Can we cool a battery’s terminals
without risking an electrical fault?

00:00:04.570 --> 00:00:06.525
Look inside the real prototype,

00:00:06.675 --> 00:00:09.240
then see what Lemonergy checks
before we build.

00:00:10.050 --> 00:00:14.200
Lift the cover to see the pouch cells
between the front and rear cooling plates.

00:00:17.455 --> 00:00:19.445
A jumper hose links the plates.

00:00:19.715 --> 00:00:23.325
In the close-up, the busbars transfer
heat into the coolant tube.

00:00:23.665 --> 00:00:26.230
The amber strip
is the voltage-sense cable.

00:00:28.005 --> 00:00:31.455
The insulation keeps the busbar
and tube electrically separate.

00:00:31.845 --> 00:00:36.365
Hand-bent busbars and thicker tubes
sometimes squeezed that gap too far.

00:00:36.725 --> 00:00:40.185
Control the spacing
and test isolation after molding.

00:00:40.798 --> 00:00:44.278
The cut section tells us
what to check inside the plate.

00:00:44.278 --> 00:00:47.508
At pack level, let’s start with
a separate storage example

00:00:47.508 --> 00:00:49.238
in Lemonergy Pack Designer.

00:00:49.598 --> 00:00:52.438
Import the design
with cooling underneath the cells.

00:00:52.695 --> 00:00:55.725
Save it as our baseline.
Now we have a reference.

00:00:55.975 --> 00:00:59.615
When we add cooling near the tabs,
we can see exactly what changed.

00:00:59.862 --> 00:01:03.602
Import the combined case
and compare it with the saved baseline.

00:01:03.942 --> 00:01:05.992
The bottom cold plate stays.

00:01:06.322 --> 00:01:08.932
The change is in
the cell interconnect carrier,

00:01:08.932 --> 00:01:11.192
where we propose a second coolant route.

00:01:11.465 --> 00:01:13.605
Follow the new route above the cells.

00:01:13.905 --> 00:01:15.855
The layout tells us where it goes.

00:01:15.855 --> 00:01:18.935
To find out if the connections
can carry the load,

00:01:18.935 --> 00:01:20.415
open the engineering audit.

00:01:20.695 --> 00:01:22.375
Pause on the joint warning.

00:01:22.715 --> 00:01:25.675
At the chosen load,
the current through each cell joint

00:01:25.675 --> 00:01:28.235
exceeds the allowance
used for this library part.

00:01:28.235 --> 00:01:30.995
Can we reduce the current
through each joint?

00:01:31.318 --> 00:01:33.168
Think about the path the current takes.

00:01:33.468 --> 00:01:35.668
With one string,
the same pack current

00:01:35.668 --> 00:01:38.088
passes through every cell joint
in that string.

00:01:38.372 --> 00:01:41.232
Now put two cells in parallel
in each series group.

00:01:41.232 --> 00:01:45.602
If the two cells share evenly,
each carries about half the pack current.

00:01:45.882 --> 00:01:46.832
Will that be enough?

00:01:47.132 --> 00:01:50.822
Lemonergy shows that the larger layout
still fits the envelope.

00:01:51.142 --> 00:01:54.282
We gained a second path
by using twice as many cells.

00:01:54.600 --> 00:01:56.090
Now look at the audit again.

00:01:56.360 --> 00:01:59.300
The current per joint fell,
and the check still fails.

00:01:59.600 --> 00:02:02.780
Our next design change
is a joint rated for this duty.

00:02:02.780 --> 00:02:04.560
Then we can run the check again.

00:02:04.872 --> 00:02:07.712
The joint warning tells us
what to change in the pack.

00:02:07.992 --> 00:02:11.082
There’s a separate question
about the coolant path.

00:02:11.082 --> 00:02:12.772
How much faster can it remove heat?

00:02:12.772 --> 00:02:15.872
Let’s return to the pouch module
we opened earlier.

