  "node": {
    "id": "term:reverse-pulse-charging",
    "type": "Term",
    "label": "Reverse-pulse charging",
    "properties": {
      "id": "reverse-pulse-charging",
      "name": "Reverse-pulse charging",
      "section": "topic-charging",
      "definition": "Reverse-pulse charging inserts brief discharge intervals into a net charging sequence. Charge and discharge pulses are separately limited, and the signed current integral determines the net charge transferred.",
      "related": [
        "pulse-charging",
        "pulse-test",
        "charge-acceptance",
        "charging-strategies"
      ],
      "example": {
        "title": "Worked example",
        "text": "When an illustrative duty cycle spends half its time at positive full-scale current and one-quarter at negative half-scale current, the net average is 0.375 of full scale."
      },
      "url": "https://lemonergy.com/learn/glossary/reverse-pulse-charging/",
      "mentions": []
    }
  },
  "edges": [
    {
      "id": "edge:belongsTo/term:reverse-pulse-charging/topic:topic-charging",
      "source": "term:reverse-pulse-charging",
      "target": "topic:topic-charging",
      "type": "belongsTo",
      "properties": {
        "sourceFile": "terms.json"
      }
    },
    {
      "id": "edge:relatedTo/term:reverse-pulse-charging/term:pulse-charging",
      "source": "term:reverse-pulse-charging",
      "target": "term:pulse-charging",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:reverse-pulse-charging/term:pulse-test",
      "source": "term:reverse-pulse-charging",
      "target": "term:pulse-test",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:reverse-pulse-charging/term:charge-acceptance",
      "source": "term:reverse-pulse-charging",
      "target": "term:charge-acceptance",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:reverse-pulse-charging/term:charging-strategies",
      "source": "term:reverse-pulse-charging",
      "target": "term:charging-strategies",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:illustratedBy/term:reverse-pulse-charging/visual:reverse-pulse-profile",
      "source": "term:reverse-pulse-charging",
      "target": "visual:reverse-pulse-profile",
      "type": "illustratedBy",
      "properties": {
        "sourceFile": "visual-pages.json"
      }
    },
    {
      "id": "edge:cites/term:reverse-pulse-charging/reference:tomaszewska-charging",
      "source": "term:reverse-pulse-charging",
      "target": "reference:tomaszewska-charging",
      "type": "cites",
      "properties": {
        "sourceFile": "wiki-references.json",
        "scope": "direct technical reference"
      }
    }
  ],
  "neighbors": [
    {
      "id": "topic:topic-charging",
      "type": "Topic",
      "label": "Charging and discharging",
      "properties": {
        "id": "topic-charging",
        "name": "Charging and discharging",
        "lede": "How current goes in and comes out, and the limits that stop it.",
        "context": "Separate regulation from availability.",
        "example": "The same CC–CV law can operate overnight or during a short depot stop.",
        "lesson_url": "https://lemonergy.com/learn/fundamentals/capacity-and-c-rate/",
        "lesson_label": "Open charging quantities"
      }
    },
    {
      "id": "term:pulse-charging",
      "type": "Term",
      "label": "Pulse charging",
      "properties": {
        "id": "pulse-charging",
        "name": "Pulse charging",
        "aka": [
          "burp charging",
          "reflex charging",
          "negative pulse charging"
        ],
        "section": "topic-charging",
        "definition": "Charging with current pulses separated by rests or short discharges, intended to let concentration gradients relax and reduce plating. Benefits for lithium-ion are modest and depend on the cell; it is not standard practice.",
        "related": [
          "fast-charging",
          "lithium-plating",
          "relaxation",
          "charging-strategies"
        ],
        "example": {
          "title": "Separate peak from average current",
          "text": "A 4 A charge pulse that is on for 10 s and off for 10 s has a 2 A average over one full period. Its peak current is still 4 A. Matching average current alone does not match instantaneous heating or electrochemical response."
