  "node": {
    "id": "term:mechanical-shock-test",
    "type": "Term",
    "label": "Battery mechanical shock test",
    "properties": {
      "id": "mechanical-shock-test",
      "name": "Battery mechanical shock test",
      "section": "topic-testing",
      "definition": "A mechanical shock test observes a battery's response to a short mechanical acceleration event. It differs from sustained vibration testing and from local impact or crush tests.",
      "related": [
        "battery-shaker",
        "battery-data-acquisition",
        "battery-cell-fixture",
        "testing"
      ],
      "example": {
        "title": "What the report shows",
        "text": "The test record connects the specimen and conditions to the observation. Retain the acceleration record, orientations and specimen observations. UN 38.3 T.4 is a transport shock test, with applicability defined by the manual."
      },
      "procedure": {
        "equipment": [
          "battery-shaker",
          "battery-data-acquisition",
          "battery-cell-fixture"
        ],
        "steps": [
          "Confirm the applicable method and identify the fixture and measurement axes.",
          "The lab applies and records mechanical shock under its approved procedure.",
          "Review the measured shock and compare specimen condition before and after."
        ],
        "record": "Retain the acceleration record, orientations and specimen observations. UN 38.3 T.4 is a transport shock test, with applicability defined by the manual."
      },
      "url": "https://lemonergy.com/learn/glossary/mechanical-shock-test/",
      "mentions": []
    }
  },
  "edges": [
    {
      "id": "edge:belongsTo/term:mechanical-shock-test/topic:topic-testing",
      "source": "term:mechanical-shock-test",
      "target": "topic:topic-testing",
      "type": "belongsTo",
      "properties": {
        "sourceFile": "terms.json"
      }
    },
    {
      "id": "edge:relatedTo/term:mechanical-shock-test/term:battery-shaker",
      "source": "term:mechanical-shock-test",
      "target": "term:battery-shaker",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:mechanical-shock-test/term:battery-data-acquisition",
      "source": "term:mechanical-shock-test",
      "target": "term:battery-data-acquisition",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:mechanical-shock-test/term:battery-cell-fixture",
      "source": "term:mechanical-shock-test",
      "target": "term:battery-cell-fixture",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:mechanical-shock-test/term:testing",
      "source": "term:mechanical-shock-test",
      "target": "term:testing",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:usesTestEquipment/term:mechanical-shock-test/term:battery-shaker",
      "source": "term:mechanical-shock-test",
      "target": "term:battery-shaker",
      "type": "usesTestEquipment",
      "properties": {
        "sourceFile": "wiki-editorial.json"
      }
    },
    {
      "id": "edge:usesTestEquipment/term:mechanical-shock-test/term:battery-data-acquisition",
      "source": "term:mechanical-shock-test",
      "target": "term:battery-data-acquisition",
      "type": "usesTestEquipment",
      "properties": {
        "sourceFile": "wiki-editorial.json"
      }
    },
    {
      "id": "edge:usesTestEquipment/term:mechanical-shock-test/term:battery-cell-fixture",
      "source": "term:mechanical-shock-test",
      "target": "term:battery-cell-fixture",
      "type": "usesTestEquipment",
      "properties": {
        "sourceFile": "wiki-editorial.json"
      }
    },
    {
      "id": "edge:cites/term:mechanical-shock-test/reference:un-tests",
      "source": "term:mechanical-shock-test",
      "target": "reference:un-tests",
      "type": "cites",
      "properties": {
        "sourceFile": "wiki-references.json",
        "scope": "direct technical reference"
      }
    },
    {
      "id": "edge:cites/term:mechanical-shock-test/reference:un-tests-amendment",
      "source": "term:mechanical-shock-test",
      "target": "reference:un-tests-amendment",
      "type": "cites",
      "properties": {
        "sourceFile": "wiki-references.json",
        "scope": "direct technical reference"
      }
    },
    {
      "id": "edge:cites/term:mechanical-shock-test/reference:sandia-abuse-manual",
      "source": "term:mechanical-shock-test",
      "target": "reference:sandia-abuse-manual",
      "type": "cites",
      "properties": {
        "sourceFile": "wiki-references.json",
        "scope": "direct technical reference"
      }
    }
  ],
  "neighbors": [
    {
      "id": "topic:topic-testing",
      "type": "Topic",
      "label": "Testing methods",
      "properties": {
        "id": "topic-testing",
        "name": "Testing methods",
        "lede": "The measurements and test procedures that characterise a cell or pack, from capacity and pulse tests to abuse and environmental tests.",
        "context": "Record specimen, state, instrument, temperature and timing.",
        "example": "Resistance immediately after a current step can differ from a ten-second value because slower polarization contributes.",
        "lesson_url": "https://lemonergy.com/learn/fundamentals/capacity-and-c-rate/",
        "lesson_label": "Open capacity measurements"
      }
    },
    {
      "id": "term:battery-shaker",
      "type": "Term",
      "label": "Vibration shaker and shock equipment",
      "properties": {
        "id": "battery-shaker",
        "name": "Vibration shaker and shock equipment",
        "section": "topic-testing-equipment",
        "definition": "A vibration shaker or shock system applies controlled mechanical motion to a mounted specimen. Accelerometers and suitable fixtures distinguish the applied input from the specimen response.",
        "related": [
          "vibration-test",
          "mechanical-shock-test",
          "power-spectral-density",
          "battery-test-equipment"
        ],
        "example": {
          "title": "Worked example",
          "text": "A shaker command and a fixture accelerometer may differ near a fixture resonance. Compare the measured input and specimen response before interpreting the battery's mechanical behavior."
