Samsung SDI 94Ah
94 Ah prismatic cell.
Every value read from the datasheet (dated 2015), with the conditions it was stated at.
Compare in the finderSource documentRecord as JSON (API)Report a correction
- Capacity1
- 94Ah
- Nominal voltage
- 3.68V
- Energy2
- 345Wh
- Mass
- 2.1kg
- Specific energy3
- 164Wh/kg
- Energy density4
- 355Wh/L
- Dimensions
- 125 × 173 × 45mm
- Continuous discharge5
- 150 A · 1.6C
- Cycle life6
- 3,200cycles
- Operating temperature
- −40 to 60°C
- 1Capacity: C/3 · 25 °C.
- 2Energy: C/3 · 25 °C.
- 3Specific energy: calculated by Lemonergy from stated values.
- 4Energy density: calculated by Lemonergy from stated values.
- 5Continuous discharge: 25 °C.
- 6Cycle life: 1 C.
- Not stated by the source: internal resistance.
Curves
217 curves from 4 documents. A further source for this battery, the maker's datasheet: Samsung SDI, Introduction of Samsung SDI's 94Ah cells (slide deck, 31 Dec 2015): its graphs and its printed tables of OCV, rate capability, DC-IR and power, self-discharge and operating limits, plots 105 curves; they are drawn below with its name on each figure. A further source for this battery, a journal article independent of the maker: Hassini, M., Redondo-Iglesias, E., Venet, P. (2023), Second-Life Batteries Modeling for Performance Tracking in a Mobile Charging Station, World Electric Vehicle Journal 14(4): 94 (CC BY 4.0), plots 6 curves; they are drawn below with its name on each figure. A further source for this battery, a journal article independent of the maker: Hassini, M., Redondo-Iglesias, E., Venet, P. (2024), Battery Passports for Second-Life Batteries: An Experimental Assessment of Suitability for Mobile Applications, Batteries 10(5): 153 (CC BY 4.0), plots 36 curves; they are drawn below with its name on each figure. A further source for this battery, a dataset independent of the maker: Hassini, M., Redondo-Iglesias, E., Venet, P. (2026), Characterisation tests of three retired Samsung SDI 94Ah modules, version 1, Recherche Data Gouv, Université Gustave Eiffel (Licence Ouverte 2.0 (Etalab): credit Univ. Gustave Eiffel and the date of the data's last update (19 June 2026)), plots 70 curves; they are drawn below with its name on each figure.
Open-circuit voltage
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-introduction-2015-12-31-figures.yaml.Table: 4 lines
| Line | Points | Notes |
|---|---|---|
| Discharge | 54 | |
| Charge | 54 | |
| Discharge, printed table | 11 | |
| Charge, printed table | 11 |
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-introduction-2015-12-31-figures.yaml.Table: 8 lines
| Line | Points | Notes |
|---|---|---|
| 40 °C | 24 | |
| 25 °C | 24 | |
| −10 °C | 24 | |
| −25 °C | 24 | |
| 40 °C, printed table | 11 | |
| 25 °C, printed table | 11 | |
| −10 °C, printed table | 11 | |
| −25 °C, printed table | 11 |
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-hassini-2023-wevj.yaml.Table: 3 lines
| Line | Points | Notes |
|---|---|---|
| 40 °C | 98 | |
| 25 °C | 96 | |
| 0 °C | 99 |
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-hassini-2024-batteries.yaml.Table: 12 lines
| Line | Points | Notes |
|---|---|---|
| Cell, line 1 of 12 | 80 | |
| Cell, line 2 of 12 | 91 | |
| Cell, line 3 of 12 | 80 | |
| Cell, line 4 of 12 | 88 | |
| Cell, line 5 of 12 | 82 | |
| Cell, line 6 of 12 | 82 | |
| Cell, line 7 of 12 | 78 | |
| Cell, line 8 of 12 | 92 | |
| Cell, line 9 of 12 | 83 | |
| Cell, line 10 of 12 | 92 | |
| Cell, line 11 of 12 | 91 | |
| Cell, line 12 of 12 | 70 |
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-hassini-2026-recherche-data-gouv.yaml.Table: 12 lines
| Line | Points | Notes |
|---|---|---|
| M1_H1 | 98 | |
| M1_H2 | 99 | |
| M1_H3 | 98 | |
| M1_H4 | 98 | |
| M1_H5 | 93 | |
| M1_H6 | 97 | |
| M1_L1 | 98 | |
| M1_L2 | 98 | |
| M1_L3 | 97 | |
| M1_L4 | 99 | |
| M1_L5 | 100 | |
| M1_L6 | 96 |
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-hassini-2026-recherche-data-gouv.yaml.Table: 12 lines
| Line | Points | Notes |
|---|---|---|
| M2_H1 | 97 | |
| M2_H2 | 94 | |
| M2_H3 | 94 | |
| M2_H4 | 95 | |
| M2_H5 | 95 | |
| M2_H6 | 96 | |
| M2_L1 | 95 | |
| M2_L2 | 95 | |
| M2_L3 | 95 | |
| M2_L4 | 95 | |
| M2_L5 | 93 | |
| M2_L6 | 95 |
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-hassini-2026-recherche-data-gouv.yaml.Table: 11 lines
| Line | Points | Notes |
|---|---|---|
| M3_H2 | 96 | |
| M3_H3 | 96 | |
| M3_H4 | 96 | |
| M3_H5 | 96 | |
| M3_H6 | 96 | |
| M3_L1 | 97 | |
| M3_L2 | 97 | |
| M3_L3 | 97 | |
| M3_L4 | 97 | |
| M3_L5 | 97 | |
| M3_L6 | 97 |
Discharge
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-introduction-2015-12-31-figures.yaml.Table: 6 lines
| Line | Points | Notes |
|---|---|---|
| 0.1C | 133 | |
| 0.3C | 92 | |
| 0.5C | 90 | |
| 1C | 94 | |
| 2C | 87 | |
| 3C | 90 |
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-introduction-2015-12-31-figures.yaml.Table: 6 lines
| Line | Points | Notes |
|---|---|---|
| 0.1C | 137 | |
| 0.3C | 92 | |
| 0.5C | 82 | |
| 1C | 83 | |
| 2C | 80 | |
| 3C | 88 |
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-introduction-2015-12-31-figures.yaml.Table: 6 lines
| Line | Points | Notes |
|---|---|---|
| 0.1C | 117 | |
| 0.3C | 92 | |
| 0.5C | 80 | |
| 1C | 85 | |
| 2C | 86 | |
| 3C | 87 |
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-introduction-2015-12-31-figures.yaml.Table: 5 lines
| Line | Points | Notes |
|---|---|---|
| 0.1C | 126 | |
| 0.3C | 97 | |
| 0.5C | 81 | |
| 1C | 88 | |
| 2C | 89 |
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-introduction-2015-12-31-figures.yaml.Table: 4 lines
| Line | Points | Notes |
|---|---|---|
| 0.1C | 107 | |
| 0.3C | 94 | |
| 0.5C | 89 | |
| 1C | 90 |
Charge
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-introduction-2015-12-31-figures.yaml.Table: 8 lines
| Line | Points | Notes |
|---|---|---|
| 0.1C | 130 | |
| 0.2C | 92 | |
| 0.3C | 89 | |
| 0.5C | 114 | |
| 1C | 102 | |
| 2C | 101 | |
| 3C | 98 | |
| 4C | 101 |
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-introduction-2015-12-31-figures.yaml.Table: 8 lines
| Line | Points | Notes |
|---|---|---|
| 0.1C | 134 | |
| 0.2C | 104 | |
| 0.3C | 102 | |
| 0.5C | 81 | |
| 1C | 104 | |
| 2C | 104 | |
| 3C | 99 | |
| 4C | 150 |
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-introduction-2015-12-31-figures.yaml.Table: 8 lines
| Line | Points | Notes |
|---|---|---|
| 0.1C | 123 | |
| 0.2C | 103 | |
| 0.3C | 113 | |
| 0.5C | 142 | |
| 1C | 158 | |
| 2C | 118 | |
| 3C | 116 | |
| 4C | 117 |
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-introduction-2015-12-31-figures.yaml.Table: 3 lines
| Line | Points | Notes |
|---|---|---|
| 0.1C | 173 | |
| 0.3C | 118 | |
| 0.5C | 90 |
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-introduction-2015-12-31-figures.yaml.Table: 3 lines
| Line | Points | Notes |
|---|---|---|
| 0.025C | 663 | |
| 0.05C | 596 | |
| 0.1C | 168 |
Resistance
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-introduction-2015-12-31-figures.yaml.Table: 4 lines
| Line | Points | Notes |
|---|---|---|
| 40 °C | 12 | |
| 25 °C | 12 | |
| −10 °C | 12 | |
| −25 °C | 12 |
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-introduction-2015-12-31-figures.yaml.Table: 4 lines
| Line | Points | Notes |
|---|---|---|
| 40 °C | 12 | |
| 25 °C | 12 | |
| −10 °C | 12 | |
| −25 °C | 12 |
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-hassini-2023-wevj.yaml.Table: 3 lines
| Line | Points | Notes |
|---|---|---|
| 40 °C | 10 | |
| 25 °C | 10 | |
| 0 °C | 10 |
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-hassini-2024-batteries.yaml.Table: 12 lines
| Line | Points | Notes |
|---|---|---|
| Most degraded cell, upper line | 9 | |
| Most degraded cell, middle line | 9 | |
| Most degraded cell, lower line | 9 | |
| Other cell, line 1 of 9 | 9 | |
| Other cell, line 2 of 9 | 10 | |
| Other cell, line 3 of 9 | 10 | |
| Other cell, line 4 of 9 | 10 | |
| Other cell, line 5 of 9 | 9 | |
| Other cell, line 6 of 9 | 10 | |
| Other cell, line 7 of 9 | 10 | |
| Other cell, line 8 of 9 | 9 | |
| Other cell, line 9 of 9 | 10 |
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-hassini-2024-batteries.yaml.Table: 12 lines
| Line | Points | Notes |
|---|---|---|
| Most degraded cell, upper line | 9 | |
| Most degraded cell, middle line | 9 | |
| Most degraded cell, lower line | 9 | |
| Other cell, line 1 of 9 | 9 | |
| Other cell, line 2 of 9 | 9 | |
| Other cell, line 3 of 9 | 7 | |
| Other cell, line 4 of 9 | 9 | |
| Other cell, line 5 of 9 | 9 | |
| Other cell, line 6 of 9 | 9 | |
| Other cell, line 7 of 9 | 9 | |
| Other cell, line 8 of 9 | 7 | |
| Other cell, line 9 of 9 | 9 |
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-hassini-2026-recherche-data-gouv.yaml.Table: 11 lines
| Line | Points | Notes |
|---|---|---|
| M1_H1 | 9 | |
| M1_H2 | 9 | |
| M1_H3 | 9 | |
| M1_H4 | 9 | |
| M1_H5 | 9 | |
| M1_H6 | 9 | |
| M1_L1 | 9 | |
| M1_L2 | 9 | |
| M1_L4 | 9 | |
| M1_L5 | 9 | |
| M1_L6 | 5 |
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-hassini-2026-recherche-data-gouv.yaml.Table: 12 lines
| Line | Points | Notes |
|---|---|---|
| M2_H1 | 7 | |
| M2_H2 | 6 | |
| M2_H3 | 6 | |
| M2_H4 | 7 | |
| M2_H5 | 7 | |
| M2_H6 | 7 | |
| M2_L1 | 8 | |
| M2_L2 | 8 | |
| M2_L3 | 6 | |
| M2_L4 | 9 | |
| M2_L5 | 8 | |
| M2_L6 | 7 |
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-hassini-2026-recherche-data-gouv.yaml.Table: 12 lines
| Line | Points | Notes |
|---|---|---|
| M3_H1 | 7 | |
| M3_H2 | 7 | |
| M3_H3 | 7 | |
| M3_H4 | 7 | |
| M3_H5 | 7 | |
| M3_H6 | 7 | |
| M3_L1 | 7 | |
| M3_L2 | 7 | |
| M3_L3 | 8 | |
| M3_L4 | 7 | |
| M3_L5 | 7 | |
| M3_L6 | 7 |
Cycle life
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-introduction-2015-12-31-figures.yaml.Table: 2 lines
| Line | Points | Notes |
|---|---|---|
| B2 sample | 19 | |
| C sample | 20 |
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-introduction-2015-12-31-figures.yaml.Table: 2 lines
| Line | Points | Notes |
|---|---|---|
| B2 sample | 18 | |
| C sample | 17 |
review/revisions/samsung-sdi/94ah-introduction-2015-12-31-figures.yaml.Table: 1 line
| Line | Points | Notes |
|---|---|---|
| Capacity | 18 |
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-introduction-2015-12-31-figures.yaml.Table: 2 lines
| Line | Points | Notes |
|---|---|---|
| Capacity_Rigid jig | 16 | |
| Capacity_flexible jig | 20 |
Calendar life
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-introduction-2015-12-31-figures.yaml.Table: 2 lines
| Line | Points | Notes |
|---|---|---|
| B2 sample | 19 | |
| C sample | 16 |
Fast charge
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-introduction-2015-12-31-figures.yaml.Table: 6 lines
| Line | Points | Notes |
|---|---|---|
| 500W 0% | 15 | |
| 500W 5% | 15 | |
| 500W 10% | 11 | |
| 500W 20% | 15 | |
| 500W 30% | 15 | |
| 500W 100% | 7 |
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-introduction-2015-12-31-figures.yaml.Table: 6 lines
| Line | Points | Notes |
|---|---|---|
| 500W 0% | 15 | |
| 500W 5% | 15 | |
| 500W 10% | 11 | |
| 500W 20% | 15 | |
| 500W 30% | 15 | |
| 500W 100% | 7 |
Self-discharge
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-introduction-2015-12-31-figures.yaml.Table: 4 lines
| Line | Points | Notes |
|---|---|---|
| 20 % SoC | 22 | |
| 40 % SoC | 21 | |
| 60 % SoC | 23 | |
| 100 % SoC | 20 |
Select a line to hide or show it; double-click to see it alone.
review/revisions/samsung-sdi/94ah-introduction-2015-12-31-figures.yaml.Table: 3 lines
| Line | Points | Notes |
|---|---|---|
| 20 % SoC | 8 | |
| 40 % SoC | 23 | |
| 60 % SoC | 17 |
Specifications
Every value, with its conditions. 15 quantities stated by the datasheet, grouped as in the finder. Conditions are the rate, temperature and limits each value was stated at.
