lemonergy/ data

GS Yuasa Lithium Power LSE102

102 Ah LCO prismatic cell.

Every value read from the datasheet, with the conditions it was stated at.

Compare in the finderSource documentRecord as JSON (API)Report a correction

Capacity
102Ah
Nominal voltage
3.7V
Energy
377Wh
Mass
2.77kg
Specific energy
152Wh/kg
Energy density
337Wh/L
Dimensions
216 × 130 × 50mm
Continuous discharge
150 A · 1.5C
Operating temperature1
−10 to 35°C
  1. 1Operating temperature: discharge; charge 10 to 35 °C.
  2. Not stated by the source: cycle life, internal resistance.

Specifications

Every value, with its conditions. 19 quantities stated by the datasheet, grouped as in the finder. Conditions are the rate, temperature and limits each value was stated at.

Current and power

Continuous discharge current
150 A
maximum value. Not stated: temperature
Max. Continuous Discharge Current (A) | 76.5 | 150 | 134 · page 1, Cell Specifications table, column LSE102 (second of LSE51, LSE102, LSE134)
Continuous charge current
50 A
maximum value. Not stated: temperature
Max. Continuous Charge Current (A) | 25.5 | 50 | 67 · page 1, Cell Specifications table, column LSE102 (second of LSE51, LSE102, LSE134)
Pulse discharge current
300 A
5 s pulse · maximum value. Not stated: temperature
Max. Pulse Discharge Current (A) (5 seconds) | 153 | 300 | 402 · page 1, Cell Specifications table, column LSE102 (second of LSE51, LSE102, LSE134)

Density

Specific energy
152 Wh/kg
Not stated: rate, temperature
Specific Energy at BOL (Wh/kg) | 139 | 152 | 155 · page 1, Cell Specifications table, column LSE102 (second of LSE51, LSE102, LSE134)
Energy density
337 Wh/L
Not stated: rate, temperature
Energy Density at BOL (Wh/L) | 289 | 337 | 349 · page 1, Cell Specifications table, column LSE102 (second of LSE51, LSE102, LSE134)

Electrical

Nominal voltage
3.7 V
nominal value
Nominal Voltage (V) | 3.7 | 3.7 | 3.7 · page 1, Cell Specifications table, column LSE102 (second of LSE51, LSE102, LSE134)
Capacity
102 Ah
rated value. Not stated: rate, temperature, discharge cut-off voltage
Capacity (Ah) | Nameplate | 51 | 102 | 134 · page 1, Cell Specifications table, column LSE102 (second of LSE51, LSE102, LSE134)
Capacity
114 Ah
initial value. Not stated: rate, temperature, discharge cut-off voltage
BOL | 57 | 114 | 148 · page 1, Cell Specifications table, column LSE102 (second of LSE51, LSE102, LSE134)
Charge cutoff voltage
4.1 V
standard value
End of Charge (V) | 4.1 | 4.1 | 4.1 · page 1, Cell Specifications table, column LSE102 (second of LSE51, LSE102, LSE134)
Discharge cutoff voltage
2.75 V
standard value
End of Discharge (V) | 2.75 | 2.75 | 2.75 · page 1, Cell Specifications table, column LSE102 (second of LSE51, LSE102, LSE134)
Energy
377 Wh
rated value. Not stated: rate, temperature
Energy (Wh) | Nameplate | 189 | 377 | 496 · page 1, Cell Specifications table, column LSE102 (second of LSE51, LSE102, LSE134)
Energy
422 Wh
initial value. Not stated: rate, temperature
BOL | 211 | 422 | 548 · page 1, Cell Specifications table, column LSE102 (second of LSE51, LSE102, LSE134)

Physical

Mass
2.77 kg
nominal value
Weight (kg) | 1.52 | 2.77 | 3.53 · page 1, Cell Specifications table, column LSE102 (second of LSE51, LSE102, LSE134)
Height
216 mm
nominal value
Height * | 131 | 216 | 271 · page 1, Cell Specifications table, column LSE102 (second of LSE51, LSE102, LSE134)
Width
130 mm
nominal value
Dimensions (mm) | Width | 130 | 130 | 130 · page 1, Cell Specifications table, column LSE102 (second of LSE51, LSE102, LSE134)
Thickness
50 mm
nominal value
Thickness | 50 | 50 | 50 · page 1, Cell Specifications table, column LSE102 (second of LSE51, LSE102, LSE134)
Volume
1.25 L
nominal value
Volume (L) | 0.73 | 1.25 | 1.57 · page 1, Cell Specifications table, column LSE102 (second of LSE51, LSE102, LSE134)

