lemonergy/ data

GS Yuasa Lithium Power LSE51

51 Ah LCO prismatic cell.

Every value read from the datasheet, with the conditions it was stated at.

Compare in the finderSource documentRecord as JSON (API)Report a correction

Capacity
51Ah
Nominal voltage
3.7V
Energy
189Wh
Mass
1.52kg
Specific energy
139Wh/kg
Energy density
289Wh/L
Dimensions
131 × 130 × 50mm
Continuous discharge
76.5 A · 1.5C
Operating temperature1
−10 to 35°C
  1. 1Operating temperature: discharge; charge 10 to 35 °C.
  2. Not stated by the source: cycle life, internal resistance.

Curves

1 curve from the datasheet. A further source for this battery, the maker's datasheet: GS Yuasa Lithium Power, Lithium Ion Cells For Satellites - Power Optimized (LSE Gen III): the LSE51 cycle-test capacity points, plots 1 curve; they are drawn below with its name on each figure.

LSE51 C/2 Capacity
digitised from the datasheet
Lemonergy Data, https://lemonergy.com/data/, CC BY 4.0: credit Lemonergy when you reuse this figure020004000600080001000012000515253545556Cycle number, cyclesCapacity, AhCycle number 120 LSE51 C/2 Capacity: 55.80 AhCycle number 360 LSE51 C/2 Capacity: 54.90 AhCycle number 600 LSE51 C/2 Capacity: 54.90 AhCycle number 840 LSE51 C/2 Capacity: 54.60 AhCycle number 1080 LSE51 C/2 Capacity: 54.45 AhCycle number 1320 LSE51 C/2 Capacity: 54.00 AhCycle number 1560 LSE51 C/2 Capacity: 53.90 AhCycle number 1800 LSE51 C/2 Capacity: 53.80 AhCycle number 2040 LSE51 C/2 Capacity: 53.70 AhCycle number 2280 LSE51 C/2 Capacity: 53.60 AhCycle number 2520 LSE51 C/2 Capacity: 53.60 AhCycle number 2760 LSE51 C/2 Capacity: 53.60 AhCycle number 3000 LSE51 C/2 Capacity: 53.54 AhCycle number 3240 LSE51 C/2 Capacity: 53.33 AhCycle number 3480 LSE51 C/2 Capacity: 53.13 AhCycle number 3720 LSE51 C/2 Capacity: 52.92 AhCycle number 3960 LSE51 C/2 Capacity: 52.86 AhCycle number 4200 LSE51 C/2 Capacity: 52.82 AhCycle number 4440 LSE51 C/2 Capacity: 52.78 AhCycle number 4680 LSE51 C/2 Capacity: 52.73 AhCycle number 4920 LSE51 C/2 Capacity: 52.67 AhCycle number 5160 LSE51 C/2 Capacity: 52.54 AhCycle number 5400 LSE51 C/2 Capacity: 52.41 AhCycle number 5640 LSE51 C/2 Capacity: 52.30 AhCycle number 5880 LSE51 C/2 Capacity: 52.33 AhCycle number 6120 LSE51 C/2 Capacity: 52.46 AhCycle number 6360 LSE51 C/2 Capacity: 52.59 AhCycle number 6600 LSE51 C/2 Capacity: 52.70 AhCycle number 6840 LSE51 C/2 Capacity: 52.72 AhCycle number 7080 LSE51 C/2 Capacity: 52.74 AhCycle number 7320 LSE51 C/2 Capacity: 52.76 AhCycle number 7560 LSE51 C/2 Capacity: 52.78 AhCycle number 7800 LSE51 C/2 Capacity: 52.78 AhCycle number 8040 LSE51 C/2 Capacity: 52.61 AhCycle number 8280 LSE51 C/2 Capacity: 52.45 AhCycle number 8520 LSE51 C/2 Capacity: 52.19 AhCycle number 8760 LSE51 C/2 Capacity: 52.08 AhCycle number 9000 LSE51 C/2 Capacity: 52.05 AhCycle number 9240 LSE51 C/2 Capacity: 52.02 AhCycle number 9480 LSE51 C/2 Capacity: 51.95 AhCycle number 9720 LSE51 C/2 Capacity: 51.58 AhCycle number 9960 LSE51 C/2 Capacity: 51.52 AhCycle number 10200 LSE51 C/2 Capacity: 51.46 AhCycle number 10440 LSE51 C/2 Capacity: 51.40 AhCycle number 10680 LSE51 C/2 Capacity: 51.40 AhCycle number 10920 LSE51 C/2 Capacity: 51.40 AhCycle number 11160 LSE51 C/2 Capacity: 51.40 AhCycle number 11400 LSE51 C/2 Capacity: 51.40 Ah
LSE51 40% DoD Life Cycle Testing with Capacity Retention Model: discharge, 25.5 A, at 15 °C. From a further source for this battery, the maker's datasheet: GS Yuasa Lithium Power, Lithium Ion Cells For Satellites - Power Optimized (LSE Gen III): the LSE51 cycle-test capacity points. Not stated: capacity the rate refers to, lower voltage. Points were digitised from the figure image (recipe: review/digitisation/gs-yuasa-lse-gen3-power-lse51-life-cycle-capacity.json). Curves from this document are in review/revisions/gs-yuasa-lithium-power/lse51-gen-iii-power-data-sheet-figures.yaml.
Table: 1 line
LinePointsNotes
LSE51 C/2 Capacity24hidden 597–839 cycles, 1000–1322 cycles, 1483–1806 cycles, 1967–2289 cycles, 2450–2772 cycles, 2934–3739 cycles, 3900–4706 cycles, 4867–5592 cycles, 5834–6559 cycles, 6801–7526 cycles, 7768–8493 cycles, 8734–9460 cycles, 9621–10426 cycles, 10588–11393 cycles, spanned
Free, sent to your email