Current and power
- Continuous discharge current
- 150 A
- 25 °C · maximum value
Continuous 25oC A 150
· page 5, printed page 6, Summary of cell performance- Continuous charge current
- 72 A
- 25 °C · maximum value
Continuous 25oC A 72
· page 5, printed page 6, Summary of cell performance- Pulse discharge current
- 409 A
- 25 °C · maximum value. Not stated: pulse duration
Peak 25oC A 409
· page 5, printed page 6, Summary of cell performance
Electrical
- Nominal voltage
- 3.68 V
- nominal value
Nominal voltage - V 3.68
· page 5, printed page 6, Summary of cell performance- Capacity
- 94 Ah
- C/3 · 25 °C · minimum value. Not stated: discharge cut-off voltage
Capacity (min.) 1/3C rate, 25oC, Discharge Ah 94
· page 5, printed page 6, Summary of cell performance- Charge cutoff voltage
- 4.15 V
- maximum value
Operating voltage - V 2.7 ~ 4.15
· page 5, printed page 6, Summary of cell performance- Discharge cutoff voltage
- 2.7 V
- minimum value
- Same passage as charge cutoff voltage · page 5, printed page 6, Summary of cell performance
- Energy
- 345 Wh
- C/3 · 25 °C · minimum value
Energy (min.) 1/3C rate, 25oC, Discharge Wh 345
· page 5, printed page 6, Summary of cell performance
Lifetime
- Cycle life
- 3,200 cycles
- 1 C · rated value. Not stated: temperature, depth of discharge
Cycle life 0.5C/1C, RT, EOL80%/EOL70% cycles 3,200 / 5,200
· page 5, printed page 6, Summary of cell performance- Cycle life
- 5,200 cycles
- 1 C · rated value. Not stated: temperature, depth of discharge
- Same passage as cycle life · page 5, printed page 6, Summary of cell performance
- Cycle life
- 1,500 cycles
- 1 C · 45 °C · rated value. Not stated: depth of discharge
1C/1C, 45oC, EOL80%/EOL70% cycles 1,500 / 2,500
· page 5, printed page 6, Summary of cell performance- Cycle life
- 2,500 cycles
- 1 C · 45 °C · rated value. Not stated: depth of discharge
- Same passage as cycle life · page 5, printed page 6, Summary of cell performance
Physical
- Mass
- 2.1 kg
- maximum value
Cell weight (max.) Bare cell kg 2.1
· page 5, printed page 6, Summary of cell performance- Height
- 125 mm
- nominal value
Size Width x height x Thickness mm 173 x 125 x 45
· page 5, printed page 6, Summary of cell performance- Width
- 173 mm
- nominal value
- Same passage as height · page 5, printed page 6, Summary of cell performance
- Thickness
- 45 mm
- nominal value
- Same passage as height · page 5, printed page 6, Summary of cell performance
Thermal and safety
- Operating temperature, min
- −40 °C
- minimum value. Not stated: temperature reference, direction
Operating temperature - oC -40 ~ 60
· page 5, printed page 6, Summary of cell performance- Operating temperature, max
- 60 °C
- maximum value. Not stated: temperature reference, direction
- Same passage as operating temperature, min · page 5, printed page 6, Summary of cell performance
More documents
377 further values from 5 documents. Read from other documents for the same battery and kept apart from the values above, each with its own conditions and passage. A document independent of the maker gives its own findings, not the maker's ratings.
The maker's datasheet: Samsung SDI, Introduction of Samsung SDI's 94Ah cells (slide deck, 31 Dec 2015): its graphs and its printed tables of OCV, rate capability, DC-IR and power, self-discharge and operating limits (2015-12-31): 347 values. Record file: review/revisions/samsung-sdi/94ah-introduction-2015-12-31-figures.yaml.
Current and power
- Continuous discharge current
- 223 A
- 60 °C · maximum value. Not stated: temperature reference, state of charge
Discharge Operating Current Limit | Temperature (℃) 60 | Idch_max_peak (A) 409 | Duration (sec) 150 | Irms (A) 223 | Allowable usages over life 100%
· page 42, Operating current limit, Discharge Operating Current Limit, row 60 ℃ (PDF page 42)- Continuous discharge current
- 223 A
- 50 °C · maximum value. Not stated: temperature reference, state of charge
Discharge Operating Current Limit | Temperature (℃) 50 | Idch_max_peak (A) 409 | Duration (sec) 150 | Irms (A) 223 | Allowable usages over life 100%
· page 42, Operating current limit, Discharge Operating Current Limit, row 50 ℃ (PDF page 42)- Continuous discharge current
- 223 A
- 40 °C · maximum value. Not stated: temperature reference, state of charge
Discharge Operating Current Limit | Temperature (℃) 40 | Idch_max_peak (A) 409 | Duration (sec) 150 | Irms (A) 223 | Allowable usages over life 100%
· page 42, Operating current limit, Discharge Operating Current Limit, row 40 ℃ (PDF page 42)- Continuous discharge current
- 210 A
- 35 °C · maximum value. Not stated: temperature reference, state of charge
Discharge Operating Current Limit | Temperature (℃) 35 | Idch_max_peak (A) 409 | Duration (sec) 150 | Irms (A) 210 | Allowable usages over life 100%
· page 42, Operating current limit, Discharge Operating Current Limit, row 35 ℃ (PDF page 42)- Continuous discharge current
- 196 A
- 30 °C · maximum value. Not stated: temperature reference, state of charge
Discharge Operating Current Limit | Temperature (℃) 30 | Idch_max_peak (A) 409 | Duration (sec) 150 | Irms (A) 196 | Allowable usages over life 100%
· page 42, Operating current limit, Discharge Operating Current Limit, row 30 ℃ (PDF page 42)- Continuous discharge current
- 180 A
- 25 °C · maximum value. Not stated: temperature reference, state of charge
Discharge Operating Current Limit | Temperature (℃) 25 | Idch_max_peak (A) 409 | Duration (sec) 150 | Irms (A) 180 | Allowable usages over life 100%
· page 42, Operating current limit, Discharge Operating Current Limit, row 25 ℃ (PDF page 42)- Continuous discharge current
- 166 A
- 20 °C · maximum value. Not stated: temperature reference, state of charge
Discharge Operating Current Limit | Temperature (℃) 20 | Idch_max_peak (A) 409 | Duration (sec) 150 | Irms (A) 166 | Allowable usages over life 100%
· page 42, Operating current limit, Discharge Operating Current Limit, row 20 ℃ (PDF page 42)- Continuous discharge current
- 153 A
- 15 °C · maximum value. Not stated: temperature reference, state of charge
Discharge Operating Current Limit | Temperature (℃) 15 | Idch_max_peak (A) 409 | Duration (sec) 150 | Irms (A) 153 | Allowable usages over life 100%
· page 42, Operating current limit, Discharge Operating Current Limit, row 15 ℃ (PDF page 42)- Continuous discharge current
- 136 A
- 10 °C · maximum value. Not stated: temperature reference, state of charge
Discharge Operating Current Limit | Temperature (℃) 10 | Idch_max_peak (A) 409 | Duration (sec) 150 | Irms (A) 136 | Allowable usages over life 100%
· page 42, Operating current limit, Discharge Operating Current Limit, row 10 ℃ (PDF page 42)- Continuous discharge current
- 124 A
- 5 °C · maximum value. Not stated: temperature reference, state of charge
Discharge Operating Current Limit | Temperature (℃) 5 | Idch_max_peak (A) 409 | Duration (sec) 150 | Irms (A) 124 | Allowable usages over life 100%
· page 42, Operating current limit, Discharge Operating Current Limit, row 5 ℃ (PDF page 42)- Continuous discharge current
- 108 A
- 0 °C · maximum value. Not stated: temperature reference, state of charge
Discharge Operating Current Limit | Temperature (℃) 0 | Idch_max_peak (A) 409 | Duration (sec) 150 | Irms (A) 108 | Allowable usages over life 100%
· page 42, Operating current limit, Discharge Operating Current Limit, row 0 ℃ (PDF page 42)- Continuous discharge current
- 93 A
- -5 °C · maximum value. Not stated: temperature reference, state of charge
Discharge Operating Current Limit | Temperature (℃) -5 | Idch_max_peak (A) 409 | Duration (sec) 150 | Irms (A) 93 | Allowable usages over life 100%
· page 42, Operating current limit, Discharge Operating Current Limit, row -5 ℃ (PDF page 42)- Continuous discharge current
- 77 A
- -10 °C · maximum value. Not stated: temperature reference, state of charge
Discharge Operating Current Limit | Temperature (℃) -10 | Idch_max_peak (A) 409 | Duration (sec) 150 | Irms (A) 77 | Allowable usages over life 100%
· page 42, Operating current limit, Discharge Operating Current Limit, row -10 ℃ (PDF page 42)- Continuous discharge current
- 74 A
- -15 °C · maximum value. Not stated: temperature reference, state of charge
Discharge Operating Current Limit | Temperature (℃) -15 | Idch_max_peak (A) 409 | Duration (sec) 150 | Irms (A) 74 | Allowable usages over life 100%
· page 42, Operating current limit, Discharge Operating Current Limit, row -15 ℃ (PDF page 42)- Continuous discharge current
- 62 A
- -20 °C · maximum value. Not stated: temperature reference, state of charge
Discharge Operating Current Limit | Temperature (℃) -20 | Idch_max_peak (A) 409 | Duration (sec) 150 | Irms (A) 62 | Allowable usages over life 100%
· page 42, Operating current limit, Discharge Operating Current Limit, row -20 ℃ (PDF page 42)- Continuous discharge current
- 57 A
- -25 °C · maximum value. Not stated: temperature reference, state of charge
Discharge Operating Current Limit | Temperature (℃) -25 | Idch_max_peak (A) 409 | Duration (sec) 150 | Irms (A) 57 | Allowable usages over life 100%
· page 42, Operating current limit, Discharge Operating Current Limit, row -25 ℃ (PDF page 42)- Continuous discharge current
- 46 A
- -30 °C · maximum value. Not stated: temperature reference, state of charge
Discharge Operating Current Limit | Temperature (℃) -30 | Idch_max_peak (A) 409 | Duration (sec) 150 | Irms (A) 46 | Allowable usages over life 100%
· page 42, Operating current limit, Discharge Operating Current Limit, row -30 ℃ (PDF page 42)- Continuous discharge current
- 33 A
- -40 °C · maximum value. Not stated: temperature reference, state of charge
Discharge Operating Current Limit | Temperature (℃) -40 | Idch_max_peak (A) 409 | Duration (sec) 150 | Irms (A) 33 | Allowable usages over life 100%
· page 42, Operating current limit, Discharge Operating Current Limit, row -40 ℃ (PDF page 42)- Continuous charge current
- 107 A
- 60 °C · maximum value. Not stated: temperature reference, state of charge
Charge Operating Current Limit | Temperature (℃) 60 | Ich_max_peak (A) 270 | Duration (sec) 100 | Irms (A) 107 | Allowable usages over life 100%
· page 42, Operating current limit, Charge Operating Current Limit, row 60 ℃ (PDF page 42)- Continuous charge current
- 107 A
- 50 °C · maximum value. Not stated: temperature reference, state of charge
Charge Operating Current Limit | Temperature (℃) 50 | Ich_max_peak (A) 270 | Duration (sec) 100 | Irms (A) 107 | Allowable usages over life 100%
· page 42, Operating current limit, Charge Operating Current Limit, row 50 ℃ (PDF page 42)- Continuous charge current
- 96 A
- 40 °C · maximum value. Not stated: temperature reference, state of charge
Charge Operating Current Limit | Temperature (℃) 40 | Ich_max_peak (A) 270 | Duration (sec) 100 | Irms (A) 96 | Allowable usages over life 100%
· page 42, Operating current limit, Charge Operating Current Limit, row 40 ℃ (PDF page 42)- Continuous charge current
- 84 A
- 35 °C · maximum value. Not stated: temperature reference, state of charge
Charge Operating Current Limit | Temperature (℃) 35 | Ich_max_peak (A) 270 | Duration (sec) 100 | Irms (A) 84 | Allowable usages over life 100%
· page 42, Operating current limit, Charge Operating Current Limit, row 35 ℃ (PDF page 42)- Continuous charge current
- 73 A
- 30 °C · maximum value. Not stated: temperature reference, state of charge
Charge Operating Current Limit | Temperature (℃) 30 | Ich_max_peak (A) 270 | Duration (sec) 100 | Irms (A) 73 | Allowable usages over life 100%
· page 42, Operating current limit, Charge Operating Current Limit, row 30 ℃ (PDF page 42)- Continuous charge current
- 61 A
- 25 °C · maximum value. Not stated: temperature reference, state of charge
Charge Operating Current Limit | Temperature (℃) 25 | Ich_max_peak (A) 270 | Duration (sec) 100 | Irms (A) 61 | Allowable usages over life 100%
· page 42, Operating current limit, Charge Operating Current Limit, row 25 ℃ (PDF page 42)- Continuous charge current
- 51 A
- 20 °C · maximum value. Not stated: temperature reference, state of charge
Charge Operating Current Limit | Temperature (℃) 20 | Ich_max_peak (A) 270 | Duration (sec) 100 | Irms (A) 51 | Allowable usages over life 100%
· page 42, Operating current limit, Charge Operating Current Limit, row 20 ℃ (PDF page 42)- Continuous charge current
- 41 A
- 15 °C · maximum value. Not stated: temperature reference, state of charge
Charge Operating Current Limit | Temperature (℃) 15 | Ich_max_peak (A) 270 | Duration (sec) 100 | Irms (A) 41 | Allowable usages over life 100%
· page 42, Operating current limit, Charge Operating Current Limit, row 15 ℃ (PDF page 42)- Continuous charge current
- 32 A
- 10 °C · maximum value. Not stated: temperature reference, state of charge
Charge Operating Current Limit | Temperature (℃) 10 | Ich_max_peak (A) 270 | Duration (sec) 100 | Irms (A) 32 | Allowable usages over life 100%
· page 42, Operating current limit, Charge Operating Current Limit, row 10 ℃ (PDF page 42)- Continuous charge current
- 24 A
- 5 °C · maximum value. Not stated: temperature reference, state of charge
Charge Operating Current Limit | Temperature (℃) 5 | Ich_max_peak (A) 270 | Duration (sec) 100 | Irms (A) 24 | Allowable usages over life 100%
· page 42, Operating current limit, Charge Operating Current Limit, row 5 ℃ (PDF page 42)- Continuous charge current
- 18 A
- 0 °C · maximum value. Not stated: temperature reference, state of charge
Charge Operating Current Limit | Temperature (℃) 0 | Ich_max_peak (A) 237 | Duration (sec) 100 | Irms (A) 18 | Allowable usages over life 100%
· page 42, Operating current limit, Charge Operating Current Limit, row 0 ℃ (PDF page 42)- Continuous charge current
- 12 A
- -5 °C · maximum value. Not stated: temperature reference, state of charge
