{
  "node": {
    "id": "term:target-soc-charging",
    "type": "Term",
    "label": "Target state-of-charge charging",
    "properties": {
      "id": "target-soc-charging",
      "name": "Target state-of-charge charging",
      "section": "topic-charging",
      "definition": "A target state of charge ends an ordinary charge session when the estimated charge fraction reaches the requested goal. It is a session policy layered over a compatible electrical charging profile.",
      "related": [
        "state-of-charge",
        "cc-cv-charging",
        "scheduled-charging",
        "charging-strategies"
      ],
      "example": {
        "title": "Worked example",
        "text": "Compare two sessions beginning at the same state of charge and selecting different session targets. The earlier stop reduces the requested charge, while voltage and temperature supervision remain separate."
      },
      "url": "https://lemonergy.com/learn/glossary/target-soc-charging/",
      "mentions": []
    }
  },
  "edges": [
    {
      "id": "edge:belongsTo/term:target-soc-charging/topic:topic-charging",
      "source": "term:target-soc-charging",
      "target": "topic:topic-charging",
      "type": "belongsTo",
      "properties": {
        "sourceFile": "terms.json"
      }
    },
    {
      "id": "edge:relatedTo/term:target-soc-charging/term:state-of-charge",
      "source": "term:target-soc-charging",
      "target": "term:state-of-charge",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:target-soc-charging/term:cc-cv-charging",
      "source": "term:target-soc-charging",
      "target": "term:cc-cv-charging",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:target-soc-charging/term:scheduled-charging",
      "source": "term:target-soc-charging",
      "target": "term:scheduled-charging",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:target-soc-charging/term:charging-strategies",
      "source": "term:target-soc-charging",
      "target": "term:charging-strategies",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:illustratedBy/term:target-soc-charging/visual:target-soc-profile",
      "source": "term:target-soc-charging",
      "target": "visual:target-soc-profile",
      "type": "illustratedBy",
      "properties": {
        "sourceFile": "visual-pages.json"
      }
    },
    {
      "id": "edge:cites/term:target-soc-charging/reference:tomaszewska-charging",
      "source": "term:target-soc-charging",
      "target": "reference:tomaszewska-charging",
      "type": "cites",
      "properties": {
        "sourceFile": "wiki-references.json",
        "scope": "direct technical reference"
      }
    },
    {
      "id": "edge:cites/term:target-soc-charging/reference:ti-li-charge",
      "source": "term:target-soc-charging",
      "target": "reference:ti-li-charge",
      "type": "cites",
      "properties": {
        "sourceFile": "wiki-references.json",
        "scope": "direct technical reference"
      }
    }
  ],
  "neighbors": [
    {
      "id": "topic:topic-charging",
      "type": "Topic",
      "label": "Charging and discharging",
      "properties": {
        "id": "topic-charging",
        "name": "Charging and discharging",
        "lede": "How current goes in and comes out, and the limits that stop it.",
        "context": "Separate regulation from availability.",
        "example": "The same CC–CV law can operate overnight or during a short depot stop.",
        "lesson_url": "https://lemonergy.com/learn/fundamentals/capacity-and-c-rate/",
        "lesson_label": "Open charging quantities"
      }
    },
    {
      "id": "term:state-of-charge",
      "type": "Term",
      "label": "State of charge",
      "properties": {
        "id": "state-of-charge",
        "name": "State of charge",
        "abbr": "SOC",
        "section": "topic-state",
        "definition": "How full a cell is, as a fraction of its available capacity. State of charge, like temperature, affects how fast a stored cell ages.",
        "unit": "%",
        "related": [
          "depth-of-discharge",
          "ocv-soc-curve",
          "coulomb-counting",
          "state-of-health",
          "bms"
        ],
        "lesson": "fundamentals/battery-aging/#storage-soc",
        "example": {
          "title": "Interpret a charge inventory",
          "text": "If available capacity is 5 Ah and 3 Ah remains by the chosen estimator, SOC is 60%. A different estimate of available capacity changes this percentage, so compare SOC values only with the capacity convention recorded."
