm
nominal value
Thickness | 50 | 50 | 50 · page 1, Cell Specifications table, column LSE134 (third of LSE51, LSE102, LSE134)
Volume
1.57 L
nominal value
Volume (L) | 0.73 | 1.25 | 1.57 · page 1, Cell Specifications table, column LSE134 (third of LSE51, LSE102, LSE134)

Thermal and safety

Operating temperature, min
10 °C
charge · minimum value. Not stated: temperature reference
Charge | 10 ~ 35 | 10 ~ 35 | 10 ~ 35 · page 1, Cell Specifications table, column LSE134 (third of LSE51, LSE102, LSE134)
Operating temperature, min
−10 °C
discharge · minimum value. Not stated: temperature reference
Discharge | -10 ~ 35 | -10 ~ 35 | -10 ~ 35 · page 1, Cell Specifications table, column LSE134 (third of LSE51, LSE102, LSE134)
Operating temperature, max
35 °C
charge · maximum value. Not stated: temperature reference
Same passage as operating temperature, min · page 1, Cell Specifications table, column LSE134 (third of LSE51, LSE102, LSE134)
Operating temperature, max
35 °C
discharge · maximum value. Not stated: temperature reference
Same passage as operating temperature, min · page 1, Cell Specifications table, column LSE134 (third of LSE51, LSE102, LSE134)
Storage temperature min
−10 °C
minimum value. Not stated: duration
Storage | -10 ~ 10 | -10 ~ 10 | -10 ~ 10 · page 1, Cell Specifications table, column LSE134 (third of LSE51, LSE102, LSE134)
Storage temperature max
10 °C
maximum value. Not stated: duration
Same passage as storage temperature min · page 1, Cell Specifications table, column LSE134 (third of LSE51, LSE102, LSE134)

More documents

11 further values from 3 documents. Read from other documents for the same battery and kept apart from the values above, each with its own conditions and passage. A document independent of the maker gives its own findings, not the maker's ratings.

A third-party test independent of the maker: Dalton, P. J., North, T. (2017), International Space Station Lithium-Ion Main Battery Thermal Runaway Propagation Test, NASA Battery Workshop (presentation), NASA Technical Reports Server 20180000927 (2017-11-14): 2 values. Under Public domain (U.S. government work): please cite its authors when you reuse these values. Record file: review/revisions/gs-yuasa-lithium-power/lse134-dalton-2017-ntrs-iss-propagation.yaml.

Thermal and safety

Mass loss
90.7 %
calculated value. Not stated: state of charge
Cell #1 remains 328 ... Pretest Mass 3526 · page 19, Post-test destructive physical analysis, mass table
Share of tests that propagated
0 %
measured value. Not stated: state of charge
No propagation to neighboring cells · page 21, Test results

A third-party test independent of the maker: Graika, J., Barrera, T. P. & Alobaidi, Y. (2019), Effect of Mechanical Stress Factors on Large Format Li-Ion Cell Thermal Runaway Characteristics, 235th Meeting of The Electrochemical Society (presentation), NASA Technical Reports Server 20190025416 (2019-05-26): 8 values. Under Public domain (U.S. government work): please cite its authors when you reuse these values. Record file: review/revisions/gs-yuasa-lithium-power/lse134-graika-2019-ntrs-compression-tr.yaml.

Thermal and safety

Max runaway temperature
267 °C
measured value. Not stated: state of charge
Maximum Temperature, oC · page 15, Effect of Cell Compression Load on TR Severity
Max runaway temperature
431 °C
measured value. Not stated: state of charge
Same passage as max runaway temperature · page 15, Effect of Cell Compression Load on TR Severity
Max runaway temperature
422 °C
measured value. Not stated: state of charge
Same passage as max runaway temperature · page 15, Effect of Cell Compression Load on TR Severity
Max runaway temperature
543 °C
measured value. Not stated: state of charge
Same passage as max runaway temperature · page 15, Effect of Cell Compression Load on TR Severity
Max runaway temperature
620 °C
measured value. Not stated: state of charge
Same passage as max runaway temperature · page 15, Effect of Cell Compression Load on TR Severity
Max runaway temperature
651 °C
measured value. Not stated: state of charge
Same passage as max runaway temperature · page 15, Effect of Cell Compression Load on TR Severity
Max runaway temperature
219 °C
measured value. Not stated: state of charge
Same passage as max runaway temperature · page 15, Effect of Cell Compression Load on TR Severity
Max runaway temperature
338 °C
measured value. Not stated: state of charge
Same passage as max runaway temperature · page 15, Effect of Cell Compression Load on TR Severity

