  "node": {
    "id": "term:precharge-recharge",
    "type": "Term",
    "label": "Low-voltage precharge and automatic recharge",
    "properties": {
      "id": "precharge-recharge",
      "name": "Low-voltage precharge and automatic recharge",
      "section": "topic-charging",
      "definition": "A compatible charging controller can start eligible low-voltage cells at reduced current and later enter normal charging. Automatic recharge is a separate restart after the battery falls below a defined threshold following termination.",
      "related": [
        "cc-cv-charging",
        "cutoff-voltage",
        "boost-charging",
        "charging-strategies"
      ],
      "example": {
        "title": "Worked example",
        "text": "Read the low-current opening stage and the zero-current interval after termination as different states. The next ordinary charging stage starts only after the fictional restart condition is met."
      },
      "url": "https://lemonergy.com/learn/glossary/precharge-recharge/",
      "mentions": []
    }
  },
  "edges": [
    {
      "id": "edge:belongsTo/term:precharge-recharge/topic:topic-charging",
      "source": "term:precharge-recharge",
      "target": "topic:topic-charging",
      "type": "belongsTo",
      "properties": {
        "sourceFile": "terms.json"
      }
    },
    {
      "id": "edge:relatedTo/term:precharge-recharge/term:cc-cv-charging",
      "source": "term:precharge-recharge",
      "target": "term:cc-cv-charging",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:precharge-recharge/term:cutoff-voltage",
      "source": "term:precharge-recharge",
      "target": "term:cutoff-voltage",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:precharge-recharge/term:boost-charging",
      "source": "term:precharge-recharge",
      "target": "term:boost-charging",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:precharge-recharge/term:charging-strategies",
      "source": "term:precharge-recharge",
      "target": "term:charging-strategies",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:illustratedBy/term:precharge-recharge/visual:recovery-and-restart",
      "source": "term:precharge-recharge",
      "target": "visual:recovery-and-restart",
      "type": "illustratedBy",
      "properties": {
        "sourceFile": "visual-pages.json"
      }
    },
    {
      "id": "edge:cites/term:precharge-recharge/reference:ti-li-charge",
      "source": "term:precharge-recharge",
      "target": "reference:ti-li-charge",
      "type": "cites",
      "properties": {
        "sourceFile": "wiki-references.json",
        "scope": "direct technical reference"
      }
    }
  ],
  "neighbors": [
    {
      "id": "topic:topic-charging",
      "type": "Topic",
      "label": "Charging and discharging",
      "properties": {
        "id": "topic-charging",
        "name": "Charging and discharging",
        "lede": "How current goes in and comes out, and the limits that stop it.",
        "context": "Separate regulation from availability.",
        "example": "The same CC–CV law can operate overnight or during a short depot stop.",
        "lesson_url": "https://lemonergy.com/learn/fundamentals/capacity-and-c-rate/",
        "lesson_label": "Open charging quantities"
      }
    },
    {
      "id": "term:cc-cv-charging",
      "type": "Term",
      "label": "CC-CV charging",
      "properties": {
        "id": "cc-cv-charging",
        "name": "CC-CV charging",
        "aka": [
          "constant current constant voltage"
        ],
        "section": "topic-charging",
        "definition": "The standard lithium-ion charge protocol: constant current until the cell reaches its upper cutoff voltage, then that voltage held constant while the current tapers. The charge ends when the current falls to a set fraction, often C/20.",
        "related": [
          "constant-current",
          "constant-voltage",
          "cutoff-voltage",
          "taper-current",
          "fast-charging",
          "cp-cv"
        ],
        "lesson": "fundamentals/capacity-and-c-rate/#real-cells",
        "example": {
          "title": "Follow a two-stage charge",
          "text": "For an illustrative 5 Ah cell, a 2.5 A current request is 0.5C. During CC the voltage rises. At the selected upper voltage, CV regulation holds voltage while current tapers. Completion requires the taper current to fall below the selected cutoff for the configured dwell."
        },
        "notes": [
          "Choose voltage, current and temperature limits from the actual cell specification. These example values do not define a charging recipe."