        },
        "url": "https://lemonergy.com/learn/glossary/pulse-charging/",
        "mentions": []
      }
    },
    {
      "id": "term:pulse-test",
      "type": "Term",
      "label": "Pulse test",
      "properties": {
        "id": "pulse-test",
        "name": "Pulse test",
        "aka": [
          "current pulse test",
          "DC pulse"
        ],
        "section": "topic-testing",
        "definition": "Applying a current step of defined size and duration and recording the voltage response. The instant voltage step gives the ohmic resistance, the following curve the slower polarization; HPPC is a standardised sequence of such pulses across state of charge.",
        "related": [
          "hppc",
          "dcir",
          "internal-resistance",
          "relaxation",
          "equivalent-circuit-model",
          "cycler"
        ],
        "example": {
          "title": "What the report shows",
          "text": "The test record connects the specimen and conditions to the observation. Report current, voltage, sample rate, pulse width, sampling window, temperature and direction. A pulse resistance without a measurement time is ambiguous."
        },
        "procedure": {
          "equipment": [
            "cycler",
            "bidirectional-dc-supply",
            "battery-data-acquisition"
          ],
          "steps": [
            "Stabilize SOC and temperature and record a pre-pulse baseline.",
            "Apply the approved current waveform and time-align current and voltage including the initial edge.",
            "Monitor relaxation and evaluate the voltage change at the declared elapsed time."
          ],
          "record": "Report current, voltage, sample rate, pulse width, sampling window, temperature and direction. A pulse resistance without a measurement time is ambiguous."
        },
        "url": "https://lemonergy.com/learn/glossary/pulse-test/",
        "mentions": [
          "polarization",
          "state-of-charge"
        ]
      }
    },
    {
      "id": "term:charge-acceptance",
      "type": "Term",
      "label": "Charge acceptance",
      "properties": {
        "id": "charge-acceptance",
        "name": "Charge acceptance",
        "section": "topic-charging",
        "definition": "How much of the current offered to a battery it can actually absorb at a given state of charge and temperature. It falls as the battery fills and as it cools, which is why regenerative braking and fast charging are limited by the battery rather than the source.",
        "related": [
          "fast-charging",
          "regenerative-braking",
          "state-of-power",
          "derating",
          "charging-strategies"
        ],
        "url": "https://lemonergy.com/learn/glossary/charge-acceptance/",
        "mentions": [
          "state-of-charge"
        ]
      }
    },
    {
      "id": "term:charging-strategies",
      "type": "Term",
      "label": "Battery charging strategies",
      "properties": {
        "id": "charging-strategies",
        "name": "Battery charging strategies",
        "section": "topic-charging",
        "definition": "Battery charging strategies define how a charger commands current, voltage or power and how it decides to change stages or stop. Chemistry, temperature, battery state and infrastructure also determine which strategies are applicable.",
        "related": [
          "cc-cv-charging",
          "mscc",
          "adaptive-charging",
          "lead-acid-bulk-absorption-float",
          "battery-test-equipment",
          "testing"
        ],
        "example": {
          "title": "Worked example",
          "text": "Compare a current-limited session, a power-limited session and a stepped current schedule at the same starting state of charge. Look for phase transitions and record the achieved charge separately from the peak current."
        },
        "guide": [
          {
            "title": "Basic electrical profiles",
            "terms": [
              "constant-current",
              "constant-voltage",
              "cc-cv-charging",
              "constant-power-charging",
              "cp-cv",
              "mscc",
              "mscc-cv",
              "ramped-current-charging",
              "taper-charging"
            ]
          },
          {
            "title": "Pulse and feedback profiles",
            "terms": [
              "pulse-charging",
              "reverse-pulse-charging",
              "adaptive-charging",
              "model-predictive-charging",
              "non-linear-voltammetry-charging"
            ]
          },
          {
            "title": "Temperature and charging speed",
            "terms": [
              "temperature-conditioned-charging",
              "preconditioning",
              "slow-charging",
              "fast-charging",
              "xfc",
              "dc-fast-charging",
              "charge-acceptance"
            ]
          },
          {
            "title": "Start, stop and maintenance",
            "terms": [
              "precharge-recharge",
              "target-soc-charging",
              "boost-charging",
              "trickle-charge",
              "float-charging",
              "lead-acid-bulk-absorption-float",
