  "node": {
    "id": "term:round-trip-efficiency-test",
    "type": "Term",
    "label": "Battery round-trip efficiency test",
    "properties": {
      "id": "round-trip-efficiency-test",
      "name": "Battery round-trip efficiency test",
      "section": "topic-testing",
      "definition": "A battery round-trip efficiency test compares energy returned during discharge with energy supplied during charge over a declared duty cycle. The measurement boundary determines whether conversion losses and auxiliaries are included.",
      "related": [
        "bidirectional-dc-supply",
        "battery-data-acquisition",
        "battery-coolant-conditioner",
        "testing"
      ],
      "example": {
        "title": "What the report shows",
        "text": "The test record connects the specimen and conditions to the observation. Report watt-hours at each boundary and the resulting efficiency, along with SOC window, temperature and auxiliary load treatment."
      },
      "procedure": {
        "equipment": [
          "bidirectional-dc-supply",
          "battery-data-acquisition",
          "battery-coolant-conditioner"
        ],
        "steps": [
          "Define the measurement boundary and whether auxiliary loads are inside it.",
          "Record incoming and outgoing energy over the approved duty cycle with equivalent boundary states.",
          "Divide returned energy by input energy and repeat if the method calls for it."
        ],
        "record": "Report watt-hours at each boundary and the resulting efficiency, along with SOC window, temperature and auxiliary load treatment."
      },
      "url": "https://lemonergy.com/learn/glossary/round-trip-efficiency-test/",
      "mentions": [
        "energy-efficiency"
      ]
    }
  },
  "edges": [
    {
      "id": "edge:belongsTo/term:round-trip-efficiency-test/topic:topic-testing",
      "source": "term:round-trip-efficiency-test",
      "target": "topic:topic-testing",
      "type": "belongsTo",
      "properties": {
        "sourceFile": "terms.json"
      }
    },
    {
      "id": "edge:relatedTo/term:round-trip-efficiency-test/term:bidirectional-dc-supply",
      "source": "term:round-trip-efficiency-test",
      "target": "term:bidirectional-dc-supply",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:round-trip-efficiency-test/term:battery-data-acquisition",
      "source": "term:round-trip-efficiency-test",
      "target": "term:battery-data-acquisition",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:round-trip-efficiency-test/term:battery-coolant-conditioner",
      "source": "term:round-trip-efficiency-test",
      "target": "term:battery-coolant-conditioner",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:round-trip-efficiency-test/term:testing",
      "source": "term:round-trip-efficiency-test",
      "target": "term:testing",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:usesTestEquipment/term:round-trip-efficiency-test/term:bidirectional-dc-supply",
      "source": "term:round-trip-efficiency-test",
      "target": "term:bidirectional-dc-supply",
      "type": "usesTestEquipment",
      "properties": {
        "sourceFile": "wiki-editorial.json"
      }
    },
    {
      "id": "edge:usesTestEquipment/term:round-trip-efficiency-test/term:battery-data-acquisition",
      "source": "term:round-trip-efficiency-test",
      "target": "term:battery-data-acquisition",
      "type": "usesTestEquipment",
      "properties": {
        "sourceFile": "wiki-editorial.json"
      }
    },
    {
      "id": "edge:usesTestEquipment/term:round-trip-efficiency-test/term:battery-coolant-conditioner",
      "source": "term:round-trip-efficiency-test",
      "target": "term:battery-coolant-conditioner",
      "type": "usesTestEquipment",
      "properties": {
        "sourceFile": "wiki-editorial.json"
      }
    },
    {
      "id": "edge:mentions/round-trip-efficiency-test/energy-efficiency",
      "source": "term:round-trip-efficiency-test",
      "target": "term:energy-efficiency",
      "type": "mentions",
      "properties": {
        "sourceFile": "terms.json",
        "method": "build_glossary.mention_index + mentions",
        "field": "definition",
        "meaning": "Text mention; not a causal claim"
      }
    },
    {
      "id": "edge:illustratedBy/term:round-trip-efficiency-test/visual:efficiency-test-energy",
