lemonergy/ data

GS Yuasa Lithium Power LFC40

40 Ah LCO prismatic cell.

Every value read from the datasheet, with the conditions it was stated at.

Compare in the finderSource documentRecord as JSON (API)Report a correction

Capacity
40Ah
Nominal voltage
3.7V
Energy1
148Wh
Mass
1.6kg
Specific energy
102Wh/kg
Energy density
244Wh/L
Dimensions
165 × 137 × 31mm
Internal resistance
≤ 1.1mΩ
Operating temperature2
0 to 65°C
  1. 1Energy: calculated by Lemonergy from stated values: capacity × voltage.
  2. 2Operating temperature: discharge; charge 10 to 30 °C.
  3. Not stated by the source: continuous discharge, cycle life.

Curves

4 curves from the datasheet. A further source for this battery, the maker's datasheet: GS Yuasa, Lithium ion cell for Aerospace applications LFC 40 (specification sheet): the page-2 figures that can be read from the scan, plots 4 curves; they are drawn below with its name on each figure.

Voltage
digitised from the datasheet
Lemonergy Data, https://lemonergy.com/data/, CC BY 4.0: credit Lemonergy when you reuse this figure0123456783.23.43.63.84.04.2Time, hVoltage, VTime 0.1 h Voltage: 3.442 VTime 0.2 h Voltage: 3.609 VTime 0.4 h Voltage: 3.699 VTime 0.6 h Voltage: 3.721 VTime 0.7 h Voltage: 3.730 VTime 0.9 h Voltage: 3.748 VTime 1.0 h Voltage: 3.766 VTime 1.2 h Voltage: 3.775 VTime 1.4 h Voltage: 3.795 VTime 1.5 h Voltage: 3.802 VTime 1.7 h Voltage: 3.811 VTime 1.8 h Voltage: 3.811 VTime 2.0 h Voltage: 3.811 VTime 2.2 h Voltage: 3.811 VTime 2.3 h Voltage: 3.825 VTime 2.5 h Voltage: 3.826 VTime 2.6 h Voltage: 3.827 VTime 2.8 h Voltage: 3.828 VTime 3.0 h Voltage: 3.838 VTime 3.1 h Voltage: 3.847 VTime 3.3 h Voltage: 3.856 VTime 3.4 h Voltage: 3.865 VTime 3.6 h Voltage: 3.879 VTime 3.8 h Voltage: 3.889 VTime 3.9 h Voltage: 3.901 VTime 4.1 h Voltage: 3.919 VTime 4.2 h Voltage: 3.928 VTime 4.4 h Voltage: 3.940 VTime 4.6 h Voltage: 3.950 VTime 4.7 h Voltage: 3.966 VTime 4.9 h Voltage: 3.980 VTime 5.0 h Voltage: 3.991 VTime 5.2 h Voltage: 4.000 VTime 5.4 h Voltage: 4.020 VTime 5.5 h Voltage: 4.050 VTime 5.7 h Voltage: 4.098 VTime 5.8 h Voltage: 4.099 VTime 6.0 h Voltage: 4.099 VTime 6.2 h Voltage: 4.099 VTime 6.3 h Voltage: 4.099 VTime 6.5 h Voltage: 4.099 VTime 6.6 h Voltage: 4.099 VTime 6.8 h Voltage: 4.099 VTime 7.0 h Voltage: 4.099 VTime 7.1 h Voltage: 4.099 VTime 7.3 h Voltage: 4.099 VTime 7.4 h Voltage: 4.099 VTime 7.6 h Voltage: 4.099 VTime 7.8 h Voltage: 4.099 VTime 7.9 h Voltage: 4.099 V