              "equalization-charge",
              "nickel-peak-termination",
              "iu-charging-characteristics",
              "negative-delta-v",
              "dt-dt-termination",
              "charge-termination",
              "refresh-charge",
              "reconditioning"
            ]
          },
          {
            "title": "Vehicle and site strategies",
            "terms": [
              "smart-charging",
              "scheduled-charging",
              "depot-charging",
              "opportunity-charging",
              "split-pack-charging",
              "regenerative-braking"
            ]
          }
        ],
        "url": "https://lemonergy.com/learn/glossary/charging-strategies/",
        "mentions": [
          "charger"
        ]
      }
    },
    {
      "id": "visual:reverse-pulse-profile",
      "type": "Visual",
      "label": "Positive and negative current in the same cycle",
      "properties": {
        "title": "Positive and negative current in the same cycle",
        "summary": "Compare the positive charge pulse with a brief discharge interval using one sign convention.",
        "readout": "Positive pulses occupy half the example. The average signed current is 0.375 of the positive peak.",
        "formula": "Average = 0.50 × positive peak − 0.25 × reverse magnitude",
        "note": "Original normalized teaching traces. They omit cell calibration and do not specify charger settings or predict charge time, aging or safety.",
        "software": {
          "status": "reference",
          "label": "Reference concept",
          "body": "The article links any separately verified Lemonergy workflow. These curves are independent teaching examples.",
          "href": "../glossary/charging-strategies/"
        },
        "html": "<figure class=\"visual-figure\"><figcaption>Signed current</figcaption><svg class=\"visual-chart\" viewBox=\"0 0 360 330\" role=\"img\" aria-labelledby=\"static-reverse-pulse-profile-0-title static-reverse-pulse-profile-0-desc\"><title id=\"static-reverse-pulse-profile-0-title\">Signed current</title><desc id=\"static-reverse-pulse-profile-0-desc\">Relative elapsed time versus Relative current. Charge (+) and discharge (−); Net average. Interpretation follows the graphs.</desc><path d=\"M74,238h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"242\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">-1</text><text x=\"74\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0</text><path d=\"M74,188.5h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"192.5\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">-0.475</text><text x=\"141\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0.25</text><path d=\"M74,139h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"143\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">0.05</text><text x=\"208\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0.5</text><path d=\"M74,89.5h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"93.5\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">0.575</text><text x=\"275\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0.75</text><path d=\"M74,40h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"44\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">1.1</text><text x=\"342\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">1</text><path d=\"M74,40v198h268\" fill=\"none\" stroke=\"currentColor\" opacity=\".3\"/><polyline fill=\"none\" stroke=\"#2459a8\" stroke-width=\"2.8\" points=\"74.00,49.43 107.50,49.43 107.50,143.71 124.25,143.71 124.25,190.86 141.00,190.86 141.00,49.43 174.50,49.43 174.50,143.71 191.25,143.71 191.25,190.86 208.00,190.86 208.00,49.43 241.50,49.43 241.50,143.71 258.25,143.71 258.25,190.86 275.00,190.86 275.00,49.43 308.50,49.43 308.50,143.71 325.25,143.71 325.25,190.86 342.00,190.86\"/><polyline fill=\"none\" stroke=\"#6953a8\" stroke-width=\"2.8\" stroke-dasharray=\"7 4\" points=\"74.00,108.36 342.00,108.36\"/><text transform=\"translate(208 303)\" text-anchor=\"middle\" font-size=\"14\" fill=\"currentColor\"><tspan x=\"0\" dy=\"0\">Relative elapsed time</tspan></text><text transform=\"translate(20 139) rotate(-90)\" text-anchor=\"middle\" font-size=\"14\" fill=\"currentColor\"><tspan x=\"0\" dy=\"0\">Relative current</tspan></text></svg><div class=\"visual-legend\"><span><i style=\"background:#2459a8\"></i>Charge (+) and discharge (−)</span><span><i style=\"background:#6953a8\"></i>Net average (dashed)</span></div></figure>"
      }
    },
    {
      "id": "reference:tomaszewska-charging",
      "type": "Reference",
      "label": "Lithium-ion battery fast charging: A review",
      "properties": {
        "title": "Lithium-ion battery fast charging: A review",
        "publisher": "eTransportation",
        "url": "https://doi.org/10.1016/j.etran.2019.100011",
        "type": "Review article",
        "scope": "CC-CV and alternative charging protocols, transport limitations, degradation and thermal implications; results depend on cell and test conditions. Software behavior is documented separately in Lemonergy block references.",
        "year": 2019,
        "authors": [
          "Anna Tomaszewska et al."
        ],
        "accessed": "2026-10-27"
      }
    }
  ]
}