      "source": "term:round-trip-efficiency-test",
      "target": "visual:efficiency-test-energy",
      "type": "illustratedBy",
      "properties": {
        "sourceFile": "visual-pages.json"
      }
    },
    {
      "id": "edge:cites/term:round-trip-efficiency-test/reference:sandia-performance",
      "source": "term:round-trip-efficiency-test",
      "target": "reference:sandia-performance",
      "type": "cites",
      "properties": {
        "sourceFile": "wiki-references.json",
        "scope": "direct technical reference"
      }
    }
  ],
  "neighbors": [
    {
      "id": "topic:topic-testing",
      "type": "Topic",
      "label": "Testing methods",
      "properties": {
        "id": "topic-testing",
        "name": "Testing methods",
        "lede": "The measurements and test procedures that characterise a cell or pack, from capacity and pulse tests to abuse and environmental tests.",
        "context": "Record specimen, state, instrument, temperature and timing.",
        "example": "Resistance immediately after a current step can differ from a ten-second value because slower polarization contributes.",
        "lesson_url": "https://lemonergy.com/learn/fundamentals/capacity-and-c-rate/",
        "lesson_label": "Open capacity measurements"
      }
    },
    {
      "id": "term:bidirectional-dc-supply",
      "type": "Term",
      "label": "Bidirectional DC power supply",
      "properties": {
        "id": "bidirectional-dc-supply",
        "name": "Bidirectional DC power supply",
        "section": "topic-testing-equipment",
        "definition": "A bidirectional DC supply sources current to charge a specimen and sinks current during discharge. A regenerative model can return absorbed energy to its approved power system.",
        "related": [
          "cycler",
          "electronic-load",
          "hppc",
          "battery-test-equipment"
        ],
        "example": {
          "title": "Worked example",
          "text": "In a single pack drive-cycle trace, check that the commanded sign changes between charge and discharge, and that the instrument records the measured current at each transition."
        },
        "url": "https://lemonergy.com/learn/glossary/bidirectional-dc-supply/",
        "mentions": []
      }
    },
    {
      "id": "term:battery-data-acquisition",
      "type": "Term",
      "label": "Battery data acquisition system",
      "properties": {
        "id": "battery-data-acquisition",
        "name": "Battery data acquisition system",
        "section": "topic-testing-equipment",
        "definition": "A data acquisition system records and synchronizes channels such as voltage, temperature, current, pressure and displacement. Isolation, bandwidth and time alignment matter when different instruments observe the same event.",
        "related": [
          "thermocouples-rtds",
          "voltage-sense",
          "kelvin-sensing",
          "pulse-test",
          "battery-test-equipment"
        ],
        "example": {
          "title": "Worked example",
          "text": "During a fictional pulse, the voltage jumps before a slow temperature sensor changes. Record trigger time and each channel's sample rate to distinguish timing offsets from real thermal delay."
        },
        "url": "https://lemonergy.com/learn/glossary/battery-data-acquisition/",
        "mentions": []
      }
    },
    {
      "id": "term:battery-coolant-conditioner",
      "type": "Term",
      "label": "Battery coolant conditioning unit",
      "properties": {
        "id": "battery-coolant-conditioner",
        "name": "Battery coolant conditioning unit",
        "section": "topic-testing-equipment",
        "definition": "A coolant conditioning unit controls the inlet fluid conditions for a liquid-cooled module or pack. Flow and inlet and outlet temperatures document the imposed thermal boundary during performance testing.",
        "related": [
          "thermal-characterisation",
          "charge-acceptance",
          "battery-data-acquisition",
          "battery-test-equipment"
        ],
        "example": {
          "title": "Worked example",
          "text": "When two current profiles are compared, matching coolant inlet temperature alone is insufficient. The report also records flow rate and outlet temperature so heat removal can be interpreted."
