  "node": {
    "id": "term:mscc-cv",
    "type": "Term",
    "label": "Multistage constant current with CV finish",
    "properties": {
      "id": "mscc-cv",
      "name": "Multistage constant current with CV finish",
      "section": "topic-charging",
      "definition": "A multistage current schedule uses several constant-current plateaus before a final constant-voltage stage. Current then tapers under voltage regulation until an approved termination criterion is met.",
      "related": [
        "mscc",
        "cc-cv-charging",
        "cutoff-voltage",
        "charging-strategies"
      ],
      "example": {
        "title": "Worked example",
        "text": "In a normalized example, three progressively lower current plateaus are followed by a smoothly falling tail. The flat voltage trace identifies the final stage, even though the current was already falling in steps."
      },
      "url": "https://lemonergy.com/learn/glossary/mscc-cv/",
      "mentions": []
    }
  },
  "edges": [
    {
      "id": "edge:belongsTo/term:mscc-cv/topic:topic-charging",
      "source": "term:mscc-cv",
      "target": "topic:topic-charging",
      "type": "belongsTo",
      "properties": {
        "sourceFile": "terms.json"
      }
    },
    {
      "id": "edge:relatedTo/term:mscc-cv/term:mscc",
      "source": "term:mscc-cv",
      "target": "term:mscc",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:mscc-cv/term:cc-cv-charging",
      "source": "term:mscc-cv",
      "target": "term:cc-cv-charging",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:mscc-cv/term:cutoff-voltage",
      "source": "term:mscc-cv",
      "target": "term:cutoff-voltage",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:mscc-cv/term:charging-strategies",
      "source": "term:mscc-cv",
      "target": "term:charging-strategies",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:illustratedBy/term:mscc-cv/visual:staged-cv-profile",
      "source": "term:mscc-cv",
      "target": "visual:staged-cv-profile",
      "type": "illustratedBy",
      "properties": {
        "sourceFile": "visual-pages.json"
      }
    },
    {
      "id": "edge:cites/term:mscc-cv/reference:attia-charge",
      "source": "term:mscc-cv",
      "target": "reference:attia-charge",
      "type": "cites",
      "properties": {
        "sourceFile": "wiki-references.json",
        "scope": "direct technical reference"
      }
    },
    {
      "id": "edge:cites/term:mscc-cv/reference:tomaszewska-charging",
      "source": "term:mscc-cv",
      "target": "reference:tomaszewska-charging",
      "type": "cites",
      "properties": {
        "sourceFile": "wiki-references.json",
        "scope": "direct technical reference"
      }
    }
  ],
  "neighbors": [
    {
      "id": "topic:topic-charging",
      "type": "Topic",
      "label": "Charging and discharging",
      "properties": {
        "id": "topic-charging",
        "name": "Charging and discharging",
        "lede": "How current goes in and comes out, and the limits that stop it.",
        "context": "Separate regulation from availability.",
        "example": "The same CC–CV law can operate overnight or during a short depot stop.",
        "lesson_url": "https://lemonergy.com/learn/fundamentals/capacity-and-c-rate/",
        "lesson_label": "Open charging quantities"
      }
    },
    {
      "id": "term:mscc",
      "type": "Term",
      "label": "Multistage constant-current charging",
      "properties": {
        "id": "mscc",
        "name": "Multistage constant-current charging",
        "abbr": "MSCC",
        "aka": [
          "step charging",
          "stepped CC"
        ],
        "section": "topic-charging",
        "definition": "A charge protocol with a sequence of constant-current stages, often reducing current as the cell fills. Stage transitions follow selected time, voltage, state-of-charge or other limits. Charging time and lithium-plating risk depend on the cell and control conditions; a staged profile alone does not establish an improvement.",
        "related": [
          "cc-cv-charging",
          "fast-charging",
          "lithium-plating",
          "charging-curve",
          "xfc",
          "pulse-charging"
        ],
        "example": {
          "title": "Build a staged current profile",
          "text": "An illustrative sequence uses 3 A for 10 min, then 2 A for 10 min, then 1 A for 10 min. If every stage runs for its full duration, the charge transferred is 1 Ah. Voltage and temperature limits can terminate stages earlier."