        ],
        "url": "https://lemonergy.com/learn/glossary/cc-cv-charging/",
        "mentions": []
      }
    },
    {
      "id": "term:cutoff-voltage",
      "type": "Term",
      "label": "Cutoff voltage",
      "properties": {
        "id": "cutoff-voltage",
        "name": "Cutoff voltage",
        "aka": [
          "end-point voltage",
          "end-of-discharge voltage",
          "final voltage",
          "end voltage"
        ],
        "section": "topic-charging",
        "definition": "The terminal-voltage limit that ends a discharge, or caps a charge — in constant-current, constant-voltage (CC-CV) charging the cell is then held at that voltage until the current falls to a cutoff. A real discharge ends at the lower cutoff, which is why actual runtime can differ from the ideal duration.",
        "unit": "V",
        "related": [
          "voltage-window",
          "cc-cv-charging",
          "ideal-duration",
          "over-discharge",
          "overcharge"
        ],
        "lesson": "fundamentals/capacity-and-c-rate/#real-cells",
        "url": "https://lemonergy.com/learn/glossary/cutoff-voltage/",
        "mentions": [
          "service-life"
        ]
      }
    },
    {
      "id": "term:boost-charging",
      "type": "Term",
      "label": "Boost and top-up charging",
      "properties": {
        "id": "boost-charging",
        "name": "Boost and top-up charging",
        "section": "topic-charging",
        "definition": "A short, partial charge to add range quickly — often only into the part of the SOC window where the cell accepts high current best, typically 10–80 %. Charging above 80 % is slow on any fast charger, so frequent short top-ups are often faster than one long session.",
        "related": [
          "charging-curve",
          "fast-charging",
          "opportunity-charging",
          "usable-capacity",
          "charging-strategies"
        ],
        "url": "https://lemonergy.com/learn/glossary/boost-charging/",
        "mentions": [
          "charger",
          "state-of-charge"
        ]
      }
    },
    {
      "id": "term:charging-strategies",
      "type": "Term",
      "label": "Battery charging strategies",
      "properties": {
        "id": "charging-strategies",
        "name": "Battery charging strategies",
        "section": "topic-charging",
        "definition": "Battery charging strategies define how a charger commands current, voltage or power and how it decides to change stages or stop. Chemistry, temperature, battery state and infrastructure also determine which strategies are applicable.",
        "related": [
          "cc-cv-charging",
          "mscc",
          "adaptive-charging",
          "lead-acid-bulk-absorption-float",
          "battery-test-equipment",
          "testing"
        ],
        "example": {
          "title": "Worked example",
          "text": "Compare a current-limited session, a power-limited session and a stepped current schedule at the same starting state of charge. Look for phase transitions and record the achieved charge separately from the peak current."
        },
        "guide": [
          {
            "title": "Basic electrical profiles",
            "terms": [
              "constant-current",
              "constant-voltage",
              "cc-cv-charging",
              "constant-power-charging",
              "cp-cv",
              "mscc",
              "mscc-cv",
              "ramped-current-charging",
              "taper-charging"
            ]
          },
          {
            "title": "Pulse and feedback profiles",
            "terms": [
              "pulse-charging",
              "reverse-pulse-charging",
              "adaptive-charging",
              "model-predictive-charging",
              "non-linear-voltammetry-charging"
            ]
          },
          {
            "title": "Temperature and charging speed",
            "terms": [
              "temperature-conditioned-charging",
              "preconditioning",
              "slow-charging",
              "fast-charging",
              "xfc",
              "dc-fast-charging",
              "charge-acceptance"
            ]
          },
          {
            "title": "Start, stop and maintenance",
            "terms": [
              "precharge-recharge",
              "target-soc-charging",
              "boost-charging",
              "trickle-charge",
              "float-charging",
              "lead-acid-bulk-absorption-float",
              "equalization-charge",
              "nickel-peak-termination",
              "iu-charging-characteristics",
              "negative-delta-v",
              "dt-dt-termination",
              "charge-termination",
              "refresh-charge",
              "reconditioning"
            ]
          },
          {
            "title": "Vehicle and site strategies",
            "terms": [