        },
        "url": "https://lemonergy.com/learn/glossary/battery-coolant-conditioner/",
        "mentions": []
      }
    },
    {
      "id": "term:testing",
      "type": "Term",
      "label": "Battery testing procedures",
      "properties": {
        "id": "testing",
        "name": "Battery testing procedures",
        "section": "topic-testing",
        "definition": "Battery testing procedures describe how to characterize performance, durability, environmental behavior and safety at cell, module or pack level. A test plan defines the specimen, conditions, equipment, measurements and the applicable evaluation method.",
        "related": [
          "capacity-test",
          "cycler",
          "reference-performance-test",
          "abuse-testing",
          "datasheet",
          "charging-strategies"
        ],
        "aka": [
          "Cell testing"
        ],
        "testChooser": [
          {
            "goal": "Measure performance",
            "term": "capacity-test",
            "title": "Capacity test",
            "description": "Measure how much charge and energy the battery delivers under defined conditions.",
            "details": {
              "Equipment": "Cycler, temperature chamber, and cell fixture",
              "Procedure": "Condition the cell, then discharge at the specified current",
              "Record": "Ah, Wh, temperature, and cutoff voltage"
            },
            "action": "Open the capacity test"
          },
          {
            "goal": "Understand aging",
            "term": "cycle-life-test",
            "title": "Cycle-life test",
            "description": "Track how repeated cycling changes capacity and resistance.",
            "details": {
              "Equipment": "Cycler, temperature chamber, and data logger",
              "Procedure": "Cycle the battery and repeat reference performance tests",
              "Record": "Capacity, resistance, and charge throughput"
            },
            "action": "Open the cycle-life test"
          },
          {
            "goal": "Investigate a failure",
            "term": "post-mortem",
            "title": "Post-mortem analysis",
            "description": "Connect observations from a failed battery to the affected component and its test history.",
            "details": {
              "Equipment": "Specialist lab with appropriate containment",
              "Procedure": "Trace each sample to its location in the battery",
              "Record": "Test history, sample location, and preparation"
            },
            "action": "Open the post-mortem guide"
          },
          {
            "goal": "Plan qualification",
            "term": "transport-regulations",
            "title": "Start with the applicable standard",
            "description": "Match the test program to the product and its intended use. For transport, check which UN 38.3 tests apply.",
            "details": {
              "Define": "Specimen and intended use",
              "Confirm": "Applicable method and edition",
              "Record": "Test results and report reference"
            },
            "action": "Open the UN 38.3 guide"
          }
        ],
        "example": {
          "title": "Worked example",
          "text": "Choose an initial capacity test and pulse resistance baseline for the same specimen. Keep the state of charge, temperature and instrument channels comparable so later repeat measurements can reveal changes."
        },
        "guide": [
          {
            "title": "Performance and efficiency",
            "terms": [
              "capacity-test",
              "rate-test",
              "ocv-test",
              "pulse-test",
              "hppc",
              "dcir",
              "acir",
              "fast-charge-capability-test",
              "round-trip-efficiency-test",
              "drive-cycle-battery-test"
            ]
          },
          {
            "title": "Aging and thermal measurements",
            "terms": [
              "cycle-life-test",
              "calendar-life-test",
              "reference-performance-test",
              "self-discharge-test",
              "thermal-characterisation",
              "isothermal-calorimetry",
              "accelerating-rate-calorimetry"
            ]
          },
          {
            "title": "Electrochemical and material diagnostics",
            "terms": [
              "electrochemical-impedance-spectroscopy",
              "gitt",
              "pitt",
              "cyclic-voltammetry",
              "chronoamperometry",
              "chronopotentiometry",
              "ultra-high-precision-coulometry",
              "differential-voltage-analysis",
              "incremental-capacity-analysis",
              "laser-flash-analysis",
              "hot-disk-method",
              "ultrasonic-cell-testing",