        },
        "notes": [
          "A sequence of CC steps is distinct from an automatically combined multistage CC-CV charger."
        ],
        "url": "https://lemonergy.com/learn/glossary/mscc/",
        "mentions": []
      }
    },
    {
      "id": "term:cc-cv-charging",
      "type": "Term",
      "label": "CC-CV charging",
      "properties": {
        "id": "cc-cv-charging",
        "name": "CC-CV charging",
        "aka": [
          "constant current constant voltage"
        ],
        "section": "topic-charging",
        "definition": "The standard lithium-ion charge protocol: constant current until the cell reaches its upper cutoff voltage, then that voltage held constant while the current tapers. The charge ends when the current falls to a set fraction, often C/20.",
        "related": [
          "constant-current",
          "constant-voltage",
          "cutoff-voltage",
          "taper-current",
          "fast-charging",
          "cp-cv"
        ],
        "lesson": "fundamentals/capacity-and-c-rate/#real-cells",
        "example": {
          "title": "Follow a two-stage charge",
          "text": "For an illustrative 5 Ah cell, a 2.5 A current request is 0.5C. During CC the voltage rises. At the selected upper voltage, CV regulation holds voltage while current tapers. Completion requires the taper current to fall below the selected cutoff for the configured dwell."
        },
        "notes": [
          "Choose voltage, current and temperature limits from the actual cell specification. These example values do not define a charging recipe."
        ],
        "url": "https://lemonergy.com/learn/glossary/cc-cv-charging/",
        "mentions": []
      }
    },
    {
      "id": "term:cutoff-voltage",
      "type": "Term",
      "label": "Cutoff voltage",
      "properties": {
        "id": "cutoff-voltage",
        "name": "Cutoff voltage",
        "aka": [
          "end-point voltage",
          "end-of-discharge voltage",
          "final voltage",
          "end voltage"
        ],
        "section": "topic-charging",
        "definition": "The terminal-voltage limit that ends a discharge, or caps a charge — in constant-current, constant-voltage (CC-CV) charging the cell is then held at that voltage until the current falls to a cutoff. A real discharge ends at the lower cutoff, which is why actual runtime can differ from the ideal duration.",
        "unit": "V",
        "related": [
          "voltage-window",
          "cc-cv-charging",
          "ideal-duration",
          "over-discharge",
          "overcharge"
        ],
        "lesson": "fundamentals/capacity-and-c-rate/#real-cells",
        "url": "https://lemonergy.com/learn/glossary/cutoff-voltage/",
        "mentions": [
          "service-life"
        ]
      }
    },
    {
      "id": "term:charging-strategies",
      "type": "Term",
      "label": "Battery charging strategies",
      "properties": {
        "id": "charging-strategies",
        "name": "Battery charging strategies",
        "section": "topic-charging",
        "definition": "Battery charging strategies define how a charger commands current, voltage or power and how it decides to change stages or stop. Chemistry, temperature, battery state and infrastructure also determine which strategies are applicable.",
        "related": [
          "cc-cv-charging",
          "mscc",
          "adaptive-charging",
          "lead-acid-bulk-absorption-float",
          "battery-test-equipment",
          "testing"
        ],
        "example": {
          "title": "Worked example",
          "text": "Compare a current-limited session, a power-limited session and a stepped current schedule at the same starting state of charge. Look for phase transitions and record the achieved charge separately from the peak current."