              "smart-charging",
              "scheduled-charging",
              "depot-charging",
              "opportunity-charging",
              "split-pack-charging",
              "regenerative-braking"
            ]
          }
        ],
        "url": "https://lemonergy.com/learn/glossary/charging-strategies/",
        "mentions": [
          "charger"
        ]
      }
    },
    {
      "id": "visual:recovery-and-restart",
      "type": "Visual",
      "label": "Reduced-current precharge and later recharge",
      "properties": {
        "title": "Reduced-current precharge and later recharge",
        "summary": "Distinguish the opening low-current phase from a later recharge event.",
        "readout": "The first low plateau is precharge. The long zero-current interval follows termination. The last partial session illustrates restart or top-up.",
        "formula": "Precharge, regulation, termination, idle and recharge are separate states.",
        "note": "Original normalized teaching traces. They omit cell calibration and do not specify charger settings or predict charge time, aging or safety.",
        "software": {
          "status": "reference",
          "label": "Reference concept",
          "body": "Recovery eligibility and recharge thresholds belong to an approved charger and cell. A low-voltage cell can require rejection.",
          "href": "../glossary/charging-strategies/"
        },
        "html": "<figure class=\"visual-figure\"><figcaption>Example current before and after idle</figcaption><svg class=\"visual-chart\" viewBox=\"0 0 360 330\" role=\"img\" aria-labelledby=\"static-recovery-and-restart-0-title static-recovery-and-restart-0-desc\"><title id=\"static-recovery-and-restart-0-title\">Example current before and after idle</title><desc id=\"static-recovery-and-restart-0-desc\">Relative elapsed time versus Relative current. Charge current. Interpretation follows the graphs.</desc><path d=\"M74,238h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"242\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">0</text><text x=\"74\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0</text><path d=\"M74,188.5h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"192.5\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">0.275</text><text x=\"141\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0.25</text><path d=\"M74,139h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"143\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">0.55</text><text x=\"208\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0.5</text><path d=\"M74,89.5h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"93.5\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">0.825</text><text x=\"275\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0.75</text><path d=\"M74,40h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"44\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">1.1</text><text x=\"342\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">1</text><path d=\"M74,40v198h268\" fill=\"none\" stroke=\"currentColor\" opacity=\".3\"/><polyline fill=\"none\" stroke=\"#2459a8\" stroke-width=\"2.8\" points=\"74.00,202.00 122.24,202.00 122.24,58.00 191.92,58.00 193.46,70.00 195.00,81.20 196.54,91.66 198.08,101.41 199.63,110.52 201.17,119.02 202.71,126.95 204.25,134.36 205.79,141.27 207.33,147.72 208.87,153.74 210.41,159.35 211.95,164.60 213.49,169.49 215.03,174.06 216.58,178.32 218.12,182.30 219.66,186.01 221.20,189.48 222.74,192.72 224.28,195.74 225.82,198.55 227.36,201.18 228.90,203.64 230.44,205.93 231.99,208.07 233.53,210.06 235.07,211.93 236.61,213.66 238.15,215.29 239.69,216.80 241.23,218.21 242.77,219.53 244.31,220.76 245.85,221.91 247.40,222.99 248.94,223.99 250.48,224.92 252.02,225.79 253.56,226.61 253.56,238.00 309.84,238.00 309.84,121.00 342.00,121.00\"/><text transform=\"translate(208 303)\" text-anchor=\"middle\" font-size=\"14\" fill=\"currentColor\"><tspan x=\"0\" dy=\"0\">Relative elapsed time</tspan></text><text transform=\"translate(20 139) rotate(-90)\" text-anchor=\"middle\" font-size=\"14\" fill=\"currentColor\"><tspan x=\"0\" dy=\"0\">Relative current</tspan></text></svg><div class=\"visual-legend\"><span><i style=\"background:#2459a8\"></i>Charge current</span></div></figure>"
      }
    },
    {
      "id": "reference:ti-li-charge",
      "type": "Reference",
      "label": "BQ25895 single-cell charging controller technical documentation",
      "properties": {
        "title": "BQ25895 single-cell charging controller technical documentation",
        "publisher": "Texas Instruments",
        "url": "https://www.ti.com/product/BQ25895",
        "type": "Manufacturer technical documentation",
        "scope": "Example of precharge, CC–CV regulation, termination, recharge and temperature supervision in a lithium-ion charger.",
        "accessed": "2026-11-18"
      }
    }
  ]
}