        },
        "url": "https://lemonergy.com/learn/glossary/battery-shaker/",
        "mentions": []
      }
    },
    {
      "id": "term:battery-data-acquisition",
      "type": "Term",
      "label": "Battery data acquisition system",
      "properties": {
        "id": "battery-data-acquisition",
        "name": "Battery data acquisition system",
        "section": "topic-testing-equipment",
        "definition": "A data acquisition system records and synchronizes channels such as voltage, temperature, current, pressure and displacement. Isolation, bandwidth and time alignment matter when different instruments observe the same event.",
        "related": [
          "thermocouples-rtds",
          "voltage-sense",
          "kelvin-sensing",
          "pulse-test",
          "battery-test-equipment"
        ],
        "example": {
          "title": "Worked example",
          "text": "During a fictional pulse, the voltage jumps before a slow temperature sensor changes. Record trigger time and each channel's sample rate to distinguish timing offsets from real thermal delay."
        },
        "url": "https://lemonergy.com/learn/glossary/battery-data-acquisition/",
        "mentions": []
      }
    },
    {
      "id": "term:battery-cell-fixture",
      "type": "Term",
      "label": "Battery test fixture and Kelvin leads",
      "properties": {
        "id": "battery-cell-fixture",
        "name": "Battery test fixture and Kelvin leads",
        "section": "topic-testing-equipment",
        "definition": "A fixture holds the cell and provides suitable electrical and sensor contacts. A four-wire arrangement uses separate voltage-sense and current paths to reduce lead and contact error in terminal readings.",
        "related": [
          "kelvin-sensing",
          "cycler",
          "acir",
          "dcir",
          "battery-test-equipment"
        ],
        "example": {
          "title": "Worked example",
          "text": "Moving voltage-sense clips from the instrument leads to appropriate specimen terminals changes which voltage drop is included. Document the exact sense points when comparing milliohm readings."