Charge Operating Current Limit | Temperature (℃) -5 | Ich_max_peak (A) 185 | Duration (sec) 100 | Irms (A) 12 | Allowable usages over life 100%
· page 42, Operating current limit, Charge Operating Current Limit, row -5 ℃ (PDF page 42)- Continuous charge current
- 7.2 A
- -10 °C · maximum value. Not stated: temperature reference, state of charge
Charge Operating Current Limit | Temperature (℃) -10 | Ich_max_peak (A) 125 | Duration (sec) 100 | Irms (A) 7.2 | Allowable usages over life 100%
· page 42, Operating current limit, Charge Operating Current Limit, row -10 ℃ (PDF page 42)- Continuous charge current
- 4.3 A
- -15 °C · maximum value. Not stated: temperature reference, state of charge
Charge Operating Current Limit | Temperature (℃) -15 | Ich_max_peak (A) 62 | Duration (sec) 100 | Irms (A) 4.3 | Allowable usages over life 100%
· page 42, Operating current limit, Charge Operating Current Limit, row -15 ℃ (PDF page 42)- Continuous charge current
- 2.7 A
- -20 °C · maximum value. Not stated: temperature reference, state of charge
Charge Operating Current Limit | Temperature (℃) -20 | Ich_max_peak (A) 33 | Duration (sec) 100 | Irms (A) 2.7 | Allowable usages over life 100%
· page 42, Operating current limit, Charge Operating Current Limit, row -20 ℃ (PDF page 42)- Continuous charge current
- 1.7 A
- -25 °C · maximum value. Not stated: temperature reference, state of charge
Charge Operating Current Limit | Temperature (℃) -25 | Ich_max_peak (A) 22 | Duration (sec) 100 | Irms (A) 1.7 | Allowable usages over life 100%
· page 42, Operating current limit, Charge Operating Current Limit, row -25 ℃ (PDF page 42)- Continuous charge current
- 1 A
- -30 °C · maximum value. Not stated: temperature reference, state of charge
Charge Operating Current Limit | Temperature (℃) -30 | Ich_max_peak (A) 7 | Duration (sec) 100 | Irms (A) 1.0 | Allowable usages over life 100%
· page 42, Operating current limit, Charge Operating Current Limit, row -30 ℃ (PDF page 42)- Continuous charge current
- 0.4 A
- -40 °C · maximum value. Not stated: temperature reference, state of charge
Charge Operating Current Limit | Temperature (℃) -40 | Ich_max_peak (A) 1 | Duration (sec) 100 | Irms (A) 0.4 | Allowable usages over life 100%
· page 42, Operating current limit, Charge Operating Current Limit, row -40 ℃ (PDF page 42)- Peak power
- 1,617 W
- 40 °C · 100 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 100 | Power (W) 1617 | Max current 413 A
· page 14, Power and DC-IR @ 5sec discharge, 40℃, 413A: table under the figures, row Power (W), column 100 % SOC (PDF page 14)- Peak power
- 1,589 W
- 40 °C · 95 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 95 | Power (W) 1589 | Max current 413 A
· page 14, Power and DC-IR @ 5sec discharge, 40℃, 413A: table under the figures, row Power (W), column 95 % SOC (PDF page 14)- Peak power
- 1,568 W
- 40 °C · 90 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 90 | Power (W) 1568 | Max current 413 A
· page 14, Power and DC-IR @ 5sec discharge, 40℃, 413A: table under the figures, row Power (W), column 90 % SOC (PDF page 14)- Peak power
- 1,528 W
- 40 °C · 80 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 80 | Power (W) 1528 | Max current 413 A
· page 14, Power and DC-IR @ 5sec discharge, 40℃, 413A: table under the figures, row Power (W), column 80 % SOC (PDF page 14)- Peak power
- 1,492 W
- 40 °C · 70 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 70 | Power (W) 1492 | Max current 413 A
· page 14, Power and DC-IR @ 5sec discharge, 40℃, 413A: table under the figures, row Power (W), column 70 % SOC (PDF page 14)- Peak power
- 1,465 W
- 40 °C · 60 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 60 | Power (W) 1465 | Max current 413 A
· page 14, Power and DC-IR @ 5sec discharge, 40℃, 413A: table under the figures, row Power (W), column 60 % SOC (PDF page 14)- Peak power
- 1,436 W
- 40 °C · 50 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 50 | Power (W) 1436 | Max current 413 A
· page 14, Power and DC-IR @ 5sec discharge, 40℃, 413A: table under the figures, row Power (W), column 50 % SOC (PDF page 14)- Peak power
- 1,422 W
- 40 °C · 40 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 40 | Power (W) 1422 | Max current 413 A
· page 14, Power and DC-IR @ 5sec discharge, 40℃, 413A: table under the figures, row Power (W), column 40 % SOC (PDF page 14)- Peak power
- 1,410 W
- 40 °C · 30 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 30 | Power (W) 1410 | Max current 413 A
· page 14, Power and DC-IR @ 5sec discharge, 40℃, 413A: table under the figures, row Power (W), column 30 % SOC (PDF page 14)- Peak power
- 1,393 W
- 40 °C · 20 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 20 | Power (W) 1393 | Max current 413 A
· page 14, Power and DC-IR @ 5sec discharge, 40℃, 413A: table under the figures, row Power (W), column 20 % SOC (PDF page 14)- Peak power
- 1,348 W
- 40 °C · 10 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 10 | Power (W) 1348 | Max current 413 A
· page 14, Power and DC-IR @ 5sec discharge, 40℃, 413A: table under the figures, row Power (W), column 10 % SOC (PDF page 14)- Peak power
- 1,312 W
- 40 °C · 5 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 5 | Power (W) 1312 | Max current 413 A
· page 14, Power and DC-IR @ 5sec discharge, 40℃, 413A: table under the figures, row Power (W), column 5 % SOC (PDF page 14)- Peak power
- 1,151 W
- 40 °C · 100 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 100 | Power (W) 1151 | Max current 294 A
· page 15, Power and DC-IR @ 30sec discharge, 40℃, 294A: table under the figures, row Power (W), column 100 % SOC (PDF page 15)- Peak power
- 1,131 W
- 40 °C · 95 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 95 | Power (W) 1131 | Max current 294 A
· page 15, Power and DC-IR @ 30sec discharge, 40℃, 294A: table under the figures, row Power (W), column 95 % SOC (PDF page 15)- Peak power
- 1,117 W
- 40 °C · 90 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 90 | Power (W) 1117 | Max current 294 A
· page 15, Power and DC-IR @ 30sec discharge, 40℃, 294A: table under the figures, row Power (W), column 90 % SOC (PDF page 15)- Peak power
- 1,089 W
- 40 °C · 80 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 80 | Power (W) 1089 | Max current 294 A
· page 15, Power and DC-IR @ 30sec discharge, 40℃, 294A: table under the figures, row Power (W), column 80 % SOC (PDF page 15)- Peak power
- 1,065 W
- 40 °C · 70 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 70 | Power (W) 1065 | Max current 294 A
· page 15, Power and DC-IR @ 30sec discharge, 40℃, 294A: table under the figures, row Power (W), column 70 % SOC (PDF page 15)- Peak power
- 1,046 W
- 40 °C · 60 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 60 | Power (W) 1046 | Max current 294 A
· page 15, Power and DC-IR @ 30sec discharge, 40℃, 294A: table under the figures, row Power (W), column 60 % SOC (PDF page 15)- Peak power
- 1,027 W
- 40 °C · 50 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 50 | Power (W) 1027 | Max current 294 A
· page 15, Power and DC-IR @ 30sec discharge, 40℃, 294A: table under the figures, row Power (W), column 50 % SOC (PDF page 15)- Peak power
- 1,018 W
- 40 °C · 40 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 40 | Power (W) 1018 | Max current 294 A
· page 15, Power and DC-IR @ 30sec discharge, 40℃, 294A: table under the figures, row Power (W), column 40 % SOC (PDF page 15)- Peak power
- 1,009 W
- 40 °C · 30 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 30 | Power (W) 1009 | Max current 294 A
· page 15, Power and DC-IR @ 30sec discharge, 40℃, 294A: table under the figures, row Power (W), column 30 % SOC (PDF page 15)- Peak power
- 992 W
- 40 °C · 20 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 20 | Power (W) 992 | Max current 294 A
· page 15, Power and DC-IR @ 30sec discharge, 40℃, 294A: table under the figures, row Power (W), column 20 % SOC (PDF page 15)- Peak power
- 955 W
- 40 °C · 10 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 10 | Power (W) 955 | Max current 294 A
· page 15, Power and DC-IR @ 30sec discharge, 40℃, 294A: table under the figures, row Power (W), column 10 % SOC (PDF page 15)- Peak power
- 889 W
- 40 °C · 5 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 5 | Power (W) 889 | Max current 294 A
· page 15, Power and DC-IR @ 30sec discharge, 40℃, 294A: table under the figures, row Power (W), column 5 % SOC (PDF page 15)- Peak power
- 1,593 W
- 25 °C · 100 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 100 | Power (W) 1593 | Max current 413 A
· page 16, Power and DC-IR @ 5sec discharge, 25℃, 413A: table under the figures, row Power (W), column 100 % SOC (PDF page 16)- Peak power
- 1,571 W
- 25 °C · 95 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 95 | Power (W) 1571 | Max current 413 A
· page 16, Power and DC-IR @ 5sec discharge, 25℃, 413A: table under the figures, row Power (W), column 95 % SOC (PDF page 16)- Peak power
- 1,549 W
- 25 °C · 90 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 90 | Power (W) 1549 | Max current 413 A
· page 16, Power and DC-IR @ 5sec discharge, 25℃, 413A: table under the figures, row Power (W), column 90 % SOC (PDF page 16)- Peak power
- 1,507 W
- 25 °C · 80 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 80 | Power (W) 1507 | Max current 413 A
· page 16, Power and DC-IR @ 5sec discharge, 25℃, 413A: table under the figures, row Power (W), column 80 % SOC (PDF page 16)- Peak power
- 1,471 W
- 25 °C · 70 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 70 | Power (W) 1471 | Max current 413 A
· page 16, Power and DC-IR @ 5sec discharge, 25℃, 413A: table under the figures, row Power (W), column 70 % SOC (PDF page 16)- Peak power
- 1,442 W
- 25 °C · 60 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 60 | Power (W) 1442 | Max current 413 A
· page 16, Power and DC-IR @ 5sec discharge, 25℃, 413A: table under the figures, row Power (W), column 60 % SOC (PDF page 16)- Peak power
- 1,411 W
- 25 °C · 50 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 50 | Power (W) 1411 | Max current 413 A
· page 16, Power and DC-IR @ 5sec discharge, 25℃, 413A: table under the figures, row Power (W), column 50 % SOC (PDF page 16)- Peak power
- 1,394 W
- 25 °C · 40 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 40 | Power (W) 1394 | Max current 413 A
· page 16, Power and DC-IR @ 5sec discharge, 25℃, 413A: table under the figures, row Power (W), column 40 % SOC (PDF page 16)- Peak power
- 1,380 W
- 25 °C · 30 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 30 | Power (W) 1380 | Max current 413 A
· page 16, Power and DC-IR @ 5sec discharge, 25℃, 413A: table under the figures, row Power (W), column 30 % SOC (PDF page 16)- Peak power
- 1,360 W
- 25 °C · 20 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 20 | Power (W) 1360 | Max current 413 A
· page 16, Power and DC-IR @ 5sec discharge, 25℃, 413A: table under the figures, row Power (W), column 20 % SOC (PDF page 16)- Peak power
- 1,286 W
- 25 °C · 10 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 10 | Power (W) 1286 | Max current 413 A
· page 16, Power and DC-IR @ 5sec discharge, 25℃, 413A: table under the figures, row Power (W), column 10 % SOC (PDF page 16)- Peak power
- 1,125 W
- 25 °C · 5 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 5 | Power (W) 1125 | Max current 413 A
· page 16, Power and DC-IR @ 5sec discharge, 25℃, 413A: table under the figures, row Power (W), column 5 % SOC (PDF page 16)- Peak power
- 1,135 W
- 25 °C · 100 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 100 | Power (W) 1135 | Max current 294 A
· page 17, Power and DC-IR @ 30sec discharge, 25℃, 294A: table under the figures, row Power (W), column 100 % SOC (PDF page 17)- Peak power
- 1,119 W
- 25 °C · 95 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 95 | Power (W) 1119 | Max current 294 A
· page 17, Power and DC-IR @ 30sec discharge, 25℃, 294A: table under the figures, row Power (W), column 95 % SOC (PDF page 17)- Peak power
- 1,104 W
- 25 °C · 90 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 90 | Power (W) 1104 | Max current 294 A
· page 17, Power and DC-IR @ 30sec discharge, 25℃, 294A: table under the figures, row Power (W), column 90 % SOC (PDF page 17)- Peak power
- 1,075 W
- 25 °C · 80 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 80 | Power (W) 1075 | Max current 294 A
· page 17, Power and DC-IR @ 30sec discharge, 25℃, 294A: table under the figures, row Power (W), column 80 % SOC (PDF page 17)- Peak power
- 1,050 W
- 25 °C · 70 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 70 | Power (W) 1050 | Max current 294 A
· page 17, Power and DC-IR @ 30sec discharge, 25℃, 294A: table under the figures, row Power (W), column 70 % SOC (PDF page 17)- Peak power
- 1,030 W
- 25 °C · 60 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 60 | Power (W) 1030 | Max current 294 A
· page 17, Power and DC-IR @ 30sec discharge, 25℃, 294A: table under the figures, row Power (W), column 60 % SOC (PDF page 17)- Peak power
- 1,010 W
- 25 °C · 50 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 50 | Power (W) 1010 | Max current 294 A
· page 17, Power and DC-IR @ 30sec discharge, 25℃, 294A: table under the figures, row Power (W), column 50 % SOC (PDF page 17)- Peak power
- 999 W
- 25 °C · 40 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 40 | Power (W) 999 | Max current 294 A
· page 17, Power and DC-IR @ 30sec discharge, 25℃, 294A: table under the figures, row Power (W), column 40 % SOC (PDF page 17)- Peak power
- 988 W
- 25 °C · 30 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 30 | Power (W) 988 | Max current 294 A
· page 17, Power and DC-IR @ 30sec discharge, 25℃, 294A: table under the figures, row Power (W), column 30 % SOC (PDF page 17)- Peak power