Charge Characteristics of LFC40 at BOL (voltage): charge, 8 A, at 25 °C. From a further source for this battery, the maker's datasheet: GS Yuasa, Lithium ion cell for Aerospace applications LFC 40 (specification sheet): the page-2 figures that can be read from the scan. Not stated: capacity the rate refers to, where the temperature was measured, rest before the test. Points were digitised from the figure image (recipe: review/digitisation/gs-yuasa-lfc40-charge-voltage.json). Curves from this document are in review/revisions/gs-yuasa-lithium-power/lfc40-specification-sheet-figures.yaml.
Table: 1 line
LinePointsNotes
Voltage90hidden 0.1–0.16 h, spanned
Free, sent to your email
Current
digitised from the datasheet
Lemonergy Data, https://lemonergy.com/data/, CC BY 4.0: credit Lemonergy when you reuse this figure0123456780246810Time, hCurrent, ATime 0.2 h Current: 8.04 ATime 0.4 h Current: 8.04 ATime 0.6 h Current: 8.04 ATime 0.7 h Current: 8.04 ATime 0.9 h Current: 8.04 ATime 1.0 h Current: 8.04 ATime 1.2 h Current: 8.04 ATime 1.4 h Current: 8.04 ATime 1.5 h Current: 8.04 ATime 1.7 h Current: 8.04 ATime 1.8 h Current: 8.04 ATime 2.0 h Current: 8.04 ATime 2.2 h Current: 8.04 ATime 2.3 h Current: 8.04 ATime 2.5 h Current: 8.04 ATime 2.6 h Current: 8.04 ATime 2.8 h Current: 8.04 ATime 3.0 h Current: 8.04 ATime 3.1 h Current: 8.04 ATime 3.3 h Current: 8.04 ATime 3.4 h Current: 8.04 ATime 3.6 h Current: 8.04 ATime 3.8 h Current: 8.04 ATime 3.9 h Current: 8.04 ATime 4.1 h Current: 8.04 ATime 4.2 h Current: 8.04 ATime 4.4 h Current: 8.04 ATime 4.6 h Current: 8.04 ATime 4.7 h Current: 8.04 ATime 4.9 h Current: 8.04 ATime 5.0 h Current: 8.04 ATime 5.2 h Current: 8.04 ATime 5.4 h Current: 8.04 ATime 5.5 h Current: 8.04 ATime 5.7 h Current: 7.81 ATime 5.8 h Current: 2.23 ATime 6.0 h Current: 1.64 ATime 6.2 h Current: 1.46 ATime 6.3 h Current: 1.28 ATime 6.5 h Current: 1.10 ATime 6.6 h Current: 0.93 ATime 6.8 h Current: 0.74 ATime 7.0 h Current: 0.56 ATime 7.1 h Current: 0.38 ATime 7.3 h Current: 0.38 ATime 7.4 h Current: 0.29 ATime 7.6 h Current: 0.24 A
Charge Characteristics of LFC40 at BOL (current): charge, 8 A, at 25 °C. From a further source for this battery, the maker's datasheet: GS Yuasa, Lithium ion cell for Aerospace applications LFC 40 (specification sheet): the page-2 figures that can be read from the scan. Not stated: capacity the rate refers to, where the temperature was measured, rest before the test. Points were digitised from the figure image (recipe: review/digitisation/gs-yuasa-lfc40-charge-current.json). Curves from this document are in review/revisions/gs-yuasa-lithium-power/lfc40-specification-sheet-figures.yaml.
Table: 1 line
LinePointsNotes
Current50
Free, sent to your email
0°C
digitised from the datasheet