              "x-ray-computed-tomography",
              "post-mortem"
            ]
          },
          {
            "title": "Manufacturing and battery management",
            "terms": [
              "end-of-line-testing",
              "electrode-peel-test",
              "tab-pull-test",
              "helium-leak-test",
              "swelling-test",
              "fault-injection-testing",
              "insulation-test",
              "dielectric-withstand-test"
            ]
          },
          {
            "title": "Environment and mechanics",
            "terms": [
              "altitude-simulation-test",
              "thermal-shock-test",
              "vibration-test",
              "mechanical-shock-test",
              "damp-heat-test",
              "salt-spray-test",
              "immersion-test",
              "halt-hass",
              "impact-test"
            ]
          },
          {
            "title": "Safety and abuse",
            "terms": [
              "abuse-testing",
              "oven-test",
              "crush-test",
              "nail-penetration",
              "overcharge-test",
              "short-circuit-test",
              "propagation-test",
              "vehicle-crash-test",
              "transport-impact-crush-test",
              "forced-discharge-test"
            ]
          },
          {
            "title": "Transport and qualification references",
            "terms": [
              "transport-regulations",
              "iec-62660",
              "iso-12405",
              "iec-62133",
              "iec-62619",
              "un-r100",
              "ul-9540a"
            ]
          }
        ],
        "url": "https://lemonergy.com/learn/glossary/testing/",
        "mentions": []
      }
    },
    {
      "id": "term:bidirectional-dc-supply",
      "type": "Term",
      "label": "Bidirectional DC power supply",
      "properties": {
        "id": "bidirectional-dc-supply",
        "name": "Bidirectional DC power supply",
        "section": "topic-testing-equipment",
        "definition": "A bidirectional DC supply sources current to charge a specimen and sinks current during discharge. A regenerative model can return absorbed energy to its approved power system.",
        "related": [
          "cycler",
          "electronic-load",
          "hppc",
          "battery-test-equipment"
        ],
        "example": {
          "title": "Worked example",
          "text": "In a single pack drive-cycle trace, check that the commanded sign changes between charge and discharge, and that the instrument records the measured current at each transition."
        },
        "url": "https://lemonergy.com/learn/glossary/bidirectional-dc-supply/",
        "mentions": []
      }
    },
    {
      "id": "term:battery-data-acquisition",
      "type": "Term",
      "label": "Battery data acquisition system",
      "properties": {
        "id": "battery-data-acquisition",
        "name": "Battery data acquisition system",
        "section": "topic-testing-equipment",
        "definition": "A data acquisition system records and synchronizes channels such as voltage, temperature, current, pressure and displacement. Isolation, bandwidth and time alignment matter when different instruments observe the same event.",
        "related": [
          "thermocouples-rtds",
          "voltage-sense",
          "kelvin-sensing",
          "pulse-test",
          "battery-test-equipment"
        ],
        "example": {
          "title": "Worked example",
          "text": "During a fictional pulse, the voltage jumps before a slow temperature sensor changes. Record trigger time and each channel's sample rate to distinguish timing offsets from real thermal delay."
        },
        "url": "https://lemonergy.com/learn/glossary/battery-data-acquisition/",
        "mentions": []
      }
    },
    {
      "id": "term:battery-coolant-conditioner",
      "type": "Term",
      "label": "Battery coolant conditioning unit",
      "properties": {
        "id": "battery-coolant-conditioner",
        "name": "Battery coolant conditioning unit",
        "section": "topic-testing-equipment",
        "definition": "A coolant conditioning unit controls the inlet fluid conditions for a liquid-cooled module or pack. Flow and inlet and outlet temperatures document the imposed thermal boundary during performance testing.",
        "related": [
          "thermal-characterisation",
          "charge-acceptance",
          "battery-data-acquisition",
          "battery-test-equipment"
        ],
        "example": {
          "title": "Worked example",
          "text": "When two current profiles are compared, matching coolant inlet temperature alone is insufficient. The report also records flow rate and outlet temperature so heat removal can be interpreted."