        },
        "guide": [
          {
            "title": "Basic electrical profiles",
            "terms": [
              "constant-current",
              "constant-voltage",
              "cc-cv-charging",
              "constant-power-charging",
              "cp-cv",
              "mscc",
              "mscc-cv",
              "ramped-current-charging",
              "taper-charging"
            ]
          },
          {
            "title": "Pulse and feedback profiles",
            "terms": [
              "pulse-charging",
              "reverse-pulse-charging",
              "adaptive-charging",
              "model-predictive-charging",
              "non-linear-voltammetry-charging"
            ]
          },
          {
            "title": "Temperature and charging speed",
            "terms": [
              "temperature-conditioned-charging",
              "preconditioning",
              "slow-charging",
              "fast-charging",
              "xfc",
              "dc-fast-charging",
              "charge-acceptance"
            ]
          },
          {
            "title": "Start, stop and maintenance",
            "terms": [
              "precharge-recharge",
              "target-soc-charging",
              "boost-charging",
              "trickle-charge",
              "float-charging",
              "lead-acid-bulk-absorption-float",
              "equalization-charge",
              "nickel-peak-termination",
              "iu-charging-characteristics",
              "negative-delta-v",
              "dt-dt-termination",
              "charge-termination",
              "refresh-charge",
              "reconditioning"
            ]
          },
          {
            "title": "Vehicle and site strategies",
            "terms": [
              "smart-charging",
              "scheduled-charging",
              "depot-charging",
              "opportunity-charging",
              "split-pack-charging",
              "regenerative-braking"
            ]
          }
        ],
        "url": "https://lemonergy.com/learn/glossary/charging-strategies/",
        "mentions": [
          "charger"
        ]
      }
    },
    {
      "id": "visual:staged-cv-profile",
      "type": "Visual",
      "label": "Several current steps, then a voltage hold",
      "properties": {
        "title": "Several current steps, then a voltage hold",
        "summary": "Follow the transition from a staged current schedule to voltage control.",
        "readout": "The current has three plateaus. Voltage becomes flat during the final stage, while current continues to taper before termination.",
        "formula": "CC stages hold their individual current targets; the CV stage holds voltage.",
        "note": "Original normalized teaching traces. They omit cell calibration and do not specify charger settings or predict charge time, aging or safety.",
        "software": {
          "status": "reference",
          "label": "Reference concept",
          "body": "The article links any separately verified Lemonergy workflow. These curves are independent teaching examples.",
          "href": "../glossary/charging-strategies/"
        },
        "html": "<figure class=\"visual-figure\"><figcaption>Current steps and CV taper</figcaption><svg class=\"visual-chart\" viewBox=\"0 0 360 330\" role=\"img\" aria-labelledby=\"static-staged-cv-profile-0-title static-staged-cv-profile-0-desc\"><title id=\"static-staged-cv-profile-0-title\">Current steps and CV taper</title><desc id=\"static-staged-cv-profile-0-desc\">Relative elapsed time versus Relative current. Charge current. Interpretation follows the graphs.</desc><path d=\"M74,238h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"242\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">0</text><text x=\"74\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0</text><path d=\"M74,188.5h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"192.5\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">0.275</text><text x=\"141\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0.25</text><path d=\"M74,139h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"143\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">0.55</text><text x=\"208\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0.5</text><path d=\"M74,89.5h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"93.5\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">0.825</text><text x=\"275\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0.75</text><path d=\"M74,40h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"44\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">1.1</text><text x=\"342\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">1</text><path d=\"M74,40v198h268\" fill=\"none\" stroke=\"currentColor\" opacity=\".3\"/><polyline