Specifications

Every value, with its conditions. 19 quantities stated by the datasheet, grouped as in the finder. Conditions are the rate, temperature and limits each value was stated at.

Current and power

Continuous discharge current
76.5 A
maximum value. Not stated: temperature
Max. Continuous Discharge Current (A) | 76.5 | 150 | 134 · page 1, Cell Specifications table, column LSE51 (first of LSE51, LSE102, LSE134)
Continuous charge current
25.5 A
maximum value. Not stated: temperature
Max. Continuous Charge Current (A) | 25.5 | 50 | 67 · page 1, Cell Specifications table, column LSE51 (first of LSE51, LSE102, LSE134)
Pulse discharge current
153 A
5 s pulse · maximum value. Not stated: temperature
Max. Pulse Discharge Current (A) (5 seconds) | 153 | 300 | 402 · page 1, Cell Specifications table, column LSE51 (first of LSE51, LSE102, LSE134)

Density

Specific energy
139 Wh/kg
Not stated: rate, temperature
Specific Energy at BOL (Wh/kg) | 139 | 152 | 155 · page 1, Cell Specifications table, column LSE51 (first of LSE51, LSE102, LSE134)
Energy density
289 Wh/L
Not stated: rate, temperature
Energy Density at BOL (Wh/L) | 289 | 337 | 349 · page 1, Cell Specifications table, column LSE51 (first of LSE51, LSE102, LSE134)

Electrical

Nominal voltage
3.7 V
nominal value
Nominal Voltage (V) | 3.7 | 3.7 | 3.7 · page 1, Cell Specifications table, column LSE51 (first of LSE51, LSE102, LSE134)
Capacity
51 Ah
rated value. Not stated: rate, temperature, discharge cut-off voltage
Capacity (Ah) | Nameplate | 51 | 102 | 134 · page 1, Cell Specifications table, column LSE51 (first of LSE51, LSE102, LSE134)
Capacity
57 Ah
initial value. Not stated: rate, temperature, discharge cut-off voltage
BOL | 57 | 114 | 148 · page 1, Cell Specifications table, column LSE51 (first of LSE51, LSE102, LSE134)
Charge cutoff voltage
4.1 V
standard value
End of Charge (V) | 4.1 | 4.1 | 4.1 · page 1, Cell Specifications table, column LSE51 (first of LSE51, LSE102, LSE134)
Discharge cutoff voltage
2.75 V
standard value
End of Discharge (V) | 2.75 | 2.75 | 2.75 · page 1, Cell Specifications table, column LSE51 (first of LSE51, LSE102, LSE134)
Energy
189 Wh
rated value. Not stated: rate, temperature
Energy (Wh) | Nameplate | 189 | 377 | 496 · page 1, Cell Specifications table, column LSE51 (first of LSE51, LSE102, LSE134)
Energy
211 Wh
initial value. Not stated: rate, temperature
BOL | 211 | 422 | 548 · page 1, Cell Specifications table, column LSE51 (first of LSE51, LSE102, LSE134)

Physical

Mass
1.52 kg
nominal value
Weight (kg) | 1.52 | 2.77 | 3.53 · page 1, Cell Specifications table, column LSE51 (first of LSE51, LSE102, LSE134)
Height
131 mm
nominal value
Height * | 131 | 216 | 271 · page 1, Cell Specifications table, column LSE51 (first of LSE51, LSE102, LSE134)
Width
130 mm
nominal value
Dimensions (mm) | Width | 130 | 130 | 130 · page 1, Cell Specifications table, column LSE51 (first of LSE51, LSE102, LSE134)
Thickness
50 mm
nominal value
Thickness | 50 | 50 | 50 · page 1, Cell Specifications table, column LSE51 (first of LSE51, LSE102, LSE134)
Volume
0.73 L
nominal value
Volume (L) | 0.73 | 1.25 | 1.57 · page 1, Cell Specifications table, column LSE51 (first of LSE51, LSE102, LSE134)