        },
        "url": "https://lemonergy.com/learn/glossary/battery-coolant-conditioner/",
        "mentions": []
      }
    },
    {
      "id": "term:energy-efficiency",
      "type": "Term",
      "label": "Energy efficiency",
      "properties": {
        "id": "energy-efficiency",
        "name": "Energy efficiency",
        "aka": [
          "round-trip efficiency"
        ],
        "section": "topic-ratings",
        "definition": "Energy out divided by energy in over a full cycle. It is lower than coulombic efficiency because the charge voltage sits above the discharge voltage; cells reach 95–98 %, and a full storage system 85–92 % after power electronics and cooling.",
        "unit": "%",
        "related": [
          "coulombic-efficiency",
          "voltage-hysteresis",
          "ir-drop",
          "stationary-storage",
          "voltage-efficiency"
        ],
        "url": "https://lemonergy.com/learn/glossary/energy-efficiency/",
        "mentions": []
      }
    },
    {
      "id": "visual:efficiency-test-energy",
      "type": "Visual",
      "label": "Compare input and recovered energy",
      "properties": {
        "title": "Compare input and recovered energy",
        "summary": "Read cumulative energy at the declared battery boundary.",
        "readout": "The example returns 88 Wh for 100 Wh supplied.",
        "formula": "η = E_out / E_in",
        "note": "Synthetic teaching cycle. State at the boundary is assumed equivalent before and after; auxiliary losses depend on the chosen boundary.",
        "software": {
          "status": "reference",
          "label": "Reference concept",
          "body": "Compare measured or simulated energy over a cycle using the same boundary and start and end conditions.",
          "href": "../chapter-1/"
        },
        "html": "<figure class=\"visual-figure\"><figcaption>Cumulative boundary energy</figcaption><svg class=\"visual-chart\" viewBox=\"0 0 360 330\" role=\"img\" aria-labelledby=\"static-efficiency-test-energy-0-title static-efficiency-test-energy-0-desc\"><title id=\"static-efficiency-test-energy-0-title\">Cumulative boundary energy</title><desc id=\"static-efficiency-test-energy-0-desc\">Relative elapsed time versus Energy (Wh). Incoming energy; Returned energy. Interpretation follows the graphs.</desc><path d=\"M74,238h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"242\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">0</text><text x=\"74\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0</text><path d=\"M74,188.5h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"192.5\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">27.5</text><text x=\"141\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0.25</text><path d=\"M74,139h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"143\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">55</text><text x=\"208\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0.5</text><path d=\"M74,89.5h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"93.5\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">82.5</text><text x=\"275\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0.75</text><path d=\"M74,40h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"44\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">110</text><text x=\"342\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">1</text><path d=\"M74,40v198h268\" fill=\"none\" stroke=\"currentColor\" opacity=\".3\"/><polyline fill=\"none\" stroke=\"#2459a8\" stroke-width=\"2.8\" points=\"74.00,238.00 181.20,58.00 342.00,58.00\"/><polyline fill=\"none\" stroke=\"#6953a8\" stroke-width=\"2.8\" stroke-dasharray=\"7 4\" points=\"74.00,238.00 221.40,238.00 328.60,79.60 342.00,79.60\"/><text transform=\"translate(208 303)\" text-anchor=\"middle\" font-size=\"14\" fill=\"currentColor\"><tspan x=\"0\" dy=\"0\">Relative elapsed time</tspan></text><text transform=\"translate(20 139) rotate(-90)\" text-anchor=\"middle\" font-size=\"14\" fill=\"currentColor\"><tspan x=\"0\" dy=\"0\">Energy (Wh)</tspan></text></svg><div class=\"visual-legend\"><span><i style=\"background:#2459a8\"></i>Incoming energy</span><span><i style=\"background:#6953a8\"></i>Returned energy (dashed)</span></div></figure>"
      }
    },
    {
      "id": "reference:sandia-performance",
      "type": "Reference",
      "label": "DOE Energy Storage Handbook, Chapter 16: Energy Storage Performance Testing",
      "properties": {
        "title": "DOE Energy Storage Handbook, Chapter 16: Energy Storage Performance Testing",
        "publisher": "Sandia National Laboratories",
        "url": "https://www.sandia.gov/app/uploads/sites/163/2021/09/ESHB_Ch16_Testing_Rosewater.pdf",
        "type": "Technical handbook chapter",
        "scope": "Section 2.1.2.1 explains capacity, C-rate and the distinction between capacity and energy; also covers pulse characterization.",
        "accessed": "2026-10-27"
      }
    }
  ]
}