- 969 W
- 25 °C · 20 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 20 | Power (W) 969 | Max current 294 A
· page 17, Power and DC-IR @ 30sec discharge, 25℃, 294A: table under the figures, row Power (W), column 20 % SOC (PDF page 17)- Peak power
- 873 W
- 25 °C · 10 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 10 | Power (W) 873 | Max current 294 A
· page 17, Power and DC-IR @ 30sec discharge, 25℃, 294A: table under the figures, row Power (W), column 10 % SOC (PDF page 17)- Peak power
- 550 W
- 25 °C · 5 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 5 | Power (W) 550 | Max current 294 A
· page 17, Power and DC-IR @ 30sec discharge, 25℃, 294A: table under the figures, row Power (W), column 5 % SOC (PDF page 17)- Peak power
- 1,330 W
- -10 °C · 100 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 100 | Power (W) 1330 | Max current 413 A
· page 18, Power and DC-IR @ 5sec discharge, -10℃, 413A: table under the figures, row Power (W), column 100 % SOC (PDF page 18)- Peak power
- 1,305 W
- -10 °C · 95 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 95 | Power (W) 1305 | Max current 413 A
· page 18, Power and DC-IR @ 5sec discharge, -10℃, 413A: table under the figures, row Power (W), column 95 % SOC (PDF page 18)- Peak power
- 1,282 W
- -10 °C · 90 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 90 | Power (W) 1282 | Max current 413 A
· page 18, Power and DC-IR @ 5sec discharge, -10℃, 413A: table under the figures, row Power (W), column 90 % SOC (PDF page 18)- Peak power
- 1,282 W
- -10 °C · 80 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 80 | Power (W) 1282 | Max current 413 A
· page 18, Power and DC-IR @ 5sec discharge, -10℃, 413A: table under the figures, row Power (W), column 80 % SOC (PDF page 18)- Peak power
- 1,194 W
- -10 °C · 70 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 70 | Power (W) 1194 | Max current 413 A
· page 18, Power and DC-IR @ 5sec discharge, -10℃, 413A: table under the figures, row Power (W), column 70 % SOC (PDF page 18)- Peak power
- 1,158 W
- -10 °C · 60 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 60 | Power (W) 1158 | Max current 413 A
· page 18, Power and DC-IR @ 5sec discharge, -10℃, 413A: table under the figures, row Power (W), column 60 % SOC (PDF page 18)- Peak power
- 1,115 W
- -10 °C · 50 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 50 | Power (W) 1115 | Max current 413 A
· page 18, Power and DC-IR @ 5sec discharge, -10℃, 413A: table under the figures, row Power (W), column 50 % SOC (PDF page 18)- Peak power
- 906 W
- -10 °C · 40 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 40 | Power (W) 906 | Max current 413 A
· page 18, Power and DC-IR @ 5sec discharge, -10℃, 413A: table under the figures, row Power (W), column 40 % SOC (PDF page 18)- Peak power
- 697 W
- -10 °C · 30 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 30 | Power (W) 697 | Max current 413 A
· page 18, Power and DC-IR @ 5sec discharge, -10℃, 413A: table under the figures, row Power (W), column 30 % SOC (PDF page 18)- Peak power
- 467 W
- -10 °C · 20 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 20 | Power (W) 467 | Max current 413 A
· page 18, Power and DC-IR @ 5sec discharge, -10℃, 413A: table under the figures, row Power (W), column 20 % SOC (PDF page 18)- Peak power
- 233 W
- -10 °C · 10 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 10 | Power (W) 233 | Max current 413 A
· page 18, Power and DC-IR @ 5sec discharge, -10℃, 413A: table under the figures, row Power (W), column 10 % SOC (PDF page 18)- Peak power
- 185 W
- -10 °C · 5 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 5 | Power (W) 185 | Max current 413 A
· page 18, Power and DC-IR @ 5sec discharge, -10℃, 413A: table under the figures, row Power (W), column 5 % SOC (PDF page 18)- Peak power
- 978 W
- -10 °C · 100 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 100 | Power (W) 978 | Max current 294 A
· page 19, Power and DC-IR @ 30sec discharge, -10℃, 294A: table under the figures, row Power (W), column 100 % SOC (PDF page 19)- Peak power
- 960 W
- -10 °C · 95 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 95 | Power (W) 960 | Max current 294 A
· page 19, Power and DC-IR @ 30sec discharge, -10℃, 294A: table under the figures, row Power (W), column 95 % SOC (PDF page 19)- Peak power
- 945 W
- -10 °C · 90 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 90 | Power (W) 945 | Max current 294 A
· page 19, Power and DC-IR @ 30sec discharge, -10℃, 294A: table under the figures, row Power (W), column 90 % SOC (PDF page 19)- Peak power
- 914 W
- -10 °C · 80 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 80 | Power (W) 914 | Max current 294 A
· page 19, Power and DC-IR @ 30sec discharge, -10℃, 294A: table under the figures, row Power (W), column 80 % SOC (PDF page 19)- Peak power
- 885 W
- -10 °C · 70 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 70 | Power (W) 885 | Max current 294 A
· page 19, Power and DC-IR @ 30sec discharge, -10℃, 294A: table under the figures, row Power (W), column 70 % SOC (PDF page 19)- Peak power
- 858 W
- -10 °C · 60 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 60 | Power (W) 858 | Max current 294 A
· page 19, Power and DC-IR @ 30sec discharge, -10℃, 294A: table under the figures, row Power (W), column 60 % SOC (PDF page 19)- Peak power
- 828 W
- -10 °C · 50 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 50 | Power (W) 828 | Max current 294 A
· page 19, Power and DC-IR @ 30sec discharge, -10℃, 294A: table under the figures, row Power (W), column 50 % SOC (PDF page 19)- Peak power
- 794 W
- -10 °C · 40 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 40 | Power (W) 794 | Max current 294 A
· page 19, Power and DC-IR @ 30sec discharge, -10℃, 294A: table under the figures, row Power (W), column 40 % SOC (PDF page 19)- Peak power
- 673 W
- -10 °C · 30 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 30 | Power (W) 673 | Max current 294 A
· page 19, Power and DC-IR @ 30sec discharge, -10℃, 294A: table under the figures, row Power (W), column 30 % SOC (PDF page 19)- Peak power
- 376 W
- -10 °C · 20 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 20 | Power (W) 376 | Max current 294 A
· page 19, Power and DC-IR @ 30sec discharge, -10℃, 294A: table under the figures, row Power (W), column 20 % SOC (PDF page 19)- Peak power
- 152 W
- -10 °C · 10 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 10 | Power (W) 152 | Max current 294 A
· page 19, Power and DC-IR @ 30sec discharge, -10℃, 294A: table under the figures, row Power (W), column 10 % SOC (PDF page 19)- Peak power
- 93 W
- -10 °C · 5 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 5 | Power (W) 93 | Max current 294 A
· page 19, Power and DC-IR @ 30sec discharge, -10℃, 294A: table under the figures, row Power (W), column 5 % SOC (PDF page 19)- Peak power
- 1,053 W
- -25 °C · 100 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 100 | Power (W) 1053 | Max current 413 A
· page 20, Power and DC-IR @ 5sec discharge, -25℃, 413A: table under the figures, row Power (W), column 100 % SOC (PDF page 20)- Peak power
- 1,029 W
- -25 °C · 95 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 95 | Power (W) 1029 | Max current 413 A
· page 20, Power and DC-IR @ 5sec discharge, -25℃, 413A: table under the figures, row Power (W), column 95 % SOC (PDF page 20)- Peak power
- 1,002 W
- -25 °C · 90 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 90 | Power (W) 1002 | Max current 413 A
· page 20, Power and DC-IR @ 5sec discharge, -25℃, 413A: table under the figures, row Power (W), column 90 % SOC (PDF page 20)- Peak power
- 955 W
- -25 °C · 80 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 80 | Power (W) 955 | Max current 413 A
· page 20, Power and DC-IR @ 5sec discharge, -25℃, 413A: table under the figures, row Power (W), column 80 % SOC (PDF page 20)- Peak power
- 902 W
- -25 °C · 70 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 70 | Power (W) 902 | Max current 413 A
· page 20, Power and DC-IR @ 5sec discharge, -25℃, 413A: table under the figures, row Power (W), column 70 % SOC (PDF page 20)- Peak power
- 850 W
- -25 °C · 60 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 60 | Power (W) 850 | Max current 413 A
· page 20, Power and DC-IR @ 5sec discharge, -25℃, 413A: table under the figures, row Power (W), column 60 % SOC (PDF page 20)- Peak power
- 783 W
- -25 °C · 50 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 50 | Power (W) 783 | Max current 413 A
· page 20, Power and DC-IR @ 5sec discharge, -25℃, 413A: table under the figures, row Power (W), column 50 % SOC (PDF page 20)- Peak power
- 584 W
- -25 °C · 40 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 40 | Power (W) 584 | Max current 413 A
· page 20, Power and DC-IR @ 5sec discharge, -25℃, 413A: table under the figures, row Power (W), column 40 % SOC (PDF page 20)- Peak power
- 387 W
- -25 °C · 30 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 30 | Power (W) 387 | Max current 413 A
· page 20, Power and DC-IR @ 5sec discharge, -25℃, 413A: table under the figures, row Power (W), column 30 % SOC (PDF page 20)- Peak power
- 218 W
- -25 °C · 20 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 20 | Power (W) 218 | Max current 413 A
· page 20, Power and DC-IR @ 5sec discharge, -25℃, 413A: table under the figures, row Power (W), column 20 % SOC (PDF page 20)- Peak power
- 153 W
- -25 °C · 10 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 10 | Power (W) 153 | Max current 413 A
· page 20, Power and DC-IR @ 5sec discharge, -25℃, 413A: table under the figures, row Power (W), column 10 % SOC (PDF page 20)- Peak power
- 181 W
- -25 °C · 5 % SoC · 5 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 5 | Power (W) 181 | Max current 413 A
· page 20, Power and DC-IR @ 5sec discharge, -25℃, 413A: table under the figures, row Power (W), column 5 % SOC (PDF page 20)- Peak power
- 846 W
- -25 °C · 100 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 100 | Power (W) 846 | Max current 294 A
· page 21, Power and DC-IR @ 30sec discharge, -25℃, 294A: table under the figures, row Power (W), column 100 % SOC (PDF page 21)- Peak power
- 826 W
- -25 °C · 95 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 95 | Power (W) 826 | Max current 294 A
· page 21, Power and DC-IR @ 30sec discharge, -25℃, 294A: table under the figures, row Power (W), column 95 % SOC (PDF page 21)- Peak power
- 804 W
- -25 °C · 90 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 90 | Power (W) 804 | Max current 294 A
· page 21, Power and DC-IR @ 30sec discharge, -25℃, 294A: table under the figures, row Power (W), column 90 % SOC (PDF page 21)- Peak power
- 771 W
- -25 °C · 80 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 80 | Power (W) 771 | Max current 294 A
· page 21, Power and DC-IR @ 30sec discharge, -25℃, 294A: table under the figures, row Power (W), column 80 % SOC (PDF page 21)- Peak power
- 736 W
- -25 °C · 70 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 70 | Power (W) 736 | Max current 294 A
· page 21, Power and DC-IR @ 30sec discharge, -25℃, 294A: table under the figures, row Power (W), column 70 % SOC (PDF page 21)- Peak power
- 701 W
- -25 °C · 60 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 60 | Power (W) 701 | Max current 294 A
· page 21, Power and DC-IR @ 30sec discharge, -25℃, 294A: table under the figures, row Power (W), column 60 % SOC (PDF page 21)- Peak power
- 644 W
- -25 °C · 50 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 50 | Power (W) 644 | Max current 294 A
· page 21, Power and DC-IR @ 30sec discharge, -25℃, 294A: table under the figures, row Power (W), column 50 % SOC (PDF page 21)- Peak power
- 607 W
- -25 °C · 40 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 40 | Power (W) 607 | Max current 294 A
· page 21, Power and DC-IR @ 30sec discharge, -25℃, 294A: table under the figures, row Power (W), column 40 % SOC (PDF page 21)- Peak power
- 305 W
- -25 °C · 30 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 30 | Power (W) 305 | Max current 294 A
· page 21, Power and DC-IR @ 30sec discharge, -25℃, 294A: table under the figures, row Power (W), column 30 % SOC (PDF page 21)- Peak power
- 161 W
- -25 °C · 20 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 20 | Power (W) 161 | Max current 294 A
· page 21, Power and DC-IR @ 30sec discharge, -25℃, 294A: table under the figures, row Power (W), column 20 % SOC (PDF page 21)- Peak power
- 78 W
- -25 °C · 10 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 10 | Power (W) 78 | Max current 294 A
· page 21, Power and DC-IR @ 30sec discharge, -25℃, 294A: table under the figures, row Power (W), column 10 % SOC (PDF page 21)- Peak power
- 62 W
- -25 °C · 5 % SoC · 30 s pulse · discharge · typical value. Not stated: temperature reference
SOC (%) 5 | Power (W) 62 | Max current 294 A
· page 21, Power and DC-IR @ 30sec discharge, -25℃, 294A: table under the figures, row Power (W), column 5 % SOC (PDF page 21)
Electrical
- Capacity
- 100.2 Ah
- 0.1 C · 40 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.1C | Discharge | Capacity | 100.2 Ah
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: discharge table under the figure, column 0.1C (PDF page 9)- Capacity
- 98.8 Ah
- 0.3 C · 40 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.3C | Discharge | Capacity | 98.8 Ah
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: discharge table under the figure, column 0.3C (PDF page 9)- Capacity
- 98.1 Ah
- 0.5 C · 40 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.5C | Discharge | Capacity | 98.1 Ah
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: discharge table under the figure, column 0.5C (PDF page 9)- Capacity
