Voltage window

The range between a cell’s lower and upper cutoff voltages, such as 2.5–4.2 V for an NMC/graphite cell. Staying inside it is what keeps the electrodes and electrolyte from degrading quickly.

Also called
operating voltage range
Unit
V

Example

Voltage under load

5 A through 20 mΩ gives 0.1 V ohmic drop.

Chosen OCV curve; no chemistry calibration, hysteresis or voltage cutoff.

Explore the graph

Discharge current creates an ohmic drop below open-circuit voltage.

Illustrative OCV and loaded voltage
Illustrative OCV and loaded voltageSOC (%) versus Voltage (V). Open circuit; Under load. Interpretation follows the graphs.1.802.42253.05503.67754.3100SOC (%)Voltage (V)
Open circuitUnder load (dashed)

5 A through 20 mΩ gives 0.1 V ohmic drop.

V_terminal = OCV − I_discharge R

Illustrative model. Chosen OCV curve; no chemistry calibration, hysteresis or voltage cutoff.

Use in Lemonergy

Separate nameplate ratings from test results.

This is a reference concept. No executable Lemonergy block has been verified for this term.

References & further reading

Further reading on this topic

These sources provide broader context; they are not presented as citations for every statement in this entry.

  1. The International System of Units (SI), 9th edition

    Bureau International des Poids et Mesures · 2026

    Topic background · Definitions of SI units and coherent derived units; 2026 revision.

  2. Battery Test Manual For Electric Vehicles, Revision 3

    Jon P. Christopherson · Idaho National Laboratory · 2015

    Topic background · Performance characterization, pulse resistance/power, life testing and reference performance tests; historical 2015 edition.