  "node": {
    "id": "term:laser-flash-analyzer",
    "type": "Term",
    "label": "Laser flash analyzer",
    "properties": {
      "id": "laser-flash-analyzer",
      "name": "Laser flash analyzer",
      "section": "topic-testing-equipment",
      "definition": "A laser or light flash analyzer briefly heats one face of a prepared specimen and observes the temperature transient at the rear face. The transient and specimen thickness inform thermal diffusivity estimates.",
      "related": [
        "laser-flash-analysis",
        "battery-test-equipment",
        "thermal-characterisation"
      ],
      "example": {
        "title": "Worked example",
        "text": "A thin layered sample and a thick homogeneous sample need different fit assumptions. Retain the thermogram and sample orientation when discussing the measured diffusivity."
      },
      "url": "https://lemonergy.com/learn/glossary/laser-flash-analyzer/",
      "mentions": [
        "diffusion-coefficient",
        "thermal-diffusivity"
      ]
    }
  },
  "edges": [
    {
      "id": "edge:belongsTo/term:laser-flash-analyzer/topic:topic-testing-equipment",
      "source": "term:laser-flash-analyzer",
      "target": "topic:topic-testing-equipment",
      "type": "belongsTo",
      "properties": {
        "sourceFile": "terms.json"
      }
    },
    {
      "id": "edge:relatedTo/term:laser-flash-analyzer/term:laser-flash-analysis",
      "source": "term:laser-flash-analyzer",
      "target": "term:laser-flash-analysis",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:laser-flash-analyzer/term:battery-test-equipment",
      "source": "term:laser-flash-analyzer",
      "target": "term:battery-test-equipment",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:laser-flash-analyzer/term:thermal-characterisation",
      "source": "term:laser-flash-analyzer",
      "target": "term:thermal-characterisation",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:mentions/laser-flash-analyzer/diffusion-coefficient",
      "source": "term:laser-flash-analyzer",
      "target": "term:diffusion-coefficient",
      "type": "mentions",
      "properties": {
        "sourceFile": "terms.json",
        "method": "build_glossary.mention_index + mentions",
        "field": "definition",
        "meaning": "Text mention; not a causal claim"
      }
    },
    {
      "id": "edge:mentions/laser-flash-analyzer/thermal-diffusivity",
      "source": "term:laser-flash-analyzer",
      "target": "term:thermal-diffusivity",
      "type": "mentions",
      "properties": {
        "sourceFile": "terms.json",
        "method": "build_glossary.mention_index + mentions",
        "field": "definition",
        "meaning": "Text mention; not a causal claim"
      }
    },
    {
      "id": "edge:cites/term:laser-flash-analyzer/reference:netzsch-flash",
      "source": "term:laser-flash-analyzer",
      "target": "reference:netzsch-flash",
      "type": "cites",
      "properties": {
        "sourceFile": "wiki-references.json",
        "scope": "direct technical reference"
      }
    }
  ],
  "neighbors": [
    {
      "id": "topic:topic-testing-equipment",
      "type": "Topic",
      "label": "Testing equipment and instrumentation",
      "properties": {
        "id": "topic-testing-equipment",
        "name": "Testing equipment and instrumentation",
        "lede": "Sources, loads, fixtures and instruments for electrical, thermal, environmental and mechanical measurements.",
        "context": "Lemonergy models selected electrical and thermal measurements with simulated sensors and protocol steps. Test instrument selection, calibration and safety qualification belong to the laboratory.",
        "example": "On a pulse bench, compare commanded current with measured current and the voltage at the specimen sense points. Report the timing, ranges and calibration before deriving resistance.",
        "lesson_url": "https://lemonergy.com/learn/fundamentals/capacity-and-c-rate/#real-cells",
        "lesson_label": "Open the cell measurement examples"
      }
    },
    {
      "id": "term:laser-flash-analysis",
      "type": "Term",
      "label": "Laser flash analysis",
      "properties": {
        "id": "laser-flash-analysis",
        "name": "Laser flash analysis",
        "abbr": "LFA",
        "aka": [
          "laser flash method",
          "flash method"
        ],
        "section": "topic-testing",
        "definition": "Firing a brief laser pulse at one face of a thin disc and timing the temperature rise on the far face with an infrared detector, which gives thermal diffusivity. Multiplying by density and specific heat yields thermal conductivity — the through-plane value for electrodes, separators and layered cell samples.",
        "formula": "α = 0.1388·L² / t½; k = α·ρ·c_p",
        "related": [
          "thermal-characterisation",
          "hot-disk-method",
          "thermal-model",
          "heat-generation",
          "testing"
        ],
        "example": {
          "title": "Convert a half-rise time into diffusivity",
          "text": "For an ideal 1 mm slab with a rear-surface half-rise time of 0.10 s, α = 0.1388L²/t½ gives 1.388×10⁻⁶ m²/s. Heat loss, finite pulse duration and material anisotropy can require corrections."