        },
        "url": "https://lemonergy.com/learn/glossary/battery-cell-fixture/",
        "mentions": []
      }
    },
    {
      "id": "term:testing",
      "type": "Term",
      "label": "Battery testing procedures",
      "properties": {
        "id": "testing",
        "name": "Battery testing procedures",
        "section": "topic-testing",
        "definition": "Battery testing procedures describe how to characterize performance, durability, environmental behavior and safety at cell, module or pack level. A test plan defines the specimen, conditions, equipment, measurements and the applicable evaluation method.",
        "related": [
          "capacity-test",
          "cycler",
          "reference-performance-test",
          "abuse-testing",
          "datasheet",
          "charging-strategies"
        ],
        "aka": [
          "Cell testing"
        ],
        "testChooser": [
          {
            "goal": "Measure performance",
            "term": "capacity-test",
            "title": "Capacity test",
            "description": "Measure how much charge and energy the battery delivers under defined conditions.",
            "details": {
              "Equipment": "Cycler, temperature chamber, and cell fixture",
              "Procedure": "Condition the cell, then discharge at the specified current",
              "Record": "Ah, Wh, temperature, and cutoff voltage"
            },
            "action": "Open the capacity test"
          },
          {
            "goal": "Understand aging",
            "term": "cycle-life-test",
            "title": "Cycle-life test",
            "description": "Track how repeated cycling changes capacity and resistance.",
            "details": {
              "Equipment": "Cycler, temperature chamber, and data logger",
              "Procedure": "Cycle the battery and repeat reference performance tests",
              "Record": "Capacity, resistance, and charge throughput"
            },
            "action": "Open the cycle-life test"
          },
          {
            "goal": "Investigate a failure",
            "term": "post-mortem",
            "title": "Post-mortem analysis",
            "description": "Connect observations from a failed battery to the affected component and its test history.",
            "details": {
              "Equipment": "Specialist lab with appropriate containment",
              "Procedure": "Trace each sample to its location in the battery",
              "Record": "Test history, sample location, and preparation"
            },
            "action": "Open the post-mortem guide"
          },
          {
            "goal": "Plan qualification",
            "term": "transport-regulations",
            "title": "Start with the applicable standard",
            "description": "Match the test program to the product and its intended use. For transport, check which UN 38.3 tests apply.",
            "details": {
              "Define": "Specimen and intended use",
              "Confirm": "Applicable method and edition",
              "Record": "Test results and report reference"
            },
            "action": "Open the UN 38.3 guide"
          }
        ],
        "example": {
          "title": "Worked example",
          "text": "Choose an initial capacity test and pulse resistance baseline for the same specimen. Keep the state of charge, temperature and instrument channels comparable so later repeat measurements can reveal changes."
        },
        "guide": [
          {
            "title": "Performance and efficiency",
            "terms": [
              "capacity-test",
              "rate-test",
              "ocv-test",
              "pulse-test",
              "hppc",
              "dcir",
              "acir",
              "fast-charge-capability-test",
              "round-trip-efficiency-test",
              "drive-cycle-battery-test"
            ]
          },
          {
            "title": "Aging and thermal measurements",
            "terms": [
              "cycle-life-test",
              "calendar-life-test",
              "reference-performance-test",
              "self-discharge-test",
              "thermal-characterisation",
              "isothermal-calorimetry",
              "accelerating-rate-calorimetry"
            ]
          },
          {
            "title": "Electrochemical and material diagnostics",
            "terms": [
              "electrochemical-impedance-spectroscopy",
              "gitt",
              "pitt",
              "cyclic-voltammetry",
              "chronoamperometry",
              "chronopotentiometry",
              "ultra-high-precision-coulometry",
              "differential-voltage-analysis",
              "incremental-capacity-analysis",
              "laser-flash-analysis",
              "hot-disk-method",
              "ultrasonic-cell-testing",
              "x-ray-computed-tomography",
              "post-mortem"
            ]
          },
          {
            "title": "Manufacturing and battery management",
            "terms": [
              "end-of-line-testing",
              "electrode-peel-test",
              "tab-pull-test",
              "helium-leak-test",
              "swelling-test",
              "fault-injection-testing",
              "insulation-test",
              "dielectric-withstand-test"
            ]
          },
          {
            "title": "Environment and mechanics",
            "terms": [
              "altitude-simulation-test",
              "thermal-shock-test",
              "vibration-test",
              "mechanical-shock-test",
              "damp-heat-test",
              "salt-spray-test",
              "immersion-test",
              "halt-hass",
              "impact-test"
            ]
          },
          {
            "title": "Safety and abuse",
            "terms": [
              "abuse-testing",
              "oven-test",
              "crush-test",
              "nail-penetration",
              "overcharge-test",
              "short-circuit-test",
              "propagation-test",
              "vehicle-crash-test",
              "transport-impact-crush-test",
              "forced-discharge-test"
            ]
          },
          {
            "title": "Transport and qualification references",
            "terms": [
              "transport-regulations",
              "iec-62660",
              "iso-12405",
              "iec-62133",
              "iec-62619",
              "un-r100",
              "ul-9540a"
            ]
          }
        ],
        "url": "https://lemonergy.com/learn/glossary/testing/",
        "mentions": []
      }
    },
    {
      "id": "term:battery-shaker",
      "type": "Term",
      "label": "Vibration shaker and shock equipment",
      "properties": {
        "id": "battery-shaker",
        "name": "Vibration shaker and shock equipment",
        "section": "topic-testing-equipment",
        "definition": "A vibration shaker or shock system applies controlled mechanical motion to a mounted specimen. Accelerometers and suitable fixtures distinguish the applied input from the specimen response.",
        "related": [
          "vibration-test",
          "mechanical-shock-test",
          "power-spectral-density",
          "battery-test-equipment"
        ],
        "example": {
          "title": "Worked example",
          "text": "A shaker command and a fixture accelerometer may differ near a fixture resonance. Compare the measured input and specimen response before interpreting the battery's mechanical behavior."