Thermal and safety

Operating temperature, min
10 °C
charge · minimum value. Not stated: temperature reference
Charge | 10 ~ 35 | 10 ~ 35 | 10 ~ 35 · page 1, Cell Specifications table, column LSE51 (first of LSE51, LSE102, LSE134)
Operating temperature, min
−10 °C
discharge · minimum value. Not stated: temperature reference
Discharge | -10 ~ 35 | -10 ~ 35 | -10 ~ 35 · page 1, Cell Specifications table, column LSE51 (first of LSE51, LSE102, LSE134)
Operating temperature, max
35 °C
charge · maximum value. Not stated: temperature reference
Same passage as operating temperature, min · page 1, Cell Specifications table, column LSE51 (first of LSE51, LSE102, LSE134)
Operating temperature, max
35 °C
discharge · maximum value. Not stated: temperature reference
Same passage as operating temperature, min · page 1, Cell Specifications table, column LSE51 (first of LSE51, LSE102, LSE134)
Storage temperature min
−10 °C
minimum value. Not stated: duration
Storage | -10 ~ 10 | -10 ~ 10 | -10 ~ 10 · page 1, Cell Specifications table, column LSE51 (first of LSE51, LSE102, LSE134)
Storage temperature max
10 °C
maximum value. Not stated: duration
Same passage as storage temperature min · page 1, Cell Specifications table, column LSE51 (first of LSE51, LSE102, LSE134)

Chemistry

What it is made of. Classified as Lithium-ion · LCO.

Classified as
Lithium-ion · LCO
Designation
LCO
Cathode
Lithium Cobalt Oxide

Chemistry | Lithium Cobalt Oxide

Source and dates

One document behind every value. Each value above is read from it, and quoted where the record holds the passage.

Document
GS Yuasa Lithium Power, Lithium Ion Cells For Satellites - Power Optimized (LSE Gen III: LSE51, LSE102, LSE134)
Kind
datasheet
SHA-256
f9b2e1f86aed1f03fa891e48c6e899f30f8bc0ffc150c6e6a5b52b4ccbb847ea
Note
Two-page GS Yuasa Lithium Power data sheet, served by the maker's own website (gsyuasa-lp.com, Spec Sheets & SDS page, file GS_Yuasa_LSE_GEN_III_Power.pdf). It prints no document number, revision or issue date (the PDF metadata carries a 2012 date, which is not printed). One table covers three cells; each record takes its own column (read from the rendered page: the columns follow the header order LSE51, LSE102, LSE134). Capacity and energy are printed as 'Nameplate' and 'BOL'; both are filed, with no rate, temperature or cut-off because the table states none. The three 'Max.' current rows are filed as printed (continuous charge, continuous discharge, and pulse discharge for 5 seconds), with the test temperature unstated. The 'End of Charge' and 'End of Discharge' voltages are filed as the charge and discharge cut-off voltages and keep their printed labels in extra. The chemistry row ('Lithium Cobalt Oxide') is one merged cell across all three columns of this table. Height is printed 'Height *' with the footnote '* Excluding terminals'. Not recorded: the 'Space Qualified' row, page 2 (cycling and model graphs; their conditions belong to the plotted test cells, not to the table). The form factor is the library's classification; the sheet prints 'Wound prismatic construction' and 'Anodized aluminum case and cover'.
Source document date
Not recorded (evidence)
Source revision
Not recorded
Specification source retrieved
2026-11-13 (day precision) (evidence)
Product lifecycle checked
Not recorded
Product release
Not researched
Date context
Source retrieval and document revision do not establish product release or current availability.
Record id
cell/gs-yuasa-lithium-power/lse51

How to cite

GS Yuasa Lithium Power. “GS Yuasa Lithium Power, Lithium Ion Cells For Satellites - Power Optimized (LSE Gen III: LSE51, LSE102, LSE134)”, datasheet. https://gsyuasa-lp.com/SpecSheets/GS_Yuasa_LSE_GEN_III_Power.pdf (retrieved 2026-11-13). Values as compiled in the Lemonergy battery library, record cell/gs-yuasa-lithium-power/lse51: https://lemonergy.com/data/batteries/gs-yuasa-lithium-power/lse51/

The values are CC BY 4.0; the document and the passages quoted from it belong to its publisher. All sources of the library

Suppliers of this product

No supplier has listed this product yet. Do you supply it? Write to [email protected].