        },
        "procedure": {
          "equipment": [
            "laser-flash-analyzer"
          ],
          "steps": [
            "Identify the specimen thickness, material direction and approved measurement geometry.",
            "Record the rear-face temperature transient following the instrument's light pulse.",
            "Fit an appropriate model and retain the correction assumptions."
          ],
          "record": "Report diffusivity, thickness, orientation, test temperature and the thermogram. State any assumptions used to estimate conductivity."
        },
        "url": "https://lemonergy.com/learn/glossary/laser-flash-analysis/",
        "mentions": [
          "diffusion-coefficient",
          "thermal-conductivity",
          "specific-heat-capacity",
          "thermal-diffusivity"
        ]
      }
    },
    {
      "id": "term:battery-test-equipment",
      "type": "Term",
      "label": "Battery testing equipment",
      "properties": {
        "id": "battery-test-equipment",
        "name": "Battery testing equipment",
        "section": "topic-testing-equipment",
        "definition": "Battery testing equipment controls the electrical and environmental conditions applied to a cell, module or pack and records its response. The test objective determines the instrument, fixture, sensing range and safety provisions.",
        "related": [
          "testing",
          "cycler",
          "potentiostat",
          "charging-strategies"
        ],
        "example": {
          "title": "Worked example",
          "text": "A capacity bench and an environmental screening station may both record voltage and temperature. Only the capacity bench needs a calibrated source and load that can integrate current over the full cycle."
        },
        "guide": [
          {
            "title": "Source, sink and electrical measurement",
            "terms": [
              "cycler",
              "bidirectional-dc-supply",
              "electronic-load",
              "battery-current-transducer",
              "battery-cell-fixture",
              "kelvin-sensing",
              "voltage-sense"
            ]
          },
          {
            "title": "Electrochemical instrumentation",
            "terms": [
              "potentiostat",
              "battery-impedance-analyzer",
              "working-and-counter-electrode",
              "reference-electrode"
            ]
          },
          {
            "title": "Environment, thermal and mechanical equipment",
            "terms": [
              "battery-test-chamber",
              "thermocouples-rtds",
              "battery-coolant-conditioner",
              "battery-altitude-chamber",
              "battery-calorimeter",
              "battery-shaker",
              "battery-material-test-frame",
              "battery-thickness-gauge",
              "laser-flash-analyzer",
              "transient-plane-source-analyzer"
            ]
          },
          {
            "title": "Safety, controls and inspection",
            "terms": [
              "battery-data-acquisition",
              "insulation-resistance-tester",
              "dielectric-withstand-tester",
              "battery-abuse-enclosure",
              "battery-gas-analysis",
              "battery-pack-hil-bench",
              "x-ray-computed-tomography",
              "scanning-electron-microscopy",
              "gas-chromatography-mass-spectrometry",
              "helium-leak-detector",
              "battery-ultrasound-instrument"
            ]
          }
        ],
        "url": "https://lemonergy.com/learn/glossary/battery-test-equipment/",
        "mentions": []
      }
    },
    {
      "id": "term:thermal-characterisation",
      "type": "Term",
      "label": "Thermal characterisation",
      "properties": {
        "id": "thermal-characterisation",
        "name": "Thermal characterisation",
        "aka": [
          "heat capacity test",
          "entropy test"
        ],
        "section": "topic-testing",
        "definition": "Measuring the thermal properties a model needs: specific heat capacity in a calorimeter, thermal conductivity through and along the layers, the entropy coefficient from OCV against temperature, and heat generation under load. Without them a thermal model is a guess.",
        "related": [
          "heat-generation",
          "entropy-coefficient",
          "thermal-model",
          "accelerating-rate-calorimetry",
          "battery-calorimeter",
          "battery-coolant-conditioner"
        ],
        "example": {
          "title": "What the report shows",
          "text": "The test record connects the specimen and conditions to the observation. Record electrical input, temperature locations, ambient or coolant conditions, and which heat quantity was measured or inferred."