A third-party test independent of the maker: Kilzer, A., Miller, T. (2026), Final Performance Report on ISS Life Cycle Ground Testing on GS Yuasa 134 Ahr Lithium-ion Battery Cells, NASA Aerospace Battery Workshop, Huntsville, AL, 17 November 2026 (presentation; Naval Surface Warfare Center Crane and NASA Glenn Research Center), NASA Technical Reports Server 20260010633 (2026-11-17): 1 value. Under Public domain (U.S. government work): please cite its authors when you reuse these values. Record file: review/revisions/gs-yuasa-lithium-power/lse134-kilzer-2026-ntrs-life-cycle.yaml.

Lifetime

Cycle life
≥ 71,400 cycles
measured value. Not stated: temperature, depth of discharge, rate
Qualification pack F1SS01 demonstrated 71,400 cycles (12.2 years) without failure. · page 20, Conclusions

Chemistry

What it is made of. Classified as Lithium-ion · LCO.

Classified as
Lithium-ion · LCO
Designation
LCO
Cathode
Lithium Cobalt Oxide

Chemistry | Lithium Cobalt Oxide

Source and dates

One document behind every value. Each value above is read from it, and quoted where the record holds the passage.

Document
GS Yuasa Lithium Power, Lithium Ion Cells For Satellites - Power Optimized (LSE Gen III: LSE51, LSE102, LSE134)
Kind
datasheet
SHA-256
f9b2e1f86aed1f03fa891e48c6e899f30f8bc0ffc150c6e6a5b52b4ccbb847ea
Note
Two-page GS Yuasa Lithium Power data sheet, served by the maker's own website (gsyuasa-lp.com, Spec Sheets & SDS page, file GS_Yuasa_LSE_GEN_III_Power.pdf). It prints no document number, revision or issue date (the PDF metadata carries a 2012 date, which is not printed). One table covers three cells; each record takes its own column (read from the rendered page: the columns follow the header order LSE51, LSE102, LSE134). Capacity and energy are printed as 'Nameplate' and 'BOL'; both are filed, with no rate, temperature or cut-off because the table states none. The three 'Max.' current rows are filed as printed (continuous charge, continuous discharge, and pulse discharge for 5 seconds), with the test temperature unstated. The 'End of Charge' and 'End of Discharge' voltages are filed as the charge and discharge cut-off voltages and keep their printed labels in extra. The chemistry row ('Lithium Cobalt Oxide') is one merged cell across all three columns of this table. Height is printed 'Height *' with the footnote '* Excluding terminals'. Not recorded: the 'Space Qualified' row, page 2 (cycling and model graphs; their conditions belong to the plotted test cells, not to the table). The form factor is the library's classification; the sheet prints 'Wound prismatic construction' and 'Anodized aluminum case and cover'.
Source document date
Not recorded (evidence)
Source revision
Not recorded
Specification source retrieved
2026-11-13 (day precision) (evidence)
Product lifecycle checked
Not recorded
Product release
Not researched
Date context
Source retrieval and document revision do not establish product release or current availability.
Record id
cell/gs-yuasa-lithium-power/lse134

How to cite

GS Yuasa Lithium Power. “GS Yuasa Lithium Power, Lithium Ion Cells For Satellites - Power Optimized (LSE Gen III: LSE51, LSE102, LSE134)”, datasheet. https://gsyuasa-lp.com/SpecSheets/GS_Yuasa_LSE_GEN_III_Power.pdf (retrieved 2026-11-13). Values as compiled in the Lemonergy battery library, record cell/gs-yuasa-lithium-power/lse134: https://lemonergy.com/data/batteries/gs-yuasa-lithium-power/lse134/

The values are CC BY 4.0; the document and the passages quoted from it belong to its publisher. All sources of the library

Suppliers of this product

No supplier has listed this product yet. Do you supply it? Write to [email protected].