Lemonergy Data, https://lemonergy.com/data/, CC BY 4.0: credit Lemonergy when you reuse this figure0510152025303540453.53.63.73.83.94.0Capacity, AhVoltage, VCapacity 0.5 Ah 0°C: 3.982 VCapacity 1.3 Ah 0°C: 3.923 VCapacity 2.3 Ah 0°C: 3.891 VCapacity 3.2 Ah 0°C: 3.869 VCapacity 4.0 Ah 0°C: 3.847 VCapacity 5.0 Ah 0°C: 3.826 VCapacity 5.9 Ah 0°C: 3.823 VCapacity 6.8 Ah 0°C: 3.814 VCapacity 7.7 Ah 0°C: 3.802 VCapacity 8.6 Ah 0°C: 3.799 VCapacity 9.4 Ah 0°C: 3.783 VCapacity 10.3 Ah 0°C: 3.775 VCapacity 11.3 Ah 0°C: 3.761 VCapacity 12.2 Ah 0°C: 3.761 VCapacity 13.0 Ah 0°C: 3.750 VCapacity 13.9 Ah 0°C: 3.739 VCapacity 14.9 Ah 0°C: 3.729 VCapacity 15.7 Ah 0°C: 3.729 VCapacity 16.6 Ah 0°C: 3.718 VCapacity 17.6 Ah 0°C: 3.713 VCapacity 18.4 Ah 0°C: 3.707 VCapacity 19.4 Ah 0°C: 3.696 VCapacity 20.3 Ah 0°C: 3.696 VCapacity 21.1 Ah 0°C: 3.685 VCapacity 22.1 Ah 0°C: 3.685 VCapacity 22.9 Ah 0°C: 3.674 VCapacity 23.9 Ah 0°C: 3.674 VCapacity 24.8 Ah 0°C: 3.674 VCapacity 25.6 Ah 0°C: 3.664 VCapacity 26.5 Ah 0°C: 3.664 VCapacity 27.4 Ah 0°C: 3.661 VCapacity 28.4 Ah 0°C: 3.652 VCapacity 29.3 Ah 0°C: 3.647 VCapacity 30.2 Ah 0°C: 3.637 VCapacity 31.0 Ah 0°C: 3.637 VCapacity 31.9 Ah 0°C: 3.626 VCapacity 32.9 Ah 0°C: 3.618 VCapacity 33.8 Ah 0°C: 3.610 VCapacity 34.6 Ah 0°C: 3.599 VCapacity 35.6 Ah 0°C: 3.588 VCapacity 36.5 Ah 0°C: 3.577 VCapacity 37.4 Ah 0°C: 3.566 VCapacity 38.3 Ah 0°C: 3.549 VCapacity 39.1 Ah 0°C: 3.534 VCapacity 40.0 Ah 0°C: 3.512 V
Discharge Characteristics of LFC40 at various temperature: discharge, 20 A, at 0 °C, 4.1 V to 3.5 V. From a further source for this battery, the maker's datasheet: GS Yuasa, Lithium ion cell for Aerospace applications LFC 40 (specification sheet): the page-2 figures that can be read from the scan. Not stated: capacity the rate refers to, where the temperature was measured, rest before the test. Points were digitised from the figure image (recipe: review/digitisation/gs-yuasa-lfc40-discharge-temperature.json). Curves from this document are in review/revisions/gs-yuasa-lithium-power/lfc40-specification-sheet-figures.yaml.
Table: 1 line
LinePointsCapacity at cut-off, AhNotes
0°C11540.270hidden 31.28–31.64 Ah, spanned
Free, sent to your email
Discharge capacity
digitised from the datasheet
Lemonergy Data, https://lemonergy.com/data/, CC BY 4.0: credit Lemonergy when you reuse this figure02468101244.845.045.245.445.645.846.0Cycle number, cyclesCapacity, AhCycle number 1.1 Discharge capacity: 45.806 AhCycle number 1.3 Discharge capacity: 45.702 AhCycle number 1.6 Discharge capacity: 45.599 AhCycle number 1.8 Discharge capacity: 45.496 AhCycle number 2.0 Discharge capacity: 45.410 AhCycle number 2.3 Discharge capacity: 45.410 