- 97 Ah
- 1 C · 40 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 1C | Discharge | Capacity | 97.0 Ah
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: discharge table under the figure, column 1C (PDF page 9)- Capacity
- 96.6 Ah
- 2 C · 40 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 2C | Discharge | Capacity | 96.6 Ah
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: discharge table under the figure, column 2C (PDF page 9)- Capacity
- 96.9 Ah
- 3 C · 40 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 3C | Discharge | Capacity | 96.9 Ah
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: discharge table under the figure, column 3C (PDF page 9)- Capacity
- 95.5 Ah
- 0.1 C · 40 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.1C | Charge (CC/CV) | Capacity | 95.5 Ah
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 0.1C (PDF page 9)- Capacity
- 94.8 Ah
- 0.1 C · 40 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.1C | Charge (CC) | Capacity | 94.8 Ah
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 0.1C (PDF page 9)- Capacity
- 95.4 Ah
- 0.2 C · 40 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.2C | Charge (CC/CV) | Capacity | 95.4 Ah
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 0.2C (PDF page 9)- Capacity
- 93.7 Ah
- 0.2 C · 40 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.2C | Charge (CC) | Capacity | 93.7 Ah
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 0.2C (PDF page 9)- Capacity
- 95.5 Ah
- 0.3 C · 40 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.3C | Charge (CC/CV) | Capacity | 95.5 Ah
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 0.3C (PDF page 9)- Capacity
- 92.4 Ah
- 0.3 C · 40 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.3C | Charge (CC) | Capacity | 92.4 Ah
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 0.3C (PDF page 9)- Capacity
- 95.6 Ah
- 0.5 C · 40 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.5C | Charge (CC/CV) | Capacity | 95.6 Ah
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 0.5C (PDF page 9)- Capacity
- 91.6 Ah
- 0.5 C · 40 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.5C | Charge (CC) | Capacity | 91.6 Ah
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 0.5C (PDF page 9)- Capacity
- 95.7 Ah
- 1 C · 40 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 1C | Charge (CC/CV) | Capacity | 95.7 Ah
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 1C (PDF page 9)- Capacity
- 88.2 Ah
- 1 C · 40 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 1C | Charge (CC) | Capacity | 88.2 Ah
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 1C (PDF page 9)- Capacity
- 95.8 Ah
- 2 C · 40 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 2C | Charge (CC/CV) | Capacity | 95.8 Ah
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 2C (PDF page 9)- Capacity
- 81.8 Ah
- 2 C · 40 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 2C | Charge (CC) | Capacity | 81.8 Ah
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 2C (PDF page 9)- Capacity
- 95.9 Ah
- 3 C · 40 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 3C | Charge (CC/CV) | Capacity | 95.9 Ah
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 3C (PDF page 9)- Capacity
- 76.5 Ah
- 3 C · 40 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 3C | Charge (CC) | Capacity | 76.5 Ah
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 3C (PDF page 9)- Capacity
- 96.9 Ah
- 4 C · 40 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 4C | Charge (CC/CV) | Capacity | 96.9 Ah
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 4C (PDF page 9)- Capacity
- 72.2 Ah
- 4 C · 40 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 4C | Charge (CC) | Capacity | 72.2 Ah
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 4C (PDF page 9)- Capacity
- 98.6 Ah
- 0.1 C · 25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.1C | Discharge | Capacity | 98.6 Ah
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: discharge table under the figure, column 0.1C (PDF page 10)- Capacity
- 95.5 Ah
- 0.3 C · 25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.3C | Discharge | Capacity | 95.5 Ah
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: discharge table under the figure, column 0.3C (PDF page 10)- Capacity
- 94.4 Ah
- 0.5 C · 25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.5C | Discharge | Capacity | 94.4 Ah
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: discharge table under the figure, column 0.5C (PDF page 10)- Capacity
- 93.1 Ah
- 1 C · 25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 1C | Discharge | Capacity | 93.1 Ah
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: discharge table under the figure, column 1C (PDF page 10)- Capacity
- 93.2 Ah
- 2 C · 25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 2C | Discharge | Capacity | 93.2 Ah
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: discharge table under the figure, column 2C (PDF page 10)- Capacity
- 93.9 Ah
- 3 C · 25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 3C | Discharge | Capacity | 93.9 Ah
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: discharge table under the figure, column 3C (PDF page 10)- Capacity
- 95.3 Ah
- 0.1 C · 25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.1C | Charge (CC/CV) | Capacity | 95.3 Ah
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 0.1C (PDF page 10)- Capacity
- 94.2 Ah
- 0.1 C · 25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.1C | Charge (CC) | Capacity | 94.2 Ah
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 0.1C (PDF page 10)- Capacity
- 95.1 Ah
- 0.2 C · 25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.2C | Charge (CC/CV) | Capacity | 95.1 Ah
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 0.2C (PDF page 10)- Capacity
- 92.4 Ah
- 0.2 C · 25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.2C | Charge (CC) | Capacity | 92.4 Ah
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 0.2C (PDF page 10)- Capacity
- 95.1 Ah
- 0.3 C · 25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.3C | Charge (CC/CV) | Capacity | 95.1 Ah
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 0.3C (PDF page 10)- Capacity
- 90.8 Ah
- 0.3 C · 25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.3C | Charge (CC) | Capacity | 90.8 Ah
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 0.3C (PDF page 10)- Capacity
- 95.1 Ah
- 0.5 C · 25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.5C | Charge (CC/CV) | Capacity | 95.1 Ah
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 0.5C (PDF page 10)- Capacity
- 89.2 Ah
- 0.5 C · 25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.5C | Charge (CC) | Capacity | 89.2 Ah
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 0.5C (PDF page 10)- Capacity
- 95.2 Ah
- 1 C · 25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 1C | Charge (CC/CV) | Capacity | 95.2 Ah
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 1C (PDF page 10)- Capacity
- 85 Ah
- 1 C · 25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 1C | Charge (CC) | Capacity | 85.0 Ah
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 1C (PDF page 10)- Capacity
- 95.3 Ah
- 2 C · 25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 2C | Charge (CC/CV) | Capacity | 95.3 Ah
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 2C (PDF page 10)- Capacity
- 78.6 Ah
- 2 C · 25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 2C | Charge (CC) | Capacity | 78.6 Ah
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 2C (PDF page 10)- Capacity
- 95.5 Ah
- 3 C · 25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 3C | Charge (CC/CV) | Capacity | 95.5 Ah
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 3C (PDF page 10)- Capacity
- 73.3 Ah
- 3 C · 25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 3C | Charge (CC) | Capacity | 73.3 Ah
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 3C (PDF page 10)- Capacity
- 95.6 Ah
- 4 C · 25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 4C | Charge (CC/CV) | Capacity | 95.6 Ah
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 4C (PDF page 10)- Capacity
- 68 Ah
- 4 C · 25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 4C | Charge (CC) | Capacity | 68.0 Ah
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 4C (PDF page 10)- Capacity
- 92.1 Ah
- 0.1 C · 5 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.1C | Discharge | Capacity | 92.1 Ah
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: discharge table under the figure, column 0.1C (PDF page 11)- Capacity
- 87.5 Ah
- 0.3 C · 5 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.3C | Discharge | Capacity | 87.5 Ah
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: discharge table under the figure, column 0.3C (PDF page 11)- Capacity
- 86.2 Ah
- 0.5 C · 5 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.5C | Discharge | Capacity | 86.2 Ah
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: discharge table under the figure, column 0.5C (PDF page 11)- Capacity
- 85.6 Ah
- 1 C · 5 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 1C | Discharge | Capacity | 85.6 Ah
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: discharge table under the figure, column 1C (PDF page 11)- Capacity
- 87.5 Ah
- 2 C · 5 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 2C | Discharge | Capacity | 87.5 Ah
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: discharge table under the figure, column 2C (PDF page 11)- Capacity
- 89.2 Ah
- 3 C · 5 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 3C | Discharge | Capacity | 89.2 Ah
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: discharge table under the figure, column 3C (PDF page 11)- Capacity
- 93.8 Ah
- 0.1 C · 5 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.1C | Charge (CC/CV) | Capacity | 93.8 Ah
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 0.1C (PDF page 11)- Capacity
- 91.6 Ah
- 0.1 C · 5 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.1C | Charge (CC) | Capacity | 91.6 Ah
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 0.1C (PDF page 11)- Capacity
- 93.7 Ah
- 0.2 C · 5 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.2C | Charge (CC/CV) | Capacity | 93.7 Ah
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 0.2C (PDF page 11)- Capacity
- 88.9 Ah
- 0.2 C · 5 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.2C | Charge (CC) | Capacity | 88.9 Ah
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 0.2C (PDF page 11)- Capacity
- 93.7 Ah
- 0.3 C · 5 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.3C | Charge (CC/CV) | Capacity | 93.7 Ah
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 0.3C (PDF page 11)- Capacity
- 86.6 Ah
- 0.3 C · 5 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.3C | Charge (CC) | Capacity | 86.6 Ah
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 0.3C (PDF page 11)- Capacity
- 93.7 Ah
- 0.5 C · 5 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.5C | Charge (CC/CV) | Capacity | 93.7 Ah
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 0.5C (PDF page 11)- Capacity
- 84 Ah
- 0.5 C · 5 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.5C | Charge (CC) | Capacity | 84.0 Ah
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 0.5C (PDF page 11)- Capacity
- 93.8 Ah
- 1 C · 5 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 1C | Charge (CC/CV) | Capacity | 93.8 Ah
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 1C (PDF page 11)- Capacity
- 79.1 Ah
- 1 C · 5 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 1C | Charge (CC) | Capacity | 79.1 Ah
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 1C (PDF page 11)- Capacity
- 94 Ah
- 2 C · 5 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 2C | Charge (CC/CV) | Capacity | 94.0 Ah
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 2C (PDF page 11)- Capacity
- 73.3 Ah
- 2 C · 5 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 2C | Charge (CC) | Capacity | 73.3 Ah
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 2C (PDF page 11)- Capacity
- 94.3 Ah
- 3 C · 5 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 3C | Charge (CC/CV) | Capacity | 94.3 Ah
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 3C (PDF page 11)- Capacity
- 65.3 Ah
- 3 C · 5 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 3C | Charge (CC) | Capacity | 65.3 Ah
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 3C (PDF page 11)- Capacity
- 94.3 Ah
- 4 C · 5 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 4C | Charge (CC/CV) | Capacity | 94.3 Ah
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 4C (PDF page 11)- Capacity
- 53.1 Ah
- 4 C · 5 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 4C | Charge (CC) | Capacity | 53.1 Ah
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 4C (PDF page 11)- Capacity
- 84.2 Ah
- 0.1 C · -10 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.1C | Discharge | Capacity | 84.2 Ah
· page 12, Rated Capacity, 0.1C ~2C rates @ -10℃: discharge table under the figure, column 0.1C (PDF page 12)- Capacity
- 79.9 Ah
- 0.3 C · -10 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.3C | Discharge | Capacity | 79.9 Ah
· page 12, Rated Capacity, 0.1C ~2C rates @ -10℃: discharge table under the figure, column 0.3C (PDF page 12)- Capacity
- 79.7 Ah
- 0.5 C · -10 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.5C | Discharge | Capacity | 79.7 Ah
· page 12, Rated Capacity, 0.1C ~2C rates @ -10℃: discharge table under the figure, column 0.5C (PDF page 12)- Capacity
- 81.7 Ah
- 1 C · -10 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 1C | Discharge | Capacity | 81.7 Ah
