Battery knowledge · Modules, packs and battery management
Modbus
A simple industrial register-based protocol, over serial RS-485 or TCP, that stationary storage systems use between battery, inverter and site controller. It is old, open and universally supported, which is why it survives in grid equipment.
Example
Modules, packs and battery management: an example situation
Twelve 3.6 V, 5 Ah cells in 6s2p give 21.6 V, 10 Ah and 216 Wh nominally before other restrictions.
Read Modbus alongside CAN bus in this context. The serial network over which a BMS talks to the vehicle or inverter: a two-wire differential bus, defined in ISO 11898, carrying short prioritised messages at up to 1 Mbit/s, or faster with CAN FD. Every node hears every message, and a dominant bit wins arbitration without any collision.
Use in Lemonergy
Make series/parallel architecture explicit.
This is a reference concept. No executable Lemonergy block has been verified for this term.
References & further reading
Further reading on this topic
These sources provide broader context; they are not presented as citations for every statement in this entry.
- Extended Kalman filtering for battery management systems of LiPB-based HEV battery packs: Part 2. Modeling and identification
Gregory L. Plett · Journal of Power Sources · 2004
Topic background · Battery charge balance, open-circuit voltage, ohmic loss, polarization dynamics and model identification; parameters require cell-specific data.
- Getting Started with the BQ76925
Texas Instruments · 2019
Topic background · A concrete BMS analog front-end example: cell voltage, current, temperature measurement and MCU integration.