        },
        "url": "https://lemonergy.com/learn/glossary/state-of-charge/",
        "mentions": [
          "usable-capacity"
        ]
      }
    },
    {
      "id": "term:cc-cv-charging",
      "type": "Term",
      "label": "CC-CV charging",
      "properties": {
        "id": "cc-cv-charging",
        "name": "CC-CV charging",
        "aka": [
          "constant current constant voltage"
        ],
        "section": "topic-charging",
        "definition": "The standard lithium-ion charge protocol: constant current until the cell reaches its upper cutoff voltage, then that voltage held constant while the current tapers. The charge ends when the current falls to a set fraction, often C/20.",
        "related": [
          "constant-current",
          "constant-voltage",
          "cutoff-voltage",
          "taper-current",
          "fast-charging",
          "cp-cv"
        ],
        "lesson": "fundamentals/capacity-and-c-rate/#real-cells",
        "example": {
          "title": "Follow a two-stage charge",
          "text": "For an illustrative 5 Ah cell, a 2.5 A current request is 0.5C. During CC the voltage rises. At the selected upper voltage, CV regulation holds voltage while current tapers. Completion requires the taper current to fall below the selected cutoff for the configured dwell."
        },
        "notes": [
          "Choose voltage, current and temperature limits from the actual cell specification. These example values do not define a charging recipe."
        ],
        "url": "https://lemonergy.com/learn/glossary/cc-cv-charging/",
        "mentions": []
      }
    },
    {
      "id": "term:scheduled-charging",
      "type": "Term",
      "label": "Scheduled and managed charging",
      "properties": {
        "id": "scheduled-charging",
        "name": "Scheduled and managed charging",
        "section": "topic-charging",
        "definition": "Scheduled charging chooses when charging begins or pauses, while managed charging may also set a power budget across several vehicles or storage units. The battery still enforces its local current and voltage limits.",
        "related": [
          "smart-charging",
          "depot-charging",
          "opportunity-charging",
          "charge-acceptance",
          "charging-strategies"
        ],
        "example": {
          "title": "Worked example",
          "text": "Two vehicles share a fictional site budget. Delay part of the demand to a later window and compare the peak site power, keeping vehicle limits separate from the site allocation."
        },
        "url": "https://lemonergy.com/learn/glossary/scheduled-charging/",
        "mentions": []
      }
    },
    {
      "id": "term:charging-strategies",
      "type": "Term",
      "label": "Battery charging strategies",
      "properties": {
        "id": "charging-strategies",
        "name": "Battery charging strategies",
        "section": "topic-charging",
        "definition": "Battery charging strategies define how a charger commands current, voltage or power and how it decides to change stages or stop. Chemistry, temperature, battery state and infrastructure also determine which strategies are applicable.",
        "related": [
          "cc-cv-charging",
          "mscc",
          "adaptive-charging",
          "lead-acid-bulk-absorption-float",
          "battery-test-equipment",
          "testing"
        ],
        "example": {
          "title": "Worked example",
          "text": "Compare a current-limited session, a power-limited session and a stepped current schedule at the same starting state of charge. Look for phase transitions and record the achieved charge separately from the peak current."
        },
        "guide": [
          {
            "title": "Basic electrical profiles",
            "terms": [
              "constant-current",
              "constant-voltage",
              "cc-cv-charging",
              "constant-power-charging",
              "cp-cv",
              "mscc",
              "mscc-cv",
              "ramped-current-charging",
              "taper-charging"
            ]
          },
          {
            "title": "Pulse and feedback profiles",
            "terms": [
              "pulse-charging",
              "reverse-pulse-charging",
              "adaptive-charging",
              "model-predictive-charging",
              "non-linear-voltammetry-charging"
            ]
          },
          {
            "title": "Temperature and charging speed",
            "terms": [
              "temperature-conditioned-charging",
              "preconditioning",
              "slow-charging",
              "fast-charging",
              "xfc",
              "dc-fast-charging",
              "charge-acceptance"
            ]
          },
          {
            "title": "Start, stop and maintenance",
            "terms": [
              "precharge-recharge",
              "target-soc-charging",
              "boost-charging",
              "trickle-charge",
              "float-charging",
              "lead-acid-bulk-absorption-float",
              "equalization-charge",
              "nickel-peak-termination",
              "iu-charging-characteristics",
              "negative-delta-v",
              "dt-dt-termination",
              "charge-termination",