        },
        "procedure": {
          "equipment": [
            "battery-calorimeter",
            "battery-coolant-conditioner",
            "battery-test-chamber",
            "thermocouples-rtds"
          ],
          "steps": [
            "Define the thermal boundary, electrical operating point and sensor placement.",
            "Record temperature and heat or coolant response under the approved excitation.",
            "Compare heat flow and temperature rise with the stated boundary and measurement uncertainty."
          ],
          "record": "Record electrical input, temperature locations, ambient or coolant conditions, and which heat quantity was measured or inferred."
        },
        "url": "https://lemonergy.com/learn/glossary/thermal-characterisation/",
        "mentions": [
          "open-circuit-voltage",
          "thermal-conductivity",
          "specific-heat-capacity"
        ]
      }
    },
    {
      "id": "term:diffusion-coefficient",
      "type": "Term",
      "label": "Diffusion coefficient",
      "properties": {
        "id": "diffusion-coefficient",
        "name": "Diffusion coefficient",
        "abbr": "D",
        "aka": [
          "diffusivity"
        ],
        "section": "topic-transport",
        "definition": "The proportionality constant D in Fick’s first law, in m²/s. It sets how fast a species spreads for a given concentration gradient.",
        "unit": "m²/s",
        "related": [
          "ficks-first-law",
          "solid-state-diffusion",
          "gitt",
          "diffusion"
        ],
        "lesson": "transport/ficks-first-law/#law",
        "url": "https://lemonergy.com/learn/glossary/diffusion-coefficient/",
        "mentions": [
          "concentration-gradient"
        ]
      }
    },
    {
      "id": "term:thermal-diffusivity",
      "type": "Term",
      "label": "Thermal diffusivity",
      "properties": {
        "id": "thermal-diffusivity",
        "name": "Thermal diffusivity",
        "abbr": "α",
        "section": "topic-thermal",
        "definition": "How quickly temperature evens out inside a material: thermal conductivity divided by density times specific heat. Heat spreads a distance L in roughly L²/α, so crossing a 10 mm cell at about 0.2 mm²/s through-plane takes several minutes, while aluminium, near 100 mm²/s, equalises almost at once.",
        "formula": "α = k / (ρ·cₚ)",
        "unit": "m²/s",
        "related": [
          "thermal-conductivity",
          "specific-heat-capacity",
          "thermal-gradient",
          "biot-number",
          "thermal-model"
        ],
        "example": {
          "title": "Compare heat-spreading rates",
          "text": "For an illustrative material with k = 1 W/(m·K), density 2000 kg/m³ and cₚ = 1000 J/(kg·K), α = 5×10⁻⁷ m²/s. A higher α means a temperature disturbance spreads faster for the same geometry."
        },
        "url": "https://lemonergy.com/learn/glossary/thermal-diffusivity/",
        "mentions": []
      }
    },
    {
      "id": "reference:netzsch-flash",
      "type": "Reference",
      "label": "Laser flash analyzer measurement principle",
      "properties": {
        "title": "Laser flash analyzer measurement principle",
        "publisher": "NETZSCH",
        "url": "https://analyzing-testing.netzsch.com/en-AU/services/contract-testing/methods/laser-flash-technique-lfa-1/",
        "type": "Instrument technical documentation",
        "scope": "Instrument geometry, signal and measurement principle.",
        "accessed": "2026-11-18"
      }
    }
  ]
}