        },
        "url": "https://lemonergy.com/learn/glossary/battery-shaker/",
        "mentions": []
      }
    },
    {
      "id": "term:battery-data-acquisition",
      "type": "Term",
      "label": "Battery data acquisition system",
      "properties": {
        "id": "battery-data-acquisition",
        "name": "Battery data acquisition system",
        "section": "topic-testing-equipment",
        "definition": "A data acquisition system records and synchronizes channels such as voltage, temperature, current, pressure and displacement. Isolation, bandwidth and time alignment matter when different instruments observe the same event.",
        "related": [
          "thermocouples-rtds",
          "voltage-sense",
          "kelvin-sensing",
          "pulse-test",
          "battery-test-equipment"
        ],
        "example": {
          "title": "Worked example",
          "text": "During a fictional pulse, the voltage jumps before a slow temperature sensor changes. Record trigger time and each channel's sample rate to distinguish timing offsets from real thermal delay."
        },
        "url": "https://lemonergy.com/learn/glossary/battery-data-acquisition/",
        "mentions": []
      }
    },
    {
      "id": "term:battery-cell-fixture",
      "type": "Term",
      "label": "Battery test fixture and Kelvin leads",
      "properties": {
        "id": "battery-cell-fixture",
        "name": "Battery test fixture and Kelvin leads",
        "section": "topic-testing-equipment",
        "definition": "A fixture holds the cell and provides suitable electrical and sensor contacts. A four-wire arrangement uses separate voltage-sense and current paths to reduce lead and contact error in terminal readings.",
        "related": [
          "kelvin-sensing",
          "cycler",
          "acir",
          "dcir",
          "battery-test-equipment"
        ],
        "example": {
          "title": "Worked example",
          "text": "Moving voltage-sense clips from the instrument leads to appropriate specimen terminals changes which voltage drop is included. Document the exact sense points when comparing milliohm readings."
        },
        "url": "https://lemonergy.com/learn/glossary/battery-cell-fixture/",
        "mentions": []
      }
    },
    {
      "id": "reference:un-tests",
      "type": "Reference",
      "label": "UN Manual of Tests and Criteria, Revision 8",
      "properties": {
        "title": "UN Manual of Tests and Criteria, Revision 8",
        "publisher": "United Nations Economic Commission for Europe",
        "url": "https://unece.org/info/publications/pub/387256",
        "type": "Regulatory reference",
        "scope": "Dangerous-goods classification tests; subsection 38.3 concerns battery transport testing.",
        "year": 2023,
        "accessed": "2026-10-27"
      }
    },
    {
      "id": "reference:un-tests-amendment",
      "type": "Reference",
      "label": "Manual of Tests and Criteria, Revision 8, Amendment 1",
      "properties": {
        "title": "Manual of Tests and Criteria, Revision 8, Amendment 1",
        "publisher": "United Nations Economic Commission for Europe",
        "url": "https://unece.org/sites/default/files/2025-07/ST-SG-AC10-11-Rev8-Amend1e.pdf",
        "type": "Regulatory reference",
        "scope": "Amendments to Revision 8, including changes to battery testing in subsection 38.3.",
        "year": 2025,
        "accessed": "2026-10-27"
      }
    },
    {
      "id": "reference:sandia-abuse-manual",
      "type": "Reference",
      "label": "USABC Battery Abuse Testing Manual for Electric and Hybrid Vehicle Applications",
      "properties": {
        "title": "USABC Battery Abuse Testing Manual for Electric and Hybrid Vehicle Applications",
        "publisher": "Sandia National Laboratories",
        "url": "https://doi.org/10.2172/1838583",
        "type": "Test manual",
        "scope": "Electrical, thermal and mechanical abuse-test categories and reported observations.",
        "accessed": "2026-11-18"
      }
    }
  ]
}