Thermal and safety

Operating temperature, min
10 °C
charge · minimum value. Not stated: temperature reference
Charge | 10 ~ 35 | 10 ~ 35 | 10 ~ 35 · page 1, Cell Specifications table, column LSE102 (second of LSE51, LSE102, LSE134)
Operating temperature, min
−10 °C
discharge · minimum value. Not stated: temperature reference
Discharge | -10 ~ 35 | -10 ~ 35 | -10 ~ 35 · page 1, Cell Specifications table, column LSE102 (second of LSE51, LSE102, LSE134)
Operating temperature, max
35 °C
charge · maximum value. Not stated: temperature reference
Same passage as operating temperature, min · page 1, Cell Specifications table, column LSE102 (second of LSE51, LSE102, LSE134)
Operating temperature, max
35 °C
discharge · maximum value. Not stated: temperature reference
Same passage as operating temperature, min · page 1, Cell Specifications table, column LSE102 (second of LSE51, LSE102, LSE134)
Storage temperature min
−10 °C
minimum value. Not stated: duration
Storage | -10 ~ 10 | -10 ~ 10 | -10 ~ 10 · page 1, Cell Specifications table, column LSE102 (second of LSE51, LSE102, LSE134)
Storage temperature max
10 °C
maximum value. Not stated: duration
Same passage as storage temperature min · page 1, Cell Specifications table, column LSE102 (second of LSE51, LSE102, LSE134)

Chemistry

What it is made of. Classified as Lithium-ion · LCO.

Classified as
Lithium-ion · LCO
Designation
LCO
Cathode
Lithium Cobalt Oxide

Chemistry | Lithium Cobalt Oxide

Source and dates

One document behind every value. Each value above is read from it, and quoted where the record holds the passage.

Document
GS Yuasa Lithium Power, Lithium Ion Cells For Satellites - Power Optimized (LSE Gen III: LSE51, LSE102, LSE134)
Kind
datasheet
SHA-256
f9b2e1f86aed1f03fa891e48c6e899f30f8bc0ffc150c6e6a5b52b4ccbb847ea
Note
Two-page GS Yuasa Lithium Power data sheet, served by the maker's own website (gsyuasa-lp.com, Spec Sheets & SDS page, file GS_Yuasa_LSE_GEN_III_Power.pdf). It prints no document number, revision or issue date (the PDF metadata carries a 2012 date, which is not printed). One table covers three cells; each record takes its own column (read from the rendered page: the columns follow the header order LSE51, LSE102, LSE134). Capacity and energy are printed as 'Nameplate' and 'BOL'; both are filed, with no rate, temperature or cut-off because the table states none. The three 'Max.' current rows are filed as printed (continuous charge, continuous discharge, and pulse discharge for 5 seconds), with the test temperature unstated. The 'End of Charge' and 'End of Discharge' voltages are filed as the charge and discharge cut-off voltages and keep their printed labels in extra. The chemistry row ('Lithium Cobalt Oxide') is one merged cell across all three columns of this table. Height is printed 'Height *' with the footnote '* Excluding terminals'. Not recorded: the 'Space Qualified' row, page 2 (cycling and model graphs; their conditions belong to the plotted test cells, not to the table). The form factor is the library's classification; the sheet prints 'Wound prismatic construction' and 'Anodized aluminum case and cover'.
Source document date
Not recorded (evidence)
Source revision
Not recorded
Specification source retrieved
2026-11-13 (day precision) (evidence)
Product lifecycle checked
Not recorded
Product release
Not researched
Date context
Source retrieval and document revision do not establish product release or current availability.
Record id
cell/gs-yuasa-lithium-power/lse102

How to cite

GS Yuasa Lithium Power. “GS Yuasa Lithium Power, Lithium Ion Cells For Satellites - Power Optimized (LSE Gen III: LSE51, LSE102, LSE134)”, datasheet. https://gsyuasa-lp.com/SpecSheets/GS_Yuasa_LSE_GEN_III_Power.pdf (retrieved 2026-11-13). Values as compiled in the Lemonergy battery library, record cell/gs-yuasa-lithium-power/lse102: https://lemonergy.com/data/batteries/gs-yuasa-lithium-power/lse102/

The values are CC BY 4.0; the document and the passages quoted from it belong to its publisher. All sources of the library

Suppliers of this product