Lemonergy · Studio block
Heat flow sensor
Ideal inline sensor with zero temperature drop; positive flow a to b
- Implementation ID
thermal-flow-sensor- Reviewed
- 2026-10-27
Behavior
Conserving component solved simultaneously with the connected network. Ideal inline sensor with zero temperature drop; positive flow a to b
Interface
| Name | Direction | Unit | Meaning |
|---|---|---|---|
a | terminal | K; W | thermal conserving connection; absolute temperature with balanced heat flow. |
b | terminal | K; W | thermal conserving connection; absolute temperature with balanced heat flow. |
heatFlow | output | W | Recorded heat flow measurement from the conserving simulation. |
temperature | output | K | Recorded temperature measurement from the conserving simulation. |
branchHeatFlow | output | W | Recorded branchHeatFlow measurement from the conserving simulation. |
Parameters
No configurable parameters for this component.
Equations and rules
Ta = TbQ̇a→b is solved by the connected heat balance
Worked example
Heat flow sensor worked example
Editable first-party network. hot-boundary: differenceK=320; cold-boundary: differenceK=300. Checks below were verified in the native execution engine.
Open Studio example after release →| Output | Time (s) | Expected value | Unit | Absolute tolerance |
|---|---|---|---|---|
heatFlowtarget/heatFlow | 1 | 10 | W | 9.999999999999999e-06 |
temperaturetarget/temperature | 1 | 320 | K | 0.00031999999999999997 |
branchHeatFlowtarget/branchHeatFlow | 1 | 10 | W | 9.999999999999999e-06 |
Use in a workflow
Heat flow sensor worked example
Ideal inline sensor with zero temperature drop; positive flow a to b
- Heat flow sensor: Conserving component solved simultaneously with the connected network. Ideal inline sensor with zero temperature drop; positive flow a to b
- Use the block reference for settings and connections.
- Implementation tested locally; public release pending.
Connected concepts
Limits and interpretation
- Ideal inline sensor with zero temperature drop; positive flow a to b
- Demonstration parameters are not calibrated hardware data. Singular or incompatible ideal constraints and unsupported state ranges stop the run.
Scientific and mathematical references
These sources explain the scientific and mathematical background. The behavior, interface and limits above define the Lemonergy implementation; a citation does not imply every model option in the source is implemented.
- University Physics Volume 2, §1.6: Mechanisms of Heat Transfer
OpenStax, Rice University
Technical reference · Conduction, convection, radiation and thermal resistance.
- Enthalpy
NASA Glenn Research Center
Technical reference · Underlying physical law or reduced-model basis; Lemonergy implementation choices and limits are documented separately.
Implementation sources
This reference follows the public interface and locally verified numerical checks for an upcoming release.
Contract: Lemonergy Studio public contract · Verification record: verification-2026-10-27
docs/glossary/native-block-verification.json
This implementation and its workflow uses (JSON) · Knowledge graph (JSON-LD)