fill=\"none\" stroke=\"#2459a8\" stroke-width=\"2.8\" points=\"74.00,58.00 132.96,58.00 132.96,108.40 194.60,108.40 194.60,162.40 250.88,162.40 252.55,166.52 254.22,170.41 255.88,174.09 257.55,177.57 259.22,180.86 260.89,183.97 262.55,186.92 264.22,189.70 265.89,192.33 267.56,194.82 269.22,197.17 270.89,199.39 272.56,201.49 274.23,203.48 275.89,205.36 277.56,207.14 279.23,208.82 280.90,210.41 282.56,211.91 284.23,213.33 285.90,214.68 287.57,215.95 289.23,217.15 290.90,218.28 292.57,219.36 294.24,220.37 295.90,221.33 297.57,222.24 299.24,223.10 300.91,223.91 302.57,224.68 304.24,225.40 305.91,226.09 307.58,226.74 309.24,227.35 310.91,227.93 312.58,228.48 314.25,229.00 315.91,229.49 317.58,229.95 319.25,230.39 320.92,230.80 322.58,231.20 324.25,231.57 325.92,231.92 325.92,238.00 342.00,238.00\"/><text transform=\"translate(208 303)\" text-anchor=\"middle\" font-size=\"14\" fill=\"currentColor\"><tspan x=\"0\" dy=\"0\">Relative elapsed time</tspan></text><text transform=\"translate(20 139) rotate(-90)\" text-anchor=\"middle\" font-size=\"14\" fill=\"currentColor\"><tspan x=\"0\" dy=\"0\">Relative current</tspan></text></svg><div class=\"visual-legend\"><span><i style=\"background:#2459a8\"></i>Charge current</span></div></figure>\n<figure class=\"visual-figure\"><figcaption>Voltage before and during the hold</figcaption><svg class=\"visual-chart\" viewBox=\"0 0 360 330\" role=\"img\" aria-labelledby=\"static-staged-cv-profile-1-title static-staged-cv-profile-1-desc\"><title id=\"static-staged-cv-profile-1-title\">Voltage before and during the hold</title><desc id=\"static-staged-cv-profile-1-desc\">Relative elapsed time versus Relative voltage. Cell voltage. Interpretation follows the graphs.</desc><path d=\"M74,238h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"242\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">0</text><text x=\"74\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0</text><path d=\"M74,188.5h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"192.5\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">0.275</text><text x=\"141\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0.25</text><path d=\"M74,139h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"143\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">0.55</text><text x=\"208\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0.5</text><path d=\"M74,89.5h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"93.5\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">0.825</text><text x=\"275\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0.75</text><path d=\"M74,40h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"44\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">1.1</text><text x=\"342\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">1</text><path d=\"M74,40v198h268\" fill=\"none\" stroke=\"currentColor\" opacity=\".3\"/><polyline fill=\"none\" stroke=\"#6953a8\" stroke-width=\"2.8\" points=\"74.00,193.00 132.96,133.60 194.60,90.40 250.88,58.00 325.92,58.00\"/><text transform=\"translate(208 303)\" text-anchor=\"middle\" font-size=\"14\" fill=\"currentColor\"><tspan x=\"0\" dy=\"0\">Relative elapsed time</tspan></text><text transform=\"translate(20 139) rotate(-90)\" text-anchor=\"middle\" font-size=\"14\" fill=\"currentColor\"><tspan x=\"0\" dy=\"0\">Relative voltage</tspan></text></svg><div class=\"visual-legend\"><span><i style=\"background:#6953a8\"></i>Cell voltage</span></div></figure>"
      }
    },
    {
      "id": "reference:attia-charge",
      "type": "Reference",
      "label": "Closed-loop optimization of fast-charging protocols for batteries with machine learning",
      "properties": {
        "title": "Closed-loop optimization of fast-charging protocols for batteries with machine learning",
        "publisher": "Nature",
        "url": "https://www.nature.com/articles/s41586-020-1994-5",
        "type": "Primary research",
        "scope": "Experimental selection of multistep lithium-ion charging profiles. Figure shape and settings here are independently authored.",
        "accessed": "2026-11-18"
      }
    },
    {
      "id": "reference:tomaszewska-charging",
      "type": "Reference",
      "label": "Lithium-ion battery fast charging: A review",
      "properties": {
        "title": "Lithium-ion battery fast charging: A review",
        "publisher": "eTransportation",
        "url": "https://doi.org/10.1016/j.etran.2019.100011",
        "type": "Review article",
        "scope": "CC-CV and alternative charging protocols, transport limitations, degradation and thermal implications; results depend on cell and test conditions. Software behavior is documented separately in Lemonergy block references.",
        "year": 2019,
        "authors": [
          "Anna Tomaszewska et al."
        ],
        "accessed": "2026-10-27"
      }
    }
  ]
}