AhCycle number 2.5 Discharge capacity: 45.410 AhCycle number 2.8 Discharge capacity: 45.410 AhCycle number 3.0 Discharge capacity: 45.410 AhCycle number 3.2 Discharge capacity: 45.357 AhCycle number 3.5 Discharge capacity: 45.304 AhCycle number 3.7 Discharge capacity: 45.252 AhCycle number 4.0 Discharge capacity: 45.199 AhCycle number 4.2 Discharge capacity: 45.190 AhCycle number 4.4 Discharge capacity: 45.190 AhCycle number 4.7 Discharge capacity: 45.190 AhCycle number 4.9 Discharge capacity: 45.190 AhCycle number 5.2 Discharge capacity: 45.190 AhCycle number 5.4 Discharge capacity: 45.190 AhCycle number 5.6 Discharge capacity: 45.190 AhCycle number 5.9 Discharge capacity: 45.190 AhCycle number 6.1 Discharge capacity: 45.174 AhCycle number 6.4 Discharge capacity: 45.143 AhCycle number 6.6 Discharge capacity: 45.112 AhCycle number 6.8 Discharge capacity: 45.081 AhCycle number 7.1 Discharge capacity: 44.980 AhCycle number 7.3 Discharge capacity: 44.980 AhCycle number 7.6 Discharge capacity: 44.980 AhCycle number 7.8 Discharge capacity: 44.980 AhCycle number 8.0 Discharge capacity: 44.985 AhCycle number 8.3 Discharge capacity: 45.016 AhCycle number 8.5 Discharge capacity: 45.048 AhCycle number 8.8 Discharge capacity: 45.079 AhCycle number 9.0 Discharge capacity: 45.110 AhCycle number 9.2 Discharge capacity: 45.190 AhCycle number 9.5 Discharge capacity: 45.190 AhCycle number 9.7 Discharge capacity: 45.190 AhCycle number 10.0 Discharge capacity: 45.190 AhCycle number 10.2 Discharge capacity: 45.190 AhCycle number 10.4 Discharge capacity: 45.190 AhCycle number 10.7 Discharge capacity: 45.190 AhCycle number 10.9 Discharge capacity: 45.190 AhCycle number 11.2 Discharge capacity: 45.171 AhCycle number 11.4 Discharge capacity: 45.142 AhCycle number 11.6 Discharge capacity: 45.113 AhCycle number 11.9 Discharge capacity: 45.084 Ah
Changes in Discharge Capacity of LFC40 during Cycle Testing: discharge. From a further source for this battery, the maker's datasheet: GS Yuasa, Lithium ion cell for Aerospace applications LFC 40 (specification sheet): the page-2 figures that can be read from the scan. Not stated: temperature, rate, rate unit, lower voltage, depth of discharge. Points were digitised from the figure image (recipe: review/digitisation/gs-yuasa-lfc40-cycle.json). Curves from this document are in review/revisions/gs-yuasa-lithium-power/lfc40-specification-sheet-figures.yaml.
Table: 1 line
LinePointsNotes
Discharge capacity15hidden 1–2 cycles, 2–3 cycles, 3–4 cycles, 4–5 cycles, 5–6 cycles, 6–7 cycles, 7–8 cycles, 8–9 cycles, 9–10 cycles, 10–11 cycles, 11–12 cycles, spanned
Free, sent to your email