00:02:16.163 --> 00:02:19.423
In Lemonergy Simulation Studio,
both cases start warm

00:02:19.423 --> 00:02:21.603
and lose heat to the same room.

00:02:21.993 --> 00:02:25.633
The active case also has a path
from the tabs to the coolant.

00:02:25.903 --> 00:02:27.093
Open that path.

00:02:27.353 --> 00:02:30.543
Here the model uses the difference
between module temperature

00:02:30.543 --> 00:02:33.373
and coolant temperature
to calculate heat flow.

00:02:33.653 --> 00:02:36.093
Heat must travel
along the thin nickel tab

00:02:36.093 --> 00:02:39.283
and across its clamped contact
with the busbar.

00:02:39.283 --> 00:02:40.353
Both resist heat flow.

00:02:40.603 --> 00:02:46.343
For the whole pouch module, Fraunhofer
reported 0.91 W/K for the tab path.

00:02:46.733 --> 00:02:49.553
The simulated seam path was 2.33 W/K.

00:02:49.853 --> 00:02:53.393
That supports testing tab cooling
alongside the main cooler.

00:02:53.733 --> 00:02:56.993
The gain for our proposed pack
still has to be demonstrated.

00:02:57.288 --> 00:03:01.338
Back in Lemonergy, run both cases
from the same starting temperature.

00:03:01.728 --> 00:03:05.128
Here we compare air cooling alone
with air plus tab cooling.

00:03:05.423 --> 00:03:07.533
Watch the blue curve fall faster.

00:03:07.783 --> 00:03:10.303
The extra path carries heat
out of the module.

00:03:10.583 --> 00:03:13.823
Each curve represents the module
as a single temperature.

00:03:14.203 --> 00:03:18.013
To see what happens at a hot spot,
we need sensors on hardware.

00:03:18.308 --> 00:03:20.568
That’s where
the charging experiment comes in.

00:03:20.908 --> 00:03:25.008
Fraunhofer charged the same prototype
with tab cooling off and on.

00:03:25.308 --> 00:03:27.828
We’ll compare the highest reading
on the center cell.

00:03:28.142 --> 00:03:32.212
With tab cooling on,
that peak was 16.2 °C lower.

00:03:32.212 --> 00:03:34.852
That’s the benefit measured
on this prototype.

00:03:34.852 --> 00:03:37.802
What does it take
to keep the coolant moving?

00:03:38.090 --> 00:03:41.560
Multiply the coolant flow
by the pressure drop across the plates.

00:03:41.560 --> 00:03:47.050
At the published test point,
that gives 1.7 W of hydraulic power

00:03:47.050 --> 00:03:48.610
through that section of the loop.

00:03:48.933 --> 00:03:51.903
For the electrical estimate, include
the rest of the loop

00:03:51.903 --> 00:03:54.613
and account for pump efficiency.

00:03:54.613 --> 00:03:58.483
In our illustrative example,
the pump draws 16.7 W.

00:03:58.803 --> 00:04:01.173
Cooling equipment uses power separately.

00:04:01.497 --> 00:04:03.567
So where does that leave us?

00:04:03.567 --> 00:04:07.877
The experiment shows why cooling
near the tabs is worth investigating.

00:04:07.877 --> 00:04:10.367
For our pack example,
choose a suitable joint,

00:04:10.367 --> 00:04:14.357
rerun the checks in Lemonergy,
and measure temperature, flow,

00:04:14.357 --> 00:04:16.887
and electrical isolation on the prototype.

00:04:17.173 --> 00:04:18.743
Then price the whole system.

00:04:19.053 --> 00:04:24.483
Include the interconnect, plumbing, pump,
assembly, testing, and operating energy.

00:04:24.863 --> 00:04:27.713
Compare it with
the original bottom-cooled design.

00:04:28.043 --> 00:04:32.243
Now you have the evidence to decide
whether the added cooling earns its place.