· page 12, Rated Capacity, 0.1C ~2C rates @ -10℃: discharge table under the figure, column 1C (PDF page 12)- Capacity
- 85.7 Ah
- 2 C · -10 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 2C | Discharge | Capacity | 85.7 Ah
· page 12, Rated Capacity, 0.1C ~2C rates @ -10℃: discharge table under the figure, column 2C (PDF page 12)- Capacity
- 91.4 Ah
- 0.1 C · -10 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.1C | Charge (CC/CV) | Capacity | 91.4 Ah
· page 12, Rated Capacity, 0.1C ~2C rates @ -10℃: charge table under the figure, column 0.1C (PDF page 12)- Capacity
- 86 Ah
- 0.1 C · -10 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.1C | Charge (CC) | Capacity | 86.0 Ah
· page 12, Rated Capacity, 0.1C ~2C rates @ -10℃: charge table under the figure, column 0.1C (PDF page 12)- Capacity
- 89.9 Ah
- 0.3 C · -10 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.3C | Charge (CC/CV) | Capacity | 89.9 Ah
· page 12, Rated Capacity, 0.1C ~2C rates @ -10℃: charge table under the figure, column 0.3C (PDF page 12)- Capacity
- 77.9 Ah
- 0.3 C · -10 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.3C | Charge (CC) | Capacity | 77.9 Ah
· page 12, Rated Capacity, 0.1C ~2C rates @ -10℃: charge table under the figure, column 0.3C (PDF page 12)- Capacity
- 89.5 Ah
- 0.5 C · -10 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.5C | Charge (CC/CV) | Capacity | 89.5 Ah
· page 12, Rated Capacity, 0.1C ~2C rates @ -10℃: charge table under the figure, column 0.5C (PDF page 12)- Capacity
- 75.8 Ah
- 0.5 C · -10 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.5C | Charge (CC) | Capacity | 75.8 Ah
· page 12, Rated Capacity, 0.1C ~2C rates @ -10℃: charge table under the figure, column 0.5C (PDF page 12)- Capacity
- 74.6 Ah
- 0.1 C · -25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.1C | Discharge | Capacity | 74.6 Ah
· page 13, Rated Capacity, 0.025C ~1C rates @ -25℃: discharge table under the figure, column 0.1C (PDF page 13)- Capacity
- 72 Ah
- 0.3 C · -25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.3C | Discharge | Capacity | 72.0 Ah
· page 13, Rated Capacity, 0.025C ~1C rates @ -25℃: discharge table under the figure, column 0.3C (PDF page 13)- Capacity
- 72.3 Ah
- 0.5 C · -25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.5C | Discharge | Capacity | 72.3 Ah
· page 13, Rated Capacity, 0.025C ~1C rates @ -25℃: discharge table under the figure, column 0.5C (PDF page 13)- Capacity
- 75 Ah
- 1 C · -25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 1C | Discharge | Capacity | 75.0 Ah
· page 13, Rated Capacity, 0.025C ~1C rates @ -25℃: discharge table under the figure, column 1C (PDF page 13)- Capacity
- 85.5 Ah
- 0.025 C · -25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.025C | Charge (CC/CV) | Capacity | 85.5 Ah
· page 13, Rated Capacity, 0.025C ~1C rates @ -25℃: charge table under the figure, column 0.025C (PDF page 13)- Capacity
- 84.7 Ah
- 0.025 C · -25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.025C | Charge (CC) | Capacity | 84.7 Ah
· page 13, Rated Capacity, 0.025C ~1C rates @ -25℃: charge table under the figure, column 0.025C (PDF page 13)- Capacity
- 85.3 Ah
- 0.05 C · -25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.05C | Charge (CC/CV) | Capacity | 85.3 Ah
· page 13, Rated Capacity, 0.025C ~1C rates @ -25℃: charge table under the figure, column 0.05C (PDF page 13)- Capacity
- 80.4 Ah
- 0.05 C · -25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.05C | Charge (CC) | Capacity | 80.4 Ah
· page 13, Rated Capacity, 0.025C ~1C rates @ -25℃: charge table under the figure, column 0.05C (PDF page 13)- Capacity
- 85.6 Ah
- 0.1 C · -25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.1C | Charge (CC/CV) | Capacity | 85.6 Ah
· page 13, Rated Capacity, 0.025C ~1C rates @ -25℃: charge table under the figure, column 0.1C (PDF page 13)- Capacity
- 75.4 Ah
- 0.1 C · -25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.1C | Charge (CC) | Capacity | 75.4 Ah
· page 13, Rated Capacity, 0.025C ~1C rates @ -25℃: charge table under the figure, column 0.1C (PDF page 13)- Charge cutoff voltage
- 4.15 V
- maximum value
Operating limit | Charge | 4.15 V
· page 45, Operating and safety voltage limit, table, Operating limit Charge (PDF page 45)- Discharge cutoff voltage
- 2.7 V
- minimum value
Operating limit | Discharge | 2.7 V | 2.1 V at below -20oC within 30 sec duration
· page 45, Operating and safety voltage limit, table, Operating limit Discharge (PDF page 45)- Discharge cutoff voltage
- 2.1 V
- temperature < -20 °C · minimum value
Operating limit | Discharge | 2.1 V | 2.1 V at below -20oC within 30 sec duration
· page 45, Operating and safety voltage limit, table, Operating limit Discharge (PDF page 45)- Absolute max voltage
- 4.25 V
- absolute maximum value
Safety limit | Charge | 4.25 V
· page 45, Operating and safety voltage limit, table, Safety limit Charge (PDF page 45)- Absolute min voltage
- 1.5 V
- absolute minimum value
Safety limit | Discharge | 1.5 V
· page 45, Operating and safety voltage limit, table, Safety limit Discharge (PDF page 45)- Energy
- 370 Wh
- 0.1 C · 40 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.1C | Discharge | Energy (Wh) | 370 Wh
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: discharge table under the figure, column 0.1C (PDF page 9)- Energy
- 363 Wh
- 0.3 C · 40 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.3C | Discharge | Energy (Wh) | 363 Wh
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: discharge table under the figure, column 0.3C (PDF page 9)- Energy
- 360 Wh
- 0.5 C · 40 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.5C | Discharge | Energy (Wh) | 360 Wh
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: discharge table under the figure, column 0.5C (PDF page 9)- Energy
- 352 Wh
- 1 C · 40 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 1C | Discharge | Energy (Wh) | 352 Wh
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: discharge table under the figure, column 1C (PDF page 9)- Energy
- 345 Wh
- 2 C · 40 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 2C | Discharge | Energy (Wh) | 345 Wh
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: discharge table under the figure, column 2C (PDF page 9)- Energy
- 339 Wh
- 3 C · 40 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 3C | Discharge | Energy (Wh) | 339 Wh
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: discharge table under the figure, column 3C (PDF page 9)- Energy
- 365 Wh
- 0.1 C · 25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.1C | Discharge | Energy (Wh) | 365 Wh
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: discharge table under the figure, column 0.1C (PDF page 10)- Energy
- 351 Wh
- 0.3 C · 25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.3C | Discharge | Energy (Wh) | 351 Wh
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: discharge table under the figure, column 0.3C (PDF page 10)- Energy
- 346 Wh
- 0.5 C · 25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.5C | Discharge | Energy (Wh) | 346 Wh
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: discharge table under the figure, column 0.5C (PDF page 10)- Energy
- 337 Wh
- 1 C · 25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 1C | Discharge | Energy (Wh) | 337 Wh
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: discharge table under the figure, column 1C (PDF page 10)- Energy
- 330 Wh
- 2 C · 25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 2C | Discharge | Energy (Wh) | 330 Wh
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: discharge table under the figure, column 2C (PDF page 10)- Energy
- 326 Wh
- 3 C · 25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 3C | Discharge | Energy (Wh) | 326 Wh
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: discharge table under the figure, column 3C (PDF page 10)- Energy
- 340 Wh
- 0.1 C · 5 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.1C | Discharge | Energy (Wh) | 340 Wh
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: discharge table under the figure, column 0.1C (PDF page 11)- Energy
- 320 Wh
- 0.3 C · 5 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.3C | Discharge | Energy (Wh) | 320 Wh
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: discharge table under the figure, column 0.3C (PDF page 11)- Energy
- 313 Wh
- 0.5 C · 5 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.5C | Discharge | Energy (Wh) | 313 Wh
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: discharge table under the figure, column 0.5C (PDF page 11)- Energy
- 305 Wh
- 1 C · 5 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 1C | Discharge | Energy (Wh) | 305 Wh
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: discharge table under the figure, column 1C (PDF page 11)- Energy
- 303 Wh
- 2 C · 5 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 2C | Discharge | Energy (Wh) | 303 Wh
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: discharge table under the figure, column 2C (PDF page 11)- Energy
- 301 Wh
- 3 C · 5 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 3C | Discharge | Energy (Wh) | 301 Wh
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: discharge table under the figure, column 3C (PDF page 11)- Energy
- 309 Wh
- 0.1 C · -10 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.1C | Discharge | Energy (Wh) | 309 Wh
· page 12, Rated Capacity, 0.1C ~2C rates @ -10℃: discharge table under the figure, column 0.1C (PDF page 12)- Energy
- 287 Wh
- 0.3 C · -10 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.3C | Discharge | Energy (Wh) | 287 Wh
· page 12, Rated Capacity, 0.1C ~2C rates @ -10℃: discharge table under the figure, column 0.3C (PDF page 12)- Energy
- 283 Wh
- 0.5 C · -10 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.5C | Discharge | Energy (Wh) | 283 Wh
· page 12, Rated Capacity, 0.1C ~2C rates @ -10℃: discharge table under the figure, column 0.5C (PDF page 12)- Energy
- 285 Wh
- 1 C · -10 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 1C | Discharge | Energy (Wh) | 285 Wh
· page 12, Rated Capacity, 0.1C ~2C rates @ -10℃: discharge table under the figure, column 1C (PDF page 12)- Energy
- 289 Wh
- 2 C · -10 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 2C | Discharge | Energy (Wh) | 289 Wh
· page 12, Rated Capacity, 0.1C ~2C rates @ -10℃: discharge table under the figure, column 2C (PDF page 12)- Energy
- 267 Wh
- 0.1 C · -25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.1C | Discharge | Energy (Wh) | 267 Wh
· page 13, Rated Capacity, 0.025C ~1C rates @ -25℃: discharge table under the figure, column 0.1C (PDF page 13)- Energy
- 250 Wh
- 0.3 C · -25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.3C | Discharge | Energy (Wh) | 250 Wh
· page 13, Rated Capacity, 0.025C ~1C rates @ -25℃: discharge table under the figure, column 0.3C (PDF page 13)- Energy
- 248 Wh
- 0.5 C · -25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.5C | Discharge | Energy (Wh) | 248 Wh
· page 13, Rated Capacity, 0.025C ~1C rates @ -25℃: discharge table under the figure, column 0.5C (PDF page 13)- Energy
- 252 Wh
- 1 C · -25 °C · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 1C | Discharge | Energy (Wh) | 252 Wh
· page 13, Rated Capacity, 0.025C ~1C rates @ -25℃: discharge table under the figure, column 1C (PDF page 13)
Lifetime
- Self discharge rate
- 3.2 %
- 25 °C · 100 % SoC · typical value. Not stated: temperature reference
SOC, % | △SOC after 200D | at 25℃ | at 10℃ | SOC100 | 3.2% | -
· page 40, Self discharge, at 25℃ / 10℃: table '△SOC after 200D', row SOC100, column at 25℃ (PDF page 40)- Self discharge rate
- 3.3 %
- 25 °C · 60 % SoC · typical value. Not stated: temperature reference
SOC, % | △SOC after 200D | at 25℃ | at 10℃ | SOC60 | 3.3% | 1.4%
· page 40, Self discharge, at 25℃ / 10℃: table '△SOC after 200D', row SOC60, column at 25℃ (PDF page 40)- Self discharge rate
- 1.4 %
- 10 °C · 60 % SoC · typical value. Not stated: temperature reference
- Same passage as self discharge rate · page 40, Self discharge, at 25℃ / 10℃: table '△SOC after 200D', row SOC60, column at 10℃ (PDF page 40)
- Self discharge rate
- 1.9 %
- 25 °C · 40 % SoC · typical value. Not stated: temperature reference
SOC, % | △SOC after 200D | at 25℃ | at 10℃ | SOC40 | 1.9% | 0.6%
· page 40, Self discharge, at 25℃ / 10℃: table '△SOC after 200D', row SOC40, column at 25℃ (PDF page 40)- Self discharge rate
- 0.6 %
- 10 °C · 40 % SoC · typical value. Not stated: temperature reference
- Same passage as self discharge rate · page 40, Self discharge, at 25℃ / 10℃: table '△SOC after 200D', row SOC40, column at 10℃ (PDF page 40)
- Self discharge rate
- 2 %
- 25 °C · 20 % SoC · typical value. Not stated: temperature reference
SOC, % | △SOC after 200D | at 25℃ | at 10℃ | SOC20 | 2.0% | 0.5%
· page 40, Self discharge, at 25℃ / 10℃: table '△SOC after 200D', row SOC20, column at 25℃ (PDF page 40)- Self discharge rate
- 0.5 %
- 10 °C · 20 % SoC · typical value. Not stated: temperature reference
- Same passage as self discharge rate · page 40, Self discharge, at 25℃ / 10℃: table '△SOC after 200D', row SOC20, column at 10℃ (PDF page 40)
Thermal and safety
- Storage temperature min
- −40 °C
- minimum value. Not stated: duration
Safety limit | Minimum storage | -40oC | This is to be ensured in an ambient temperature range
· page 46, Operating and safety temperature limit, table, Safety limit Minimum storage (PDF page 46)- Storage temperature max
- 80 °C
- maximum value. Not stated: duration
Safety limit | Maximum storage | 80oC | This is to be ensured in an ambient temperature range (Electrolyte gas generation, OSD deformation vent opening, leakage, etc.)