Specifications

Every value, with its conditions. 13 quantities stated by the datasheet, grouped as in the finder. Conditions are the rate, temperature and limits each value was stated at.

Density

Specific energy
102 Wh/kg
Not stated: rate, temperature
Specific Energy (Wh/kg) | 102 · page 1, Cell specification
Energy density
244 Wh/L
Not stated: rate, temperature
Energy Density (Wh/l) | 244 · page 1, Cell specification

Electrical

Nominal voltage
3.7 V
nominal value
Nominal voltage (V) | 3.7 · page 1, Cell specification
Capacity
40 Ah
rated value. Not stated: rate, temperature, discharge cut-off voltage
Capacity (Ah) | Rated | 40 · page 1, Cell specification
Capacity
44 Ah
nominal value. Not stated: rate, temperature, discharge cut-off voltage
Capacity (Ah) | Nominal | 44 · page 1, Cell specification

Impedance

AC internal resistance
≤ 1.1 mΩ
maximum value. Not stated: frequency, state of charge, temperature
Maximum AC impedance at BOL | 1.1mΩ · page 1, Cell specification

Physical

Mass
1.6 kg
nominal value
Weight (Kg) | 1.6 · page 1, Cell specification
Height
165 mm
nominal value
Dimensions(mm) | Height | 165 · page 1, Cell specification
Width
137 mm
nominal value
Dimensions(mm) | Width | 137 · page 1, Cell specification
Thickness
31 mm
nominal value
Dimensions(mm) | Thickness | 31 · page 1, Cell specification

Thermal and safety

Operating temperature, min
10 °C
charge · minimum value. Not stated: temperature reference
Recommended temperature range | Charge | 10℃~30℃ · page 1, Cell specification
Operating temperature, min
0 °C
discharge · minimum value. Not stated: temperature reference
Recommended temperature range | Discharge | 0℃~65℃ · page 1, Cell specification
Operating temperature, max
30 °C
charge · maximum value. Not stated: temperature reference
Same passage as operating temperature, min · page 1, Cell specification
Operating temperature, max
65 °C
discharge · maximum value. Not stated: temperature reference
Same passage as operating temperature, min · page 1, Cell specification
Storage temperature min
−5 °C
minimum value. Not stated: duration
Recommended temperature range | Storage | -5℃~4℃ · page 1, Cell specification
Storage temperature max
4 °C
maximum value. Not stated: duration
Same passage as storage temperature min · page 1, Cell specification

Chemistry

What it is made of. Classified as Lithium-ion · LCO.

Classified as
Lithium-ion · LCO
Designation
LCO
Cathode
Lithium Cobalt Oxide

Lithium Cobalt Oxide cathode material

Source and dates

One document behind every value. Each value above is read from it, and quoted where the record holds the passage.

Document
GS Yuasa, Lithium ion cell for Aerospace applications LFC 40 (specification sheet)
Kind
datasheet
SHA-256
06d5bde78a6fe27550b78b2455b3030dc693eddd46994f8e45f64a92f51e447e
Note
Two-page GS Yuasa sheet 'Lithium ion cell for Aerospace applications LFC 40', served by the maker's own website (gsyuasa-lp.com, Spec Sheets & SDS page, file LFC40_Spec.pdf; page 2 footer 'LFC 40'). The pages are scans with no text layer; every value was read from the rendered page image (read from image). No document number, revision or issue date is printed (the PDF metadata carries a 2012 date, which is not printed). The table prints 'Capacity (Ah) Rated 40' and 'Nominal 44' without conditions; both are filed with unstated conditions. The temperature rows sit under the label 'Recommended temperature range' (Charge 10℃~30℃, Discharge 0℃~65℃, Storage -5℃~4℃); they are filed as operating and storage temperatures with that label kept in extra. Not recorded: 'Maximum charge rate(CA) 0.5' and 'Maximum discharge rate(CA) 1.0 (pulse 3.0,1.0sec)' (printed in 'CA' with no capacity reference and no unit in the library's vocabulary), the curves on page 2 and their test conditions, and the cell construction drawing. Chemistry: page 2 prints 'Lithium Cobalt Oxide cathode material'. The form factor is the library's classification; the sheet prints 'Elliptic cylindrical construction' and 'Stainless steel case' (the maker's product page says 'wound prismatic').
Source document date
Not recorded (evidence)
Source revision
Not recorded
Specification source retrieved
2026-11-13 (day precision) (evidence)
Product lifecycle checked
Not recorded
Product release
Not researched
Date context
Source retrieval and document revision do not establish product release or current availability.
Record id
cell/gs-yuasa-lithium-power/lfc40

How to cite

GS Yuasa Lithium Power. “GS Yuasa, Lithium ion cell for Aerospace applications LFC 40 (specification sheet)”, datasheet. https://gsyuasa-lp.com/SpecSheets/LFC40_Spec.pdf (retrieved 2026-11-13). Values as compiled in the Lemonergy battery library, record cell/gs-yuasa-lithium-power/lfc40: https://lemonergy.com/data/batteries/gs-yuasa-lithium-power/lfc40/

The values are CC BY 4.0; the document and the passages quoted from it belong to its publisher. All sources of the library

Suppliers of this product

No supplier has listed this product yet. Do you supply it? Write to [email protected].