              "refresh-charge",
              "reconditioning"
            ]
          },
          {
            "title": "Vehicle and site strategies",
            "terms": [
              "smart-charging",
              "scheduled-charging",
              "depot-charging",
              "opportunity-charging",
              "split-pack-charging",
              "regenerative-braking"
            ]
          }
        ],
        "url": "https://lemonergy.com/learn/glossary/charging-strategies/",
        "mentions": [
          "charger"
        ]
      }
    },
    {
      "id": "visual:target-soc-profile",
      "type": "Visual",
      "label": "End the charge session at the requested SOC",
      "properties": {
        "title": "End the charge session at the requested SOC",
        "summary": "Compare two target settings with the same illustrative starting state and pre-stop slope.",
        "readout": "At a target of 75%, the illustrative trace levels off after 66.18% of the time axis.",
        "formula": "Charging stops when the estimated SOC reaches the session target.",
        "note": "Original normalized teaching traces. They omit cell calibration and do not specify charger settings or predict charge time, aging or safety.",
        "software": {
          "status": "reference",
          "label": "Reference concept",
          "body": "The article links any separately verified Lemonergy workflow. These curves are independent teaching examples.",
          "href": "../glossary/charging-strategies/"
        },
        "html": "<figure class=\"visual-figure\"><figcaption>Estimated SOC during the session</figcaption><svg class=\"visual-chart\" viewBox=\"0 0 360 330\" role=\"img\" aria-labelledby=\"static-target-soc-profile-0-title static-target-soc-profile-0-desc\"><title id=\"static-target-soc-profile-0-title\">Estimated SOC during the session</title><desc id=\"static-target-soc-profile-0-desc\">Relative elapsed time versus State of charge (%). Selected target; 90% comparison target. Interpretation follows the graphs.</desc><path d=\"M74,238h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"242\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">0</text><text x=\"74\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0</text><path d=\"M74,188.5h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"192.5\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">25</text><text x=\"141\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0.25</text><path d=\"M74,139h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"143\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">50</text><text x=\"208\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0.5</text><path d=\"M74,89.5h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"93.5\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">75</text><text x=\"275\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0.75</text><path d=\"M74,40h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"44\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">100</text><text x=\"342\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">1</text><path d=\"M74,40v198h268\" fill=\"none\" stroke=\"currentColor\" opacity=\".3\"/><polyline fill=\"none\" stroke=\"#2459a8\" stroke-width=\"2.8\" points=\"74.00,178.60 251.35,89.50 342.00,89.50\"/><polyline fill=\"none\" stroke=\"#6953a8\" stroke-width=\"2.8\" stroke-dasharray=\"7 4\" points=\"74.00,178.60 310.47,59.80 342.00,59.80\"/><text transform=\"translate(208 303)\" text-anchor=\"middle\" font-size=\"14\" fill=\"currentColor\"><tspan x=\"0\" dy=\"0\">Relative elapsed time</tspan></text><text transform=\"translate(20 139) rotate(-90)\" text-anchor=\"middle\" font-size=\"14\" fill=\"currentColor\"><tspan x=\"0\" dy=\"0\">State of charge (%)</tspan></text></svg><div class=\"visual-legend\"><span><i style=\"background:#2459a8\"></i>Selected target</span><span><i style=\"background:#6953a8\"></i>90% comparison target (dashed)</span></div></figure>"
      }
    },
    {
      "id": "reference:tomaszewska-charging",
      "type": "Reference",
      "label": "Lithium-ion battery fast charging: A review",
      "properties": {
        "title": "Lithium-ion battery fast charging: A review",
        "publisher": "eTransportation",
        "url": "https://doi.org/10.1016/j.etran.2019.100011",
        "type": "Review article",
        "scope": "CC-CV and alternative charging protocols, transport limitations, degradation and thermal implications; results depend on cell and test conditions. Software behavior is documented separately in Lemonergy block references.",
        "year": 2019,
        "authors": [
          "Anna Tomaszewska et al."
        ],
        "accessed": "2026-10-27"
      }
    },
    {
      "id": "reference:ti-li-charge",
      "type": "Reference",
      "label": "BQ25895 single-cell charging controller technical documentation",
      "properties": {
        "title": "BQ25895 single-cell charging controller technical documentation",
        "publisher": "Texas Instruments",
        "url": "https://www.ti.com/product/BQ25895",
        "type": "Manufacturer technical documentation",
        "scope": "Example of precharge, CC–CV regulation, termination, recharge and temperature supervision in a lithium-ion charger.",
        "accessed": "2026-11-18"
      }
    }
  ]
}