· page 46, Operating and safety temperature limit, table, Safety limit Maximum storage (PDF page 46)
Other recorded quantities
- Capacity, % of reference
- 101.4 %
- 0.1 C · 40 °C · discharge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.1C | Discharge | % (vs.1/3C) | 101.40%
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: discharge table under the figure, column 0.1C (PDF page 9)- Capacity, % of reference
- 100 %
- 0.3 C · 40 °C · discharge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.3C | Discharge | % (vs.1/3C) | 100.00%
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: discharge table under the figure, column 0.3C (PDF page 9)- Capacity, % of reference
- 99.3 %
- 0.5 C · 40 °C · discharge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.5C | Discharge | % (vs.1/3C) | 99.30%
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: discharge table under the figure, column 0.5C (PDF page 9)- Capacity, % of reference
- 98.2 %
- 1 C · 40 °C · discharge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 1C | Discharge | % (vs.1/3C) | 98.20%
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: discharge table under the figure, column 1C (PDF page 9)- Capacity, % of reference
- 97.8 %
- 2 C · 40 °C · discharge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 2C | Discharge | % (vs.1/3C) | 97.80%
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: discharge table under the figure, column 2C (PDF page 9)- Capacity, % of reference
- 98.1 %
- 3 C · 40 °C · discharge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 3C | Discharge | % (vs.1/3C) | 98.10%
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: discharge table under the figure, column 3C (PDF page 9)- Capacity, % of reference
- 100 %
- 0.1 C · 40 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.1C | Charge (CC/CV) | % (vs.1/3C) | 100.00%
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 0.1C (PDF page 9)- Capacity, % of reference
- 102.6 %
- 0.1 C · 40 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.1C | Charge (CC) | % (vs.1/3C) | 102.60%
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 0.1C (PDF page 9)- Capacity, % of reference
- 99.9 %
- 0.2 C · 40 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.2C | Charge (CC/CV) | % (vs.1/3C) | 99.90%
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 0.2C (PDF page 9)- Capacity, % of reference
- 101.4 %
- 0.2 C · 40 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.2C | Charge (CC) | % (vs.1/3C) | 101.40%
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 0.2C (PDF page 9)- Capacity, % of reference
- 100 %
- 0.3 C · 40 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.3C | Charge (CC/CV) | % (vs.1/3C) | 100.00%
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 0.3C (PDF page 9)- Capacity, % of reference
- 100 %
- 0.3 C · 40 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.3C | Charge (CC) | % (vs.1/3C) | 100.00%
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 0.3C (PDF page 9)- Capacity, % of reference
- 100.1 %
- 0.5 C · 40 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.5C | Charge (CC/CV) | % (vs.1/3C) | 100.10%
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 0.5C (PDF page 9)- Capacity, % of reference
- 99.1 %
- 0.5 C · 40 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.5C | Charge (CC) | % (vs.1/3C) | 99.10%
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 0.5C (PDF page 9)- Capacity, % of reference
- 100.2 %
- 1 C · 40 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 1C | Charge (CC/CV) | % (vs.1/3C) | 100.20%
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 1C (PDF page 9)- Capacity, % of reference
- 95.4 %
- 1 C · 40 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 1C | Charge (CC) | % (vs.1/3C) | 95.40%
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 1C (PDF page 9)- Capacity, % of reference
- 100.3 %
- 2 C · 40 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 2C | Charge (CC/CV) | % (vs.1/3C) | 100.30%
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 2C (PDF page 9)- Capacity, % of reference
- 88.5 %
- 2 C · 40 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 2C | Charge (CC) | % (vs.1/3C) | 88.50%
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 2C (PDF page 9)- Capacity, % of reference
- 100.4 %
- 3 C · 40 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 3C | Charge (CC/CV) | % (vs.1/3C) | 100.40%
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 3C (PDF page 9)- Capacity, % of reference
- 82.8 %
- 3 C · 40 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 3C | Charge (CC) | % (vs.1/3C) | 82.80%
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 3C (PDF page 9)- Capacity, % of reference
- 101.5 %
- 4 C · 40 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 4C | Charge (CC/CV) | % (vs.1/3C) | 101.50%
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 4C (PDF page 9)- Capacity, % of reference
- 78.2 %
- 4 C · 40 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 4C | Charge (CC) | % (vs.1/3C) | 78.20%
· page 9, Rated Capacity, 0.1C ~4C rates @ 40℃: charge table under the figure, column 4C (PDF page 9)- Capacity, % of reference
- 103.3 %
- 0.1 C · 25 °C · discharge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.1C | Discharge | % (vs.1/3C) | 103.30%
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: discharge table under the figure, column 0.1C (PDF page 10)- Capacity, % of reference
- 100 %
- 0.3 C · 25 °C · discharge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
- Same passage as capacity, % of reference · page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: discharge table under the figure, column 0.3C (PDF page 10)
- Capacity, % of reference
- 98.8 %
- 0.5 C · 25 °C · discharge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.5C | Discharge | % (vs.1/3C) | 98.80%
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: discharge table under the figure, column 0.5C (PDF page 10)- Capacity, % of reference
- 97.5 %
- 1 C · 25 °C · discharge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 1C | Discharge | % (vs.1/3C) | 97.50%
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: discharge table under the figure, column 1C (PDF page 10)- Capacity, % of reference
- 97.6 %
- 2 C · 25 °C · discharge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 2C | Discharge | % (vs.1/3C) | 97.60%
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: discharge table under the figure, column 2C (PDF page 10)- Capacity, % of reference
- 98.4 %
- 3 C · 25 °C · discharge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 3C | Discharge | % (vs.1/3C) | 98.40%
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: discharge table under the figure, column 3C (PDF page 10)- Capacity, % of reference
- 100.2 %
- 0.1 C · 25 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.1C | Charge (CC/CV) | % (vs.1/3C) | 100.20%
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 0.1C (PDF page 10)- Capacity, % of reference
- 103.7 %
- 0.1 C · 25 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.1C | Charge (CC) | % (vs.1/3C) | 103.70%
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 0.1C (PDF page 10)- Capacity, % of reference
- 100 %
- 0.2 C · 25 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.2C | Charge (CC/CV) | % (vs.1/3C) | 100.00%
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 0.2C (PDF page 10)- Capacity, % of reference
- 101.8 %
- 0.2 C · 25 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.2C | Charge (CC) | % (vs.1/3C) | 101.80%
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 0.2C (PDF page 10)- Capacity, % of reference
- 100 %
- 0.3 C · 25 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
- Same passage as capacity, % of reference · page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 0.3C (PDF page 10)
- Capacity, % of reference
- 100 %
- 0.3 C · 25 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
- Same passage as capacity, % of reference · page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 0.3C (PDF page 10)
- Capacity, % of reference
- 100 %
- 0.5 C · 25 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.5C | Charge (CC/CV) | % (vs.1/3C) | 100.00%
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 0.5C (PDF page 10)- Capacity, % of reference
- 98.3 %
- 0.5 C · 25 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.5C | Charge (CC) | % (vs.1/3C) | 98.30%
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 0.5C (PDF page 10)- Capacity, % of reference
- 100 %
- 1 C · 25 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 1C | Charge (CC/CV) | % (vs.1/3C) | 100.00%
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 1C (PDF page 10)- Capacity, % of reference
- 93.6 %
- 1 C · 25 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 1C | Charge (CC) | % (vs.1/3C) | 93.60%
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 1C (PDF page 10)- Capacity, % of reference
- 100.2 %
- 2 C · 25 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 2C | Charge (CC/CV) | % (vs.1/3C) | 100.20%
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 2C (PDF page 10)- Capacity, % of reference
- 86.6 %
- 2 C · 25 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 2C | Charge (CC) | % (vs.1/3C) | 86.60%
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 2C (PDF page 10)- Capacity, % of reference
- 100.4 %
- 3 C · 25 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
- Same passage as capacity, % of reference · page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 3C (PDF page 10)
- Capacity, % of reference
- 80.7 %
- 3 C · 25 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 3C | Charge (CC) | % (vs.1/3C) | 80.70%
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 3C (PDF page 10)- Capacity, % of reference
- 100.5 %
- 4 C · 25 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 4C | Charge (CC/CV) | % (vs.1/3C) | 100.50%
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 4C (PDF page 10)- Capacity, % of reference
- 74.9 %
- 4 C · 25 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 4C | Charge (CC) | % (vs.1/3C) | 74.90%
· page 10, Rated Capacity, 0.1C ~4C rates @ 25℃: charge table under the figure, column 4C (PDF page 10)- Capacity, % of reference
- 105.3 %
- 0.1 C · 5 °C · discharge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.1C | Discharge | % (vs.1/3C) | 105.30%
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: discharge table under the figure, column 0.1C (PDF page 11)- Capacity, % of reference
- 100 %
- 0.3 C · 5 °C · discharge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
- Same passage as capacity, % of reference · page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: discharge table under the figure, column 0.3C (PDF page 11)
- Capacity, % of reference
- 98.6 %
- 0.5 C · 5 °C · discharge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.5C | Discharge | % (vs.1/3C) | 98.60%
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: discharge table under the figure, column 0.5C (PDF page 11)- Capacity, % of reference
- 97.8 %
- 1 C · 5 °C · discharge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 1C | Discharge | % (vs.1/3C) | 97.80%
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: discharge table under the figure, column 1C (PDF page 11)- Capacity, % of reference
- 100 %
- 2 C · 5 °C · discharge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 2C | Discharge | % (vs.1/3C) | 100.00%
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: discharge table under the figure, column 2C (PDF page 11)- Capacity, % of reference
- 101.9 %
- 3 C · 5 °C · discharge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 3C | Discharge | % (vs.1/3C) | 101.90%
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: discharge table under the figure, column 3C (PDF page 11)- Capacity, % of reference
- 100.1 %
- 0.1 C · 5 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.1C | Charge (CC/CV) | % (vs.1/3C) | 100.10%
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 0.1C (PDF page 11)- Capacity, % of reference
- 105.8 %
- 0.1 C · 5 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.1C | Charge (CC) | % (vs.1/3C) | 105.80%
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 0.1C (PDF page 11)- Capacity, % of reference
- 100 %
- 0.2 C · 5 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
- Same passage as capacity, % of reference · page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 0.2C (PDF page 11)
- Capacity, % of reference
- 102.7 %
- 0.2 C · 5 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.2C | Charge (CC) | % (vs.1/3C) | 102.70%
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 0.2C (PDF page 11)- Capacity, % of reference
- 100 %
- 0.3 C · 5 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
- Same passage as capacity, % of reference · page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 0.3C (PDF page 11)
- Capacity, % of reference
- 100 %
- 0.3 C · 5 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
- Same passage as capacity, % of reference · page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 0.3C (PDF page 11)
- Capacity, % of reference
- 100 %
- 0.5 C · 5 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
- Same passage as capacity, % of reference · page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 0.5C (PDF page 11)
- Capacity, % of reference
- 97.1 %
- 0.5 C · 5 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.5C | Charge (CC) | % (vs.1/3C) | 97.10%
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 0.5C (PDF page 11)- Capacity, % of reference
- 100 %
- 1 C · 5 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
- Same passage as capacity, % of reference · page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 1C (PDF page 11)
- Capacity, % of reference
- 91.4 %
- 1 C · 5 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 1C | Charge (CC) | % (vs.1/3C) | 91.40%
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 1C (PDF page 11)- Capacity, % of reference
- 100.3 %
- 2 C · 5 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
- Same passage as capacity, % of reference · page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 2C (PDF page 11)
- Capacity, % of reference
- 84.7 %
- 2 C · 5 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 2C | Charge (CC) | % (vs.1/3C) | 84.70%
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 2C (PDF page 11)- Capacity, % of reference
- 100.6 %
- 3 C · 5 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 3C | Charge (CC/CV) | % (vs.1/3C) | 100.60%
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 3C (PDF page 11)- Capacity, % of reference
- 75.5 %
- 3 C · 5 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 3C | Charge (CC) | % (vs.1/3C) | 75.50%
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 3C (PDF page 11)- Capacity, % of reference
- 100.6 %
- 4 C · 5 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 4C | Charge (CC/CV) | % (vs.1/3C) | 100.60%
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 4C (PDF page 11)- Capacity, % of reference
- 61.4 %
- 4 C · 5 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 4C | Charge (CC) | % (vs.1/3C) | 61.40%
· page 11, Rated Capacity, 0.1C ~4C rates @ 5℃: charge table under the figure, column 4C (PDF page 11)- Capacity, % of reference
- 105.4 %
- 0.1 C · -10 °C · discharge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.1C | Discharge | % (vs.1/3C) | 105.40%
· page 12, Rated Capacity, 0.1C ~2C rates @ -10℃: discharge table under the figure, column 0.1C (PDF page 12)- Capacity, % of reference
- 100 %
- 0.3 C · -10 °C · discharge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
- Same passage as capacity, % of reference · page 12, Rated Capacity, 0.1C ~2C rates @ -10℃: discharge table under the figure, column 0.3C (PDF page 12)
- Capacity, % of reference
- 99.8 %
- 0.5 C · -10 °C · discharge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.5C | Discharge | % (vs.1/3C) | 99.80%
· page 12, Rated Capacity, 0.1C ~2C rates @ -10℃: discharge table under the figure, column 0.5C (PDF page 12)- Capacity, % of reference
- 102.2 %
- 1 C · -10 °C · discharge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 1C | Discharge | % (vs.1/3C) | 102.20%
· page 12, Rated Capacity, 0.1C ~2C rates @ -10℃: discharge table under the figure, column 1C (PDF page 12)- Capacity, % of reference
- 107.3 %
- 2 C · -10 °C · discharge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 2C | Discharge | % (vs.1/3C) | 107.30%
· page 12, Rated Capacity, 0.1C ~2C rates @ -10℃: discharge table under the figure, column 2C (PDF page 12)- Capacity, % of reference
- 101.7 %
- 0.1 C · -10 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.1C | Charge (CC/CV) | % (vs.1/3C) | 101.70%
· page 12, Rated Capacity, 0.1C ~2C rates @ -10℃: charge table under the figure, column 0.1C (PDF page 12)- Capacity, % of reference
- 110.5 %
- 0.1 C · -10 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.1C | Charge (CC) | % (vs.1/3C) | 110.50%
· page 12, Rated Capacity, 0.1C ~2C rates @ -10℃: charge table under the figure, column 0.1C (PDF page 12)- Capacity, % of reference
- 100 %
- 0.3 C · -10 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
- Same passage as capacity, % of reference · page 12, Rated Capacity, 0.1C ~2C rates @ -10℃: charge table under the figure, column 0.3C (PDF page 12)
- Capacity, % of reference
- 100 %
- 0.3 C · -10 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
- Same passage as capacity, % of reference · page 12, Rated Capacity, 0.1C ~2C rates @ -10℃: charge table under the figure, column 0.3C (PDF page 12)
- Capacity, % of reference
- 99.6 %
- 0.5 C · -10 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.5C | Charge (CC/CV) | % (vs.1/3C) | 99.60%
· page 12, Rated Capacity, 0.1C ~2C rates @ -10℃: charge table under the figure, column 0.5C (PDF page 12)- Capacity, % of reference
- 97.3 %
- 0.5 C · -10 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.5C | Charge (CC) | % (vs.1/3C) | 97.30%
· page 12, Rated Capacity, 0.1C ~2C rates @ -10℃: charge table under the figure, column 0.5C (PDF page 12)- Capacity, % of reference
- 96.5 %
- 0.1 C · -25 °C · discharge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.1C | Discharge | % (vs.1/3C) | 96.50%
· page 13, Rated Capacity, 0.025C ~1C rates @ -25℃: discharge table under the figure, column 0.1C (PDF page 13)- Capacity, % of reference
- 100 %
- 0.3 C · -25 °C · discharge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
- Same passage as capacity, % of reference · page 13, Rated Capacity, 0.025C ~1C rates @ -25℃: discharge table under the figure, column 0.3C (PDF page 13)
- Capacity, % of reference
- 100.4 %
- 0.5 C · -25 °C · discharge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 0.5C | Discharge | % (vs.1/3C) | 100.40%
· page 13, Rated Capacity, 0.025C ~1C rates @ -25℃: discharge table under the figure, column 0.5C (PDF page 13)- Capacity, % of reference
- 104.1 %
- 1 C · -25 °C · discharge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, temperature reference
C-rate 1C | Discharge | % (vs.1/3C) | 104.10%
· page 13, Rated Capacity, 0.025C ~1C rates @ -25℃: discharge table under the figure, column 1C (PDF page 13)- Capacity, % of reference
- 113.4 %
- 0.025 C · -25 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.025C | Charge (CC/CV) | % (vs.1/3C) | 113.40%
· page 13, Rated Capacity, 0.025C ~1C rates @ -25℃: charge table under the figure, column 0.025C (PDF page 13)- Capacity, % of reference
- 112.3 %
- 0.025 C · -25 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.025C | Charge (CC) | % (vs.1/3C) | 112.30%
· page 13, Rated Capacity, 0.025C ~1C rates @ -25℃: charge table under the figure, column 0.025C (PDF page 13)- Capacity, % of reference
- 113 %
- 0.05 C · -25 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.05C | Charge (CC/CV) | % (vs.1/3C) | 113.00%
· page 13, Rated Capacity, 0.025C ~1C rates @ -25℃: charge table under the figure, column 0.05C (PDF page 13)- Capacity, % of reference
- 106.5 %
- 0.05 C · -25 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.05C | Charge (CC) | % (vs.1/3C) | 106.50%
· page 13, Rated Capacity, 0.025C ~1C rates @ -25℃: charge table under the figure, column 0.05C (PDF page 13)- Capacity, % of reference
- 100 %
- 0.1 C · -25 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
- Same passage as capacity, % of reference · page 13, Rated Capacity, 0.025C ~1C rates @ -25℃: charge table under the figure, column 0.1C (PDF page 13)
- Capacity, % of reference
- 100 %
- 0.1 C · -25 °C · charge · typical value. Not stated: capacity the rate refers to, discharge cut-off voltage, charge voltage, temperature reference
C-rate 0.1C | Charge (CC) | % (vs.1/3C) | 100.00%
· page 13, Rated Capacity, 0.025C ~1C rates @ -25℃: charge table under the figure, column 0.1C (PDF page 13)
A journal article independent of the maker: Hassini, M., Redondo-Iglesias, E., Venet, P. (2023), Second-Life Batteries Modeling for Performance Tracking in a Mobile Charging Station, World Electric Vehicle Journal 14(4): 94 (2023-04-03): 8 values. Under CC BY 4.0: credit its authors when you reuse these values. Record file: review/revisions/samsung-sdi/94ah-hassini-2023-wevj.yaml.
Electrical
- Capacity
- 90.5 Ah
- 1 C · 0 °C chamber set-point · to 2.7 V · measured value
Performance comparison between a fresh cell (datasheet) and a second life cell (experiments).
· page 6, second-life cell, 0 °C: Table 3, 'Capacity (CC-CV, −1C)'- Capacity
- 92.4 Ah
- 1 C · 25 °C chamber set-point · to 2.7 V · measured value
- Same passage as capacity · page 6, second-life cell, 25 °C: Table 3, 'Capacity (CC-CV, −1C)'
- Capacity
- 93.3 Ah
- 1 C · 40 °C chamber set-point · to 2.7 V · measured value
- Same passage as capacity · page 6, second-life cell, 40 °C: Table 3, 'Capacity (CC-CV, −1C)'
Impedance
- DC internal resistance
- 2.3 mΩ
- 1 C · 0 °C chamber set-point · 50 % DoD · 5 s pulse · discharge · measured value. Not stated: pulse current, state of charge
- Same passage as capacity · page 6, second-life cell, 0 °C: Table 3, 'Resistance (5 s, DoD 50%, −1C)'
- DC internal resistance
- 1.3 mΩ
- 1 C · 25 °C chamber set-point · 50 % DoD · 5 s pulse · discharge · measured value. Not stated: pulse current, state of charge
- Same passage as capacity · page 6, second-life cell, 25 °C: Table 3, 'Resistance (5 s, DoD 50%, −1C)'
- DC internal resistance
- 1.6 mΩ
- 1 C · 40 °C chamber set-point · 50 % DoD · 5 s pulse · discharge · measured value. Not stated: pulse current, state of charge
- Same passage as capacity · page 6, second-life cell, 40 °C: Table 3, 'Resistance (5 s, DoD 50%, −1C)'
Lifetime
- State of health
- 97 %
- 1 C · 25 °C chamber set-point · measured value
- Same passage as capacity · page 6, second-life cell, 25 °C: Table 3, 'State of Health', capacity
- State of health
- 97 %
- 1 C · 40 °C chamber set-point · measured value
- Same passage as capacity · page 6, second-life cell, 40 °C: Table 3, 'State of Health', capacity
A journal article independent of the maker: Hassini, M., Redondo-Iglesias, E., Venet, P. (2024), Battery Passports for Second-Life Batteries: An Experimental Assessment of Suitability for Mobile Applications, Batteries 10(5): 153 (2024-04-30): 4 values. Under CC BY 4.0: credit its authors when you reuse these values. Record file: review/revisions/samsung-sdi/94ah-hassini-2024-batteries.yaml.
Electrical
- Capacity
- 91.8 Ah
- 1 C · 25 °C chamber set-point · to 2.7 V · mean value
Spread of performance measurements in a second-life battery module.
· page 13, 12 second-life cells, mean: Table 4, row 'Q (Ah)'- Energy
- 267.5 Wh
- 1 C · 25 °C chamber set-point · mean value
- Same passage as capacity · page 13, 12 second-life cells, mean: Table 4, row 'E (Wh)'
Impedance
- DC internal resistance
- 1.3 mΩ
- 1 C · 25 °C chamber set-point · 50 % SoC · 10 s pulse · discharge · mean value
- Same passage as capacity · page 13, 12 second-life cells, mean: Table 4, row 'R(t) (mΩ)'
Lifetime
- Energy efficiency
- 90.7 %
- 1 C · 25 °C chamber set-point · mean value
- Same passage as capacity · page 13, 12 second-life cells, mean: Table 4, row 'η (%)'
A preprint independent of the maker: Hassini, M., Mintsa-Eya, C., Redondo-Iglesias, E., Venet, P. (2025), Influence of Cell Position on the Capacity of Retired Batteries: Experimental and Statistical Studies, arXiv:2507.14020, v1 (2025-07-18): 2 values. Under CC BY 4.0: credit its authors when you reuse these values. Record file: review/revisions/samsung-sdi/94ah-hassini-2025-arxiv.yaml.
Electrical
- Capacity
- 90.3 Ah
- 1 C · 25 °C · to 2.7 V · mean value
µ: 90.3 Ah
· page 3, 36 retired (second-life) cells, mean: Fig. 3 and Table III
Lifetime
- State of health
- 95 %
- 1 C · 25 °C · mean value
On average, the cells had a 95% state of health capacity with a dispersion of 2.4%.
· page 1, 36 retired (second-life) cells, mean: Abstract
A dataset independent of the maker: Hassini, M., Redondo-Iglesias, E., Venet, P. (2026), Characterisation tests of three retired Samsung SDI 94Ah modules, version 1, Recherche Data Gouv, Université Gustave Eiffel, 1 (2026-06-19): 16 values. Under Licence Ouverte 2.0 (Etalab): credit Univ. Gustave Eiffel and the date of the data's last update (19 June 2026) when you reuse these values. Record file: review/revisions/samsung-sdi/94ah-hassini-2026-recherche-data-gouv.yaml.
Electrical
- Capacity
- 90.13 Ah
- 1 C · 25 °C chamber set-point · to 2.7 V · mean value
36 high-capacity (94Ah) NMC prismatic cells from three BMWi3 modules (12S1P) were tested at 25°C.
· 36 second-life (retired) cells, all three modules: mean 1C capacity, from the capacity test in 2_processed_data.zip- Capacity
- 92.11 Ah
- 1 C · 25 °C chamber set-point · to 2.7 V · mean value
1. Capacity measurement
· 12 second-life (retired) cells, module 1: mean 1C capacity, from the capacity test in 2_processed_data.zip- Capacity
- 88.66 Ah
- 1 C · 25 °C chamber set-point · to 2.7 V · mean value
- Same passage as capacity · 12 second-life (retired) cells, module 2: mean 1C capacity, from the capacity test in 2_processed_data.zip
- Capacity
- 89.63 Ah
- 1 C · 25 °C chamber set-point · to 2.7 V · mean value
- Same passage as capacity · 12 second-life (retired) cells, module 3: mean 1C capacity, from the capacity test in 2_processed_data.zip
- Capacity
- 90.91 Ah
- 0.05 C · 25 °C chamber set-point · to 2.7 V · mean value
3. Pseudo OCV measurement
· 35 second-life (retired) cells, all three modules: mean C/20 capacity, from the pseudo OCV test in 2_processed_data.zip- Capacity
- 92.36 Ah
- 0.05 C · 25 °C chamber set-point · to 2.7 V · mean value
- Same passage as capacity · 12 second-life (retired) cells, module 1: mean C/20 capacity, from the pseudo OCV test in 2_processed_data.zip
- Capacity
- 89.62 Ah
- 0.05 C · 25 °C chamber set-point · to 2.7 V · mean value
- Same passage as capacity · 12 second-life (retired) cells, module 2: mean C/20 capacity, from the pseudo OCV test in 2_processed_data.zip
- Capacity
- 90.74 Ah
- 0.05 C · 25 °C chamber set-point · to 2.7 V · mean value
- Same passage as capacity · 11 second-life (retired) cells, module 3: mean C/20 capacity, from the pseudo OCV test in 2_processed_data.zip
Impedance
- DC internal resistance
- 1.62 mΩ
- 1 C · 25 °C chamber set-point · 50 % SoC · 10 s pulse · discharge · mean value
2. Impedance measurement
· 34 second-life (retired) cells, all three modules: mean 10 s 1C discharge pulse resistance at the 50 % level, from the pulse test in 2_processed_data.zip- DC internal resistance
- 1.19 mΩ
- 1 C · 25 °C chamber set-point · 50 % SoC · 10 s pulse · discharge · mean value
- Same passage as dc internal resistance · 10 second-life (retired) cells, module 1: mean 10 s 1C discharge pulse resistance at the 50 % level, from the pulse test in 2_processed_data.zip
- DC internal resistance
- 2.42 mΩ
- 1 C · 25 °C chamber set-point · 50 % SoC · 10 s pulse · discharge · mean value
- Same passage as dc internal resistance · 12 second-life (retired) cells, module 2: mean 10 s 1C discharge pulse resistance at the 50 % level, from the pulse test in 2_processed_data.zip
- DC internal resistance
- 1.18 mΩ
- 1 C · 25 °C chamber set-point · 50 % SoC · 10 s pulse · discharge · mean value
- Same passage as dc internal resistance · 12 second-life (retired) cells, module 3: mean 10 s 1C discharge pulse resistance at the 50 % level, from the pulse test in 2_processed_data.zip
- DC internal resistance
- 1.67 mΩ
- 1 C · 25 °C chamber set-point · 50 % SoC · 10 s pulse · charge · mean value
- Same passage as dc internal resistance · 34 second-life (retired) cells, all three modules: mean 10 s 1C charge pulse resistance at the 50 % level, from the pulse test in 2_processed_data.zip
- DC internal resistance
- 1.2 mΩ
- 1 C · 25 °C chamber set-point · 50 % SoC · 10 s pulse · charge · mean value
- Same passage as dc internal resistance · 10 second-life (retired) cells, module 1: mean 10 s 1C charge pulse resistance at the 50 % level, from the pulse test in 2_processed_data.zip
- DC internal resistance
- 2.51 mΩ
- 1 C · 25 °C chamber set-point · 50 % SoC · 10 s pulse · charge · mean value
- Same passage as dc internal resistance · 12 second-life (retired) cells, module 2: mean 10 s 1C charge pulse resistance at the 50 % level, from the pulse test in 2_processed_data.zip
- DC internal resistance
- 1.23 mΩ
- 1 C · 25 °C chamber set-point · 50 % SoC · 10 s pulse · charge · mean value
- Same passage as dc internal resistance · 12 second-life (retired) cells, module 3: mean 10 s 1C charge pulse resistance at the 50 % level, from the pulse test in 2_processed_data.zip
Source and dates
One document behind every value. Each value above is read from it, and quoted where the record holds the passage.
- Kind
- datasheet
- Note
- Samsung SDI presentation dated 31 Dec 2015, hosted on a forum mirror. Read as extracted text on 2026-11-05; no sha256 recorded here (a copy downloaded from the same URL on 2026-11-19 is hashed in the figures revision, review/revisions/samsung-sdi/94ah-introduction-2015-12-31-figures.yaml); no document number or revision is printed. The document does not state the cell chemistry, so no chemistry designation is recorded. The specification summary is on PDF page 5 (the slide prints 'Page 6'). Printed in the summary but not recorded here: the resistances at room temperature and 50% SOC (0.75 mOhm for a 5 s discharge pulse, 0.99 mOhm for 30 s) and the charge 'Peak' of 270 A. The deck's graphs and curve tables, its operating current limit tables (PDF page 42) and its voltage limits (PDF page 45), including the 2.1 V discharge limit below -20 ℃ within 30 s, are filed in the figures revision. Record revised on 2026-11-19 by Lemonergy (review/audits/2026-11-19-samsung-94ah-record-revision.json): the summary's operating voltage range 2.7 ~ 4.15 V, first filed as absolute limits, is now filed as the charge and discharge cut-off voltages, as the library files other 'Operating voltage' ranges; page 45 calls 4.15 V and 2.7 V the operating limits and gives the safety limits as 4.25 V and 1.5 V. The summary's continuous currents and its discharge 'Peak' now say how they relate to the page-42 tables, and the locators give the PDF page. An earlier version of this note described the page-42 table as 'peak discharge 409 A for 150 s'; the 150 s is the averaging window of the continuous limit, not a duration of the 409 A peak.
- Source document date
- 2015-12-31 (day precision) (evidence)
- Source revision
- Not recorded
- Specification source retrieved
- 2026-11-05 (day precision) (evidence)
- Product lifecycle checked
- Not recorded
- Product release
- Not researched
- Date context
- Source retrieval and document revision do not establish product release or current availability.
- Record id
cell/samsung-sdi/94ah
How to cite
Samsung SDI. “Introduction of Samsung SDI's 94Ah cells”, datasheet, 2015-12-31. https://www.mikrocontroller.net/attachment/491363/SDI94Ah.pdf (retrieved 2026-11-05). Values as compiled in the Lemonergy battery library, record cell/samsung-sdi/94ah: https://lemonergy.com/data/batteries/samsung-sdi/94ah/
The values are CC BY 4.0; the document and the passages quoted from it belong to its publisher. All sources of the library
Suppliers of this product
No supplier has listed this product yet. Do you supply it? Write to [email protected].
Similar batteries
Compare it with these. Nearest in the library by kind, format, chemistry, capacity and specific energy.
- EVE Energy LF100LA102 Ah LFP prismatic cell · 3.2 V · 164 Wh/kgView the page
- EVE Energy LF9090 Ah LFP prismatic cell · 3.2 V · 144 Wh/kgView the page
- EVE Energy LF90K90 Ah LFP prismatic cell · 3.2 V · 144 Wh/kgView the page
- EVE Energy LF105105 Ah LFP prismatic cell · 3.2 V · 170 Wh/kgView the page
- GS Yuasa Lithium Power LSE110110 Ah LCO prismatic cell · 3.7 V · 163 Wh/kgView the page
- GS Yuasa Lithium Power LSE102102 Ah LCO prismatic cell · 3.7 V · 152 Wh/kgView the page